| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC10G |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Uniformity | ±0.5°C |
| Sample Capacity | 10 positions |
| Tube Diameter Compatibility | 16 mm (optional) |
| Gas Flow Control Range | 0–999 mL/min |
| Heating Power | Not specified |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC30G |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Uniformity | ±0.5°C |
| Sample Capacity | 30 positions |
| Tube Diameter Compatibility | 16 mm (optional) |
| Gas Flow Control Range | 0–999 mL/min |
| Programmable Stages | 50 segments |
| Display | 7-inch capacitive touchscreen |
| Heating Block Material | Aerospace-grade aluminum alloy |
| Gas Preheating Function | Yes (~45°C) |
| Sealing System | Dual-seal observation door with internal recirculating fan |
| Data Storage | Internal multi-session logging |
| Gas Distribution | Independent solenoid valve per channel |
| Lift Mechanism | Motorized dual-mode (fine-adjust + rapid) needle positioning |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | DC36S |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±1 °C |
| Sample Capacity | 36 positions |
| Tube Diameter Compatibility | 16 mm (optional) |
| Gas Flow Control | Independent electromagnetic valve per channel |
| Power Supply | See technical specifications |
| Auto-refill Function | Yes |
| Dual-sealed observation window system | Yes |
| Touchscreen Interface | 7-inch LCD with programmable logic |
| Program Storage | Multiple user-defined protocols (50 segments, 5 modes) |
| Safety Features | Dry-run protection, overflow outlet, lid-open alarm, auto-resume after interruption, acid-resistant surface treatment |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AYAN-AUTOM-12S |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±0.5 °C |
| Sample Vessel Capacity | 50 / 100 / 150 / 200 mL |
| Gas Flow Control | 0–999 mL/min (digital regulation) |
| Sample Positions | 12 |
| Heating Power | 1.2 kW (typical for dual-zone water bath) |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AYAN-DC20S |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Sample Tube Diameter Compatibility | 10–30 mm |
| Gas Flow Control Range | 0–999 mL/min (adjustable per channel) |
| Sample Capacity | 20 positions |
| Heating Power | 800 W (typical for 20-position water bath configuration) |
| Brand | ANYAN (Hangzhou Anyan Instrument Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | DC16G |
| Heating Method | Dry-block heating |
| Temperature Control Range | ±1 °C |
| Sample Capacity | 16 positions |
| Heating Power | 220 W |
| Heating Block Material | High-purity aluminum alloy |
| Display | 7-inch capacitive touch LCD |
| Temperature Range | Ambient to 100 °C |
| Timer Range | 0–999 min |
| Gas Pressure Regulation | 0–0.8 MPa |
| Independent Gas Flow Control | 4-channel electromagnetic valve array |
| Pre-heated N₂ Inlet | ~45 °C |
| Filtration | 0.01 µm nitrogen particulate filter |
| Safety Features | Over-temperature cutoff, real-time pressure monitoring, automatic fault detection and alarm |
| Viewing System | Four-sided transparent chamber with dual observation windows and drawer-type sample tray |
| Gas Delivery | Integrated pre-heating module + sealed gas distribution manifold |
| Data Logging | Onboard storage for runtime parameters (temperature, pressure, time) |
| Compliance Support | Designed for GLP-compliant workflows |
| Brand | ANYAN (Hangzhou Anyan Instrument Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC16G |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Sample Capacity | 16 positions |
| Heating Power | 220 W |
| Display | 7-inch capacitive touch LCD |
| Programmable Stages | 50 segments |
| Control Modes | 5 preset operational modes |
| Gas Pressure Range | 0–0.8 MPa |
| Independent Gas Flow Control | 16 channels |
| Sample Tube Diameter | 16 mm (interchangeable modules) |
| Timer Range | 0–999 min |
| Vertical Needle Adjustment | Dual-mode (fine-tuning + rapid lift) |
| Integrated Preheated N₂ Supply | ~45 °C |
| Sealing System | Dual-layer door gasket with recirculating fan |
| Housing Design | Front & side observation windows |
| Sample Tray | Drawer-type sliding rack |
| Data Logging | Built-in storage for runtime parameters |
| Safety Features | Over-temperature alarm, automatic gas shutoff logic, sealed chamber architecture |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-AUTOM-12S |
| Heating Method | Water Bath |
| Temperature Range | 0–100 °C |
| Temperature Uniformity | ±1 °C |
| Sample Capacity | 12 positions |
| Vial Size Compatibility | 50–200 mL |
| Gas Flow Control Range | 0–999 mL/min (adjustable per channel) |
| Precise Endpoint Detection | Optical sensor-based volumetric termination (0.5 / 1 / 2 mL or near-dry) |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC36S |
| Heating Method | Water-bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±1 °C |
| Sample Capacity | 36 positions |
| Tube Diameter | 16 mm (customizable) |
| Gas Flow Control | 0–999 mL/min (digital mass flow regulation) |
| Display | 7-inch capacitive touchscreen |
| Programmable Temperature Profiles | 50 segments across 5 operating modes |
| Timer Range | 0–999 min |
| Pressure Regulation | 0–0.8 MPa with independent solenoid valve per channel |
| Preheated Nitrogen Delivery | ~45 °C |
| Power Supply | 220 V, 50 Hz |
| Net Weight | 25 kg |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AYAN-DC25G |
| Price Range | USD 5,600 – 8,400 (FOB) |
| Heating Method | Dry-block (aluminum alloy heating module) |
| Temperature Range | Ambient to 150 °C |
| Temperature Stability | ±0.5 °C |
| Sample Capacity | 25 positions |
| Tube Diameter Compatibility | Up to 16 mm (interchangeable modules available) |
| Gas Flow Control Range | 0–999 mL/min (digital mass flow regulation per channel) |
| Control Interface | 7-inch capacitive touchscreen |
| Programmability | 50-step temperature ramping profiles across 5 operating modes |
| Gas Preheating | Yes (to ~45 °C) |
| Sealing System | Dual-glass door with silicone gasket and internal recirculating blower |
| Data Logging | Internal storage for ≥100 run logs with timestamped temperature/flow/position data |
| Power Rating | 1.2 kW |
| Brand | ANYAN (Hangzhou Anyan Instrument Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC16G |
| Sample Capacity | 16 positions |
| Heating Method | Dry block heating |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Display | 7-inch LCD touch screen |
| Control Modes | 5 preset modes |
| Programmable Temperature Segments | 50 |
| Timer Range | 0–999 min |
| Visual Design | 4-sided transparent viewing windows |
| Sample Access | Drawer-style sliding tray |
| Needle Adjustment | Dual-mode (fine-tuning + rapid lift) |
| Gas Pressure Regulation | 0–0.8 MPa |
| Independent Gas Flow Control | 16-channel electromagnetic valve array |
| Preheated Nitrogen Inlet | ~45 °C |
| Integrated Circulating Fan System | Yes |
| Dual-seal Door Protection | Yes |
| Built-in Data Logging | Yes |
| Heating Power | 220 W |
| Heating Block Material | Aerospace-grade aluminum alloy |
| Module Diameter Compatibility | 16 mm (interchangeable) |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC12G |
| Heating Method | Dry-Block Heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Uniformity | ±1°C |
| Sample Capacity | 12 positions |
| Tube Diameter Compatibility | Up to 16 mm (interchangeable modules) |
| Gas Flow Control Range | 0–999 mL/min (digital mass flow control) |
| Programmable Stages | 50-step temperature ramping |
| Display | 7-inch capacitive touchscreen interface |
| Gas Preheating | Yes (≈45°C) |
| Sealing System | Dual-gasket sealed door with internal recirculating fan |
| Data Logging | Built-in multi-session storage with timestamped operational records |
| Power Supply | Standard 220 VAC, 50 Hz |
| Safety Features | Overtemperature protection, gas leak detection alarm, automatic shutdown on door opening |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AYAN-AUTOM-12G |
| Heating Method | Dry-Block Heating |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±1 °C |
| Sample Capacity | 12 positions |
| Gas Flow Control Range | 0–999 mL/min |
| Heating Power | 300 W (typical for dry-block configuration) |
| Tube Compatibility | Accepts 10–29 mm OD round-bottom tubes (standard 12 × 16 mm or 12 × 18 mm formats) |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | AYAN-AUTOM-12S |
| Price | USD 3,950 (FOB) |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Sample Capacity | 12 positions |
| Vial Compatibility | 50–200 mL (adjustable), standard 16–20 mm OD |
| Gas Flow Control | 0–0.8 MPa, 12-channel independent electromagnetic valve regulation |
| Optical Endpoint Detection | Adjustable setpoints at near-dry, 0.5 mL, 1 mL, or 2 mL |
| Timing Range | 0–999 min |
| Auto-refill Function | Yes |
| Dual-seal Hydraulic Door System | Yes |
| Integrated Exhaust Fan with Activated Carbon Filter | Yes |
| Pre-heated Nitrogen Delivery (≈45 °C) | Yes |
| Power Supply | 220 V, 50 Hz |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC30S |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Sample Capacity | 30 positions |
| Gas Flow Control | 0–999 mL/min (adjustable per channel) |
| Display | 7-inch capacitive touchscreen |
| Program Storage | Multi-set user-defined protocols (50 segments, 5 control modes) |
| Safety Features | Auto-refill water tank, dry-run protection, overflow outlet, lid-open alarm, resume-on-interruption logic |
| Construction | 304 stainless steel frame, silicone-free silicone gaskets, double-sealed observation windows with built-in LED illumination and internal recirculating fan |
| Compliance | Designed for GLP-compliant laboratories |