BrandLANTIAN
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelAOX-WK-S
Detection PrincipleMicrocoulometric Titration after High-Temperature Combustion
ComplianceHJ 1214–2021 (China National Standard)
Maximum Generator Current±2 mA
Amplifier Output Voltage±30 V
Bias Voltage Range0–500 mV (continuously adjustable)
Detection Limit0.007 µg/L (at 100 mL sample volume)
Optimal Measurement Range (as Cl)0.02–2 mg/kg
Precision≤10% RSD (for samples ≤2 mg/L)
Activated Carbon Loading50 mg ±5 mg
Combustion Temperature Range500–1100 °C (±1 °C accuracy)
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Rated Power3000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLANTIAN
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelAOX-WK-S
Compliance StandardHJ 1214–2021 (PRC National Ecological and Environmental Standard)
Generator Current Range±2 mA
Amplifier Output Voltage±30 V
Bias Voltage Adjustment Range0–500 mV (continuously adjustable)
Detection Limit0.007 µg/L (at 100 mL sample volume)
Measurement Range (as Cl)0.02–2 mg/kg
Accuracy±1 µg Cl
Repeatability≤10% RSD (for samples ≤2 mg/L)
Activated Carbon Dosage50 mg ±5 mg
Combustion Temperature Control Range500–1100 °C
Stability±1 °C
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Rated Power3000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLANTIAN
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelAOX-WK-S
Compliance StandardHJ 1214–2021
Detection PrincipleMicrocoulometric Titration
Max Generator Current±2 mA
Amplifier Output Voltage±30 V
Bias Voltage Range0–500 mV (continuously adjustable)
Detection Limit0.007 mg/L (at 100 mL sample volume)
Optimal Measurement Range (as Cl)0.02–2 mg/kg
Accuracy≤10% relative deviation (at 1 µg Cl)
Repeatability≤10% RSD (for samples ≤2 mg/L)
Activated Carbon Dosage50 mg ±5 mg
Combustion Temperature Range500–1100 °C (±1 °C control accuracy)
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Rated Power3000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLANTIAN
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelAOX-WK-3 Microcoulometric Halogen Analyzer
Detection PrincipleMicrocoulometric Titration after High-Temperature Combustion (900–1100 °C)
Applicable StandardsGB/T 34845–2017, GB/T 22904–2008, GB/T 35613–2017, GB/T 39084–2020, GB/T 35611–2017, GB/T 41533–2022
Detection TargetAdsorbable Organic Halogens (AOX), expressed as Cl⁻
Detection Limit2 mg/kg
Quantification Range0.5–5 mg/kg (Cl)
Precision±1 µg Cl
Repeatability≤10% RSD at ≤2 mg/L sample concentration
Combustion Temperature Control500–1100 °C, ±1 °C accuracy
Generator Current Range±2 mA
Amplifier Output Voltage±30 V
Bias Voltage Adjustment0–500 mV, continuously adjustable
Sample Introduction50 mg ±5 mg activated carbon cartridge
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Rated Power3000 W
InterfaceRS-232 (DB9)
Software PlatformWindows-based proprietary AOX analysis suite with real-time parameter monitoring, data logging, audit trail, and report generation (PDF/CSV export)