| Brand | Bacharach |
|---|---|
| Origin | USA |
| Model | 7100P |
| Measurement Range | 0–100 ppm / 0–1000 ppm (auto-ranging) |
| Sensor Type | Miniature Zirconia (ZR-400) |
| Accuracy | ±3 ppm or ±2.0% of reading (whichever is greater) |
| Response Time | <15 s T90 at 500 mL/min |
| Sample Interface | 1/8" NPT female |
| Enclosure Rating | Front Panel — NEMA 4 (IP66), Electronics Chassis — NEMA 1 (IP20) |
| Display | 0.75" LED, dual-color (green = normal/online, yellow = fault) |
| Alarms | Two user-configurable relay alarms + one fixed system-fault relay |
| Analog Outputs | 0–1 VDC, 0–5 VDC, 0–10 VDC, and 4–20 mA |
| Digital Interface | RS-232 service port |
| Power Supply | 90–264 VAC or 24 VDC |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Relative Humidity | 0–95% RH (non-condensing) |
| Weight | <2.2 kg |
| Brand | Bacharach |
|---|---|
| Origin | USA |
| Model | 7100 |
| Measurement Range | 0–100 ppm / 0–1000 ppm |
| Sensor Type | Miniature Zirconia (ZR-400) |
| Accuracy | ±2.0% of reading or ±3 ppm (whichever is greater) |
| Response Time (T90) | <10 s at 500 mL/min |
| Display | 0.75" LED numeric |
| Enclosure Rating | Front panel NEMA 4 (IP66), Electronics chassis NEMA 1 (IP20) |
| Operating Temperature | 5–40°C |
| Humidity | 0–95% RH non-condensing |
| Power Input | 90–264 VAC or 24 VDC |
| Analog Outputs | 0–1 VDC, 0–5 VDC, 0–10 VDC, 4–20 mA |
| Digital Interface | RS-232 service port |
| Relay Outputs | 2 field-adjustable alarm relays + 1 fixed system fault relay |
| Sample Connection | 1/8" NPT female |
| Weight | <2.2 kg |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0100 |
| Instrument Type | Cone-Plate Rotational Viscometer |
| Temperature Range | 10 °C to 100 °C |
| Sample Volume | 0.2 mL |
| Compliance | BS EN ISO 2884-1:2006 |
| Full-Scale Accuracy | ±2% (calibrated with standard oils) |
| Speed Range | 5–900 rpm (integer steps) |
| Low-Speed Mode | 5–90 rpm (0.1 rpm increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Display | 4.3-inch color LCD |
| Data Interface | USB |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.5 kg |
| Brand | ATLANTEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 400 |
| Pricing | Available Upon Request |
| Printing Method | Direct Thermal |
| Print Resolution | 300 dpi |
| Print Width | 53 mm |
| Sample Width | 100 mm |
| Printhead Architecture | Thin-Film, Corner-Type |
| Print Speed | Programmable at 10 in/s (254 mm/s) |
| Adjustable Parameters | Printhead Pressure, Printhead Position |
| Interface | RS-232 Serial |
| Power Supply | 115 V / 60 Hz or 220 V / 50 Hz |
| Test Patterns | Checkerboard, Solid Fill, UPC-A Barcode, User-Defined Patterns |
| Test Modes | Dynamic Reaction Sequence (10 programmable energy steps), Single-Step Execution, Repetition Options (1×, 5×, 10× per step) |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0230 |
| Temperature Range | Ambient to 230 °C (no cooling) |
| Sample Volume | 0.2 mL |
| Compliance | BS EN ISO 2884-1:2006 |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 5–900 rpm (integer steps) |
| Viscosity Accuracy | ±2% of full scale (calibrated with standard oils) |
| Display | 4.3″ color LCD |
| Data Interface | USB |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.0 kg |
| Brand | AlphaOmega |
|---|---|
| Origin | USA |
| Model | 2520 |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–50%, 0–100% O₂ |
| Accuracy | ±0.1% FS |
| Linearity | ±0.1% FS |
| Response Time (t₉₀) | <10 s |
| Sensor Type | Electrochemical (O₂-specific) |
| Sample Temperature | 0–50 °C |
| Sample Pressure | 0.1–1 kg/cm² |
| Sample Flow Rate | 0.5–1.0 L/min |
| Temperature Compensation | Built-in |
| Display | 3½-digit LCD |
| Power | Rechargeable NiCd battery + universal AC adapter (battery charges during AC operation) |
| Enclosure | NEMA 1-rated polycarbonate |
| Dimensions | 5.8" H × 6.7" W × 3.4" D |
| Weight | <1 kg |
| Inlet/Outlet | Quick-connect fittings |
| Integrated Components | 12 VDC sampling pump, flowmeter with control valve at outlet |
| Analog Output | None |
| Brand | AlphaOmega |
|---|---|
| Origin | USA |
| Model | ZRO 2000 |
| Measurement Range | 0–100% O₂ (ppb–100% trace-to-full scale) |
| Accuracy | ±2% of reading (subject to clean, non-reducing sample gas) |
| Operating Temperature | 10–40 °C |
| Sample Gas Temperature Limit | ≤50 °C |
| Sample Pressure Range | 0.007–0.035 kg/cm² (≈1–5 psig) |
| Relative Humidity Limit | ≤85% RH |
| Power Input | 90–264 VAC, 50/60 Hz |
| Analog Output | Selectable 0–20 mA or 4–20 mA DC |
| Alarm Outputs | Two SPDT relays (10 A @ 30 VDC / 115–230 VAC) |
| Display | 6-digit LCD, 0.7" character height (17.8 mm) |
| Enclosure | Aluminum, NEMA 1-rated |
| Dimensions | 13" H × 10.71" W × 6.3" D |
| Sample Connection | 1/4" stainless steel compression fittings |
| Sensor Type | Heated zirconia electrochemical cell |
| Internal Audible Alarm | Yes, with front-panel mute switch |
| Brand | Dukin |
|---|---|
| Origin | South Korea |
| Model | GIANT |
| Structure | Cantilever (Horizontal Arm) |
| Base Material | Granite |
| Bearing Type | Air-bearing (High-Rigidity) |
| Thermal Compensation | Integrated Real-Time Temperature Compensation System |
| Compliance | Designed for ISO 10360-2 & ASME B89.4.1-2019 geometric accuracy verification |
| Brand | QINGTAO |
|---|---|
| Model | QT-N1 |
| Measurement Principle | Dual-mode (Eddy Current for Non-Magnetic Substrates, Magnetic Induction for Ferrous Substrates) |
| Measurement Range | 0–1250 µm |
| Resolution | 0.1 µm |
| Accuracy | ±(3% H + 1.5 µm) with Single-Point Calibration |
| Substrate Compatibility | Ferrous metals (Fe, steel) and non-ferrous non-magnetic metals (Al, Cu, Zn, Sn) |
| Coating Types | Non-conductive (paint, enamel, plastic, rubber) and non-magnetic metallic (e.g., Cr, Zn on steel) |
| Probe Options | F1, F1/90°, F10, N1, N1/90°, N10 |
| Data Storage | 500 readings |
| Statistical Functions | MEAN, MAX, MIN, NO, S.DEV |
| Calibration Modes | Single-point & two-point |
| Operating Temperature | −10 °C to 50 °C |
| Power | 2 × AA (1.5 V) |
| Dimensions | 125 × 67 × 31 mm |
| Weight | ~340 g |
| Compliance | GB/T 4956–1985, GB/T 4957–1985 & –2003, JB/T 8393–1996, JJG 889–1995, JJG 818–1993 |
| Brand | RJS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D4000 |
| Pricing | Available Upon Request |
| Brand | QINGTAO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | QT-KY01 |
| Max Test Load | 2000 kgf |
| Accuracy Class | Class 1 (per GB/T 16491 / ISO 7500-1) |
| Force Measurement Range | 0.4–100% FS |
| Force Accuracy | ±1% of reading |
| Force Resolution | 1/200,000 |
| Displacement Accuracy | ±1% of reading |
| Displacement Resolution | 0.05 mm |
| Test Speed Range | 10–300 mm/min |
| Speed Accuracy | ±1% of set value |
| Test Chamber Dimensions (optional) | 600×600×600 mm, 800×800×800 mm, 1000×1000×1000 mm, 1200×1200×1200 mm, or 1500×1500×1500 mm |
| Control System | Embedded microcomputer with optional industrial touchscreen interface |
| Drive System | Gearmotor + frequency inverter |
| Motor Power | 0.75 kW |
| Compliance Standards | ISO 2872, ISO 2874, TAPPI T 804, JIS Z 0212, NF H3 001, CNS 2236 / 3511, QB/T 1048 |
| Brand | Dukin |
|---|---|
| Origin | South Korea |
| Model | SIGMA 564 |
| Structure | Dual-Column Bridge |
| Base Material | Granite |
| Bearing Type | Air-bearing |
| Application Scope | Small-to-Medium-Sized Precision Components |
| Compliance Context | ISO 10360, VDI/VDE 2617, ASME B89.4.10 |
| Brand | Dillon |
|---|---|
| Origin | United Kingdom |
| Model | AWT05-506447 |
| Construction | Industrial-grade RF module with IP65-rated housing |
| Operating Range | Up to 300 ft (91 m) line-of-sight |
| Battery Life | ≥12 months (CR2032 lithium coin cell) |
| Compatibility | All Dillon EDXTREME series digital force gauges (EDx–1T through EDx–250T) |
| Protocol | Proprietary 2.4 GHz FHSS (Frequency-Hopping Spread Spectrum) |
| Certifications | CE, UKCA, FCC Part 15 Subpart C |
| Brand | Regula |
|---|---|
| Origin | Belarus |
| Model | 1019 |
| Dimensions (L×W×H) | 96 × 45 × 58 mm |
| Weight (without batteries) | 0.15 kg |
| Power Supply | 2 × AAA batteries |
| Magnification | 10× or 15× (switchable) |
| Focusing | Manual, continuous variable focus |
| Illumination Modes | White light, dual-side lighting, ring light (for OVD/hologram inspection), white/UV flash combination, four UV bands (254 nm, 313 nm, 365 nm, 400 nm), coaxial illumination, wide-field anti-Stokes illumination, narrow-field anti-Stokes illumination |
| Reticle | Integrated calibrated scale graticule for dimensional measurement |
| Compliance | Designed for forensic document examination workflows in accordance with ISO/IEC 17025–aligned laboratory practices |
Show next