Empowering Scientific Discovery

Hangzhou Qingtao Industrial Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBacharach
OriginUSA
Model7100P
Measurement Range0–100 ppm / 0–1000 ppm (auto-ranging)
Sensor TypeMiniature Zirconia (ZR-400)
Accuracy±3 ppm or ±2.0% of reading (whichever is greater)
Response Time<15 s T90 at 500 mL/min
Sample Interface1/8" NPT female
Enclosure RatingFront Panel — NEMA 4 (IP66), Electronics Chassis — NEMA 1 (IP20)
Display0.75" LED, dual-color (green = normal/online, yellow = fault)
AlarmsTwo user-configurable relay alarms + one fixed system-fault relay
Analog Outputs0–1 VDC, 0–5 VDC, 0–10 VDC, and 4–20 mA
Digital InterfaceRS-232 service port
Power Supply90–264 VAC or 24 VDC
Operating Temperature5–40 °C (41–104 °F)
Relative Humidity0–95% RH (non-condensing)
Weight<2.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBacharach
OriginUSA
Model7100
Measurement Range0–100 ppm / 0–1000 ppm
Sensor TypeMiniature Zirconia (ZR-400)
Accuracy±2.0% of reading or ±3 ppm (whichever is greater)
Response Time (T90)<10 s at 500 mL/min
Display0.75" LED numeric
Enclosure RatingFront panel NEMA 4 (IP66), Electronics chassis NEMA 1 (IP20)
Operating Temperature5–40°C
Humidity0–95% RH non-condensing
Power Input90–264 VAC or 24 VDC
Analog Outputs0–1 VDC, 0–5 VDC, 0–10 VDC, 4–20 mA
Digital InterfaceRS-232 service port
Relay Outputs2 field-adjustable alarm relays + 1 fixed system fault relay
Sample Connection1/8" NPT female
Weight<2.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATAC
OriginUnited Kingdom
ModelREL0100
Instrument TypeCone-Plate Rotational Viscometer
Temperature Range10 °C to 100 °C
Sample Volume0.2 mL
ComplianceBS EN ISO 2884-1:2006
Full-Scale Accuracy±2% (calibrated with standard oils)
Speed Range5–900 rpm (integer steps)
Low-Speed Mode5–90 rpm (0.1 rpm increments)
Temperature Control Accuracy±0.1 °C
Display4.3-inch color LCD
Data InterfaceUSB
Power Supply100–240 V AC, 50/60 Hz, 150 W
Dimensions (H×W×D)510 × 302 × 302 mm
Weight13.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLANTEK
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelModel 400
PricingAvailable Upon Request
Printing MethodDirect Thermal
Print Resolution300 dpi
Print Width53 mm
Sample Width100 mm
Printhead ArchitectureThin-Film, Corner-Type
Print SpeedProgrammable at 10 in/s (254 mm/s)
Adjustable ParametersPrinthead Pressure, Printhead Position
InterfaceRS-232 Serial
Power Supply115 V / 60 Hz or 220 V / 50 Hz
Test PatternsCheckerboard, Solid Fill, UPC-A Barcode, User-Defined Patterns
Test ModesDynamic Reaction Sequence (10 programmable energy steps), Single-Step Execution, Repetition Options (1×, 5×, 10× per step)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATAC
OriginUnited Kingdom
ModelREL0230
Temperature RangeAmbient to 230 °C (no cooling)
Sample Volume0.2 mL
ComplianceBS EN ISO 2884-1:2006
Temperature Accuracy±0.1 °C
Speed Range5–900 rpm (integer steps)
Viscosity Accuracy±2% of full scale (calibrated with standard oils)
Display4.3″ color LCD
Data InterfaceUSB
Power Supply100–240 V AC, 50/60 Hz, 150 W
Dimensions (H×W×D)510 × 302 × 302 mm
Weight13.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphaOmega
OriginUSA
Model2520
Measurement Ranges0–1%, 0–5%, 0–10%, 0–25%, 0–50%, 0–100% O₂
Accuracy±0.1% FS
Linearity±0.1% FS
Response Time (t₉₀)<10 s
Sensor TypeElectrochemical (O₂-specific)
Sample Temperature0–50 °C
Sample Pressure0.1–1 kg/cm²
Sample Flow Rate0.5–1.0 L/min
Temperature CompensationBuilt-in
Display3½-digit LCD
PowerRechargeable NiCd battery + universal AC adapter (battery charges during AC operation)
EnclosureNEMA 1-rated polycarbonate
Dimensions5.8" H × 6.7" W × 3.4" D
Weight<1 kg
Inlet/OutletQuick-connect fittings
Integrated Components12 VDC sampling pump, flowmeter with control valve at outlet
Analog OutputNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphaOmega
OriginUSA
ModelZRO 2000
Measurement Range0–100% O₂ (ppb–100% trace-to-full scale)
Accuracy±2% of reading (subject to clean, non-reducing sample gas)
Operating Temperature10–40 °C
Sample Gas Temperature Limit≤50 °C
Sample Pressure Range0.007–0.035 kg/cm² (≈1–5 psig)
Relative Humidity Limit≤85% RH
Power Input90–264 VAC, 50/60 Hz
Analog OutputSelectable 0–20 mA or 4–20 mA DC
Alarm OutputsTwo SPDT relays (10 A @ 30 VDC / 115–230 VAC)
Display6-digit LCD, 0.7" character height (17.8 mm)
EnclosureAluminum, NEMA 1-rated
Dimensions13" H × 10.71" W × 6.3" D
Sample Connection1/4" stainless steel compression fittings
Sensor TypeHeated zirconia electrochemical cell
Internal Audible AlarmYes, with front-panel mute switch
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDukin
OriginSouth Korea
ModelGIANT
StructureCantilever (Horizontal Arm)
Base MaterialGranite
Bearing TypeAir-bearing (High-Rigidity)
Thermal CompensationIntegrated Real-Time Temperature Compensation System
ComplianceDesigned for ISO 10360-2 & ASME B89.4.1-2019 geometric accuracy verification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQINGTAO
ModelQT-N1
Measurement PrincipleDual-mode (Eddy Current for Non-Magnetic Substrates, Magnetic Induction for Ferrous Substrates)
Measurement Range0–1250 µm
Resolution0.1 µm
Accuracy±(3% H + 1.5 µm) with Single-Point Calibration
Substrate CompatibilityFerrous metals (Fe, steel) and non-ferrous non-magnetic metals (Al, Cu, Zn, Sn)
Coating TypesNon-conductive (paint, enamel, plastic, rubber) and non-magnetic metallic (e.g., Cr, Zn on steel)
Probe OptionsF1, F1/90°, F10, N1, N1/90°, N10
Data Storage500 readings
Statistical FunctionsMEAN, MAX, MIN, NO, S.DEV
Calibration ModesSingle-point & two-point
Operating Temperature−10 °C to 50 °C
Power2 × AA (1.5 V)
Dimensions125 × 67 × 31 mm
Weight~340 g
ComplianceGB/T 4956–1985, GB/T 4957–1985 & –2003, JB/T 8393–1996, JJG 889–1995, JJG 818–1993
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRJS
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelD4000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQINGTAO
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelQT-KY01
Max Test Load2000 kgf
Accuracy ClassClass 1 (per GB/T 16491 / ISO 7500-1)
Force Measurement Range0.4–100% FS
Force Accuracy±1% of reading
Force Resolution1/200,000
Displacement Accuracy±1% of reading
Displacement Resolution0.05 mm
Test Speed Range10–300 mm/min
Speed Accuracy±1% of set value
Test Chamber Dimensions (optional)600×600×600 mm, 800×800×800 mm, 1000×1000×1000 mm, 1200×1200×1200 mm, or 1500×1500×1500 mm
Control SystemEmbedded microcomputer with optional industrial touchscreen interface
Drive SystemGearmotor + frequency inverter
Motor Power0.75 kW
Compliance StandardsISO 2872, ISO 2874, TAPPI T 804, JIS Z 0212, NF H3 001, CNS 2236 / 3511, QB/T 1048
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDukin
OriginSouth Korea
ModelSIGMA 564
StructureDual-Column Bridge
Base MaterialGranite
Bearing TypeAir-bearing
Application ScopeSmall-to-Medium-Sized Precision Components
Compliance ContextISO 10360, VDI/VDE 2617, ASME B89.4.10
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDillon
OriginUnited Kingdom
ModelAWT05-506447
ConstructionIndustrial-grade RF module with IP65-rated housing
Operating RangeUp to 300 ft (91 m) line-of-sight
Battery Life≥12 months (CR2032 lithium coin cell)
CompatibilityAll Dillon EDXTREME series digital force gauges (EDx–1T through EDx–250T)
ProtocolProprietary 2.4 GHz FHSS (Frequency-Hopping Spread Spectrum)
CertificationsCE, UKCA, FCC Part 15 Subpart C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRegula
OriginBelarus
Model1019
Dimensions (L×W×H)96 × 45 × 58 mm
Weight (without batteries)0.15 kg
Power Supply2 × AAA batteries
Magnification10× or 15× (switchable)
FocusingManual, continuous variable focus
Illumination ModesWhite light, dual-side lighting, ring light (for OVD/hologram inspection), white/UV flash combination, four UV bands (254 nm, 313 nm, 365 nm, 400 nm), coaxial illumination, wide-field anti-Stokes illumination, narrow-field anti-Stokes illumination
ReticleIntegrated calibrated scale graticule for dimensional measurement
ComplianceDesigned for forensic document examination workflows in accordance with ISO/IEC 17025–aligned laboratory practices
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0