Empowering Scientific Discovery

Hangzhou Qingtao Industrial Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBacharach
OriginUSA
Model7100P
Measurement Range0–100 ppm / 0–1000 ppm (auto-ranging)
Sensor TypeMiniature Zirconia (ZR-400)
Accuracy±3 ppm or ±2.0% of reading (whichever is greater)
Response Time<15 s T90 at 500 mL/min
Sample Interface1/8" NPT female
Enclosure RatingFront Panel — NEMA 4 (IP66), Electronics Chassis — NEMA 1 (IP20)
Display0.75" LED, dual-color (green = normal/online, yellow = fault)
AlarmsTwo user-configurable relay alarms + one fixed system-fault relay
Analog Outputs0–1 VDC, 0–5 VDC, 0–10 VDC, and 4–20 mA
Digital InterfaceRS-232 service port
Power Supply90–264 VAC or 24 VDC
Operating Temperature5–40 °C (41–104 °F)
Relative Humidity0–95% RH (non-condensing)
Weight<2.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBacharach
OriginUSA
Model7100
Measurement Range0–100 ppm / 0–1000 ppm
Sensor TypeMiniature Zirconia (ZR-400)
Accuracy±2.0% of reading or ±3 ppm (whichever is greater)
Response Time (T90)<10 s at 500 mL/min
Display0.75" LED numeric
Enclosure RatingFront panel NEMA 4 (IP66), Electronics chassis NEMA 1 (IP20)
Operating Temperature5–40°C
Humidity0–95% RH non-condensing
Power Input90–264 VAC or 24 VDC
Analog Outputs0–1 VDC, 0–5 VDC, 0–10 VDC, 4–20 mA
Digital InterfaceRS-232 service port
Relay Outputs2 field-adjustable alarm relays + 1 fixed system fault relay
Sample Connection1/8" NPT female
Weight<2.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphaOmega
OriginUSA
Model2520
Measurement Ranges0–1%, 0–5%, 0–10%, 0–25%, 0–50%, 0–100% O₂
Accuracy±0.1% FS
Linearity±0.1% FS
Response Time (t₉₀)<10 s
Sensor TypeElectrochemical (O₂-specific)
Sample Temperature0–50 °C
Sample Pressure0.1–1 kg/cm²
Sample Flow Rate0.5–1.0 L/min
Temperature CompensationBuilt-in
Display3½-digit LCD
PowerRechargeable NiCd battery + universal AC adapter (battery charges during AC operation)
EnclosureNEMA 1-rated polycarbonate
Dimensions5.8" H × 6.7" W × 3.4" D
Weight<1 kg
Inlet/OutletQuick-connect fittings
Integrated Components12 VDC sampling pump, flowmeter with control valve at outlet
Analog OutputNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlphaOmega
OriginUSA
ModelZRO 2000
Measurement Range0–100% O₂ (ppb–100% trace-to-full scale)
Accuracy±2% of reading (subject to clean, non-reducing sample gas)
Operating Temperature10–40 °C
Sample Gas Temperature Limit≤50 °C
Sample Pressure Range0.007–0.035 kg/cm² (≈1–5 psig)
Relative Humidity Limit≤85% RH
Power Input90–264 VAC, 50/60 Hz
Analog OutputSelectable 0–20 mA or 4–20 mA DC
Alarm OutputsTwo SPDT relays (10 A @ 30 VDC / 115–230 VAC)
Display6-digit LCD, 0.7" character height (17.8 mm)
EnclosureAluminum, NEMA 1-rated
Dimensions13" H × 10.71" W × 6.3" D
Sample Connection1/4" stainless steel compression fittings
Sensor TypeHeated zirconia electrochemical cell
Internal Audible AlarmYes, with front-panel mute switch
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare