Image Based Particle Size and Shape Analyzer
Filter
Showing 31–43 of 43 results
| Brand | OMECK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DS-1000 |
| Pricing | Upon Request |
| Application Field | General Particle Characterization |
| Instrument Type | Dynamic |
| Lens Count | Lensless Imaging System |
| Measurement Range | 1.4–1400 µm |
| Dispersion Method | Wet Dispersion |
| Image Resolution | 2 Megapixels |
| Primary Measured Parameter | Equivalent Projected Area Diameter (D<sub>EA</sub>) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | DIA-10 |
| Instrument Type | Dynamic |
| Number of Lenses | 1 |
| Measurement Range | 5–100 µm |
| Dispersion Method | Wet Dispersion |
| Measured Parameters | Area-equivalent Diameter, Perimeter-equivalent Diameter, Maximum Length, Maximum Orthogonal Length, Feret Diameter (Vertical), Feret Diameter (Horizontal), Particle Perimeter, Convex Hull Perimeter, Circularity, Aspect Ratio, Bounding Rectangle Aspect Ratio |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Imported |
| Model | QICPIC & MIXCEL |
| Instrument Category | Dynamic Image-Based Particle Analyzer |
| Number of Lenses | 6 |
| Measurement Range | 1–3000 µm |
| Dispersion Method | Wet Dispersion |
| Camera Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter, Sphericity, Aspect Ratio, Convexity, Straightness, Elongation, Perimeter Equivalent Diameter (PED), LEFI, DIFI, VBFD |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Imported Industrial-Grade Dynamic Image Analyzer |
| Model | QICPIC & FLOWCELL |
| Optical Configuration | Dual-lens imaging system |
| Measurement Range | 11–16,000 µm |
| Dispersion Method | Wet dispersion via external recirculation |
| Image Resolution | 4.2 MP (high-fidelity monochrome CMOS sensors) |
| Measured Parameters | Chord length, Feret diameters (max/min/mean), fiber length & diameter, equivalent circular diameter (ECD), sphericity, aspect ratio (width-to-length), convexity, flatness, elongation, LEFI/DIFI/VBFD indices, projected area diameter (PED) |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Dynamic Image-Based Particle Analyzer |
| Model | QICPIC & GRADIS |
| Lens Count | 5 |
| Measurement Range | 1.8–33,792 µm |
| Dispersion Method | Free-Fall Gravity Dispersion |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter (ECD), Circularity (Sphericity), Aspect Ratio, Convexity, Flatness, Elongation, LEFI, DIFI, VBFD, PED |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Dynamic Image-Based Particle Analyzer |
| Model | QICPIC & LIXELL |
| Lens Count | 6 |
| Measurement Range | 1–2000 µm |
| Dispersion Method | Wet Dispersion (External Circulation) |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter (ECD), Sphericity, Aspect Ratio, Convexity, Flatness, Elongation, Light Extinction Feret Index (LEFI), Dynamic Image Feret Index (DIFI), Volume-Based Feret Diameter (VBFD), Projected Area Diameter (PED) |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Type | Import |
| Model | QICPIC & RODOS/L |
| Instrument Category | Dynamic Image-Based Particle Analyzer |
| Number of Lenses | 5 |
| Measurement Range | 1.8–33,792 µm |
| Dispersion Method | Pneumatic (Compressed Air) |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter, Sphericity, Aspect Ratio, Convexity, Flatness, Elongation, Perimeter-Weighted Diameter (PED), Length-to-Width Ratio (L/W), VBFD (Volume-Based Fiber Dimension), LEFI/DIFI |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | QICPIC |
| Instrument Type | Dynamic |
| Measurement Range | 0.55–33,792 µm |
| Number of Lenses | 7 |
| Dispersion Method | Dry or Wet |
| Image Resolution | 4 Megapixels |
| Measured Parameters | Chord Length, Feret Diameter, Martin Diameter, Equivalent Spherical Diameter, Sphericity, Aspect Ratio |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Winner100D |
| Price Range | USD 1,400 – 42,000 |
| Instrument Type | Dynamic |
| Number of Lenses | 4 |
| Measurement Range | 1–3000 µm |
| Dispersion Method | Wet Dispersion |
| Image Resolution | 1920×1080 |
| Measured Parameters | Area-equivalent diameter, perimeter-equivalent diameter, Martin diameter, perimeter, projected area, particle length, particle width, estimated surface area, estimated volume, X-tangent, Y-tangent, tangent diameter, sphericity, aspect ratio |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | WINNER208 |
| Price Range | USD 1,400 – 42,000 |
| Application Category | Construction Materials Testing |
| Instrument Type | Static Image-Based Analyzer |
| Number of Lenses | 2 |
| Measurement Range | 1–3000 µm |
| Sample Dispersion Method | Wet Dispersion |
| Image Resolution | 3264 × 2448 |
| Measured Parameters | Area-equivalent diameter, Perimeter-equivalent diameter, Martin diameter, Perimeter, Projected area, Particle length, Particle width, Estimated surface area, Estimated volume, X-tangent, Y-tangent, Tangent diameter, Sphericity, Length-to-width ratio |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | Winner219 |
| Price Range | USD 1,400 – 42,000 |
| Application Classification | General Industrial & Research |
| Instrument Type | Static/Dynamic Hybrid |
| Number of Lenses | 2 |
| Measurement Range | 1–3000 µm |
| Dispersion Method | Wet Dispersion |
| Image Resolution | 1920×1080 |
| Measured Parameters | Area-equivalent Diameter, Perimeter-equivalent Diameter, Martin Diameter, Perimeter, Projected Area, Particle Length, Particle Width, Estimated Surface Area, Estimated Volume, X-tangent, Y-tangent, Tangent Diameter, Sphericity, Aspect Ratio |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | WINNER300D |
| Quotation | Upon Request |
| Instrument Type | Dynamic |
| Measurement Range | 10–10,000 µm |
| Sample Dispersion Method | Electromagnetic Vibration + Ultrasonic Dispersion |
| Measured Parameters | Particle Size Distribution, Sphericity, Aspect Ratio |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Winner300D Pro |
| Price Range | USD 1,400 – 42,000 (FOB) |
| Application Sector | Petrochemical Industry |
| Instrument Type | Dynamic Imaging Analyzer |
| Number of Lenses | 4 (including 0.3× and 1× telecentric objectives) |
| Measurement Range | 10–10,000 µm |
| Dispersion Method | Air Jet Dispersion + Free-Fall Feeding + Ultrasonic Separation |
| Image Resolution | 3000 × 2000 pixels |
| Measured Morphological Parameters | Sphericity, Circularity, Roundness, Aspect Ratio |
| Accuracy Error | <3% |
| Repeatability Error | <3% |
| Particle Analysis Throughput | >1,000,000 particles/min |
| CCD Sensor | 1/1.8-inch format, 39 fps |
| Illumination | High-Brightness LED Parallel Planar Light Source |
| Feeding Mechanism | Electromagnetic Vibratory Feeder with Digital Speed Control |
