Infrared Spectrometer
Filter
Showing 61–90 of 90 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TruDefender FT |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared Spectroscopy |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 2 scans/sec |
| Weight | 1.3 kg |
| Dimensions | 19.6 × 11.2 × 5.3 cm |
| Optical Interface | Diamond ATR Crystal |
| Environmental Rating | MIL-STD-810F & IP67 |
| Battery Life | >4 hours (rechargeable Li-ion or CR123A primary cells) |
| Operating Temperature | −25 °C to +40 °C |
| Data Export Formats | SPC, TXT, JPEG |
| Compliance | ASTM E2534 (for field-deployable chemical ID), GLP/GMP-ready audit trail support in firmware |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruDefender FTX |
| Instrument Category | Fourier Transform Infrared (FTIR) |
| Form Factor | Portable |
| Wavenumber Range | 4,000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Signal-to-Noise Ratio | ≥1,000:1 (typical, 32 scans, ambient conditions) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet iS10 |
| Instrument Type | Fourier Transform |
| Compliance Standards | ASTM E1421, NIST-traceable, USP <1119>, EP 2.2.24, JP 2.07, FDA 21 CFR Part 11 (with ValPro™ and OMNIC Security Suite) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS20 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | Not specified (custom-configurable per application) |
| Spectral Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 50,000:1 (at 4 cm⁻¹, 1 min scan, KBr beam splitter) |
| Wavenumber Accuracy | ±0.02 cm⁻¹ at 2000 cm⁻¹ |
| Optical Engine | LightDrive™ Interferometer Platform |
| Warranty | 10-year limited warranty on interferometer, laser, and IR source |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS5 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 350–7800 cm⁻¹ |
| Spectral Resolution | Better than 0.8 cm⁻¹ |
| Scan Speed | Up to 10 scans per second |
| Signal-to-Noise Ratio (SNR) | > 1 × 10⁵ (peak-to-peak, 4 cm⁻¹ resolution, 1 min scan) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nicolet iS50 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 27,000–15 cm⁻¹ |
| Spectral Resolution | Better than 0.09 cm⁻¹ |
| Scan Speed | 0.158 cm/s (slow), 6.28 cm/s (fast) |
| Signal-to-Noise Ratio | >55,000:1 (1-minute acquisition) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet™ iS50 FTIR |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Dimensions (Base Only) | 62.6 × 69.8 × 27.6 cm |
| Weight (Base Only) | 60 kg |
| Dimensions (with ABX) | 62.6 × 69.8 × 50.8 cm |
| Weight (with ABX) | 64 kg |
| Optical Path | Fully Gold-Coated Optics (Aluminum Coating Optional) |
| Light Sources | Dual-source Configuration (Polaris™ Long-Life IR Source + Tungsten-Halogen Visible/NIR Source) |
| Detectors | Three Detector Ports in Main Sample Compartment |
| Standard Features | Automated Attenuator Wheel, Smart Accessories Compatibility, Built-in Calibration Wheel, Parallel & Focused Beam Output Ports |
| Optional Modules | Integrated Mid- and Far-IR Diamond ATR, Automatic Beamsplitter Exchange (ABX), Raman Module, NIR Module with Integrating Sphere & Fiber Optics, TGA-IR Interface, GC-IR Interface |
| Software Platform | OMNIC Spectroscopy Suite with OMNIC Anywhere Cloud Integration |
| Data Security | AWS-Hosted Thermo Fisher Connect Platform |
| Compliance | Supports 21 CFR Part 11–compliant audit trails (via OMNIC Enterprise), GLP/GMP-ready workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory FT-IR Spectrometer |
| Model | Summit |
| Instrument Type | Benchtop FT-IR |
| Wavenumber Range | 8,000–350 cm⁻¹ |
| Spectral Resolution | < 0.6 cm⁻¹ (optimizable to 0.4 cm⁻¹) |
| Signal-to-Noise Ratio | 45,000:1 (standard), up to 48,000:1 (optional) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ at 2,000 cm⁻¹ |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop FTIR |
| Spectral Range | 7800–375 cm⁻¹ |
| Resolution | ≤1 cm⁻¹ (0.5 cm⁻¹ optional) |
| Scan Speed | Microprocessor-Controlled, 6 Adjustable Speeds |
| Signal-to-Noise Ratio | 30,000:1 (RMS, 2100 cm⁻¹, 4 cm⁻¹ resolution, DLATGS detector, 1-min acquisition) |
| Beam Diameter | 30 mm |
| Sample Aperture | 5 mm Ø |
| Interferometer | Self-Compensating Michelson with Active Alignment |
| Detector | Imported Low-Noise DLATGS |
| Source | Imported Long-Life Air-Cooled Ceramic IR Source |
| Beamsplitter | Multi-Layer KBr |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Linearity | ≤0.1% T |
| Data Interface | USB 2.0 |
| Dimensions (W×D×H) | 555 × 445 × 118 mm |
| Weight | 22 kg |
| Power | AC 90–230 V, 40 W |
| Operating Environment | 15–28 °C, <65% RH |
| Software Platform | Windows 98/2000/XP/Vista (32-bit) |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–375 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Scan Speed | Microprocessor-Controlled, 6 Adjustable Speed Settings |
| Signal-to-Noise Ratio (S/N) | 15,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Beam Splitter | 60 mm Ge-coated KBr with Hydrophobic Coating |
| Optics | Fully Gold-Coated Mirrors |
| Interferometer | Rocking-Mirror Interferometer (Space-Derived Design) |
| Environmental Protection | Integrated Heated Desiccant Chamber with Visual Indicator & Dual-Seal Enclosure |
| Purge Interface | Standard N₂ Purge Port |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP Audit Trail, Electronic Signatures, Role-Based Access Control |
| Brand | Topo |
|---|---|
| Model | FTIR920N |
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Pricing | Available Upon Request |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory FTIR |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | Up to 1 scan per 2 seconds (microprocessor-controlled) |
| Signal-to-Noise Ratio | 30,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector not included) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Brand | Topo |
|---|---|
| Model | FTIR 931 |
| Type | Portable FTIR Spectrometer |
| Wavenumber Range | 7800–375 cm⁻¹ |
| Resolution | ≤1 cm⁻¹ (down to 0.5 cm⁻¹) |
| Signal-to-Noise Ratio (S/N) | ≥15,000:1 (at 4 cm⁻¹, 1 min scan) |
| Scan Speed | Microprocessor-controlled, 6 selectable speeds |
| Beam Diameter | 30 mm |
| Sample Beam Spot | 5 mm Ø |
| Beamsplitter | Multi-layer coated KBr |
| Detector | Imported low-noise DLATGS |
| Source | Imported long-life, high-intensity air-cooled ceramic IR source |
| Interferometer | Laser-controlled automatic alignment and frequency calibration (He–Ne reference laser) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Linearity | ≤0.1% T |
| Aperture Ratio | f/3.2 |
| Data Interface | USB 2.0 |
| Dimensions (W×D×H) | 490 × 390 × 200 mm |
| Weight | 18 kg |
| Power Supply | 90–230 V AC / 12 V DC, 40 W |
| Operating Temperature | 15–28 °C |
| Relative Humidity | <65% RH (non-condensing) |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible operation environment |
| Software | Windows 32-bit compatible (Win 98/2000/XP/Vista), FDA 21 CFR Part 11–ready audit trail & user access control modules included |
| Brand | Topo/TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TJ270-30A |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Dispersive |
| Configuration | Laboratory Benchtop |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Spectral Resolution | 1.5 cm⁻¹ |
| Scan Speed | Five Adjustable Settings |
| Signal-to-Noise Ratio | 15,000:1 |
| Brand | TuoPu (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Spectral Range | 7800–375 cm⁻¹ |
| Spectral Resolution | 1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 15,000:1 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WQF-520 |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fourier Transform |
| Spectral Range | 7800–350 cm⁻¹ (KBr), 5000–500 cm⁻¹ (ZnSe) |
| Resolution | 0.9 cm⁻¹ |
| Signal-to-Noise Ratio | ≥50,000:1 |
| Wavenumber Accuracy | ≤0.005 cm⁻¹ |
| Interferometer | Integrated Cube-Corner Mirror Design, Permanent Alignment, >10-Year Lifetime |
| Detector | Moisture-Resistant High-Sensitivity DLaTGS with Built-in ADC |
| Source | Long-Life Mid-IR Ceramic Source (1550 K) |
| ATR Crystal | Single-Crystal Diamond |
| Dimensions (H×W×D) | 210 × 310 × 215 mm |
| Weight | 8 kg |
| Brand | ZOLIX |
|---|---|
| Model | FI-RXF100-G |
| Instrument Type | Portable FTIR Gas Analyzer |
| Spectral Range | 500–5000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ (software-selectable: 2, 4, or 8 cm⁻¹) |
| Optical Design | Michelson Interferometer with Solid-Angle Retroreflector Mirrors |
| Beam Splitter | ZnSe, Anti-Humidity Coated |
| Detector Options | DTGS (ambient-temperature), Thermoelectrically Cooled MCT, or Liquid-Nitrogen-Cooled MCT |
| Light Source | Air-Cooled Mid-IR Ceramic Source (1550 K) |
| Laser | Solid-State Stabilized Reference Laser (≥10 yr lifetime) |
| Gas Cell | Multi-Pass Stainless Steel Cell (5–9.8 m pathlength, heated to 180 °C) |
| System Dimensions (L×W×H, excl. handles) | 590 × 430 × 176 mm |
| Weight | 18 kg (fully integrated configuration) |
| Response Time (T₉₀) | <120 s |
| Spectral Repeatability | <0.01 cm⁻¹ |
| Linearity Error | ≤±2% F.S. |
| Sampling Modes | Single-shot, Continuous, or Automated Sequence Acquisition |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Spectral Resolution | < 0.4 cm⁻¹ |
| Wavenumber Accuracy | < 0.005 cm⁻¹ |
| Spectral Range | 8000–350 cm⁻¹ (standard), optional 5000–500 cm⁻¹ |
| Interferometer | Cube-corner Retroreflector Michelson Interferometer |
| Beam Splitter | Hygroscopic-resistant ZnSe |
| Detector Options | High-sensitivity DLaTGS, TE-cooled MCT, or Liquid-nitrogen-cooled MCT |
| Laser Source | Solid-state HeNe laser (10+ year lifetime) |
| Optical Mirrors | Gold-coated (reflectivity >98% above 2 µm, +5% vs aluminum) |
| Dimensions (L×W×H) | 685 × 415 × 223 mm |
| Weight | 25 kg |
| Sample Compartment | Large-volume, modular, fully accessible for in situ accessories |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 8000–350 cm⁻¹ / 5000–500 cm⁻¹ |
| Spectral Resolution | ≤0.4 cm⁻¹ |
| Wavenumber Accuracy | ≤0.005 cm⁻¹ |
| Interferometer | Domestic High-Stability Cubic Corner Retroreflector Interferometer |
| Beamsplitter | ZnSe (Moisture-Resistant), Optional KBr |
| Detectors | Liquid-N₂-Cooled MCT (≥10 h hold time), DLaTGS (Room-Temperature, Humidity-Resistant) |
| Scan Speed Options | 2.5K–60K points/sec (6 selectable steps) |
| Software | Windows 10–Based Native Chinese GUI with ASTM E1421–compliant spectral processing, automated channel switching, K-M transformation, background validity tracking, and GLP-ready audit trail logging |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop FTIR Emission Spectrometer |
| Spectral Range | Standard 500–5000 cm⁻¹ (Optional: 400–7500 cm⁻¹, 400–10000 cm⁻¹, or extended to 12500 cm⁻¹ in NIR) |
| Spectral Resolution | <2 cm⁻¹ (Typical operational resolution: 8 cm⁻¹) |
| Detector Configuration | Dual-detector mounting positions (RT DTGS, liquid-N₂-cooled MCT, or InGaAs) |
| Optical Path | Selectable focused or collimated beam path |
| Beam Splitter | ZnSe substrate (standard) |
| Interferometer | Permanently aligned Michelson interferometer with solid-state laser reference |
| Power Supply | 100–240 VAC, 50–60 Hz, 20 W |
| Dimensions | 44 × 33 × 18 cm (W×D×H, including emission baffle) |
| Weight | 12 kg |
| Operating Environment | 5–40 °C, 0–100% RH |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | FI-RXF100-RT |
| Price Range | USD 35,000 – 42,000 |
| Instrument Type | Fourier Transform Infrared (FTIR) |
| Configuration | Benchtop Laboratory System |
| Detector Options | DLaTGS or MCT |
| Optical Window Pathlengths | 30 µm, 50 µm, 100 µm, 200 µm, and custom pathlengths |
| Transmission Module Design | Motorized 5-position rotating turret (4 sample positions + 1 cleaning position) |
| Crystal Material | High-transmission ZnSe |
| Rotation Control | Bidirectional (CW/CCW) with mechanical indexing pins for positional repeatability < ±0.1° |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fourier Transform |
| Spectral Resolution | ≤0.25 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | ≥55,000:1 |
| Wavenumber Accuracy | ±0.005 cm⁻¹ |
| Spectral Range (Standard) | 8000–350 cm⁻¹ |
| Extended Range (Optional) | 12800–4000 cm⁻¹ |
| Interferometer | Cube Corner Retroreflector-Based Michelson Design |
| Detector Interface | Dual-Channel 32-bit ADC Architecture |
| Standard Detector | Room-Temperature DLaTGS |
| Optional Detectors | Liquid-Nitrogen-Cooled MCT, TE-Cooled MCT, LN₂-Cooled InSb, TE-Cooled InGaAs, LN₂-Cooled Ge |
| Beam Splitter Options | Ge-Coated KBr, Quartz, CaF₂, ZnSe |
| Source Options | Ceramic Globar, Tungsten-Halogen |
| Sample Compartment | Transmission-Compatible with Vacuum/N₂-Purged External Ports |
| Optional Accessories | TGA-FTIR Coupling Module, GC-FTIR Interface, UHV-Ready External Chamber, Gas Cells (2 cm–20 m), Integrating Sphere, In Situ Transmission/DRIFTS Cells, Micro-FTIR, ATR Probes (Including Mid-IR Fiber ATR), Specular Reflection Stage |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fourier Transform |
| Spectral Resolution | ≤0.25 cm⁻¹ |
| Wavenumber Accuracy | <0.01 cm⁻¹ |
| Vacuum Level | ≤0.2 mbar |
| Spectral Range (Standard) | 6000–50 cm⁻¹ |
| Extended Range | 12500–10 cm⁻¹ |
| Interferometer | Domestic High-Stability Retroreflector-Based Interferometer |
| Beam Splitter Options | KBr, CaF₂, Quartz, ZnSe |
| Detector Options | DLaTGS (standard), InGaAs, MCT, Liquid-He-Cooled Bolometer |
| Light Source Options | Ceramic IR Source (standard), Water-Cooled Hg Arc Lamp, Tungsten Filament Lamp |
| ATR Accessory | Diamond Crystal (Vacuum-Compatible) |
| Software | Windows 10–Based Full Chinese GUI with Spectral Library Management, Quantitative Analysis, and Automated CO₂/H₂O Subtraction |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Spectral Range | 5000–500 cm⁻¹ (ZnSe anti-humidity version) |
| Spectral Resolution | < 0.9 cm⁻¹ |
| Wavenumber Accuracy | < 0.01 cm⁻¹ |
| Interferometer | Domestic high-stability立体角镜 interferometer with permanent alignment |
| Beam Splitter | Ge-coated KBr, optimized for mid-IR |
| Detector | Fast-response pyroelectric detector |
| IR Source | High-energy SiN mid-IR source |
| Laser | Solid-state diode laser (>10 yr lifetime) |
| Environmental Sealing | Integrated desiccant system with real-time internal T/RH monitoring and auto-humidity alarm |
| Dimensions | 17 × 39.5 × 22.3 cm |
| Connectivity | Ethernet interface |
| Power | 100–240 VAC, 50–60 Hz |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Spectral Resolution | <1 cm⁻¹ |
| Wavenumber Accuracy | <0.01 cm⁻¹ |
| Spectral Range | 5000–500 cm⁻¹ |
| Interferometer | Domestic High-Stability Cubic Corner Retroreflector Interferometer (Lifetime >10 years) |
| Beam Splitter | ZnSe for Mid-IR, Humidity-Resistant |
| Detector | Desiccated High-Sensitivity DLaTGS with Integrated ADC |
| Light Source | Long-Life Mid-IR Ceramic Source |
| Laser | Solid-State Laser (Lifetime >10 years) |
| ATR Crystal | Monolithic Diamond Embedded in Passivated Stainless Steel |
| Display | 7-inch Capacitive Touchscreen Running Windows 10 |
| Battery | Rechargeable Li-ion, 4 h Continuous Operation |
| Power Input | 100–240 VAC, 50–60 Hz |
| Dimensions | 260 × 163 × 128 mm (with auto-pressure ATR head) |
| Weight | <4.5 kg |
| Operating Temperature | −10 °C to +40 °C |
| Storage Temperature | −20 °C to +55 °C |
| Environmental Sealing | Integrated Desiccant Dry Tube + Real-Time Internal Humidity/Temperature Monitoring & Alert |
| Connectivity | Wi-Fi 802.11ac, Bluetooth 5.0, USB-C Data/Charging Port |
| Onboard Camera | Integrated for Sample Imaging |
| Software | Fully Localized Chinese FTIR Analysis Suite with Automated “Acquire–Analyze–Report” Workflow |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FT-IR) |
| Spectral Resolution | 1 cm⁻¹ |
| Spectral Range | 500–5000 cm⁻¹ |
| Interferometer | Cube Corner Michelson Interferometer |
| IR Source | Air-Cooled Ceramic Source |
| Beam Splitter | Zinc Selenide (ZnSe) |
| Detector | High-Sensitivity DLATGS |
| ATR Sampling | Single-Bounce Diamond ATR |
| Operating Temperature | −5 to 40 °C |
| Operating Humidity | 0–100% RH |
| Weight | 10 kg |
| Dimensions | 41 × 32 × 17 cm |
| Battery Life | Up to 4 hours (internal Li-ion) |
| Power Input | 18–24 V DC (vehicle battery compatible) or 100–240 V AC, 50–60 Hz, 20 W |
| Control Interface | 10-inch capacitive touchscreen (Windows 10 OS optional) |
| Reference Libraries | Hazardous Chemicals, Explosives, Narcotics, Pesticides, Pharmaceuticals, White Powders, Gases |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 5000–500 cm⁻¹ (FOLI 20-Z) / 7500–400 cm⁻¹ (FOLI 20-ZE) |
| Resolution | ≤2 cm⁻¹ |
| Wavenumber Accuracy | ≤0.01 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | ≥40,000:1 (at 4 cm⁻¹, 1 min scan) |
| Transmittance Accuracy | ≤0.1% τ |
| Beam Splitter | ZnSe (standard) or KBr (FOLI 20-ZE models) |
| Detector | Standard DLaTGS |
| Laser | Solid-state He–Ne reference laser |
| Dimensions | 550 × 450 × 230 mm |
| Weight | 20 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Laboratory-grade Infrared Spectral Analyzer |
| Model | Omni-λ300i |
| Wavenumber Range | 4000–25000 cm⁻¹ |
| Spectral Resolution | 0.08 nm (with 1200 g/mm grating) |
| Signal-to-Noise Ratio | 8000:1 |
| Stray Light Level | ≤1×10⁻⁵ |
| Focal Length | 320 mm |
| f-number | f/4.2 |
| Optical Design | Czerny-Turner with Aspheric Image Correction |
| Grating Size | 68×68 mm |
| Grating Tower | Triple-grating turret |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Slit Width Adjustment | 0.01–3 mm (manual or motorized option) |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Wavelength Accuracy | ±0.15 nm |
| Wavelength Repeatability | ±0.08 nm |
| Minimum Scan Step | 0.005 nm |
| Dispersion | 2.3 nm/mm (at 435.8 nm) |