Infrared Spectrometer
Filter
Showing 31–60 of 186 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | INVENIO |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 8,000 – 350 cm⁻¹ |
| Spectral Resolution | 0.16 cm⁻¹ |
| Scan Speed | 20 spectra/sec |
| Signal-to-Noise Ratio | >10,000:1 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | LUMOS II ILIM |
| Instrument Type | Laboratory-based Laser IR Microscope |
| Instrument Category | FTIR Imaging Microscope with Integrated Laser Illumination Module |
| Application Domain | Chemical Imaging, Spatially Resolved Spectroscopy, Hyperspectral Mapping |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| FT-IR Architecture | Interferometric (Michelson-type) |
| Wavenumber Range | 6000 – 670 cm⁻¹ |
| Detector | Thermoelectrically Cooled MCT (TE-MCT), No Liquid Nitrogen Required |
| Enclosure Rating | IP65 (Instrument Body), IP67 (Carrying Case) |
| Light Source | CenterGlow™ Broadband IR Source (Lifespan >5 years) |
| Interferometer | RockSolid™ Dynamic Alignment-Free Design (Lifespan >10 years) |
| Laser | Solid-State Diode Laser (Lifespan >10 years) |
| ATR Accessory | Heated Diamond Crystal |
| Power Supply | Integrated Rechargeable Lithium Battery (Field-Operable, Grid-Independent) |
| Software Platform | OPUS TOUCH™ (Touch-Optimized, Role-Based Workflow Interface) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | oIR3-s |
| Instrument Type | Laboratory-Based Fourier Transform Infrared Spectrometer |
| Wavenumber Range | 900–3600 cm⁻¹ |
| Spatial Resolution | <10 nm |
| Spectral Resolution | <1 cm⁻¹ |
| Acquisition Speed | 10 s per spectrum |
| Signal-to-Noise Ratio | 200:1 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory FTIR Spectrometer |
| Model | Tensor 27 |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Condition | Professionally Refurbished |
| Compliance | Meets ISO/IEC 17025 calibration traceability standards for used analytical instrumentation |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX 70v |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 10–30,000 cm⁻¹ |
| Spectral Resolution | ≤0.4 cm⁻¹ (standard), upgradable to 0.16 cm⁻¹ |
| Scan Speed | 80 scans/sec |
| Signal-to-Noise Ratio | 50,000:1 (at 4 cm⁻¹, 1 min measurement) |
| Interferometer | RockSolid™ permanently aligned, gold-coated optics |
| Vacuum Capability | Full-vacuum optical bench optional |
| Beam Splitter Exchange | Motorized BMS-c unit supports up to 4 beam splitters without breaking vacuum |
| Detector Compatibility | Up to 5 software-controlled detectors (RT, LN₂-cooled, LHe-cooled) |
| Compliance | ASTM E1421, ISO 17025, USP <851>, FDA 21 CFR Part 11 (with OPUS software suite) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX 80 / VERTEX 80v |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 50000–5 cm⁻¹ |
| Spectral Resolution | < 0.06 cm⁻¹ |
| Scan Speed | 115 scans/sec |
| Signal-to-Noise Ratio | 55,000:1 |
| Interferometer | UltraScan™ True-Alignment Patent Interferometer |
| Optical Platform | Fully Vacuum-Compatible Cast-Aluminum Base (VERTEX 80v) |
| Data Acquisition | DigiTect™ Digital Detection Technology |
| Beam Splitter Exchange | Automated, Vacuum-Compatible BMS-c |
| Detector Channels | Dual-Channel, 24-bit High-Speed ADC |
| Light Sources | Integrated Air-Cooled Source + Optional External Water-Cooled High-Power Source |
| Beam Ports | 5 Output Ports + 2 Input Ports |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX NEO R |
| Instrument Type | Laboratory FTIR Spectrometer |
| Vacuum Capability | Full Vacuum Optical Bench |
| Interferometer | RockSolid™ Permanent Alignment |
| Detector Technology | MultiTect™ Multi-Element Detector Platform |
| Instrument Class | Research-Grade FTIR |
| Compliance | Designed for ASTM E1421, ISO 17025-compliant laboratories, GLP/GMP-ready configuration options |
| Software | OPUS 8.5 with FDA 21 CFR Part 11–compliant audit trail and electronic signature modules |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory FTIR |
| Model | VERTEX NEO Ultra |
| Spectral Resolution | 0.04 cm⁻¹ |
| Vacuum Operation | Yes |
| Detector Configuration | Up to 6 integrated detectors (MultiTect) |
| Beam Path Environment | Fully evacuated optical bench |
| ATR Capability | Vacuum-compatible attenuated total reflection module |
| Scan Modes | Step-scan (μs–ns–ms dynamics), Rapid-scan |
| Interferometer | UltraScan with linear air-bearing mirror drive |
| THz Extension | verTera module compatible |
| Optical Path Flexibility | 5 output ports, 4 beam splitters, 4 sources, 6 detectors — all switchable under vacuum |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | OP-FTIR |
| Pricing | Upon Request |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0916 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | Better than 1.0 cm⁻¹, continuously adjustable |
| Signal-to-Noise Ratio | 30,000:1 (peak-to-peak, 4 cm⁻¹, 1-minute scan) |
| Beam Splitter | Ge-coated KBr substrate |
| Source | High-energy, long-life IR source with auto-sleep function |
| Interferometer | Magnetically suspended planar mirror, electromagnetic drive Michelson interferometer (30° incidence angle) |
| Detector | Moisture-resistant high-sensitivity DLATGS detector |
| Quantification Method | FAME concentration calculated from absorbance at 1745 cm⁻¹ using ASTM D7371-compliant calibration |
| Interface | USB 2.0 high-speed bidirectional port |
| OS Compatibility | Windows XP through Windows 10 |
| Brand | Cloudoptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform Infrared (FTIR) & Raman Spectrometer |
| Model | DRF-600 |
| Compliance | CE, RoHS, ISO/IEC 17025–compatible operation environment |
| Brand | Cloudoptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Model | FTIR-800 |
| Key Specifications | ATR-based micro-FTIR optical architecture, solid/liquid sample compatibility, multi-component identification capability (≥3 components), fluorescence-insensitive detection, thermal-sensitive & energetic material compatible |
| Compliance | Designed to support field-deployable GLP-aligned workflows |
| Brand | D&P |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 102F |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Spectral Range | 2–16 μm |
| Spectral Resolution | Adjustable at 4, 8, or 16 cm⁻¹ |
| Wavenumber Accuracy | ±1 cm⁻¹ across full spectral range |
| Scan Speed | 1 spectrum/sec (nominal, at 4 cm⁻¹ resolution) |
| Detector | Dual-element InSb/MCT |
| Standard Lens | 1″ aperture (FOV 4.8°) |
| Calibration Sources | Integrated hot/cold blackbody references |
| Dimensions | 36 cm × 20 cm × 23 cm |
| Weight | 7 kg |
| Brand | D&P |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Turbo FT |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Spectral Range | 2.5–16 µm (optional 1.7–16 µm) |
| Spectral Resolution | 4 cm⁻¹ (adjustable) |
| Scan Speed | 25–100 spectra/sec @ 4 cm⁻¹ |
| Maximum Continuous Acquisition | 1,000,000 spectra (gapless or sequential file mode) |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Optical Design | Michelson Interferometer with KBr Beamsplitter and Dynamically Aligned Mirror Drive |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IR5 |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.5 cm⁻¹ |
| Detector Options | Standard DTGS |
| Software Platform | Miracle™ v5.x |
| Optional Module | FT-PL (Fourier Transform Photoluminescence) with Integrated Laser Excitation Source |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ATROP-VA |
| Pricing | Available Upon Request |
| Brand | EXPEC / Spectrometer Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1680 |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Regulatory Compliance | HJ 920-2017, HJ 919-2017 |
| Target Analytes | >50 Inorganic & Organic Gases |
| Integrated Features | Heated Sample Path, Onboard Sampling System, GPS Geotagging, Touchscreen UI, Wi-Fi Connectivity, Auto Temperature Control, Remote Operation Capability |
| Brand | EXPEC / Superspectra Technology |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online FTIR Remote Sensor |
| Design | Open-Path, Non-Contact, Real-Time Chemical Imaging System |
| Core Detector | Stirling-Cooled MCT (Operating at –200 °C) |
| Gas Library Capacity | >400 Target Compounds (TICs, VOCs, Chemical Warfare Agents, Industrial Solvents) |
| Operational Range | Up to 10 km Diameter Coverage |
| Scanning Capability | 360° Azimuthal Rotation, ±30° Vertical Elevation (60° Total Vertical FOV) |
| Imaging Modalities | Simultaneous Visible Video, Thermal IR Imaging, and Quantitative Chemical Mapping |
| Compliance Framework | Designed for EPA Method 320 & ASTM D6348 Alignment |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Online FTIR Spectrometer |
| Interferometer Design | Patented "Double Cat’s Eye" Alignment System |
| Detector | High-Sensitivity Sealed DLATGS |
| Spectral Resolution | Standard ≤ 4 cm⁻¹ (configurable to ≤ 0.5 cm⁻¹) |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Signal-to-Noise Ratio | ≥ 30,000:1 (at 4 cm⁻¹, 1 min scan) |
| Environmental Protection | Integrated Desiccant Monitoring & Auto-Alert for Optical Chamber Humidity |
| Software Compliance | GLP-Ready, FDA 21 CFR Part 11–Compliant Audit Trail & Electronic Signature Support |
| Sample Compartment | Extra-Large Bore (≥ 180 mm Ø), Compatible with Pike Technologies ATR, DRIFTS, Gas Cells, Liquid Cells, and Microscope Modules |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | ≥30,000:1 (peak-to-peak, 4 cm⁻¹ resolution, 1-min scan, 2100 cm⁻¹) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Detector | Imported Pyroelectric Detector |
| Beamsplitter | Ge-coated KBr substrate with moisture-resistant coating |
| Source | Long-life, high-intensity air-cooled IR source |
| Data Interface | USB 2.0 |
| Operating System Support | Windows XP, Windows 7 |
| Dimensions | 450 × 350 × 210 mm |
| Weight | 14 kg |
| Brand | Gangdong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTIR-650 |
| Pricing | Available Upon Request |
| Optical System | Michelson Interferometer with KBr Beamsplitter |
| Detector | DTGS (Deuterated Triglycine Sulfate) |
| Spectral Range | 4000–400 cm⁻¹ (standard), extendable to 7800–375 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ (user-selectable down to 0.25 cm⁻¹) |
| Signal-to-Noise Ratio | >15,000:1 (at 4 cm⁻¹, 1 min scan, peak height) |
| Scan Speed | 0.2–2.0 cm/s (interferometer mirror velocity) |
| Aperture | Adjustable iris (2–10 mm) |
| Data Format | Standard JCAMP-DX v5.0 compliant |
| Compliance | Certified per JJG 812–2019 (China National Metrology Verification Regulation), Meets ISO/IEC 17025 requirements for spectral calibration traceability |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | Better than 1 cm⁻¹ |
| Scan Speed | 1 scan/sec |
| Signal-to-Noise Ratio | 45,000:1 (peak-to-peak, 4 cm⁻¹, 1-min background + sample scan, at 2100 cm⁻¹) |
| Detector | Imported High-Sensitivity DTGS or MCT (configurable) |
| Beamsplitter | Ge-coated KBr substrate |
| Source | Long-life Air-Cooled High-Intensity IR Source |
| Linearity | 0.1% |
| Dimensions | 430 × 360 × 200 mm |
| Weight | 15 kg |
| Interface | USB 2.0 |
| OS Support | Windows 7 Professional, Windows 10 Professional |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Instrument Architecture | Michelson Interferometer with Corner-Cube Retroreflectors |
| Optical Design | Double-Pass, Compensated Beam Path |
| Detector | High-Sensitivity DTGS with Optional MCT Upgrade |
| Spectral Range | 4000–400 cm⁻¹ (standard), extendable to 7800–350 cm⁻¹ |
| Resolution | ≤0.5 cm⁻¹ (user-selectable down to 0.25 cm⁻¹) |
| Signal-to-Noise Ratio | ≥30,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak) |
| Scan Speed | Up to 10 kHz mirror velocity |
| Data Acquisition | 24-bit ADC, 125 kHz sampling rate |
| Compliance | ASTM E1421, ISO 17025 (when operated in accredited labs), USP <1119>, GLP-compliant data integrity architecture |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop FTIR |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | < 0.5 cm⁻¹ |
| Scan Speed | 130,000 scans/sec (real-time dynamic mirror alignment) |
| Signal-to-Noise Ratio | 30,000:1 (at 4 cm⁻¹, 1-min scan) |
| Detector | Imported High-Sensitivity DLATGS |
| Beamsplitter | Ge-coated KBr substrate with hydrophobic anti-moisture layer |
| Laser Reference | He–Ne stabilized interferometer |
| Data Interface | USB 2.0 |
| Software Compliance | 21 CFR Part 11–ready audit trail, three-tier user permission architecture |
| Dimensions | 543 × 455 × 248 mm |
| Power Supply | AC 220 V / 50 Hz |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | Gangdong Technology Co., Ltd. |
| Model | TG-FTIR |
| Instrument Type | Laboratory Benchtop System |
| FTIR Spectral Range | 7800–350 cm⁻¹ |
| FTIR Resolution | 0.5 cm⁻¹ |
| Scan Speed | 130,000 scans/sec |
| Signal-to-Noise Ratio | 30,000:1 |
| Gas Cell Path Length | 100 mm |
| Gas Cell Material | Stainless Steel |
| Gas Cell Internal Diameter (max/center) | 28 mm / 16 mm |
| Gas Cell Volume | 38.5 mL |
| IR Window | 38 × 6 mm BaF₂ or KBr (standard) |
| Transfer Line | 3 mm OD × 1 m PTFE-sheathed heated tubing |
| Gas Cell Max Temp | 300 °C |
| Transfer Line Max Temp | 230 °C |
| Temp Control Accuracy | ±1.0 °C |
| Detector | Imported High-Sensitivity DLATGS (Deuterated L-Alanine Doped Triglycine Sulfate), Liquid-Nitrogen-Free Operation |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop |
| Spectral Range | 4000–400 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Scan Speed Options | 5 Adjustable Settings (Very Fast, Fast, Normal, Slow, Very Slow) |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan, DTGS detector) |
| Wavenumber Accuracy | ±4 cm⁻¹ (4000–2000 cm⁻¹), ±2 cm⁻¹ (2000–400 cm⁻¹) |
| Wavenumber Repeatability | ≤2 cm⁻¹ (4000–2000 cm⁻¹), ≤1 cm⁻¹ (2000–400 cm⁻¹) |
| Transmittance Accuracy | ±0.2%T (excluding noise floor) |
| Transmittance Reproducibility | ≤0.5%T (1000–930 cm⁻¹) |
| Baseline Flatness | ≤±0.2%T |
| Stray Light | ≤0.5%T (4000–650 cm⁻¹), ≤1.0%T (650–400 cm⁻¹) |
| Detector | Imported DTGS (Deuterated Triglycine Sulfate) |
| Data Interface | USB 2.0 |
| OS Compatibility | Windows XP, Windows 7 |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Product Type | Domestic |
| Model | Zhiview Smart |
| Price Range | USD 14,000–21,000 (FOB) |
| Instrument Category | Fourier Transform Type |
| Form Factor | Portable |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Scan Speed | Software-selectable via PC control |
| Signal-to-Noise Ratio | 20,000:1 (peak-to-peak, 4 cm⁻¹, 1-min scan at 2100 cm⁻¹) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BFH-200 |
| Price | USD 27,500 (FOB Guangzhou) |
| Spectral Range | 350–7800 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | 40,000:1 (peak-to-peak, 4 cm⁻¹, 1 min scan) |
| Light Source | Ge-coated KBr beam splitter (imported) |
| Interferometer | Non-orthogonal Michelson-type with DSP-controlled electromagnetic drive |
| Detector | DLATGS with anti-humidity coating (imported) |
| Operating Systems | Windows XP through Windows 10 (64-bit compatible) |
| Dimensions | 450 × 350 × 210 mm |
| Weight | 13 kg |