Infrared Thermometer
Filter
Showing 31–40 of 40 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Testo 830-T2 |
| Pricing | Available Upon Request |
| Contact-Free IR Measurement Range | −30 to +400 °C |
| Contact Thermocouple (Type K) Range | −50 to +500 °C |
| IR Resolution | 0.5 °C |
| IR Accuracy | ±1.5 °C or ±1.5% of reading (0.1–400 °C) |
| Contact Resolution | 0.1 °C |
| Contact Accuracy | ±(0.5 °C + 0.5% of reading) |
| Emissivity Adjustment | 0.2–1.0 (adjustable in 0.01 steps) |
| Optical Resolution | 12:1 |
| Brand | testo |
|---|---|
| Model | 830-T2 |
| Type | Portable Infrared Thermometer |
| Optical Resolution | 12:1 |
| Laser Targeting | Dual-point |
| Emissivity Adjustment | Yes |
| Temperature Range (IR) | –30 °C to +400 °C |
| Temperature Range (Contact Probe) | –50 °C to +500 °C |
| IR Accuracy | ±1.5 °C or ±1.5 % of reading (whichever is greater) from 0.1 °C to 400 °C |
| Contact Probe Accuracy | ±0.5 °C + 0.5 % of reading |
| IR Resolution | 0.1 °C |
| Contact Resolution | 0.1 °C |
| IR Response Time | 0.5 s |
| Contact Response Time | 1.75 s |
| Probe Type | K-type (NiCr–Ni) thermocouple |
| Display | Backlit LCD |
| Alarm Function | Dual user-defined high/low limits with audible and visual alert |
| Data Hold & Min/Max Tracking | Yes |
| Housing Material | ABS |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Operating Temperature | –20 °C to +50 °C |
| Storage Temperature | –40 °C to +70 °C |
| Power Supply | 9 V battery (included) |
| Battery Life | ~15 hours |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | testo 830-T4 |
| Instrument Type | Portable |
| Distance-to-Spot Ratio | 30:1 |
| Emissivity Adjustment | Adjustable (0.10–1.00) |
| Laser Aiming | Dual-point |
| Measurement Frequency | 2 Hz |
| IR Temperature Range | –30 to +400 °C |
| IR Accuracy | ±1.5 °C (–20 to 0 °C), ±2 °C (–30 to –20.1 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| Response Time (IR) | 0.5 s |
| Contact Probe Input | Type K thermocouple (–50 to +500 °C, ±0.5 °C + 0.5 %, resolution 0.1 °C, response time 1.75 s) |
| Display | Backlit LCD |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –40 to +70 °C |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Power Supply | 9 V alkaline battery |
| Battery Life | ~15 h |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 0563 8314 |
| Instrument Type | Portable |
| Distance-to-Spot Ratio | 30:1 |
| IR Temperature Range | -30 to +400 °C |
| IR Accuracy | ±1.5 °C (-20 to 0 °C), ±2 °C (-30 to -20.1 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| IR Response Time | 0.5 s |
| Contact Probe Type | Spring-loaded surface probe (Type K thermocouple, 0602 0393) |
| Contact Range | -50 to +500 °C |
| Contact Accuracy | ±0.5 °C + 0.5 % of reading |
| Contact Resolution | 0.1 °C |
| Contact Response Time | 1.75 s |
| Display | Backlit LCD |
| Laser Aiming | Dual-point |
| Emissivity Adjustment | Adjustable (0.10–1.00) |
| Alarm Function | Two user-defined limits with audible/visual alert |
| Data Hold & Min/Max Tracking | Yes |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Dimensions | 190 × 75 × 38 mm |
| Weight | 200 g |
| Power Supply | 9 V battery |
| Battery Life | ~15 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8351 |
| Type | Portable Infrared Thermometer |
| IR Temperature Range | –30 to +600 °C |
| IR Accuracy | ±2.5 °C (–30.0 to –20.1 °C), ±1.5 °C (–20.0 to –0.1 °C), ±1.0 °C (0.0 to +99.9 °C), ±1 % of reading (remaining range) |
| Optical Resolution | 50:1 |
| Emissivity Adjustment | 0.10–1.00 (20 preset values stored) |
| Contact Temperature Input | Type K thermocouple (–50 to +600 °C, ±0.5 °C + 0.5 % of reading) |
| Display | Backlit dot-matrix LCD |
| Data Storage | 200 measurement values |
| Interface | USB for PC connectivity |
| Power | 3 × AA batteries (25 h typical runtime, laser & backlight off) |
| Weight | 514 g |
| Dimensions | 193 × 166 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| Storage Temperature | –30 to +50 °C |
| Compliance | EN 61326-1:2006 (EMC), CE-marked |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8352 |
| Type | Portable Infrared Thermometer |
| IR Temperature Range | –10 to +1500 °C |
| IR Accuracy | ±2.0 °C or ±1 % of reading |
| Optical Resolution | 50:1 |
| Laser Aiming | 4-point visible laser |
| Emissivity Table | 20 pre-stored values |
| Data Storage | 200 measurements |
| Contact Probe Input | Type K thermocouple (–50 to +1000 °C) |
| Display | Backlit dot-matrix LCD |
| Weight | 514 g |
| Dimensions | 193 × 166 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| Battery | 3 × AA (25 h typical, no backlight/laser) |
| Compliance | EN 61326-1:2006 |
| Measurement Range (IR) | –60 °C to +500 °C |
|---|---|
| Measurement Range (Contact) | –60 °C to +1400 °C |
| Sensor Type | K-type thermocouple (TMDT 2–30, up to 900 °C) |
| Accuracy | ±2% of reading or ±2 °C (whichever is greater) |
| Response Time | 500–1000 ms |
| D | S Ratio: 11:1 |
| Spectral Range | 8–14 µm |
| Emissivity Adjustment | 0.1–1.0 (adjustable) |
| Display Resolution | 0.1 °C |
| Laser Class | II (635–650 nm, ≤1 mW) |
| Operating Temp. | 0 °C to 50 °C |
| Storage Temp. | –20 °C to +65 °C |
| Power | 2 × AAA (IEC LR03), 140 h (laser/backlight off) |
| Dimensions | 175 × 72 × 39 mm |
| Weight | 940 g |
| EMC Compliance | EN 61326-1:1997 + A1 + A2 |
| Laser Safety | CFR 1040.10 / IEC 60825-1 |
| Measurement Range | -60 °C to +500 °C |
|---|---|
| Accuracy | ±2% of reading or ±2 °C (whichever is greater) |
| Response Time | 500–1000 ms |
| D | S Ratio: 11:1 |
| Spectral Range | 8–14 µm |
| Emissivity | 0.95 (fixed) |
| Laser Type | Class 2, 635–650 nm, <1 mW |
| Display | LCD with 0.1 °C resolution and backlight |
| Operating Temperature | 0–50 °C |
| Storage Temperature | -20–65 °C |
| Power | 2 × AAA (LR03) alkaline batteries |
| Battery Life | ~18 hours |
| Auto-off | 15 seconds after trigger release |
| EMC Compliance | EN 61326-1:1997 +A1+A2 |
| Laser Safety | FDA 21 CFR 1040.10 / IEC 60825-1 |
| Brand | YORK |
|---|---|
| Origin | United Kingdom |
| Model | FTBB |
| Type | Portable |
| Cavity Aperture | 30 mm |
| Effective Emissivity | ≥0.999 |
| Spectral Range | (8–14) µm |
| Brightness Temperature Uncertainty | ≤0.07 °C (k=2) |
| Compliance | JJG856-2015, JJF1552-2015, JJF1187-2008, JJF1107-2003 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYKX-20 |
| Price Range | USD 1,400–7,000 (FOB) |
| Instrument Type | Online Continuous Monitoring System |
| Measurement Resolution | 0.1 °C |
| Accuracy | ≤ ±0.3 °C |
| Temperature Range | 33 °C to 43 °C (configurable alarm threshold) |
| Measurement Site | Forehead or wrist |
| Response Time | ≤ 1 s |
| Operating Ambient Temperature | 10 °C to 40 °C |
| Relative Humidity Limit | ≤ 85 % RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| External Frame Dimensions (H×W×D) | 2200 mm × 830 mm × 300 mm |
| Passage Opening (H×W×D) | 1920 mm × 700 mm × 300 mm |
| Installation Method | Tool-free quick-connect modular assembly |