| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PXSJ-216F |
| Instrument Type | Benchtop |
| Ion Measurement Range | (−2.000 to 20.000) pX |
| Resolution | 0.001 pX |
| Temperature Range | (−10.0 to 135.0) °C / (14.0 to 275.0) °F |
| Protection Rating | IP54 |
| Data Storage Capacity | 500 measurement sets |
| Calibration Points | 1–5 point pH calibration |
| Supported Ion Modes | Na⁺, K⁺, NH₄⁺, Cl⁻, F⁻ (user-definable) |
| Concentration Units | μg/L, mg/L, g/L, mol/L, mmol/L, pX |
| Measurement Methods | Direct concentration, Standard addition, Sample addition, Gran plot |
| Interface | RS-232, USB |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Benchtop Ion Analyzer |
| Ion Measurement Range | 1.00 × 10⁻⁹ to 9.99 × 10⁹ (selectable units: mol/L, mmol/L, g/L, mg/L, µg/L, ppm) |
| Detection Limit | Equivalent to measurement range |
| Response Time | ≤5 s |
| Accuracy Class | 0.001 |
| Temperature Range | −10.0 to 135.0 °C (14.0 to 275.0 °F) |
| mV Range | −2000.00 to +2000.00 mV |
| pH/pX Range | −2.000 to 20.000 |
| pH/pX Resolution | 0.001 |
| mV Resolution | 0.01 mV |
| Temperature Resolution | 0.1 °C/°F |
| Input Power | AC 100–240 V → DC 24 V |
| Dimensions | 220 × 195 × 68 mm |
| Weight | 0.95 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PXSJ-226T |
| Instrument Type | Benchtop |
| Ion Measurement Range | 1.00 × 10⁻⁹ to 9.99 × 10⁹ (selectable units: mol/L, mmol/L, g/L, mg/L, μg/L, ppm) |
| Detection Limit | 1.00 × 10⁻⁹ to 9.99 × 10⁹ (same unit options) |
| Response Time | ≤5 s |
| Accuracy Class | 0.001 |
| Temperature Range | −10.0 to 135.0 °C (14.0 to 275.0 °F) |
| Display | High-resolution color LCD touchscreen |
| Input Protection Rating | IP54 |
| Calibration | 1–6-point calibration for pH/ion electrodes |
| Compliance | GLP-compliant data management |
| Connectivity | RS-232, USB, optional auto-sampler interface |
| Data Storage | 1000 measurement records with timestamp, electrode ID, calibration history, and user log |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PXSJ-227L |
| Instrument Type | Benchtop |
| Ion Measurement Accuracy | 4 significant digits (scientific notation) |
| Temperature Range | −5.0 to 130.0 °C |
| Ion Modes Supported | H⁺, Na⁺, K⁺, NH₄⁺, Cl⁻, F⁻ (preloaded) |
| Calibration | Auto 1–6 point |
| Measurement Modes | Direct concentration, standard addition, sample addition, Gran plot method |
| Data Storage | 1,000 datasets per mode |
| Compliance | GLP-compliant data traceability |
| Connectivity | RS-232/USB for PC and USB flash drive |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | PXSJ-227L |
| Instrument Type | Benchtop |
| Ion Measurement Capability | Multi-ion (up to 4 simultaneous channels) |
| pH/pX Accuracy Class | 0.001-level |
| pH Range | −2.000 to 20.000 |
| pX Range | −2.000 to 20.000 |
| mV Range | −2000.00 to +2000.00 mV |
| Ion Concentration Range | 1.000 × 10⁻⁹ to 9.999 × 10⁹ (units: mol/L, mmol/L, g/L, mg/L, µg/L, ppm, ppb) |
| Temperature Range | −10.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C (0.0–60.0 °C), ±1.0 °C (remainder) |
| Data Storage | 1000 pH/ORP/pX/concentration records, 100 calibration sets, 1000 pH standard verification logs |
| Connectivity | RS-232, USB, optional autosampler interface |
| Compliance | GLP-compliant data handling, GMP-ready audit trail, FDA 21 CFR Part 11–compatible software architecture (via PC client) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PXSJ-270F |
| Instrument Type | Benchtop |
| Ion Measurement Range | (−2.00 to 20.00) pX |
| Measurement Accuracy | ±0.01 pX |
| Temperature Range | (−5.0 to 110.0) °C / (23.0 to 230.0) °F |
| Resolution Options | 0.01 pX / 0.1 pX |
| Temperature Unit Selection | °C or °F |
| Protection Rating | IP54 |
| Data Storage Capacity | 500 datasets |
| Connectivity | RS-232, USB |
| Compliance | GLP-compliant data management |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PXSJ-270F |
| Price Range | USD 150–750 (est.) |
| Instrument Category | Multi-Ion Analyzer |
| Form Factor | Benchtop |
| pX Measurement Range | (−2.00 to 20.00) pX |
| pX Accuracy | ±0.01 pX |
| Temperature Range | (−5.0 to 110.0) °C / (23.0 to 230.0) °F |
| pH Range | (−2.00 to 20.00) pH |
| pH Accuracy | ±0.01 pH |
| mV Range | (−2000.0 to +2000.0) mV |
| mV Resolution | 0.1 mV |
| Ion Concentration Units | mol/L, mmol/L, g/L, mg/L, μg/L |
| Data Storage Capacity | 500 datasets |
| Connectivity | RS-232, USB |
| IP Rating | IP54 |
| Compliance | GLP-compliant data logging with audit trail support |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Model | Aluminum Ion Detector |
| Type | Portable Multi-Ion Analyzer |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed for Field-Deployable Water Quality Monitoring per ISO 10523, ASTM D3590, and EPA Method 200.7 (ICP-OES reference correlation) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Quartz Crystal Microbalance (QCM) with Gold-Plated Fluoride-Specific Sensor Chip |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Regulatory Compliance | Designed for ISO 10523, ASTM D4192, and EPA Method 300.0–compatible workflows |
| Software Interface | USB-C–enabled embedded firmware with real-time data streaming and CSV export |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Endotoxin Detection System |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microfluidic Sensor Chip |
| Sensitivity | 0.00742 EU/mL |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed to support USP <85>, EP 2.6.14, and ISO 11737-1 workflows |
| Sample Format | Aqueous liquid samples only |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Interface | USB-C & Bluetooth 5.0 |
| Software Platform | MIPS EndoTrack™ v3.2 (Windows/macOS compatible) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Pesticide Detection System |
| Instrument Type | Multi-Ion Analyzer |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microsensor Chips |
| Sample Matrix | Aqueous Solutions |
| Configurations | Single-, Dual-, or Multi-Channel Options Available |
| Integrated Components | Micro-peristaltic Pumps, Multi-Functional Microfluidic Analysis Chamber, Embedded Signal Processing Unit |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP523-01 |
| Instrument Type | Benchtop |
| Measurement Range | pH: −2.000–19.999 |
| Ion Concentration | 0.00–14.00 pX (equivalent to 0.01 mg/L–1000 mg/L depending on ion valence and selectivity) |
| Temperature | −10–110 °C |
| Detection Limit | 0.01 mg/L (typical for monovalent ions) |
| Response Time | ≤60 s (for ion concentration stabilization) |
| Accuracy | pH: ±0.002 pH |
| Ion | ±0.5% of reading (monovalent), ±1.0% of reading (divalent) |
| Temperature | ±0.4 °C |
| Temperature Compensation | Automatic, 0–100 °C (pH), 0–60 °C (ion) |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture with audit-trail-capable data logging |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M926, M926S |
| Instrument Type | Benchtop Chloride Analyzer |
| Detection Principle | Coulometric Titration (Silver Nitrate Electrolytic Generation) |
| Sample Volume | M926: 500 µL |
| M926S | 20 µL |
| Measurement Range | M926: 10–999 mg/L Cl⁻ (equivalent to 2–165 mg% NaCl) |
| M926S | 10–299 mmol/L Cl⁻ |
| Detection Limit | 10 mg/L Cl⁻ (M926) |
| Response Time | ≤36 s (typical endpoint detection) |
| Accuracy | M926: ±3 mg/L or <1% RSD at 0.1% Cl⁻ |
| M926S | ±2% at 100 mmol/L Cl⁻ |
| Linearity | ≤1% deviation across full range |
| Repeatability (CV, n=20) | <1.5% at mid-range concentration |
| Temperature Control | Integrated ambient-temperature-stabilized cell compartment |
| Compliance | Designed for GLP/GMP environments |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | IM2021-1 |
| Instrument Type | Benchtop |
| Ion Measured | Fluoride (F⁻) |
| pH Range | 0.00–14.00 |
| mV Range | −1999.9 to +1999.9 mV |
| Detection Limit | 0.01 ppm (as F⁻) |
| Response Time | ≤2 s |
| pH Resolution | 0.01 |
| Temperature Operating Range | 5–40 °C |
| Power Supply | AC 220 V, 100 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2111EL |
| Instrument Category | Sodium Ion Analyzer |
| Installation Type | Online |
| Measurement Range | 0.001 ppb – 10 ppm |
| Response Time | ≤2 min to 95% of final value |
| Accuracy | ±5% of reading or ±0.1 ppb (whichever is greater) |
| Operating Temperature | 5–45 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentine Phosphate Online Monitor |
| Instrument Type | Phosphate (Orthophosphate) Analyzer |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 mg/L |
| Repeatability | ±2% of reading or full scale |
| Measurement Cycle | 5 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature Range | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure Range | 0–345 kPa (0–50 psig) |
| Drain Outlet | 3/4" NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully configured) |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentine Sulfide Ion Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric (with DMPD Oxalate Reagent) |
| Range | 0–5 ppm (customizable for higher ranges) |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±2% of reading or full scale |
| Measurement Wavelength | 650 nm |
| Reference Wavelength | 810 nm |
| Cycle Time | 15 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Volume per Analysis | 30 mL |
| Sample Temperature Range | 5–70 °C |
| Max. Suspended Solids | 2% w/v, max. particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Sample Interface | 1/4" compression fitting |
| Effluent Port | 3/4" NPT male, atmospheric vent |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted (hardware included) |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully configured) |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Cu Ion Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric Spectrophotometry (Bathocuproine or Neocuproine Method) |
| Range | 0–10 ppm (Low), 0–20 ppm (High) |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±2% of reading or full scale |
| Cycle Time | 5–15 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, particle size ≤1.27 mm |
| Sample Pressure | 0–50 psig |
| Sample Interface | 1/4" compression fitting |
| Waste Outlet | 3/4" NPT male, atmospheric discharge |
| Analog Output | 4–20 mA, user-configurable |
| Alarm Outputs | Programmable digital relays |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with integrated hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Fluoride Ion Online Monitor |
| Instrument Type | Fluoride Ion Analyzer |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) |
| Range | 0–20 ppm |
| Accuracy | ±5% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±5% of reading or full scale |
| Cycle Time | 2 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4" NPT male, open drain |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Dimensions (W×H×D) | 610 × 640 × 330 mm |
| Weight | ~36 kg (fully assembled) |
| Mounting | Wall-mounted with included hardware |
| Certifications | CE-compliant, designed to meet general requirements for industrial environmental monitoring installations |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Nitrate Online Monitor |
| Instrument Type | Nitrate Ion (NO₃⁻) Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range Options | 0–10 ppm, 0–50 ppm, 0–100 ppm |
| Accuracy | ±5% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±5% of reading or full scale |
| Cycle Time | 2 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Inlet | 1/4″ compression fitting |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, max particle size 1.27 mm (0.05″) |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4″ NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Dimensions (W×H×D) | 610 × 640 × 330 mm |
| Weight | ~36 kg (fully assembled) |
| Mounting | Wall-mounted with included hardware |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Silicon Online Analyzer |
| Instrument Type | Silica (Orthosilicic Acid) Analyzer |
| Measurement Principle | Colorimetric Spectrophotometry (Molybdenum Blue Method) |
| Detection Wavelengths | 810 nm (low-range), 312 nm (high-range) |
| Range Options | 0–100 ppb, 0–500 ppb, 0–1000 ppb, 0–2 ppm, 0–5 ppm, 0–10 ppm |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppb (at lowest range) |
| Repeatability | ±2% of reading or full scale |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, particle size ≤ 1.27 mm |
| Sample Pressure | 0–50 psig |
| Drain Outlet | 3/4" NPT male, atmospheric vent |
| Alarm Outputs | User-programmable digital relays |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with integrated hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully assembled) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Total Manganese Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric Analysis (Formaldehyde Oxime Complexation) |
| Range | Low: 0–25 ppb, High: 0–200 ppb |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppb |
| Repeatability | ±2% of reading or full scale |
| Cycle Time | 10 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Inlet | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Suspended Solids | ≤2% w/w, max particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Effluent Outlet | 3/4" NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable |
| Analog Output | 4–20 mA, programmable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Dimensions (W×H×D) | 387 mm × 406 mm × 210 mm |
| Weight | ~36 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Zinc Ion Online Monitor |
| Pricing | Upon Request |
| Instrument Type | Multi-Ion Analyzer |