Empowering Scientific Discovery

Jiepu Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicrometrix
OriginUSA
ModelSCM-1
Measurement Range−1000 to +1000 mV
Output4–20 mA, ±10 V, 0–10 V
DisplayLED, millivolt resolution
Flow Rate1 L/min (standard), 5 GPM (optional)
Inlet/Outlet1/2″ barb inlet, 3/4″ barb outlet
Response Time1 second
Accuracy±0.1% of full scale
EnclosureNEMA 4X, IP65
Power230 VAC
Probe MaterialsDelrin®, 316 stainless steel, PTFE
Sensor ServiceabilityReplaceable piston, disposable PTFE sleeve, field-swappable electrodes
CommunicationModbus RTU (optional)
Alarm OutputsDual SPDT relays with adjustable setpoints
Zero & Sensitivity AdjustmentFront-panel accessible, continuous analog tuning
Diagnostic IndicationFlashing LED status indicator
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJENSPRIMA
OriginShanghai, China
ModelinnoMag 300-1
Body TypeIntegral or Remote (S/L)
Pipe Size RangeDN10–DN2000
Flow Range0.2–30,000 m³/h
Accuracy±0.5% of reading
Repeatability±0.1% of reading
Minimum Conductivity≥5 µS/cm
Electrode Materials316L SS, Hastelloy C, Tantalum, Titanium, Platinum
Lining MaterialsPTFE (DN10–DN1000), Hard Rubber (DN50–DN2000)
Process TemperaturePTFE: –40 to +150°C
Rubber–10 to +80°C
Ambient Temperature–20 to +70°C
Output Signals4–20 mA (max. 750 Ω), Pulse/Frequency, Alarm Relay
Communication ProtocolsMODBUS RTU (standard), HART (optional)
Power Supply85–260 VAC or 24 VDC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJENSPRIMA
OriginShanghai, China
ModelinnoCon 6500C
Conductivity Range0.00–20.00 / 200.0 / 2000 µS/cm, 0.00–20.00 / 200.0 / 2000 mS/cm
Resistivity Range0.00–20.00 MΩ·cm
TDS Range0.00 ppm–200.0 ppt
Resolution0.01/0.1/1 µS/cm, 0.1/1 mS/cm, 0.01 MΩ·cm, 0.01/0.1/1 ppm, 0.1 ppt
Accuracy±1% FS
Temperature SensorPt1000
Temp. CompensationAutomatic (with ±10.0 °C offset adjustment) or Manual
Operating Temp.−10.0 to +60.0 °C
Humidity10–90% RH (non-condensing)
DisplayBacklit LCD (44×65 mm), yellow backlight
Power Supply90–260 VAC, 50/60 Hz
OutputsTwo isolated 4–20 mA analog outputs (configurable, max. 600 Ω load)
Relay OutputsTwo independent SPST relays (Hi/Lo alarm, hysteresis adjustable
Enclosure RatingIP54
MountingPanel mount (cutout: 92×92 mm)
Dimensions96×96×130 mm
Weight0.45 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJENSPRIMA
OriginShanghai, China
ModelinnoMag300
Nominal Diameter RangeDN10–DN2000
Flow Range0.2–30,000 m³/h
Accuracy±0.5% of reading
Repeatability±0.1% of reading
Minimum Conductivity≥5 µS/cm
Electrode Materials316 Stainless Steel, Hastelloy C, Tantalum, Titanium
Lining MaterialsPTFE (DN10–DN1000), Rubber (DN50–DN2000)
Lining Temperature LimitsPTFE: –40 to +150 °C
Rubber–10 to +80 °C
Ambient Operating Temperature–20 to +70 °C
Output Signals4–20 mA (max. 750 Ω), Pulse, Alarm
Communication ProtocolsMODBUS RTU (standard), HART (optional)
Power Supply85–260 VAC or 24 VDC
Housing MaterialAluminum
Installation TypesIntegral (S-type), Remote (L-type)
Bidirectional Flow MeasurementYes
Pressure LossNegligible (no obstruction)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJENSPRIMA
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelInnoMag 320
PricingAvailable Upon Request
Construction TypeIntegral (S-type) or Remote (L-type)
Nominal Diameter RangeDN10–DN2000
Flow Range0.2–30,000 m³/h
Accuracy±0.5% of reading
Repeatability±0.1% of reading
DisplayBacklit LCD
InstallationFlanged (custom clamp-on option available)
Minimum Conductivity≥10 µS/cm
Electrode Materials316 Stainless Steel, Hastelloy C, Tantalum, Titanium
Lining MaterialsPTFE (DN10–DN1000), Rubber (DN50–DN2000)
Housing MaterialsController – Aluminum
Temperature LimitsPTFE Lining – –40 to +150 °C
Ambient Operating Temperature–20 to +70 °C
Output Signals4–20 mA (max. 750 Ω), Pulse Output, Frequency Output
Communication ProtocolsMODBUS RTU (standard), HART (optional)
Power Supply85–260 VAC or 24 VDC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJENSPRIMA
OriginShanghai, China
ModelinnoCon 6800T
Product TypeOnline Analyzer
Turbidity Range0.0–4.0 / 40.0 / 400.0 / 1000.0 NTU
SS Range0.0–10.0 / 100.0 / 1000.0 / 2000.0 mg/L
Resolution0.1 NTU, 0.1 mg/L
Operating Temperature0–60 °C
Accuracy±2% of full scale
OutputDual 4–20 mA (turbidity & temperature), RS485 Modbus RTU
Enclosure RatingIP65/NEMA 4X
Sensor Protection RatingIP68
Sensor Material316L stainless steel housing, custom optical glass
Sensor DimensionsØ42 mm × 210 mm L, 1" NPT male thread
Max Pressure4 bar
Cable Length10 m standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJENSPRIMA
OriginShanghai, China
ModelinnoCon 6500CL
Instrument TypeOnline Analyzer
Measurement PrincipleAmperometric Electrochemical Sensor
Measured ParametersFree Chlorine, Chlorine Dioxide, Ozone (multi-parameter)
Range0.000–2.000 ppm and 0.00–20.00 ppm
Accuracy±2% F.S.
Resolution0.001 ppm / 0.01 ppm
Detection Limit0.001 ppm
Temperature CompensationAutomatic (Pt1000 sensor, ±10.0 °C offset adjustable) or Manual
Operating Temperature–10.0 to +60.0 °C
Relative Humidity10–90% RH (non-condensing)
DisplayBacklit LCD (44 × 65 mm, yellow backlight)
Power Supply90–260 VAC, 50/60 Hz
Output SignalsTwo isolated 4–20 mA outputs (configurable, max. 600 Ω), RS485 Modbus RTU
Relay OutputsTwo SPDT relays (5 A / 250 VAC, 5 A / 30 VDC), independently configurable Hi/Lo alarm with hysteresis
Enclosure RatingIP54
MountingPanel-mount (DIN 43700, cutout 92 × 92 mm)
Dimensions96 × 96 × 130 mm
Weight0.45 kg
Housing MaterialFlame-retardant plastic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJENSPRIMA
OriginShanghai, China
ModelinnoMag 300
Measurement Range0.2–30,000 m³/h
Accuracy±0.5% of reading
Repeatability±0.1% of reading
Minimum Conductivity≥5 µS/cm
Electrode Materials316 Stainless Steel, Hastelloy C, Tantalum, Titanium
Lining MaterialsPTFE (DN10–DN1000), Rubber (DN50–DN2000)
Temperature LimitsPTFE Lining –40 to +150 °C
Ambient Temperature–20 to +70 °C
Output Signals4–20 mA (max. 750 Ω), Pulse, Alarm
Communication ProtocolsMODBUS RTU (standard), HART (optional)
Power Supply85–260 VAC or 24 VDC
DisplayBacklit LCD
Installation TypesIntegral (S-type), Remote (L-type)
Pressure LossNegligible (no obstruction in flow path)
Bidirectional Flow MeasurementYes
Pipe Size RangeDN10–DN2000