Empowering Scientific Discovery

Julabo Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJULABO
OriginGermany
ModelPRESTO W50
Temperature Range−50 °C to +250 °C
Temperature Stability±0.05 °C to ±0.1 °C
Bath Volume1.5 L
Circulation TypeExternal
Temperature Control ModeRefrigeration & Heating
Heating Power6.0 kW
Refrigeration Power (at −40 °C)0.6 kW
Pump Flow Rate35–76 L/min
Pump Pressure0.48–3.2 bar
Fluid Fill Volume7.5 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelWIND XL 500H
Nitrogen Purity Range95–99.999%
Nitrogen Flow Rate100–2000 N·L/min
Max Direct Output Pressure7.5 bar
Max Boosted Pressure20 bar
Display10-inch color touchscreen
Air inlet pretreatmentmulti-stage filtration + refrigerated dryer
Noise level73 dB(A) ± 2
Enclosure rating (air compressor motor)IP54
Communication interfacesRS232, analog I/O, alarm relay outputs
Safety featureslow-pressure alarm, auto-depressurization at shutdown, compressor overtemperature protection
ComplianceDesigned for GLP/GMP-adjacent environments
meets ISO 8573-1 Class 22:2 for compressed air quality upstream of PSA unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
Compression PrinciplePiston-Type
Flow Rate0–40 L/min
Maximum Pressure0–9.5 bar
Dew Point≤3 °C (standard operation), down to –15 °C with integrated dryer
Particle Filtration≤0.01 µm (0.01 micrometer)
Oil & Water ContentOil-free, <0.1 ppm total hydrocarbons
Tank MaterialStainless Steel (AISI 304)
Noise Level63 dB(A)
Power600 W
Tank Volume40 L
Dimensions (L×W×H)640 × 470 × 720 mm
Weight72 kg
Safety ComplianceSpring-loaded pressure relief valve (activates at >10 bar), thermal cut-off switch, digital pressure controller with adjustable start/stop setpoints
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelFID FLAT NM
Hydrogen Generation PrinciplePEM Electrolysis of Deionized Water
Output Flow Rate100–1350 mL/min
Output Pressure11 bar (160 psig)
Hydrogen Purity99.99996%
Water Reservoir Capacity7 L
Internal Gas Volume<50 mL
Dimensions (W×D×H)690 × 680 × 150 mm
Weight41–45 kg
Power Consumption90–450 W
Operating Environment15–40 °C, 0–80% RH (non-condensing)
CertificationsCE, CSA, FCC
Display128×64-pixel LCD with tactile buttons
Noise Level≤46 dB(A)
Max Load Capacity80 kg
Gas Outlet1/8" Swagelock
Water Resistivity Requirement≥5 MΩ·cm (min. 1 MΩ·cm acceptable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelT300
DisplayTFT LCD
Pipetting/Dosing Volume Options20 mL or 50 mL Duran® borosilicate glass burettes
Tubing MaterialPTFE
Dosing Accuracy±0.15% systematic error, ±0.05% random error (per EN ISO 8655-6)
Flow Rate Control5 adjustable speed levels
Connectivity1× USB-A, 1× USB-B, 2× RS-232-C
Stirring InterfaceCompatible with TM50 magnetic stirrer (M2 kit standard)
Software IntegrationTitriSoft™ for remote operation, method storage, audit trail, and data export (USB drive, print)
Weighing InterfaceOptional integration with analytical balances via RS-232
Power Supply100–240 V AC, 50/60 Hz
Dimensions (w×d×h)135 × 310 × 205 mm (with burette, excluding stirrer)
Weight2.0 kg (without stirrer)
ComplianceEN ISO 8655-6 (volumetric accuracy), CE marked
Wetted MaterialsPTFE, Duran® borosilicate glass, FEP-coated components
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelWHISPER Hybrid
Nitrogen Flow Rate12–120 L/min @ 7 bar
Air Flow Rate (A)22–70 L/min @ 7 bar
Air Flow Rate (B)10–25 L/min @ 4 bar
Input Air Requirement96–694 L/min
Output Purity95–99% N₂
Dew Point≤ −40 °C
Particle FiltrationISO 8573-1:2010 Class 1.2.1
Pressure RangeAdjustable 8.5–10 bar
Membrane Pore Size40 nm
Fiber ID0.3 mm
Operating Temperature15–35 °C
CertificationsCE, FCC, CSA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelWFA-840D / WFA-860D / WFA-840E
Stirring Positions4 / 6 / 4
Speed Range (rpm)10–300 / 10–300 / 0–200
Speed Resolution1 / 1 / 1 rpm
Speed Accuracy±1 / ±1 / — rpm
DisplayLED / LED / Scale + Knob
BacklightYes / Yes / Yes
Timer Range0–99 h or 0–999 min / OFF or 0–99 h or 0–999 min / 0–30 min or Continuous
Power Consumption11 W / 19 W / 6 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelRACK-PG Plus
Purity99.9996% (standard), 99.99996% (optional)
Max Flow100–600 mL/min
Max Pressure11 bar (160 psig)
Pressure Accuracy±0.1 bar (±5%)
Gas Volume in System<50 mL
Water Resistivity Requirement≥1 MΩ·cm (recommended ≥5 MΩ·cm)
Power Consumption65–250 W
Noise Level≤46 dB(A)
Dimensions19″ rack-mount (483 × 500 × 350 mm, H×W×D)
Weight17–19 kg
CertificationsCE, CSA, FCC
Operating Environment15–40 °C, 0–80% RH (non-condensing)
Display128×64-pixel LCD with tactile buttons
Gas Outlet1/8″ Swagelock
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelNEB-40 / NEB-50 / NEB-91
Temperature Range−35 to +90 °C / −40 to +90 °C / −40 to +150 °C
Flow Rate1–20 L/min
Temperature Stability±0.01–±0.05 °C / ±0.05–±0.1 °C / ±0.05–±0.2 °C
Heating Power2.7 / 6 / 18 kW
Cooling Power (at 20 °C)1.2 / 7.5 / 11 kW
Pump Flow Range16–40 / 35–76 / 26–80 L/min
Pump Pressure0.3–1.7 / 0.48–3.2 / 0.5–3.0 bar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJULABO
OriginGermany
ModelNEM / NEM-50 / NEM-92
Temperature Range−20 to +90 °C (NEM-50) / −40 to +150 °C (NEM-92)
Flow Rate9–26 L/min
Temperature Stability±0.05 to ±0.1 °C (NEM-50) / ±0.05 to ±0.2 °C (NEM-92)
Display5.7″ TFT touchscreen, 0.01 °C resolution
Heating Power6 kW (NEM-50) / 12 kW (NEM-92)
Cooling Power @20 °C7.5 kW (NEM-50) / 25 kW (NEM-92)
Pump Flow35–76 L/min (NEM-50) / 26–80 L/min (NEM-92)
Pump Pressure0.48–3.2 bar (NEM-50) / 0.5–3.0 bar (NEM-92)
CompressorSingle-stage water-cooled (NEM-50) / Two-stage water-cooled (NEM-92)
Heat ExchangerNot equipped (NEM-50) / Equipped (NEM-92)
Secondary Circulation PumpNot equipped (NEM-50) / Equipped (NEM-92)
Heat Transfer FluidAntifreeze (Thermal HL60)
Dimensions (W×D×H)53×66.5×126 cm (NEM-50) / 95×127×190 cm (NEM-92)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelSmart
Instrument TypeBenchtop Rotational Viscometer
Viscosity Range1–2,000,000 mPa·s
Temperature Range0–100 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.1 °C
Speed Range0.3–100 rpm
Speed Steps18
Viscosity Accuracy±1% of full scale
Repeatability±2% of full scale
Display Resolution0.01–1 cP
ComplianceASTM D2196, ISO 2555, ISO 3219, USP <911>
Data InterfaceUSB-B
Power Supply100–240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelSC3-30F-1912D2-C
ComplianceEN 14470-1:2004, EN 1363-1
Fire Resistance Rating30 min
Internal Volume802 L
Internal Dimensions (W×D×H)968 × 507 × 1635 mm
External Dimensions (W×D×H)1101 × 630 × 1951 mm
Shelf Capacity3 standard / up to 5 shelves
Max. Load per Shelf80 kg
Shelf Thickness30 mm
Self-Closing Mechanism Activation50 °C
Vent Closure Temperature70–100 °C
Weight330 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINFORS
OriginSwitzerland
ModelBioUniv CGQR
Measurement PrincipleOptical Backscattering (521 nm & 940 nm dual-wavelength)
InstallationNon-invasive, external mounting on reactor wall or viewport
OD RangeStandard mode (521 nm): 0.5–50
High-density mode (940 nm)15–300
CompatibilitySingle-wall and double-jacketed glass/metal bioreactors, including INFORS Multifors, Minifors, Techfors, and third-party vessels
Sterilization RequirementNone
Cleaning RequirementNone
Port UsageZero bioreactor port occupancy
Mounting FlexibilityInstallable/removable during operation
Regulatory AlignmentDesigned for GLP/GMP-compliant environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelScienceLine B 2220+
Electrode TypeSingle-Reference Electrode
Body MaterialGlass
Reference SystemAg/AgCl (3 mol/L KCl)
Temperature Range−5 °C to +100 °C
pH Range0–14
Junction TypeDouble-Liquid-Junction
Sensing ElementPlatinum
ConnectionL 1 N Cable
ComplianceASTM D1129, ISO 7888, USP <798>, GLP-ready configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelMINI WHISPER HYBRID
Nitrogen Flow Rate5–12 L/min @ 1–7 bar
Air Flow Output35 L/min (dual-stream: 26 L/min @ 7 bar + 10 L/min @ 4 bar)
Nitrogen Purity≥99%
Dew Point−40 °C (atmospheric)
Particle Filtration≤0.01 µm, compliant with ISO 8573-1:2010 Class 1.2.1
Inlet Air Requirement96–192 L/min at 8.5–10 bar
Pressure Drop≤1.5 bar
Operating Temperature15–35 °C
Dimensions (W×H×D)348 × 735 × 350 mm
Weight8 kg
CertificationCE, IQ/OQ support available
TechnologyHollow-fiber membrane separation (0.3 mm ID, 40 nm selective layer)
Interface1/4" G nitrogen outlet, 1/8" G air outlet
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0