- All
- Favorite
- Popular
- Most rated
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XG-010 |
| Conductivity Range (� | S/cm): K=0.01 cm⁻¹: 0.000–2.000 & 0.00–20.00 μS/cm |
| K=0.10 cm⁻¹ | 0.00–20.00 & 0.0–200.0 μS/cm |
| K=1.00 cm⁻¹ | 0.0–200.0 & 0–2000 μS/cm |
| K=10.0 cm⁻¹ | 0–2000 & 0–20000 μS/cm |
| Temperature Range | 5–60 °C |
| Basic Accuracy | ±2.5% F.S. |
| Resolution | 0.001 μS/cm |
| Dimensions | 145 mm × 120 mm × 145 mm (L×D×H) |
| Weight | 0.63 kg |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XG310 |
| Price | USD 2,450 (FOB) |
| Measured Parameter | Total Phosphorus |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Spectrophotometry (Ammonium Molybdate Method) |
| Measurement Range | 0–20 mg/L |
| Accuracy | ≤ ±2% |
| Detection Limit | 0.02 mg/L |
| Resolution | 0.001 mg/L |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XG09 |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Temperature Compensation Range | 0.0–60.0 °C |
| Dimensions | 145 mm × 120 mm × 145 mm (L×D×H) |
| Weight | 0.63 kg |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Input Impedance | ≥10¹² Ω |
| Temperature Sensor | Pt1000 |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable, load <750 Ω) |
| Relay Outputs | 2 SPST (AC220 V/3 A or DC30 V/3 A) |
| Protection Rating | IP65 |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Data Retention Time | >10 years after power loss |
| Operating Ambient | 5–45 °C, ≤85% RH (non-condensing) |
| Storage Temperature | −25–55 °C (electrode storage >0 °C) |
| Sample Temp. Range | 5–60 °C |
| Brand | KC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XG03 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.0–100.0 µg/L |
| Accuracy | ±2% F.S. |
| Detection Limit | 0.01 µg/L |
| Measurement Time | <4 min |
| Batch Capacity | 6 channels |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KS-9A |
| Price | USD 1,150 (FOB) |
| Temperature Range | 79 °C to 400 °C |
| Ignition Source | High-Stability Silicon Nitride Igniter |
| Repeatability | ≤4 °C |
| Applicable Standards | GB/T 3536, ASTM D92 |
| Accuracy | ±2 °C |
| Reproducibility | ≤8 °C |
| Heating Rate | Compliant with GB/T 3536 |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤550 W |
| Dimensions (W×D×H) | 410 × 320 × 165 mm |
| Net Weight | 14.5 kg |
| Brand | Kechuang Starlight (KC) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.0–100.0 µg/L |
| Accuracy | ±2% F.S. |
| Detection Limit | 0.01 µg/L |
| Measurement Time | <4 minutes per cycle |
| Channel Capacity | 1–6 configurable channels |
| Display | 7.0-inch Windows-based HMI touchscreen |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature Range | 5–50 °C |
| Ambient Operating Temperature | 5–45 °C |
| Ambient Humidity | ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤100 W |
| Dimensions (L×D×H) | 460 × 285 × 720 mm |
| Weight | 23 kg |
| Output Signals | 4–20 mA, 0–20 mA, or 0–10 mA (configurable) |
| Data Storage | Non-volatile memory with >10-year retention after power loss |
Show next