Laboratory Low-temperature Storage
Filter
Showing 31–60 of 132 results
| Brand | AUCMA |
|---|---|
| Model | XC-310 |
| Temperature Range | 4 ± 1 °C |
| Effective Volume | 310 L |
| Internal Dimensions (W×D×H) | 565 × 454 × 1198 mm |
| External Dimensions (W×D×H) | 660 × 644 × 1960 mm |
| Power Supply | 220 V AC, 50 Hz |
| Sensor Configuration | 6 high-precision NTC sensors (including dual simulated-blood core temperature probes) |
| Alarm Types | Audible buzzer, visual LED flash, remote alarm output |
| Optional | Integrated temperature data logger with print capability |
| Brand | AUCMA |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YBC-5 |
| Pricing | Available Upon Request |
| Storage Capacity | 5.4 L |
| Temperature Range | 0–10 °C (maintained passively) |
| Ambient Operating Range | 25–43 °C |
| Hold Time | ≥35 days |
| External Dimensions | Φ528 × 747 mm |
| Internal Components | 8 ice packs + 5 tall + 6 short vaccine vial holders |
| Net Weight | 26.5 kg |
| Brand | AUCMA |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YC-50 to YC-1006 |
| Temperature Range | 2–8°C (adjustable, ±0.5°C stability) |
| Power Supply | 220 V / 50 Hz |
| Capacity | 50–1006 L |
| Compressor Type | High-efficiency sealed rotary compressor |
| Refrigerant | R134a (CFC-free) |
| Insulation | Polyurethane foam (CFC-free, 60–100 mm thickness) |
| Display | Dual digital LED (refrigeration zone only) |
| Alarm System | Audible buzzer + visual LED flash for high/low temperature, door open, sensor fault |
| Safety Features | Compressor delay start, cycle protection, redundant thermostat monitoring |
| Compliance | Meets ISO 13485 design principles, supports GLP/GMP documentation workflows |
| Brand | AUCMA |
|---|---|
| Origin | Shandong, China |
| Model | YC-200 |
| Refrigeration Temperature Range | 2–8 °C |
| Effective Capacity | 200 L |
| Internal Dimensions (W×D×H) | 490 × 400 × 1016 mm |
| External Dimensions (W×D×H) | 560 × 578 × 1522 mm |
| Voltage/Frequency | ~220 V / 50 Hz |
| Net Weight | 54 kg |
| Gross Weight | 61 kg |
| Control Accuracy | ±0.1 °C |
| Cooling System | Forced-air convection with high-efficiency compressor and EBM fan motor |
| Safety Alarms | High/low temperature, door open, power failure, sensor fault |
| Door Type | Single transparent double-glazed coated glass door with anti-condensation heating strip |
| Shelving | 3 adjustable wire shelves + optional baskets |
| Compliance | Designed for GLP-compliant storage per ISO 13485 and WHO Technical Report Series No. 961 (2011), Annex 9 |
| Brand | AUCMA |
|---|---|
| Origin | Shanghai, China |
| Model | YC-80 |
| Capacity | 80 L |
| Temperature Range | 2–8°C |
| Internal Dimensions | 360 × 400 × 680 mm |
| External Dimensions | 472 × 500 × 870 mm |
| Power Consumption | 150 W |
| Rated Voltage/Frequency | 220 V / 50 Hz |
| Net Weight | 30.5 kg |
| Gross Weight | 34 kg |
| Shelving | 3 adjustable wire shelves |
| Compressor & Fan | International brand compressor + EBM high-efficiency DC fan motor |
| Temperature Display Resolution | 0.1°C |
| Alarm System | Dual-mode (audible + visual), remote alarm output, battery-backed temperature logging during power outage |
| Brand | AUCMA |
|---|---|
| Model | YCD-265 |
| Temperature Range (Refrigeration Compartment) | 2–8 °C |
| Temperature Range (Freezing Compartment) | –15 to –26 °C |
| Net Capacity | 265 L |
| Internal Dimensions (W×D×H) | 460×480×720 mm (refrigeration section) |
| External Dimensions (W×D×H) | 575×641×1687 mm |
| Power Supply | 220 V / 50 Hz |
| Control System | Microprocessor-based dual-zone digital display |
| Cooling Method | Forced-air (refrigeration), static cooling (freezing) |
| Door Lock | Mechanical safety lock |
| Insulation | CFC-free polyurethane foam |
| Refrigerant | R600a (isobutane) |
| Compliance | Designed per GB/T 20154–2014 (Chinese national standard for medical refrigerators), suitable for GLP-aligned storage environments |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A220 |
| Pricing | Upon Request |
| Brand | Azenta |
|---|---|
| Origin | USA |
| Model | B3C 1500 |
| Temperature Range | -190°C (vapor-phase liquid nitrogen) |
| Static LN₂ Consumption | ~9.5–12.5 L/day |
| Thermal Hold Time (Power Loss) | ~21 days |
| Operation Mode | Fully Automated with Manual Override Capability |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows, supports 21 CFR Part 11–compliant audit trails via integrated software |
| Footprint Options | Configurable modular layouts (standard, double-height, quad-height, and ultra-capacity variants available) |
| Brand | Azenta |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | BioArc™ Ultra High-Density |
| Application Field | Biopharmaceuticals |
| Refrigeration Technology | Open-cycle air-based cooling (GWP = 0, ODP = 0) |
| Max Sample Capacity | 16 million vials |
| Energy Reduction vs. Manual Freezers | Up to 75% |
| Footprint Reduction vs. Manual Freezers | Up to 72% |
| Pickup Stations | Up to 10 |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, LIMS-integrated (API, DB, file-based) |
| Brand | Azenta (formerly Brooks Life Sciences) |
|---|---|
| Origin | USA |
| Model | BioStore III Cryo (B3C) |
| Weight | 1067 kg |
| Operating Temperature | -190°C (vapor-phase LN₂) |
| Static LN₂ Consumption | ~9.5–12.5 L/day |
| Sample Retention at >-135°C (Tg) During LN₂ Interruption | ≥21 days |
| Capacity | 63,000 × 2 mL tubes or 123,000 × 1 mL tubes |
| Footprint | 42 in (107 cm) wide |
| Regulatory Classification | Atmospheric-pressure cryogenic storage system (non-pressure vessel) |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows, supports 21 CFR Part 11-compliant audit trails |
| Brand | Azenta |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | Azenta BioStore™ -190°C |
| Application Category | Biopharmaceuticals |
| Compliance | 21 CFR Part 11 Support, GLP/GMP-Ready |
| Capacity | 990 cryoboxes (250 mL format) |
| Hold Time | ≥17–21 days during LN₂ or power interruption |
| Operating Temperature | ≤ –190°C (vapor-phase LN₂) |
| Sample Integrity Assurance | Tg < –135°C hold time ≥20 days |
| Software | BioStore Controller with audit trail, LIMS integration, user-defined access control |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | BioStore™ Cryogenic Storage System (-190°C) |
| Pricing | Available Upon Request |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Cryo Store Pico |
| Application Field | Biopharmaceuticals |
| Dimensions | 108.5 × 144.2 × 241.5 cm (3'6" × 4'8" × 7'11") |
| Cryo Chamber Volume | 802 L |
| Vial Capacity | 8,800 (at standard 2D barcode-labeled cryovials) |
| Storage Environment | Stable vapor-phase LN₂ at –190°C |
| Temperature Stability During Utility Failure | ≥48 hours (LN₂ + power loss) |
| Regulatory Compliance | FDA 21 CFR Part 11–compliant audit trail, LIMS-integrated inventory management, GLP/GMP-ready data integrity architecture |
| Software Platform | AZENTA CryoControl™ v5.x with touchscreen HMI, real-time environmental logging, and sample-level traceability |
| Brand | Azenta |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Origin Category | Imported |
| Model | Azenta SampleStore™ SE |
| Pricing | Upon Request |
| Application Segment | Biopharmaceuticals |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Model | YDS-10-80 |
| Capacity | 10 L |
| Neck Diameter | 80 mm |
| Total Height | 550 mm |
| Outer Diameter | 300 mm |
| Empty Weight | 7.8 kg |
| Full Weight | 15.9 kg |
| Canister Quantity | 6 |
| Canister Diameter | 63 mm |
| Canister Height | 120 mm |
| Cryovial Slots per Rack | 198 (11 racks × 18 vials) |
| Static Evaporation Rate | 0.18 L/day |
| Hold Time in Static Mode | 56 days |
| Vacuum Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YDS-15 |
| Capacity | 15 L |
| Canister Quantity | 6 |
| Canister Diameter | 38 mm |
| Canister Height | 120 mm |
| Straws per Canister | 3 |
| Cryovials per Straw (6 vials/straw) | 54 |
| Static Evaporation Rate | 0.11 L/day |
| Static Hold Time | 134 days |
| Neck Opening Diameter | 50 mm |
| Total Height | 591 mm |
| Outer Diameter | 394 mm |
| Empty Weight | 8.5 kg |
| Full Weight | 20.7 kg |
| Vacuum Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YDS-3 |
| Capacity | 3.15 L |
| Canister Quantity | 6 |
| Canister Diameter | 38 mm |
| Canister Height | 120 mm |
| Cryovial Strips per Canister | 3 |
| Cryovials per Strip (6/vial strip) | 54 |
| Static Evaporation Rate | 0.12 L/day |
| Static Hold Time | 26 days |
| Neck Opening Diameter | 50 mm |
| Total Height | 435 mm |
| Outer Diameter | 224 mm |
| Empty Weight | 3.1 kg |
| Full Weight | 5.7 kg |
| Vacuum Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Model | YDS-6-80 |
| Capacity | 6 L |
| Neck Diameter | 80 mm |
| Total Height | 480 mm |
| Outer Diameter | 300 mm |
| Empty Weight | 5 kg |
| Full Weight | 9.9 kg |
| Bucket Quantity | 6 |
| Bucket Diameter | 63 mm |
| Bucket Height | 120 mm |
| Cryovials per Rack | 198 (6 per strip × 11 strips per bucket) |
| Static Evaporation Rate | 0.18 L/day |
| Hold Time | 33 days |
| Vacuum Warranty | 5 years |
| Structural Material | High-strength aluminum alloy |
| Surface Finish | Electrostatic powder coating |
| Compliance | GB/T 5458–2012 |
| Brand | BENDER |
|---|---|
| Origin | Sichuan, China |
| Model | YDH-25-216F |
| Capacity | 25 L |
| Liquid Nitrogen Adsorption Capacity | 10 L |
| Static Evaporation Rate | 0.89 L/day |
| Holding Time | 11 days |
| Cryovial Capacity | 500 × 25-well boxes or 550 × 100-well boxes |
| Blood Bag Capacity | 250 × 250 mL or 125 × 500 mL |
| Neck Diameter | 216 mm |
| Total Height | 741 mm |
| Outer Diameter | 396 mm |
| Empty Weight | 12.5 kg |
| Full Weight | 31.8 kg |
| Material | High-Strength Anodized Aluminum Alloy |
| Compliance | GB/T 5458–2012 |
| Warranty | 1-year comprehensive, 5-year vacuum integrity |
| Brand | BENDER |
|---|---|
| Origin | Sichuan, China |
| Model | YDH-4-125 |
| Capacity | 4 L |
| Neck Diameter | 125 mm |
| Total Height | 521 mm |
| Outer Diameter | 300 mm |
| Empty Weight | 7 kg |
| Full Weight | 9.6 kg |
| Static Evaporation Rate | 0.45 L/day |
| Holding Time | 4 days |
| Vacuum Insulation Layer Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Sample Compatibility | Cryovials, 25- and 100-compartment cryoboxes, 50 mL blood bags (up to 6 units), standard blood bag racks |
| Standard Accessories | 1 x inner canister (lift bucket), 1 x neck plug, 1 x locking lid |
| Optional Accessories | Temperature alarm module, certified IATA-compliant aviation transport case |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | UF V |
| Temperature Range | -40 °C to -86 °C |
| Insulation | Vacuum Insulation Panels (VIP) + Polyurethane Foam |
| Cooling System | Cascade Compressor |
| Refrigerants | R-404A and R-508B (non-ozone-depleting) |
| Door Configuration | Right- or Left-Hinged with Mechanical Limiter |
| Access Control | RFID-Based (Model-Dependent) |
| Data Logging | USB-Enabled Recorder (Model-Dependent) |
| Cooling Option | Water-Cooled Condenser (Model-Dependent) |
| Door Lock | Motorized Mechanical Lock |
| Interior | Stainless Steel Chamber |
| Interior Shelves | 3 Stainless Steel Pull-Out Trays |
| Compartment Doors | 4 ABS Plastic Doors |
| Alarm System | Battery-Backed Audible/Visual Alarm with Dry Contact Output, Runtime Hour Meter |
| Interfaces | RS-422 Serial Port, 4–20 mA Analog Output, Zero-Voltage Alarm Relay |
| Internal Volume | 477 L (UF V500) / 700 L (UF V700) |
| External Dimensions (W×H×D mm) | 826×1966×938 (UF V500) / 1100×1966×938 (UF V700) |
| Internal Dimensions (W×H×D mm) | 606×1300×605 (UF V500) / 890×1300×605 (UF V700) |
| Net Weight | 247 kg (UF V500) / 288 kg (UF V700) |
| Brand | Boante |
|---|---|
| Model | BAT43-FS / BAT44-FS |
| Tier Count | 4 |
| Column Count | 3 / 4 |
| Dimensions (mm) | 420×140×232 / 560×140×232 |
| Compatible Cryobox Size | 133×133×54 mm (standard 81-well format) |
| Paper Cryobox Capacity per Tier | 12 / 16 |
| Plastic Cryobox Capacity per Tier | 12 / 16 |
| Material | 0.6–1.0 mm Stainless Steel (AISI 304 equivalent) |
| Construction | Precision-stamped panels, resistance spot-welded joints |
| Customization Available | Yes (lead time ~15 working days) |
| Warranty | 12 months against manufacturing defects under normal ULT operation (−80 °C) |
| Brand | Boante |
|---|---|
| Model Series | BAT53-FS, BAT54-FS, BAT55-FS |
| Tier Count | 5 |
| Column Count | 3 / 4 / 5 |
| Dimensions (mm) | 420×140×295 |
| Compatible Cryobox Format | 133×133×54 mm (standard) |
| Paper Cryobox Capacity (81-well) | 15 / 20 / 25 per rack |
| Plastic Cryobox Capacity (100-well) | 15 / 20 / 25 per rack |
| Material | 0.6–1.0 mm stainless steel (AISI 304 equivalent) |
| Construction | Panel-stamped body with precision resistance spot welding |
| Operating Temperature Range | –86 °C to –150 °C |
| Customization Lead Time | ~15 working days |
| Warranty | 12 months against manufacturing defects |
| Brand | Boante |
|---|---|
| Model | BAT64-FS |
| Layers | 6 |
| Columns | 4 |
| Dimensions (L×W×H) | 560 × 140 × 348 mm |
| Compatible Cryobox Size | 133 × 133 × 54 mm |
| Paper Cryobox Capacity (81-well) | 24 per layer |
| Plastic Cryobox Capacity (100-well) | 24 per layer |
| Material | 0.6–1.0 mm Stainless Steel (AISI 304 grade equivalent) |
| Construction | Panel-stamped frame with precision resistance spot welding |
| Drawer Mechanism | Independent slide-out drawers with integrated cryobox retainer lips and access cutouts |
| Label Slot | Dedicated front-facing label holder per drawer |
| Customization | Available for non-standard cryobox dimensions (lead time ~15 working days) |
| Warranty | 12-month limited warranty covering manufacturing defects under normal ULT operation (−80 °C) |
| Brand | AZENTA (formerly Brooks Life Sciences) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Biocision Cryopod™ |
| Price Range | USD $2,500 – $6,200 |
| Brand | Chart MVE |
|---|---|
| Origin | USA |
| Model | 616 |
| Capacity | Up to 39,000 × 1.2/2.0 mL cryovials |
| Operating Mode | Liquid-phase storage (optional vapor-phase conversion with accessory kit) |
| Neck Opening Diameter | Wide-neck design (≥125 mm typical for 616 class) |
| Static Hold Time | ≥180 days (typical, dependent on ambient conditions and fill level) |
| Dimensions (H × D) | Approx. 1,420 × 760 mm |
| Net Weight | ~180 kg (empty) |
| Optional | Backup battery for temperature monitoring system |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Model | CryoPod™ Portable Cryogenic Transport Container |
| Temperature Range | ≤ −150 °C (LN₂ vapor phase) |
| Hold Time | > 3 hours at ≤ −150 °C |
| Sample Capacity | Up to two SBS-format cryoboxes (e.g., 250 mL standard boxes) or equivalent trays |
| Data Logging | Timestamped temperature logging with USB data export |
| Alarms | Visual and audible alerts for temperature excursions |
| Weight | < 10 kg |
| Compatibility | Standalone use or integrated with BioStore™ automated sample management system |
| Regulatory Context | Designed for GLP-compliant sample transport |
| Brand | Applitech |
|---|---|
| Material Options | SUS304 Stainless Steel Shell + Optional AbioSafe™ Polypropylene Cryo-Bag |
| Volumes | 4 L, 5 L, 10 L |
| Temperature Range | -80 °C (validated) |
| Reusability | Stainless steel shells — autoclavable and cleanable |
| Compliance | Designed for cGMP-aligned bioprocessing environments |
| Customization | Configurable shell geometry, port layout, and tubing management modules |
| Validation Support | Full DQ/IQ/OQ documentation available for AS-series bags (e.g., AS4L-PM005) and FPS-series shells (e.g., FPS0005-3A, FPS0010-3A) |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CG-1 |
| Capacity | 46 L (below rotary rack) / 407 L (total) |
| Evaporation Rate | 8 L/day |
| Hold Time | 33 days |
| External Dimensions | 864 mm (Ø) × 1524 mm (H) |
| Net Weight | 295 kg |
| Operating Temperature | ≤ −135 °C (vapor phase) |
| Control System | Auto Protector Plus with 7-level capacitive liquid level sensors, dual temperature monitoring (sample & vapor), RS232 data logging, 3–5 day battery backup |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CryoMizer |
| Capacity Options | CM-1 / CM-2 / CM-3 / CM-4 |
| Operating Modes | Vapor-phase (−135 °C) and Liquid-phase (−196 °C) Storage |
| Standard Configuration | Cryogenic Rack System, Castor-Mounted Base, LN₂ Level Gauge |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |