Laboratory Low-temperature Storage
Filter
Showing 91–120 of 409 results
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | YDS-30 |
| Price | USD 420 (FOB) |
| Capacity | 30 L |
| Neck Diameter | 50 mm |
| Outer Diameter | 445 mm |
| Height | 660 mm |
| Empty Weight | 13 kg |
| Full Weight | 37.2 kg |
| Hold Time | 220 days |
| Cryogenic Insulation | High-Vacuum Multi-Layer Superinsulation (MLI) |
| Shell Material | Anodized Anti-Corrosion Aluminum Alloy |
| Protective Cover | Genuine Leatherette Outer Sleeve |
| Lid Type | Flip-Open with Locking Clamp |
| Customization | Available for neck diameter, internal rack configuration, and non-standard dimensions |
| Brand | Jihepu |
|---|---|
| Origin | Shandong, China |
| Model | DW-GL290 |
| Effective Capacity | 290 L |
| Storage Temperature Range | –10 °C to –65 °C |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 1200 W |
| Climate Class | N |
| Cabinet Type | Upright, Side-Opening Dual-Door Design |
| Refrigeration Method | Direct Cooling |
| Insulation | CFC-Free Polyurethane Foam with Enhanced Thickness |
| Compressor | Hermetic High-Efficiency Compressor (International Brand) |
| Temperature Sensor | Platinum Resistance Thermometer (Pt100) |
| Control System | Microprocessor-Based Digital Temperature Controller |
| Brand | Eppendorf |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CryoCube F101h |
| Effective Internal Volume | 101 L |
| Inner Dimensions (W × D) | 908 × 566 mm |
| External Dimensions (W × D) | 908 × 566 mm |
| Power Supply | 230 V / 50 Hz |
| Rated Power Consumption | 440 W |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Imported |
| Model | CryoCube F440 |
| Configuration | Upright |
| Effective Volume | 440 L |
| Internal Dimensions | Not specified (standardized for 2" cryobox compatibility) |
| External Dimensions | 955 × 898 × 1960 mm (W × D × H) |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 8300 W |
| Temperature Range | −50 °C to −86 °C |
| Refrigeration System | Two-stage cascade with R290/R170 eco-friendly refrigerants |
| Insulation | Polyurethane foam (F440n) or polyurethane + vacuum insulation panels (Vacupor NT, F440h) |
| Door Design | 5-compartment layout with 5 insulated inner doors |
| Wall Thickness | 130 mm |
| Vacuum Release Port | Integrated automatic pressure equalization valve |
| Brand | Eppendorf |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | CryoCube F570 |
| Form Factor | Upright |
| Effective Volume | 570 L |
| Interior Dimensions (mm) | 765 × 575 × 1265 |
| External Dimensions (mm) | 1025 × 852 × 1940 |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 438 W |
| Brand | Eppendorf |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | CryoCube F740 |
| Effective Storage Volume | 740 L |
| Interior Dimensions (W×D×H, mm) | 865 × 621 × 1390 |
| Exterior Dimensions (W×D×H, mm) | 1090 × 980 × 1973 |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 1000 W |
| Noise Level | 41.3 dB(A) |
| Refrigerant | R290/R170 (hydrocarbon blend) |
| Certification | ENERGY STAR® Qualified |
| Brand | Eppendorf |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FC660h |
| Effective Volume | 760 L |
| Internal Dimensions (mm) | 1560 × 625 × 780 |
| External Dimensions (mm) | 2050 × 785 × 1092 |
| Power Supply | 230 V / 50 Hz |
| Rated Power Consumption | 750 W |
| Energy Consumption | 16 kWh/day at –80 °C |
| Cool-down Time | 5.8 h (from ambient to –85 °C) |
| Inner Lid Thickness | 30 mm |
| Door Seal Type | Dual-loop silicone gasket with frost-inhibiting geometry |
| Security | Password-protected temperature and alarm settings |
| Installation | Integrated slide rails for floor-level deployment |
| Noise Level | ≤48 dB(A) |
| Key | Brand: Equitec |
|---|---|
| Origin | Spain |
| Models | EVFS 220, EVFS 535, EVFS 665, EVFS 765 |
| Effective Volume | 765 L (EVFS 765 model) |
| Internal Dimensions (W×D×H) | 930 × 665 × 1200 mm |
| External Dimensions (W×D×H) | 1190 × 996 × 1999 mm |
| Power Supply | 220 V / 50 Hz |
| Rated Compressor Power | 2.25 HP |
| Temperature Range | −86 °C to −40 °C |
| Temperature Uniformity | ±1.5 °C (at −80 °C, steady state) |
| Control Sensor | Pt100 platinum resistance thermometer |
| Temperature Resolution | 0.1 °C |
| Alarm Backup Battery | Ni–Cd, 48 h standard (72 h optional) |
| Brand | ESCO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Esco LBC |
| Pricing | Available Upon Request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Lifesciences Pte Ltd |
| Product Category | Imported |
| Model | UUS-363-A-1-SS |
| Configuration | Vertical |
| Effective Volume | 363 L |
| Internal Dimensions (W×D×H) | 450 × 620 × 1300 mm |
| External Dimensions (W×D×H) | 710 × 885 × 1980 mm |
| Power Supply | 230 V, 50 Hz, 12–13 A |
| Rated Power Input | 12–13 A @ 230 V, 50 Hz |
| Compliance | ANSI/ASHRAE 72-2005, ARI 1200-2006/2008, UL-certified by DNS USA |
| Brand | ESCO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | LF |
| Pricing | Upon Request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Not specified |
| Pricing | Available upon request |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Bio-Memory |
| Temperature Range | −86 °C |
| Insulation | Full-enclosure Vacuum Insulation Panels (VIP) |
| VIP Thermal Conductivity | <0.005 W/(m·K) |
| Wall Thickness | 80 mm |
| Energy Consumption Reduction | 15% |
| Power-Outage Hold Time Increase | 22% |
| Internal Volume Gain vs. Conventional ULT | +20–30% |
| Compliance | RoHS-compliant, ODS-free manufacturing |
| Configuration Options | Upright, Horizontal, Benchtop |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | BM 175 / BM 340 / BM 515 / BM 690 / BM 1000 |
| Instrument Type | Upright |
| Net Capacity | 176 L to 1011 L |
| Inner Dimensions (W×D×H mm) | 452×630×620 to 765×920×1436 |
| External Dimensions (W×D×H mm) | 875×712×1330 to 1200×1004×2000 |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 400 W |
| Noise Level | <55 dBA |
| Refrigerant | CFC-free & HCFC-free blend (R404A/R290 hybrid or equivalent) |
| Temperature Range | –86 °C standard operating setpoint (stable operation from –80 °C to –86 °C) |
| Temperature Uniformity | ±1 °C (at –80 °C, measured per IEC 61000-4-2 and ISO 15502 protocols) |
| Insulation | Six-sided Vacuum Insulation Panel (VIP) core with polyurethane foam secondary layer |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | BMS 175 / 340 / 515 / 690 / 1000 |
| Configuration | Upright |
| Net Volume | 176–1011 L |
| Interior Dimensions (W×D×H mm) | 452×630×620 to 765×920×1436 |
| Exterior Dimensions (W×D×H mm) | 875×712×1330 to 1200×1004×2000 |
| Power Supply | 220 V AC, 50/60 Hz |
| Noise Level | <55 dBA |
| Refrigerant | CFC-free & HCFC-free blend (R508B/R290 hybrid system) |
| Temperature Range | –86 °C stable operation |
| Uniformity | ±1 °C (at –80 °C, measured per IEC 61000-4-2 and ISO 13732-1) |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Darwin |
| Construction | Aerospace-grade Aluminum Alloy |
| Storage Mode | Vapor-phase or Liquid-phase |
| Capacity Options (2 mL Cryovials) | 750, 2000, 3600, 4800, 6000, 3618, 4824 |
| Neck Diameter | Optimized for Rapid Sample Access |
| Static LN₂ Evaporation Rate | <0.8 L/day (typ. for 3600-capacity unit) |
| Vacuum Insulation | Multi-layer reflective foil + high-vacuum interspace (<1×10⁻³ Pa) |
| Optional Accessories | CryoMemo™ Real-time Monitoring System, Active De-gassing Unit |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | GT |
| Pricing | Upon Request |
| LN₂ Capacity | 2–40 L |
| Sample Storage Capacity | 150–7,300 × 0.5 mL Straws |
| Static Hold Time | 25–350 days |
| Brand | Froilabo |
|---|---|
| Model | Origin |
| Construction | Stainless Steel |
| Origin | France |
| Capacity Range | 500–1636 L |
| Sample Storage Capacity | 27,300–90,400 × 1.2/2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Evaporation Rate | Low (Optimized Vacuum Insulation) |
| Optional Accessories | Aluminum Rotating Rack, CryoMemo Monitoring System |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| Intended Use | Long-term cryopreservation of biological specimens |
| Brand | Froilabo |
|---|---|
| Origin | United Kingdom |
| Model | Polaris |
| Capacity Range | 5,200–94,500 × 2 mL Cryovials |
| Construction | Medical-Grade Stainless Steel |
| Cooling Mode | Vapor-Phase Storage |
| LN₂ Evaporation Rate | Optimized Low-Loss Design |
| Control Interface | CryoLog Color Touchscreen Display |
| Security | Three-Tier User Authentication & Audit Trail Logging |
| Compliance | Designed for GLP/GMP-aligned biobanking environments |
| Certification | CE-marked per EU Medical Device Regulation (MDR) Annex I essential requirements |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | TR Series |
| Construction Material | Aerospace-Grade Aluminum Alloy |
| Vessel Type | Static, Non-Pressurized Liquid Nitrogen Dewar |
| Intended Use | Long-Term Biological Sample Storage at –196 °C |
| Regulatory Context | Designed for GLP/GMP-Compliant Environments |
| Compliance | Meets ISO 23775-1:2022 (Cryogenic Vessels — Part 1: Design and Construction) |
| Safety Certification | CE Marked per PED 2014/68/EU (Pressure Equipment Directive) for auxiliary pressure systems (e.g., optional LN₂ transfer pumps) |
| Capacity Range | 10 L to 100 L (nominal static hold time: 12–120 days depending on model and ambient conditions) |
| Evaporation Rate | 0.12–0.85 L/day (model-dependent, measured at 20 °C ambient, 50% fill level) |
| External Dimensions | Ø220–Ø520 mm × H500–H1200 mm |
| Net Weight | 8.5–42 kg (empty, aluminum-only configuration) |
| Neck Tube Diameter | 50–125 mm |
| Accessories Supported | Programmable LN₂ Level Sensors, Auto-Fill Systems, RFID Sample Rack Integration Kits, Temperature Monitoring Probes (–200 °C to +85 °C), Locking Lid Assemblies |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Voyager |
| Capacity Range | 200–786 L |
| Sample Capacity | 10,400–38,400 × 2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Neck Opening | Wide-mouth |
| Evaporation Rate | Optimized Low-loss Design |
| Monitoring System | CryoMemo Integrated Temperature & Level Monitoring |
| Construction | Medical-grade 304/316 Stainless Steel |
| Compliance | Designed to meet ISO 13485 principles for medical device storage environments |
| Intended Use | Long-term cryopreservation of biological specimens in GxP-regulated settings |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | VSHIPPER |
| Construction | Aerospace-grade aluminum alloy |
| Intended Use | Short-to-medium duration biological sample transport (including air freight) |
| Static Hold Time | Up to 10 days (typical, dependent on ambient conditions and fill level) |
| Capacity | 10–30 L liquid nitrogen (model-dependent) |
| Sample Access | Top-loading with porous cryo-absorbent liner for controlled LN₂ release and reduced boil-off during access |
| Compliance | IATA PI 650 compliant for air transport of biological substances |
| Certification | CE-marked per EU Pressure Equipment Directive (PED 2014/68/EU) for non-pressurized cryogenic vessels |
| Brand | Froilabo |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | XT Series |
| Price Range | USD 6,800 – 13,500 |
| Brand | FRYKA |
|---|---|
| Origin | Germany |
| Model Variants | B 35-85, B 35-50 |
| Effective Storage Volume | 35 L |
| Internal Dimensions (W×D×H) | 425 × 300 × 280 mm |
| External Dimensions (W×D×H) | 580 × 765 × 580 mm (B 35-85) |
| Power Supply | 230 V / 50 Hz |
| Brand | FRYKA |
|---|---|
| Origin | Germany |
| Model | B30-20 |
| Temperature Range | –20 °C to +10 °C |
| Control Accuracy | ±1 °C |
| Net Capacity | 30 L |
| Internal Dimensions (W×D×H) | 360 × 350 × 230 mm |
| External Dimensions (W×D×H) | 530 × 700 × 460 mm |
| Weight | 45 kg |
| Ambient Operating Temperature | +12 °C to +30 °C |
| Power Supply | 230 V / 50 Hz |
| Brand | FRYKA |
|---|---|
| Origin | Germany |
| Model Variants | KBT 02-51, KBT 04-51, KBT 08-51 |
| Temperature Range | −50 °C to −30 °C |
| Control Accuracy | ±1 °C |
| Internal Volume | 2 L / 4 L / 8 L |
| Internal Dimensions (mm) | Ø130×170 / Ø170×185 / 150×300×200 |
| External Dimensions (mm) | 270×400×480 / 340×400×500 / 360×490×570 |
| Power Supply | 230 V / 50 Hz |
| Weight | 22 kg / 22 kg / 36 kg |
| Ambient Operating Temperature | +12 °C to +30 °C |
| Cooling System | Sealed, Fan-Cooled |
| Display | LED with Microprocessor Control |
| Alarm System | Audible/Visual Alarm with 72-h Backup Battery |
| Interfaces | Remote Alarm Output, RS485, 100 mV/K Temperature Recorder Port |
| Optional Upgrade | ST100 Supervisory Control System (KBT 08-51 only) |
| Brand | FRYKA |
|---|---|
| Origin | Germany |
| Model | TT 85-90, TT 50-90 |
| Effective Volume | 90 L |
| Internal Dimensions (W×D×H) | 425 × 300 × 280 mm |
| External Dimensions (W×D×H) | 580 × 765 × 580 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | GengYu |
|---|---|
| Origin | Zhejiang, China |
| Model | DLSB-5/80 |
| Bath Volume | 5 L |
| Bath Dimensions (mm) | Ø220 × 180 |
| Coil Inner Diameter (mm) | Ø200 |
| Opening Diameter (mm) | Ø195 |
| Temperature Range | Ambient to −80 °C |
| Minimum No-Load Temperature | −82 °C |
| Optimal Ambient Temperature | 5–25 °C |
| Relative Humidity | 60–80% RH |
| Power Supply | 220 V / 380 V ±10%, 50 Hz |
| Refrigeration Capacity | 1956–180 W (at varying setpoints) |
| Temperature Control Range (Instrument Display) | −150 to 100 °C |
| Temperature Stability | ±0.5 °C |
| Sensor Type | PT100 |
| Circulation Pump Power | 100 W |
| Head | 4–6 m |
| Flow Rate | 20 L/min |
| Max. System Pressure | 2 MPa |
| Compressor | Danfoss hermetic refrigeration compressor |
| Refrigerant | R22 |
| Circulation Loop Material | SUS304 stainless steel |
| Cabinet Finish | Epoxy-coated corrosion-resistant spray paint |
| Unit Dimensions (W×D×H, mm) | 510 × 345 × 650 |
| Net Weight | 63 kg |
| Safety Protections | Leakage protection, overcurrent circuit breaker, overload relay, compressor high-pressure switch, pump thermal protector, compressor timer, self-diagnostic temperature control system |
| Brand | The Great Wall |
|---|---|
| Origin | Shanghai, China |
| Model | DLSB-5/20 |
| Temperature Range | −20 °C |
| Reservoir Capacity | 5 L |
| Pump Flow Rate | Adjustable, up to 20 L/min |
| Refrigeration Type | Mechanical compression (hermetically sealed compressor) |
| Construction | Corrosion-resistant fluid path |
| Control | Microprocessor-based digital temperature controller with LED display |
| Compliance | Designed for GLP-compliant lab environments |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DW-86L626 |
| Quotation | Upon Request |
| Climate Class | N |
| Cooling Method | Direct Cool |
| Defrost Mode | Manual |
| Refrigerant | Eco-friendly Mixed HFC Blend |
| Noise Level | <50 dB(A) |
| Power Consumption | 1200 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Internal Temperature Range | -40 °C to -86 °C |
| Temperature Uniformity | ±6 °C |
| External Dimensions (W×D×H) | 1035 × 900 × 1980 mm |
| Internal Dimensions (W×D×H) | 760 × 630 × 1310 mm |
| Net Capacity | 626 L |
| Net Weight | 301 kg |
| Compressor Type | Hermetic Reciprocating (Dual Unit) |
| Compressor Power | 927 W per unit |
| Door Configuration | 1 Outer Foam-Insulated Door + 4 Independent Inner Foam Doors |
| Insulation | VIP Vacuum Insulation Panels + Zero-ODP Polyurethane Foam |
| Temperature Control | Microprocessor-Based Digital Controller with LED Display |
| Temperature Sensor | Precision Thermistor |
| Shelving | Adjustable, Load Capacity 50 kg per shelf |
| Casters | Equipped with Locking Swivel Casters |
| Monitoring Ports | 1 Access Port for External Probe or Data Logger |
| Alarm System | Comprehensive Audible/Visual Alarms (High Temp, Low Temp, Power Failure, Door Ajar, Filter Clog, Sensor Fault, Ambient Over-Temp, Low Battery, Voltage Fluctuation) |
| Regulatory Compliance | Registered Medical Device (China NMPA) |