Laser Particle Size Analyzer
Filter
Showing 1–30 of 84 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AccuSizer 780/SIS |
| Dispersion Method | Dry & Wet Dispersion |
| Standard Measurement Range | 0.5–400 µm |
| Optional Ranges | 1–400 µm |
| Channel Count | 32–512 |
| Syringe Volumes | 0.5, 1, 10, 25, 50 mL (user-selectable) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Litesizer DIA Series |
| Pricing | Upon Request |
| Dispersion Methods | Wet, Dry, and Free-Fall Dispersion |
| Instrument Type | Laboratory-Based Dynamic Image Analyzer |
| Measurement Range | 0.5 µm to 16,000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–15 seconds per analysis |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | ASA |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Analog Bandwidth | 10–160 MHz (standard), upgradable to 10–200 MHz |
| Max Sampling Rate | 320 MHz (standard), upgradable to 400 MHz |
| Signal Processing Architecture | Quadrature-based Fourier Transform (FT) with Phase Pulse Detection (PPD) and Adaptive Sampling |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-TK |
| Type | Laboratory Laser Diffraction Particle Analyzer |
| Dispersion Method | Dry & Wet |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Laser Source | Diode-Pumped Solid-State (DPSSL) Laser |
| Wavelength | 532 nm |
| Optical Probe Weight | 2.63 kg (TK1), 2.86 kg (TK2) |
| IP Rating | IP66 |
| Calibration | NIST-Traceable, Single-Calibration-for-Life |
| Signal Processor | ASA2 Advanced Signal Analyzer |
| Software Platform | AIMS (Advanced Imaging & Measurement Suite) |
| Optional Accessories | Anti-Fog Window Shroud, Integrated Thermostatic Heating Module for Sub-Zero/Freezing Environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LS 13 320 XR |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 10 nm – 3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | 10 seconds |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | Bettersize2000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.02–2000 µm |
| Repeatability | ≤0.5% (D50 of NIST-traceable standard samples) |
| Single Measurement Time | ≤1 s |
| Optical System | Patented Dual-Lens Optical Configuration |
| Laser Source | High-Power Fiber-Coupled Semiconductor Laser |
| Detector Array | 90-Channel Photodiode Array (Forward & Backward Scattering) |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11–Compliant Audit Trail & Electronic Signature Support |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | Bettersize2000S |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Spray Laser Particle Size Analyzer |
| Measurement Range | 0.1–2000 µm |
| Repeatability | ≤1% (D50 deviation against certified reference materials) |
| Measurement Time | ≤10 s |
| Optical System | Fourier Transform Configuration with Parallel Beam Path |
| Scattering Theory | Mie Scattering (default), Fraunhofer Diffraction (optional) |
| Detector Array | 76-element photodiode array (forward and side scattering) |
| Sample Zone Length Adjustment | 0–700 mm (Standard), 0–1200 mm (Extended/Elevating/Comprehensive configurations) |
| IP Rating | IP65 |
| Laser Source | High-power semiconductor laser |
| Material | Full stainless-steel construction |
| Data Compliance | FDA 21 CFR Part 11 audit trail support |
| Standards Conformance | ISO 13320, GB/T 19077, GB/T 41949 |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Bettersize2600 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.02–2600 µm (wet), 0.1–2600 µm (dry) |
| Repeatability | ≤0.5% (D50 of NIST-traceable standards) |
| Single Measurement Time | ≤1 s |
| Optical System | Patented Forward-Reverse Fourier Hybrid Optical Path |
| Detector Channels | 92 (covering forward, side, and backward scattering angles) |
| Laser Source | High-Power Polarized Fiber Laser |
| Refractive Index Measurement | Integrated Real-Time Sample RI Determination |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11–Compliant Audit Trail & Electronic Signatures |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Bettersize2600E |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–1500 µm |
| Repeatability | ≤0.5% |
| Single Measurement Time | <1 s |
| Optical Principle | Mie Scattering (default), Fraunhofer Diffraction (optional) |
| Detector Channels | 90 (forward, side, and backward scattering) |
| Laser Source | High-power polarized fiber laser |
| Optical Design | Inverted Fourier optical system with tilted sample cell (patented) |
| Refractive Index Measurement | Yes (patented) |
| Wet Dispersion | Automatic water circulation system with anti-dry-burn ultrasonic disperser (0–50 W, adjustable) |
| Dry Dispersion | Standard auto-feeder (5–20 g) |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Security | FDA 21 CFR Part 11 compliant |
| Regulatory Alignment | Supports GLP/GMP audit trails and SOP-driven workflows |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | Bettersize3000Plus |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | ≤0.5% |
| Measurement Time | ≤10 s |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–1200 µm |
| Repeatability | ≤1% (D50 of certified reference materials) |
| Measurement Time | ≤10 s per analysis |
| Dispersion Method | Wet Dispersion |
| Optical Principle | Mie Scattering Theory (default), Fraunhofer Diffraction (optional) |
| Detector Array | 86-element photodiode array |
| Laser Source | High-power fiber-coupled laser |
| Optical Design | Patented dual-lens optical system with forward-, side-, and back-scatter detection |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11 compliant audit trail and electronic signature support |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | ≤1% (D50 deviation vs. certified reference materials) |
| Measurement Time | ≤10 s per run |
| Dispersion Method | Wet Dispersion |
| Optical Principle | Mie Scattering Theory (default), Fraunhofer Diffraction (optional) |
| Detector Array | 80-channel photodiode array (forward + side scattering) |
| Laser Source | High-power fiber-coupled laser |
| Optical Design | Single-lens Fourier optical system |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11–compliant audit trail and electronic signature support |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | BT-9300ST |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Benchtop Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.05–1500 µm |
| Repeatability | ≤1% (D50, NIST-traceable standard reference materials) |
| Single-Measurement Time | ≤1 s |
| Optical System | Patented Dual-Lens Configuration |
| Laser Source | High-Power Fiber-Coupled Laser (638 nm) |
| Detector Array | 88-Channel Photodiode Array (Forward, Side, and Backward Scattering) |
| Scattering Theory | Mie Scattering (default), Fraunhofer Diffraction (optional) |
| Regulatory Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11 Compliant Audit Trail & Electronic Signature Support |
| Dispersion System | Integrated Auto-Circulating Wet Module with Ultrasonic Probe (0–50 W, adjustable), Auto-Fill, Auto-Drain, Bubble Elimination, and Self-Cleaning Functions |
| Operating Modes | SOP-Driven One-Touch Mode, Manual Mode, Continuous Monitoring Mode |
| Power Supply | 100–240 VAC, 50/60 Hz, 2.5 A |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | In-line Laser Particle Size Analyzer |
| Repeatability | ≤2% (D50, GB Standard Reference Material) |
| Particle Size Range | 0.1–2000 µm |
| Sediment Concentration Range | 0.001–100 kg/m³ |
| Optical Path Adjustment | Auto-adaptive 0.5–40 mm |
| Max Submersion Depth | 800 m (customizable) |
| IP Rating | IP68 |
| Operating Temperature | 0–55 °C |
| Depth Sensor Range | 0–200 m (±0.01 m accuracy) |
| Temperature Sensor Range | −20–85 °C (±0.01 °C accuracy) |
| Laser Source | High-power fiber-coupled polarized laser |
| Detector Array | 80-element forward + side-scatter detector (0.0163°–42° angular coverage) |
| Data Transmission Modes | Wired (real-time), 4G Wireless (real-time), Offline (SD card storage, 16 GB) |
| Battery Standby Time | ≥24 h |
| Compliance | GB/T 15966–2017 |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | Bettersize3000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | ≤0.5% |
| Measurement Time | <10 s |
| Optical Principle | Mie Scattering (default), Fraunhofer Diffraction (optional), Dynamic Imaging |
| Detector Array | 96-element photodetector (forward, side, and backward angles) |
| Refractive Index Measurement | Yes (real & imaginary components) |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982, FDA 21 CFR Part 11 |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACOS |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | In-Line Laser Particle Size Analyzer |
| Measurement Range | Particle Size: 0.6 nm – 3 µm |
| Dynamic Concentration Range | 0.1 ppm – 40% (w/v) |
| Repeatability | Configurable per application protocol |
| Measurement Duration | User-Defined |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BioDLS |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Particle Size Range | 0.5 nm – 3 µm (sample-dependent) |
| Molecular Weight Range | 4 × 10² – 2 × 10⁷ Da (sample-dependent) |
| Concentration Range | 0.1 – 100 mg/mL (sample-dependent) |
| Sample Volume | 2 µL |
| Throughput | Up to 768 samples per run (2 × 384-well plates) |
| Temperature Control | Sample cell: 5–90 °C |
| Storage plate | Ambient to 4 °C |
| Laser Source | 35 mW, 635 nm solid-state laser (optional 30 mW, 850 nm) |
| Scattering Angle | 90° |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 522 physical channels, 10¹⁰ linear channels, dynamic sampling/delay range: 25 ns – 1310 s |
| Interface | USB 2.0 & 1.1 |
| Software | Windows XP/Vista compatible |
| Dimensions (w/d/h) | 300 × 510 × 630 mm (28 kg, no storage cooler) |
| Operating Environment | 10–75 °C, 0–95% RH (non-condensing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FOQELS |
| Pricing | Upon Request |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 173Plus |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Size Analyzer |
| Measurement Range | 0.3 nm – 10 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 15°, 90°, 173° |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ Linear Channels, Dual-Channel Cross-Correlation Support |
| Sample Volume | 0.01–3 mL (with optional 50 µL and 10 µL micro-cells) |
| Molecular Weight Range | 342–2×10⁷ Da |
| pH Range | 1–14 |
| Software Compliance | 21 CFR Part 11 Ready |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 90Plus |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Sample Volume | 10–3000 µL |
| Laser Source | 40 mW Solid-State Laser |
| Detector | PMT or APD |
| Correlator | 4×10¹¹ Linear Channels, 4-Channel Input, Dual Cross-Correlation Support |
| Scattering Angles | 15° and 90° Options |
| Zeta Potential Option | Available |
| Software Compliance | 21 CFR Part 11 Audit Trail Mode |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90plus PALS |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Zeta Potential Measurement Principle | Phase Analysis Light Scattering (PALS) |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Scattering Angles | 15° and 90° |
| Laser Source | 40 mW Solid-State Laser (He-Ne Optional) |
| Detector | APD or PMT |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Sample Volume | 10 µL – 3 mL (with 10 µL & 50 µL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90Plus Zeta |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook Omni |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | <1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 13°, 90°, 173° |
| Zeta Potential Technique | Hardware-Based Phase Analysis Light Scattering (PALS) |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Sample Volume | 10 µL – 3 mL |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Optional Compliance | 21 CFR Part 11 Software Module |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoDLS |
| Dispersion Method | Wet & Dry Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 0.5 nm – 3 µm (refractive index dependent) |
| Repeatability | ≤1% (typical) |
| Measurement Time | <10 s per acquisition (configurable) |
| Sample Volume | 2.5 µL |
| Max Operating Pressure | 400 bar (5,880 psi) |
| Concentration Range | 0.1–100 mg/mL |
| Temperature Control Range | 25–80 °C |
| Laser Source | 35 mW, 638 nm solid-state laser |
| Detector | Avalanche Photodiode (APD) |
| Scattering Angle | 90° |
| Interface | USB 2.0 & 1.1 |
| Data Output | Hydrodynamic diameter distribution (intensity-, number-, and volume-weighted), Gaussian & multimodal fitting, real-time aggregation kinetics plots |
| Operation Mode | Auto-sampling or manual injection |
| Optional Integration | BI-MwA multi-angle static light scattering module for SEC-MALS coupling |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VASCO |
| Price Range | USD 26,000–39,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <5% |
| Measurement Time | 30 seconds |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Winner2000ZDE |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <2 min per run |
| Laser Source | He-Ne, λ = 632.8 nm, output power >2 mW, lifetime >25,000 h |
| Detector Channels | 39 |
| Standards Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Ultrasonic Dispersion | 40 kHz, 35 W, adjustable duration ≥1 s |
| Stirring Speed | 0–3000 rpm (continuously adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL |
| Dimensions | 860 × 360 × 440 mm |
| Weight | 40 kg |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EyeTech |
| Price Range | USD 110,000–138,000 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–3600 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–60 s |
| Concentration Range | ~10⁹ particles/mL |
| Light Source | Stabilized He–Ne Laser (632.8 nm) |
| Laser Resolution | 0.33% of full scale |
| Detector | Silicon PIN Photodiode |
| Stroboscopic Illumination | Adjustable intensity & pulse duration |
| Camera | High-resolution monochrome CCD |
| Shape Parameters | 40 ISO-compliant morphological descriptors |
| Sample Introduction | Liquid suspension, dry powder, microscope slide-mounted |
| Software Compliance | FDA 21 CFR Part 11 (audit trail, user roles, electronic signatures) |
| Brand | Ankersmid |
|---|---|
| Origin | Netherlands |
| Model | EyeTech Laser Particle Size and Shape Analyzer |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Analyzer |
| Measurement Range | 0.1–3600 µm |
| Repeatability | <1% |
| Measurement Time | 30–60 s |
| Principle | Combined Laser Obscuration (LO) and Dynamic Image Analysis (DIA) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Eyetech-Shape DSA-10 |
| Price | Upon Request |
| Measurement Principle | High-Speed Synchronized Stroboscopic Imaging + Digital Image Analysis |
| Particle Size Range | 1 µm – 6 mm |
| Camera Resolution | 640 × 480 px monochrome CCD |
| Strobe Frequency | 1 Hz or 30 Hz (adjustable) |
| Illumination | Software-controlled variable-intensity stroboscopic light source |
| Optical Configuration | Interchangeable dual-magnification lens system (3 objective lenses included) |
| Focus | Motorized focus control |
| Analysis Speed | >10,000 particles per minute (typical), full geometric characterization per frame in <1 s |
| Output Data | Equivalent circular diameter, projected area, perimeter, aspect ratio, convexity, roundness, solidity, elongation, and custom shape factor distributions |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HMD-1 |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Sample Volume | 2 mL |
| Display | Color LCD with backlighted viewing window |
| Power | Rechargeable battery (≥6 h continuous operation) |
| Accuracy | ±0.001 g/cm³ |
| Temperature Control | Peltier-assisted (±0.02 °C stability) |
| Compliance | ISO 12084, ASTM D4052, USP <841> |
