| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ANALYSETTE 22 Micro Tech / Nano Tech |
| Pricing | Upon Request |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 22 Nano Tec |
| Measurement Range | 0.01–2000 µm |
| Laser Sources | Two green lasers (λ = 532 nm, 7 mW each) + one infrared laser (λ = 940 nm, 9 mW) |
| Laser Safety Class | EN 60825-1 compliant, Class 1 |
| Detector Channels | 520 (dual-polarization: vertical & horizontal), including forward and backscattering detection |
| Optical Design | Inverse Fourier configuration with motorized, wide-range sample cell positioning |
| Sample Handling | Modular dry- and wet-dispersion units (optional) |
| SOP Support | Fully configurable, modular Standard Operating Procedures per measurement step |
| Alignment | Automatic beam alignment system |
| Compliance | ISO 13320:2020 (Laser diffraction particle size analysis) |
| Software | FRITSCH ParticleSight™ with customizable reporting, audit trail, background subtraction, automated cleaning cycle, and user-defined dispersion protocols |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fritsch ANALYSETTE 22 NanoTec |
| Pricing | Upon Request |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | TZC-4 Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 1–260 µm |
| Repeatability | <1% |
| Measurement Time | 10 minutes |
| Maximum Capacity | 100 g |
| Readability | 1 mg |
| Particle Analysis Outputs | Sedimentation curve, D50 (median diameter), mean particle size, specific surface area, distribution histogram, error estimation |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HMD-1 |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Sample Volume | 2 mL |
| Display | Color LCD with backlighted viewing window |
| Power | Rechargeable battery (≥6 h continuous operation) |
| Accuracy | ±0.001 g/cm³ |
| Temperature Control | Peltier-assisted (±0.02 °C stability) |
| Compliance | ISO 12084, ASTM D4052, USP <841> |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-300 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–600 µm |
| Repeatability | <1% |
| Measurement Time | 20 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LA-350 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 100 nm – 1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–5000 µm |
| Repeatability | < 0.1% |
| Measurement Time | < 10 s |
| Compliance | ISO 13320 |
| Accuracy | ±0.6% |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5 mm |
| Repeatability | ≤0.06% |
| Measurement Time | <1 min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LA-960 V2 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5000 µm |
| Repeatability | ±0.1% |
| Measurement Time | 10 seconds |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | SZ-100 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 8 µm |
| Repeatability | <2% |
| Measurement Time | 120 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SZ-100 V2 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Characterization System |
| Size Range | 0.3 nm – 10 µm |
| Reproducibility | ±2% |
| Measurement Time | < 2 min |
| Zeta Potential Range | −500 mV to +500 mV |
| Molecular Weight Range | 1,000 – 2×10⁷ Da |
| Detection Angles | 90° and 173° (automatically or manually selectable) |
| Sample Volume | 12 µL – 1,000 µL |
| Measurement Principle for Size | Dynamic Light Scattering (DLS), also known as Photon Correlation Spectroscopy (PCS) |
| Zeta Potential Principle | Laser Doppler Electrophoresis |
| Molecular Weight Determination | Debye Plot Analysis |
| Second Virial Coefficient (A₂) | Yes |
| Integrated Auto-Titrator | Yes (for pH-controlled zeta potential studies) |
| Compliance | NIST-traceable calibration with 100 nm standard particles |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ViewSizer 3000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory NTA System |
| Measurement Range | 10 nm – 15 µm |
| Concentration Range | 5 × 10⁶ – 2 × 10⁸ particles/mL |
| Sample Volume | 350 µL – 1.25 mL |
| Temperature Control Range | 10 °C – 50 °C (±0.1 °C) |
| Dimensions | 55 cm W × 66 cm D × 35 cm H |
| Weight | 27 kg |
| Operating Environment | 15 °C – 30 °C, < 85% RH |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ViewSizer 3000 |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 10 nm – 15 µm |
| Repeatability | Not Specified |
| Measurement Time | 6 min |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-6100-B |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <1% (D50 of standard reference material) |
| Measurement Time | <10 s typical |
| Compliance | ISO 13320:2009, GB/T 19077–2016 |
| Detector Channels | 87-channel high-density crossed array with area compensation |
| Optical Model | Full-range Mie scattering theory with dynamic multiple-scattering correction |
| Laser Source | Sealed fiber-coupled semiconductor laser, λ = 650 nm, P > 10 mW |
| Data Acquisition | 16-bit, 200 kHz sampling rate |
| Feed System | Motorized stepless-speed feeder with software-controlled oil-free silent air compressor (integrated moisture and particulate filtration) |
| Operating Environment | 0–45 °C, 10–85% RH (non-condensing) |
| Power Supply | 110–240 V AC ±20 V, 50–60 Hz |
| Dimensions | 700 × 495 × 300 mm |
| Weight | 35 kg |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB5100-H |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1 µm – 600 µm |
| Repeatability | ≤0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <10 s per run (excluding dispersion conditioning) |
| Compliance | ISO 13320:2020, GB/T 19077–2016 |
| Laser Source | Fiber-coupled semiconductor laser, λ = 635 nm, output power >10 mW |
| Detector Channels | 70-channel high-density photodiode array |
| Optical Alignment | Motorized auto-centering system (0.2 µm step resolution, full alignment in ≤15 s) |
| Ultrasonic Dispersion | Frequency 40 kHz, power adjustable 0–80 W, dry-run protection integrated |
| Circulation System | Flow rate 0–10 L/min, variable speed pump (100–33950 rpm), sample volume ≥120 mL (optional micro-mode: ≥10 mL) |
| Sample Cell | Boiling-type dispersion cell (190–600 mL capacity), quick-release quartz window, dew-point monitoring sensor, bubble-free optical path design |
| Enclosure | Sealed dust- and shock-resistant chassis |
| Optional Configurations | Chemical-resistant wetted parts (acid/alkali/solvent compatible), GLP-compliant audit trail module |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB5500-L |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1 µm – 1000 µm |
| Repeatability | < 0.5% |
| Measurement Time | < 10 s per analysis |
| Compliance | GB, ASTM, ISO, JIS, DIN, CNS |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB6100-A |
| Origin | Shanghai, China |
| Disperser Type | Wet Dispersion System |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <0.5% RSD (D50 of NIST-traceable standard reference materials) |
| Measurement Time | ≤10 s per analysis (optical acquisition only) |
| Detector Channels | 121 |
| Laser Source | Dual-beam, fiber-coupled, λ = 650 nm, P > 10 mW |
| Optical Path Calibration | Fully automated real-time alignment |
| Compliance | ISO 13320:2020, GB/T 19077–2016, ASTM D4294–22 (applicable for colloidal & suspension systems) |
| Sample Handling | Self-cleaning fluidic path with zero residual carryover |
| Environmental Design | Dust- and shock-resistant chassis |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Wet-Dispersion Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <1% RSD (D50) |
| Measurement Time | ≤10 seconds per run |
| Dispersing Medium Volume | ≥180 mL (standard), optional 10 mL micro-circulation mode |
| Ultrasonic Power | 100 W with dry-run protection |
| Optical Alignment | Fully automated mechanical–optical dual-axis centering (≤15 s, 0.2 µm step resolution) |
| Detector Channels | 121 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, USP <429>, FDA 21 CFR Part 11 ready (with audit trail, electronic signature, role-based access control) |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Wet-Dispersion Laser Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <120 s per run |
| Dispersion Method | Wet dispersion with integrated ultrasonication, stirring, and circulation |
| Laser Source | λ = 639 nm, P > 2 mW |
| Ultrasonic Frequency | 40 kHz, Power: 60 W (adjustable duration) |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL (optional 10 mL micro-cell) |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Winner311XPPLUS |
| Price Range | USD 14,000–21,500 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–100 µm |
| Repeatability | >99% |
| Measurement Time | 10–120 s |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Winner 318 |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 4.6–2000 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Optical Principle | Fraunhofer Diffraction |
| Laser Source | LD-pumped solid-state laser, λ = 532 nm, P > 40 mW |
| Detector Channels | 60 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Measurement Zone Length | Adjustable from 1 to 10 m |
| Optical Alignment | 3-axis motorized micrometer stage (±20 mm translation, ±20 mm vertical lift, ±20° rotation) |
| Lens Protection | Dual-air-curtain system |
| Dimensions (L×W×H) | 500 × 254 × 520 mm (main unit) |
| Weight | 45 kg + 23 kg |
| Software | WinPAS v5.x with real-time spatial mapping, multi-scattering correction, and cross-sectional distribution analysis |
| Brand | Jingxin (Chengdu Jingxin Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | ≤10 s per analysis |
| Optical Principle | Full-Range Mie Scattering Theory |
| Detector Channels | 128 |
| Repeatability | ≤1% (D50 deviation against NIST-traceable standard reference materials) |
| Accuracy | ≤1% (D50 deviation) |
| Laser Source | Imported 650 nm semiconductor laser, 30 mW output, >70,000 h lifetime |
| Fourier Lens Diameter | 80 mm |
| Signal Interface | RS232 + USB (up to 100 m transmission distance) |
| Host–Slave Separation Distance | 1–10 m (field-adjustable) |
| Operating System Compatibility | Windows XP / 7 / 10 |
| Environmental Requirements | 5–35 °C, <85% RH |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Brand | Jingxin (Chengdu Jingxin Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-3000 |
| Price Range | USD 21,000–28,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 3000 µm |
| Repeatability | ≤1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–30 s per analysis |
| Measurement Principle | Full-range Mie Scattering Theory |
| Detector Channels | 128 |
| Optical System | Fourier Transform with 80 mm aperture lens |
| Laser Source | Imported semiconductor laser, 650 nm, 30 mW, >70,000 h lifetime |
| Host-Follower Separation Distance | 1–10 m (adjustable) |
| Data Interface | RS-232 and USB (up to 100 m transmission) |
| Software Compatibility | Windows XP / 7 / 10 |
| Environmental Operating Conditions | 5–35 °C, <85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Brand | Jingxin (Chengdu Jingxin Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory Instrument |
| Model | JL-6000 |
| Price Range | USD 17,000–23,000 (FOB Chengdu) |
| Dispersion Method | Dry and Wet Dispersion |
| Instrument Type | Benchtop Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 3000 µm |
| Repeatability | <3% (D50 of NIST-traceable standard reference materials) |
| Measurement Time | ≤120 s (wet mode) |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB6100-B |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Wet) | 0.01 µm – 2000 µm |
| Repeatability | ≤ ±0.5% |
| Measurement Time | 10 s |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB6100-D |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01 µm – 1250 µm |
| Repeatability | <1% |
| Measurement Time | 60 s per test |
| Brand | Jingke Ruida (Kyocera-associated distribution channel) |
|---|---|
| Origin | Beijing, China |
| Model | JK-JG7000 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–780 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference materials) |
| Laser Source | He-Ne laser (632.8 nm, >2 mW) + auxiliary diode laser (650 nm, >2 mW) |
| Detector Channels | 77 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Ultrasonic Dispersion | 40 kHz, 35 W |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL |
| Auto-alignment | Four-phase hybrid stepper motor system |
| Analysis Modes | Free distribution, Rosin-Rammler, log-normal, and sieve-based grading |
| Output Formats | BMP, TXT, DOCX, XLSX |
| Software Interface | English & Chinese (localization-ready) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Dynamic Light Scattering (DLS) Analyzer |
| Measurement Range | 1 nm – 10,000 nm |
| Repeatability | ≤1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 2–5 minutes per sample |
| Dispersion Method | Wet Dispersion |
| Laser Source | Dual solid-state lasers — 30 mW @ 405 nm |
| Detection Geometry | Transmission mode (90°), Reflection mode (160°) |
| Correlator Channels | 4000 |
| Delay Time Range | 50 ns – 100 ms |
| Temperature Control Range | 0.5 °C – 99.5 °C (resolution: 0.002 °C, no thermal gradient) |
| Sample Volume | 2.5 mL (static cell), 500 mL (circulating cell) |
| Ultrasonic Dispersion | 60 W integrated probe |
| Detector | High-gain, low-noise photomultiplier tube (PMT) |
| Gain Settings | 10-step automatic selection |
| Concentration Range | Transmission mode — ppm to 1% w/v |
| Software Compatibility | Windows XP/7/10, bilingual (English/Chinese) UI |
| Data Output | Volume-based & number-based distributions, D10/D50/D90, specific surface area, cumulative & differential histograms (108 size classes) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JL-3000 Split-Design |
| Pricing Range | USD 14,000–21,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | ≤10 s per analysis |
| Measurement Principle | Full-Range Mie Scattering Theory |
| Detector Channels | 128 |
| Repeatability Error | ≤1% (D50 deviation against GB standard reference materials) |
| Accuracy Error | ≤1% (D50 deviation against GB standard reference materials) |
| Optical System | Fourier Transform Lens, 80 mm aperture |
| Laser Source | Imported semiconductor laser, 650 nm, 30 mW, >70,000 h lifetime |
| Alignment System | Built-in CCD auto-centering camera |
| Host-Footprint Distance | Adjustable from 1 m to 10 m |
| Data Interface | RS232 & USB, transmission distance up to 100 m |
| Software Compatibility | Windows XP / 7 / 10 |
| Operating Environment | 5–35 °C, RH <85%, AC 220 V ±10%, 50 Hz ±0.5 Hz |