| Brand | LoHua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | 5B-3B(V11) |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Absorption Photometry (Multi-Wavelength Optical Detection) |
| Wavelength Range | Programmable Multi-Wavelength (e.g., 420 nm, 470 nm, 620 nm, 700 nm) |
| Measurement Range | 0–15,000 mg/L (COD equivalent) |
| Accuracy | ≤ ±5–10% of reading |
| Repeatability | ≤ ±5–10% RSD |
| Detection Limit | 2–15,000 mg/L (method-dependent) |
| Analysis Time | COD < 20 min |
| Batch Capacity | 16 / 25 / 30 samples (user-selectable cuvette rack configuration) |
| Brand | LoHua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry |
| Wavelength Configuration | Multi-Wavelength (610 nm for COD, 420 nm for Ammonia-N) |
| Measurement Range | COD: 0–15,000 mg/L (multi-range auto-segmentation) |
| Ammonia-N | 0–160 mg/L (multi-range auto-segmentation) |
| Accuracy | ≤ ±5% of reading |
| Repeatability | ≤ ±3% RSD |
| Detection Limit | 0.006 mg/L (Ammonia-N) |
| Analysis Time | <20 min (COD), <15 min (Ammonia-N) |
| Batch Capacity | 16 samples per run |
| Data Storage | 12,000 measurement records with timestamp, instrument parameters, and result metadata |
| Calibration | Onboard curve generation via standard solution input and linear/nonlinear regression |
| Connectivity | USB interface + optional infrared wireless module |
| Thermal Control | Adaptive power modulation for 16-position digestion block with over-temperature and time-delay safety cutoff |
| Built-in Thermal Printer | Supports on-demand printout of current/historical results |
| Brand | Lianhua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LH-P3COD |
| Instrument Type | Portable |
| Measurement Principle | Potassium Dichromate Digestion Method (Portable) |
| Wavelengths | 420 nm and 610 nm |
| Measurement Range | 0–15,000 mg/L COD |
| Accuracy | ≤ ±8% for values ≤ 50 mg/L |
| Repeatability | ≤ ±3% |
| Batch Processing Capacity | 6 / 9 / 16 / 25 samples (user-selectable) |
| Brand | Lianhua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LH-T3COD |
| Pricing | Upon Request |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion Method (HJ/T 399–2007) |
| Measurement Range | 20–10000 mg/L (multi-range, segmented) |
| Accuracy | ≤8% |
| Repeatability | ≤3% |
| Brand | Lianhua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | 5B-3C(V8) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion–Spectrophotometric Method (HJ/T 399–2007 compliant) |
| Wavelength | 610 ± 20 nm |
| COD Range | High-range: 20–10,000 mg/L (segmented) |
| Accuracy | ≤ ±8% for COD ≤ 50 mg/L |
| Repeatability | ≤ ±3% |
| Detection Limit | 0.1 mg/L |
| Analysis Time | 20 minutes per batch |
| Sample Throughput | 16 samples per run |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LH-T600 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry |
| Wavelengths | 610 nm / 420 nm |
| COD Range | 0–15,000 mg/L |
| Accuracy | ≤5% |
| Repeatability | ≤±3% |
| LOD | 0.5 mg/L |
| Analysis Time per Batch | 20 min |
| Throughput | 30 samples per run |
| Brand | Lianhua Technology |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LH-CM3H(V11) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry |
| Measurement Range | 0.3–20 mg/L (multi-range segmented) |
| Accuracy | ≤ ±10% |
| Repeatability | ≤ ±5% |
| Limit of Detection (LOD) | 0.08 mg/L |
| Analysis Time per Batch | 50 minutes |
| Sample Throughput | 16 samples per run |