| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | Pangaea Super 8 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 8 samples |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 (FAM, VIC, ROX, CY5) |
| Reaction Volume | 10–50 µL |
| Optical Detection System | Waveguide-CMOS Integrated Optical Module |
| Dimensions (L×W×H) | 280 × 200 × 230 mm |
| Sample Loading | Motorized Auto-Loading Carousel |
| Operating System | Windows 10 (optimized for Microsoft Surface Go) |
| Multi-Unit Networking | ≥4 units via Ethernet (Wi-Fi adapter optional) |
| Connectivity | RJ45 Ethernet port |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Pangaea Super8 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 8 samples |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 (FAM/VIC/ROX/Cy5) |
| Reaction Volume | 10–50 µL |
| Optical System | Waveguide-CMOS Integrated Optical Detection |
| Dimensions | 280 × 200 × 230 mm (L×W×H) |
| Sample Loading | Motorized Auto-Loading Tray |
| Operating System | Windows 10 (optimized for Microsoft Surface Go) |
| Multi-Unit Networking | ≥4 units via Ethernet (Wi-Fi adapter optional) |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Model | Power HC 3000 |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–250 V |
| Current Range | 1–3000 mA |
| Dimensions (L×W×H) | 308 × 242 × 100 mm |
| Safety Features | Overvoltage, Arc, Open-Circuit & Load-Transient Detection |
| Display | LCD showing real-time Voltage, Current, Power, and Timer |
| Brand | Aperbio |
|---|---|
| Model | PowerBasic 300 |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Voltage Range | 5–300 V |
| Current Range | 1–400 mA |
| Dimensions (L×W×H) | 308 × 242 × 100 mm |
| Display | LCD showing real-time voltage, current, power, and timer |
| Programmable Methods | 10 stored protocols, up to 10 steps per method |
| Parallel Outputs | 4 independent output channels |
| Safety Features | Overvoltage, arc detection, open-circuit alarm, short-circuit/overload protection, leakage current protection, auto-recovery after power interruption, pause/resume function |
| Gel Compatibility | Optimized for SDS-PAGE, native PAGE, agarose gel electrophoresis, and isoelectric focusing (IEF) applications |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PowerBasic 600 |
| Instrument Category | Electrophoresis Power Supply |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Voltage Range | 5–600 V |
| Current Range | 1–1200 mA |
| Dimensions (L×W×H) | 308 × 242 × 100 mm |
| Safety Features | Overvoltage, Arc, Open-Circuit & Load-Transient Detection |
| Special Functions | Automatic Transition from Stacking to Separating Gel Mode |
| Brand | Smith |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APEX |
| Price | $1 (Reference Only) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 10–90% RH |
| Altitude Range | −400 to 3000 m |
| Dimensions (H×L×W) | 30.5 × 52 × 44.5 cm |
| Weight | 24 kg |
| Output Power | 7200 W continuous, 24,000 W peak |
| Output Voltage | 0–1200 VDC / 0–240 VRMS AC |
| Frequency Range | 1–1000 Hz |
| Waveforms | DC, Pulsed DC, Burst DC, AC |
| Onboard Data Logging | Peak/Avg Voltage, Current, Power, Waveform Parameters, GPS Coordinates, Timestamp, Internal Temperature, Altitude, Error Codes |
| Display | Sunlight-readable color LCD |
| Safety | Footswitch + Emergency Stop |
| Memory | 12 Predefined Waveform Profiles |
| Environmental Rating | IP54-equivalent enclosure for field use |
| Brand | Aplegen |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5.0 Megapixels |
| Bit Depth | 12-bit |
| Lens | Fixed F1.4 Aperture Lens |
| Excitation Source | 470 nm Blue LED Array |
| Safety Interlock | UV Door-Activated Power Cutoff |
| Integrated Control | Embedded Touchscreen Tablet |
| Compatible Stains | SYBR® Green, MaestroSafe™, GelGreen™, Ethidium Bromide (EtBr), Coomassie Brilliant Blue, Silver Nitrate |
| Brand | Aplegen |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Omega LumC |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 8.4 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Lens Aperture | f/0.95 |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MC-100 |
| Measurement Principle | Dual-wavelength (653 nm & 931 nm) transmittance ratio |
| Display Units | μmol/m² (default), CCI, SPAD |
| Measurement Area | 63.6 mm² (9.0 mm diameter), 19.6 mm² (with optional shade hood for leaves <5 mm wide) |
| Resolution | ±10 μmol/m² (typical plants), 0.1 CCI |
| Linearity | ±1% |
| Repeatability | ±1% |
| Measurement Time | <3 s |
| Data Storage | 8 MB (up to 160,000 measurements |
| Interface | Mini-B USB, RS-232 (GPS-compatible) |
| Display | 50 mm × 15 mm graphical LCD, 8-button navigation |
| Operating Temperature | 0–50 °C |
| Power | 9 V alkaline battery |
| Auto-shutdown | After 4 min of inactivity or no data download |
| Dimensions | 152 × 82 × 25 mm |
| Weight | 210 g |
| Brand | Applied Biosystems |
|---|---|
| Model | 2720 |
| Sample Capacity | 96-well |
| Heating Rate | 2.7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.5 °C |
| Operating Temperature Range | 4.0–99.9 °C |
| Heat Lid Temperature | 105 °C |
| Memory Capacity | 100 protocols |
| Tm Calculation | Built-in |
| Power Failure Recovery | Auto-resume |
| NIST-Traceable Calibration | Yes |
| Diagnostic Self-Test | Integrated |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | 2720 |
| Sample Block | Aluminum 0.2 mL 96-well |
| Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.5 °C (35–100 °C) |
| Dimensions (L×W×H) | 36 × 21 × 22 cm |
| Part Number | 4359659 |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 3500/XL |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Category | Imported |
| Distributor Type | Authorized Third-Party Reseller |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7300 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Reaction Volume | 25–100 µL |
| Detection Channels | 4-color fluorescence detection |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7500 |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 48-well formats |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3100 |
| Instrument Type | First-Generation Capillary Electrophoresis Sequencer |
| Sample Throughput | Up to 768 samples per unattended run (2 × 384-well plates or 4 × 96-well plates) |
| Capillary Array | 16-capillary array |
| Excitation Source | Single 488 nm argon-ion laser |
| Detection | Dual-side illumination with grating-based full-spectrum fluorescence detection using CCD camera |
| Voltage Range | Up to 20 kV |
| Operating Temperature | 18–65 °C |
| Dimensions (W×D×H, door closed) | 74 × 54.8 × 81 cm |
| Weight | 130 kg |
| Power Requirement | 200–240 V AC, 50/60 Hz, ≤15 A, 2000 W |
| Environmental Conditions | 15–35 °C ambient, 20–80% non-condensing humidity |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730 |
| Instrument Type | First-Generation Sanger Sequencer |
| Configuration | Refurbished Unit with Full System Validation |
| Compliance | Designed to meet legacy GLP/GMP-relevant operational standards for nucleic acid analysis |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730XL |
| Category | Imported Instrument |
| Condition | Refurbished Unit |
| Sample Throughput | 96-capillary array |
| Read Length | Up to 1,000 bases (typical under standard POP-7 polymer and BigDye Terminator v3.1 chemistry) |
| Data Output Format | AB1 (.ab1), SCF, FASTA, QUAL |
| Base Calling Accuracy | ≥99.99% (Q40+ for >80% of bases in high-quality templates) |
| Run Time | ~2.5 hours per 96-well plate (standard sequencing protocol) |
| Detection System | CCD-based fluorescence detection with four-color laser excitation (488 nm, 532 nm, 595 nm, 635 nm) |
| Capillary Array | 96 × 50 cm fused-silica capillaries with polymer matrix (POP-7 or POP-6) |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ArcturusXT™ |
| Laser Types | Near-Infrared (NIR) for LCM + Ultraviolet (UV) for Precision Cutting |
| Microscope Platform | Nikon Eclipse® Ti-E Inverted Research Microscope |
| Sample Compatibility | Glass slides, membrane-coated slides (contact/non-contact), petri dishes, standard glass |
| Software | ArcturusXT™ Control Software + Optional AutoScanXT Image Analysis Module |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ATC |
| Sample Capacity | 96-well and 384-well plates |
| Ramp Rate | 3.5°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Uniformity | ≤0.5°C (20 seconds after reaching 95°C) |
| Compliance | SiLA Rapid Integration™ certified |
| Software Interface | RESTful APIs, preconfigured for Beckman Coulter, Hamilton, and other major automation platforms |
| Brand | Applied Biosystems |
|---|---|
| Model | GeneAmp® 9700 |
| Origin | USA |
| Temperature Accuracy | ±0.25°C (35–100°C) |
| Temperature Range | 4–99°C |
| Ramp Rate | 3.5°C/sec (55–95°C) |
| Block Uniformity | ±0.5°C (35–100°C, 30 sec hold) |
| Heat Lid Temperature | 105°C |
| Display Resolution | 0.1°C (computed sample temperature) |
| Dimensions | 40.6 × 30 × 26 cm |
| Weight | 12.7 kg |
| Sample Formats | Interchangeable blocks — 60-well (0.5 mL), 96-well (0.2 mL), dual 96-well, dual 384-well |
| Software | GeneAmp 9700 Network Software (multi-instrument control) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | MiniAmp |
| Instrument Type | Standard PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 30 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniAmp Plus |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.5 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (30 seconds after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex 2×Flat PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 96-well flat plates (0.2 mL) |
| Heating Rate | 1.6°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Inter-well Temperature Uniformity | <0.5°C (20 sec after reaching 95°C) |
| Module Configuration | Dual independent flat-block thermal modules |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 32-well, 96-well, dual 96-well, dual 384-well, and 24 × 20k Digital PCR Chip modules |
| Ramp Rate | Up to 6.0 °C/s (user-adjustable) |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (measured 20 s after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 4°C/sec |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (measured 30 sec after reaching 95°C) |
| Thermal Control Architecture | VeriFlex™ 3-Zone Independent Peltier Module |
| Interface | Capacitive Touchscreen, USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Compatibility | Thermo Fisher Connect Cloud Platform, compatible with standard .pcr file import/export |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | VeritiPro |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well (0.2 mL) and 384-well (0.02 mL) blocks |
| Heating Rate | 6.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.25°C (at 95°C, measured 30 s after target reached) |
| VeriFlex™ Block | 6 independently controlled thermal zones |
| Thermal Lid | 30–110°C, pressure-adjustable, auto-lift |
| Operating Voltage | 100–240 V, 50–60 Hz |
| Power Consumption | ≤700 W |
| Dimensions (H×W×D) | 21.7 × 24.5 × 46.5 cm |
| Weight | 12.0 kg |
| Environmental Requirements | 15–30°C, 15–80% RH (non-condensing) |
| Brand | Getinge |
|---|---|
| Origin | Sweden |
| Model Variants | MiniBio 250, MiniBio 500, MiniBio 1000 |
| Vessel Working Volume | 250 mL, 500 mL, and 1000 mL (respectively) |
| Configuration | Modular, Sterile-Ready Benchtop Bioreactor Platform |
| Control Architecture | Integrated PID-based Process Control with Analog/Digital I/O Expansion Capability |
| Compliance | Designed to Support GLP/GMP-aligned workflows and ASTM E2500-23 risk-based qualification principles |
| [Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AbioBundle Glass Vessel Bioreactor |
| Pricing | Upon Request] |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | AbioPilot |
| Quotation | Upon Request |
| Working Volume Range | 30–270 L |
| Material | 316L Stainless Steel |
| Surface Finish | Electropolished (Ra < 0.4 µm) for Wetted Parts |
| External Finish | Brushed or Mirror-Polished |
| Design Standard | ASME BPE-2023 Compliant |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AbioSUS® Single-Use Bioreactor |
| Volume Options | 50 L, 200 L, 500 L, 1000 L, 2000 L |
| Temperature Control Range | 8–40 °C ±0.1 °C (with chilled water ≤8 °C) |
| Weighing Accuracy | C6-class load cell system |
| Bag Material | 7-layer co-extruded film, USP Class VI & ISO 10993 compliant |
| Stirring System | Dual marine impeller configuration |
| Aeration | Dual bottom gas inlets (0.8 mm coarse sparger + 150 µm microsparger) |
| Control Platform | AbioControl® IDS.S modular controller with 5-tier user permissions and 21 CFR Part 11-compliant audit trail |