| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CNT 80plus |
| Cooling Method | Compressor-based Refrigeration |
| Air Circulation | Forced Convection |
| Temperature Range | −10 °C to +90 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | <1 °C |
| Chamber Volume | 80 L |
| Display | 7-inch Full-Color TFT Touchscreen |
| Control Algorithm | PID + Fuzzy Logic |
| Data Logging Capacity | >10 years of raw temperature data (immutable export via USB flash drive) |
| Audit Trail | Up to 16,000 entries (user actions & alarms, stored internally and exportable via USB, read-only) |
| User Management | 5 configurable user accounts with role-based permissions |
| Multi-point Temperature Calibration | Supported |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Refrigerant | Eco-friendly R134a or equivalent |
| Insulation | Monolithic polyurethane foam injection (≥80 mm thickness) |
| Door Design | Dual-door structure with tempered glass inner door |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | Switchable English/Chinese UI |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 1000 W |
| Ambient Operating Conditions | 5–35 °C, recommended at 25 ±2 °C |
| Safety Features | Auto-restart after power failure, over-temperature alarm, door-open alarm, compressor high-pressure protection, leakage current protection, sensor fault detection |
| Standard Shelving | 2 stainless steel shelves (optional expansion) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | CNT-150 |
| Cooling Method | Compressor-based refrigeration |
| Air Circulation | Forced convection |
| Temperature Range | −10 °C to +85 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤0.8 °C at 40 °C |
| Chamber Volume | 150 L |
| External Dimensions (W×H×D) | 780 × 1200 × 802 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 1000 W |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM, Germany |
| Refrigerant | Eco-friendly R134a or equivalent |
| Temperature Sensor | HERAEUS platinum RTD (Pt100) |
| Insulation | Monolithic polyurethane foam (≥80 mm thickness) |
| Display | 4.3″ color TFT touchscreen |
| Data Logging | ≥3 years of timestamped temperature & alarm logs (U-disk export, write-protected) |
| Audit Trail | ≥16,000 entries (user actions, alarms, parameter changes) |
| User Management | 5 configurable roles with granular access control |
| Communication Ports | USB, RS-232, RS-485 |
| Language Interface | Switchable English/Chinese |
| Safety Features | Over-temperature cut-off, compressor high-pressure protection, door-open alarm, sensor fault detection, leakage current protection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | CNT-150 |
| Temperature Range | −10 °C to 85 °C |
| Temperature Uniformity | ±0.5–1.0 °C (at 15–45 °C) |
| Humidity Control | None |
| Chamber Volume | 150 L |
| Control System | PID + Fuzzy Logic |
| Display | 4.3″ Full-Color Touchscreen LCD |
| Data Logging Capacity | 250,000 entries (1-min interval, immutable export via USB flash drive) |
| Audit Trail | 16,000 immutable operator & alarm logs (USB export) |
| User Management | 5 configurable roles with granular permissions |
| Compressor | SECOP (Danfoss Group), R134a refrigerant |
| Condenser Fan | EBM-Papst (Germany) |
| Temperature Sensor | Heraeus (Germany) |
| Insulation | Monolithic polyurethane foam injection |
| Chamber Viewing | Tempered glass inner door + silicone-sealed 50 mm access port |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | English / Chinese toggle |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Features | Over-temperature alarm, compressor overpressure protection, door-open alert, sensor fault detection, leakage current protection, auto-restart after power interruption |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | CNT150 |
| Temperature Range | −10 °C to 90 °C |
| Temperature Uniformity | ±0.5 °C (at 20–45 °C) |
| Humidity Control | None |
| Chamber Volume | 150 L |
| Control System | PID + Fuzzy Logic |
| Display | 4.3″ Color TFT Touchscreen |
| Data Logging | ≥3 years (immutable, USB export) |
| Audit Trail | 16,000 entries (immutable, USB export) |
| User Management | Up to 5 configurable roles |
| Compressor | SECOP (Danfoss), Germany |
| Condenser Fan | EBM, Germany |
| Refrigerant | Eco-friendly R134a or equivalent |
| Sensor | HERAEUS Platinum RTD (Class A, ±0.1 °C accuracy) |
| Insulation | Monolithic polyurethane foam (≥80 mm thickness) |
| Port | Ø50 mm silicone grommet (right side) |
| Door | Dual-glass structure with tempered inner door |
| Communication | USB, RS-232, RS-485 |
| Language | Switchable English/Chinese UI |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Features | Over-temperature alarm, door-open alert, compressor overpressure protection, leakage current protection, sensor fault detection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | HKC 85 |
| Temperature Range | Ambient +5°C to 70°C |
| Control Method | PID Fuzzy Logic |
| Temperature Uniformity | ±0.5–0.8°C |
| Temperature Fluctuation | ±0.2°C |
| Setpoint Resolution | 0.1°C |
| Chamber Volume | 85 L |
| Interior Dimensions (W×H×D) | 480 × 555 × 320 mm |
| Exterior Dimensions (W×H×D) | 600 × 865 × 570 mm |
| Net Weight | 60 kg |
| Heating Power | 1600 W |
| Interior Material | Thickened SUS304 Stainless Steel |
| Air Circulation | Forced Convection |
| Display | LCD Panel |
| Safety Features | Leakage Protection, Over-Temperature Cut-Off, Door-Open Alarm, Sensor Fault Detection |
| Air Inlet/Outlet | Two Bottom Inlets, One Top Exhaust |
| Shelf Configuration | Two Removable Stainless Steel Shelves |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | HKC-150 |
| Temperature Range | Ambient +5°C to 70°C |
| Control Method | PID Fuzzy Logic (Fixed & Programmable Modes) |
| Uniformity | ±0.5–0.8°C |
| Stability | ±0.2°C |
| Chamber Volume | 150 L |
| Inner Chamber Dimensions (W×H×D) | 550 × 650 × 425 mm |
| Exterior Dimensions (W×H×D) | 670 × 960 × 675 mm |
| Net Weight | 85 kg |
| Heating Power | 2000 W |
| Inner Material | Thickened SUS304 Stainless Steel |
| Insulation | High-Density Polyurethane Foam (≥80 mm) |
| Air Circulation | Forced Convection with Adjustable Fan Speed |
| Display | Backlit LCD Panel |
| Air Inlet/Outlet | Two Bottom Inlets, One Top Exhaust |
| Safety Features | Leakage Protection, Over-Temperature Cut-off, Door-Open Alarm, Sensor Fault Detection |
| Shelf Configuration | Three Removable SUS304 Shelves |
| Leveling | Adjustable Feet with Heavy-Duty Casters |
| Air Exchange | Fresh Air Intake System with Filtered Pathway |
| Compliance | Designed per GB/T 23792–2009 (Chinese National Standard for Laboratory Incubators), Compatible with GLP Environment Requirements |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | HKC-250 |
| Convection Type | Forced Air |
| Control Method | Digital PID Temperature Control |
| Temperature Range | Ambient +5°C to 70°C |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Uniformity | <1.0°C |
| Temperature Fluctuation | ±0.1°C |
| Chamber Volume | 250 L |
| Heating Power | 2500 W |
| Inner Chamber Dimensions (W×H×D) | 700 × 760 × 470 mm |
| Exterior Dimensions (W×H×D) | 820 × 1070 × 720 mm |
| Net Weight | 115 kg |
| Inner Material | Thickened SUS304 Stainless Steel |
| Insulation | High-Density Polyurethane Foam (≥80 mm) |
| Air Inlet/Outlet | Two bottom inlets, one top exhaust |
| Safety Features | Leakage protection, over-temperature cutoff, door-open alarm, sensor fault detection |
| Shelf Configuration | Three removable stainless steel shelves |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | MPC 1000 |
| Refrigeration Temperature Range | 2–8 °C |
| Effective Volume | 1000 L |
| Cooling Method | Inverter-driven Compressor Refrigeration |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.3–0.8 °C |
| Power Supply | AC 220 V, 50/60 Hz |
| Refrigerant | R404a |
| Compressor | SECOP (Danfoss Group) |
| Condenser Fan | EBM (Germany) |
| Insulation | Monolithic Polyurethane Foam |
| Display | 7-inch Color TFT Touchscreen |
| Data Logging | ≥10 years of unalterable temperature/humidity records (USB export) |
| Audit Trail | 16,000+ immutable operation & alarm logs |
| User Management | Up to 5 configurable roles with granular permissions |
| Communication Ports | RS232, RS485, USB |
| Ambient Operating Range | 5–35 °C (recommended: 25 ±2 °C) |
| Internal Dimensions (W×H×D) | 1200×1180×720 mm |
| External Dimensions (W×H×D) | 1390×1840×1120 mm |
| Net Weight | 355 kg |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 1000 |
| Refrigeration System | Inverter-driven SECOP (Danfoss) compressor with R404a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidity control) | −10 °C to 85 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Chamber Volume | 1000 L |
| Control Method | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | Internal non-volatile memory (≥10 years of continuous data), USB export with write-protected binary format |
| Audit Trail | 16,000 entries (user actions, alarms, system events), immutable export via USB |
| User Management | Up to 5 configurable accounts with role-based permissions |
| Sensor System | HERAEUS platinum RTD temperature sensors |
| Insulation | Monolithic polyurethane foam injection (≥120 mm thickness, thermal conductivity ≤0.022 W/m·K) |
| Airflow Design | Dual-side aerodynamic ventilation ports (Ø50 mm) |
| Door Structure | Double-door configuration with tempered inner glass door |
| Communication Interfaces | RS232, RS485, USB-B (for data export and EMS integration) |
| Power Supply | AC 220 V ±10 %, 50/60 Hz |
| Safety Protections | Over-temperature cutoff, refrigerant high-pressure shutdown, leak current protection, low-water alarm, door-open alert, sensor fault detection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 460 |
| Refrigeration | Inverter-driven SECOP (Danfoss) compressor |
| Humidity Reservoir | External water tank |
| Temperature Range (dry) | −10 °C to 85 °C |
| Temperature Uniformity (15–45 °C) | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Chamber Volume | 460 L |
| Insulation | High-density polyurethane integral foaming |
| Cooling Refrigerant | R404a |
| Heating & Humidification Power | 2300 W |
| Compressor Power | 550 W |
| Sensor System | HERAEUS temperature sensor + E+E Electronics capacitive humidity sensor |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | ≥10 years internal storage, USB export (read-only, tamper-proof) |
| Audit Trail | 16,000+ immutable entries (user actions, alarms, system events) |
| User Management | 5 configurable roles with hierarchical permissions |
| Airflow Design | Dual-side aerodynamic 50 mm ports |
| Door Structure | Double-door, inner tempered glass viewing window |
| Communication Interfaces | USB, RS232, RS485 (EMS integration ready) |
| Compliance Support | GLP/GMP-aligned operation logs, 21 CFR Part 11–compatible data integrity architecture |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 760 |
| Refrigeration System | Inverter-driven SECOP (Danfoss) compressor with R404a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidification) | −10 °C to 85 °C |
| Temperature Range (without humidification) | −10 °C to 85 °C |
| Temperature Uniformity (at 25 °C, empty chamber) | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Chamber Volume | 760 L |
| Insulation | High-density polyurethane foam, one-shot foaming process |
| Airflow Design | Dual-side aerodynamic ventilation ports (Ø50 mm) |
| Viewing Window | Tempered glass inner door |
| Control System | 7-inch color TFT touch screen with PID + fuzzy logic algorithm |
| Data Logging | Internal non-volatile memory (≥10 years of continuous 1-min interval logging), USB export (read-only, tamper-proof), audit trail (16,000 entries), user permission management (5 configurable roles) |
| Compliance Support | GLP-compliant data integrity, 21 CFR Part 11-ready audit trail and electronic signature capability (via optional software module), ISO 17025 traceable calibration support |
| Brand | Alison (ALISN) |
|---|---|
| Origin | Shanghai, China |
| Model | TPC-250 |
| Refrigeration System | Inverter-driven Danfoss (SECOP) compressor with R134a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidification) | 10–85 °C |
| Temperature Range (dry operation) | −10–85 °C |
| Temperature Uniformity (15–45 °C) | ±0.2–0.5 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Internal Volume | 250 L |
| Insulation | High-density polyurethane foam, one-shot foaming process |
| Display | 7-inch full-color TFT touch screen |
| Control Algorithm | PID + fuzzy logic hybrid control |
| Data Logging | 3-year capacity (1-min interval), stored internally and exportable via USB (read-only, tamper-proof) |
| Audit Trail | 16,000 entries (user actions, alarms, system events), non-erasable, USB-exportable |
| User Management | Up to 5 configurable accounts with role-based permissions |
| Sensor System | HERAEUS platinum RTD temperature sensors |
| Airflow Design | Dual-side aerodynamic 50-mm diameter ventilation ports |
| Door Structure | Double-door system with inner tempered glass door |
| Communication Interfaces | USB, RS-232, RS-485 (EMS integration ready) |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating & Humidification Power | 2200 W |
| Compressor Power | 250 W |
| Safety Features | Over-temperature alarm, low-water alarm, door-open alarm, sensor fault detection, compressor high-pressure protection, earth-leakage protection, auto-restart after power recovery |
| Brand | Allentown |
|---|---|
| Origin | USA |
| Model | BCU-2 |
| Cage Capacity | 48 (6 × 8) |
| Frame Material | 304 Stainless Steel |
| Cage Material | Polysulfone (PSU) |
| HEPA Class | H14 (Filtration Efficiency ≥99.995% @ 0.1 µm) |
| Operating Pressure | Stable Negative Pressure (Controlled via Feedback Loop) |
| Sterilization | Autoclavable at 134°C |
| Backup Power | ≥10 h (at 50% airflow) |
| Dimensions (W×D×H) | 1466 × 651 × 1995 mm (incl. casters) |
| Weight | 148 kg (empty), 237 kg (fully loaded) |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Discovery™ IVC |
| Regulatory Classification | Imported Medical/Research Equipment |
| Distribution Model | Authorized Distributor |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | EasyCage |
| Cage Base Area (Mouse) | 500 cm² |
| Cage Base Area (Rat) | 903 cm² |
| Feed Capacity (Mouse) | 454 g (HDPE hopper) |
| Feed Capacity (Rat) | 798 g (stainless steel wire mesh lid) |
| Water Options | 300 mL bottle (mouse), dual 300 mL bottles or automatic water (rat) |
| Material | BPA-free, recyclable PET |
| Compatibility | NexGen IVC rack platform |
| Airflow Control | Positive/negative pressure configurable |
| Structural Frame | 304 stainless steel, autoclavable at 134°C |
| Integrated Bedding | NestPak® (100 g pre-filled with ALPHA-dri®, corn cob, or Performance BioFresh™) |
| Ergonomic Features | Snap-fit assembly, visual docking indicators, lightweight design |
| Brand | Allentown |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ferret Isolator System |
| Pricing | Available Upon Request |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | NexGen |
| Construction | 304 Stainless Steel Frame |
| Sterilization Compatibility | Autoclavable at 134°C |
| Cage Material | Polysulfone (High-Transparency, USP Class VI Compliant) |
| System Integration | EcoFlo™ Blower, WiVarium Plus™ Wireless Monitoring, Sentinel™ Health Surveillance, Wi-Com Sensus™ RFID Tracking |
| Compliance | CCAC, AAALAC, NIH Guide, EU Directive 2010/63/EU |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Sentry SPP |
| Construction | 304 Stainless Steel Frame |
| Filtration | Dual Certified HEPA (Supply & Exhaust, Optional) |
| Sterilization | Autoclavable at 134°C |
| Power Backup | ≥10-hour Battery Redundancy |
| Cage Sizes | Mouse (537 cm² floor area), Rat (916 cm² floor area) |
| Sealing System | Patented 4-Point Automatic Seal (US Patent 6,308,660) |
| Docking Interface | SmartDock® Visual Alignment System |
| Compliance | Meets NIH Guide, AAALAC International standards, supports GLP/GMP-aligned animal facility operations |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Measurement Principle | Filter-Based Absorbance Detection |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Linearity | ±1% (0–2.000 Abs), ±2% (2.000–4.000 Abs) |
| Accuracy (405 nm) | ±1% (0–3 Abs), ±2% (3–4 Abs) |
| Precision (CV, 405 nm) | ≤0.2% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Detection Speed | <6 s/96-well (single wavelength), <9 s/96-well (dual wavelength) |
| Optical System | 8-channel high-precision fiber-optic path with automatic well-centering |
| Filter Capacity | 8-position filter wheel (standard filters: 405, 450, 490/492, 630 nm) |
| Display | 7-inch color TFT touchscreen (800 × 480 px) |
| Plate Compatibility | Standard 96-well microplates and strip formats |
| Onboard Storage | 200 protocols + 100,000 assay results (96-well format) |
| Interfaces | 3 × USB (PC, printer, USB drive), Wi-Fi |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Lamp Type | Long-life halogen lamp (≥4000 h) |
| Built-in Diagnostics | Real-time self-check of optical path, mechanical positioning, plate loading, and filter alignment |
| Shaking Function | Adjustable speed and duration |
| Safety Mechanism | Motorized door with obstacle-detection reversal |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100T |
| Detection Principle | Filter-based photometric absorbance |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity (R²) | ≥0.995 (0–3.0 Abs) |
| Wavelength Accuracy | ≤±2 nm |
| Absorbance Precision (CV) | ≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Absorbance Stability | ≤0.005 Abs (0–3 Abs) |
| Absorbance Accuracy | ±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs) |
| Measurement Speed | 6 s/96-well (single wavelength, fast mode) |
| Filter Capacity | 8-position wheel (standard 4 filters: 405, 450, 492, 630 nm) |
| Incubation Function | Yes, 25°C to 50°C (RT + 4°C min) |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Internal memory for 1000 protocols & results + USB export |
| Interfaces | 3× USB (host/device), supports printer, PC, and flash drive |
| Power | AC 100–240 V, 50–60 Hz, 2 A |
| Dimensions (W×D×H) | 295 × 440 × 225 mm |
| Weight | 10 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-Mini |
| Light Source | Dual high-stability LED (340–750 nm) |
| Detection Principle | Absorbance (Optical Density) |
| Standard Filters | 450/630 nm & 405/492 nm |
| Custom Filter Options | 340–750 nm (28 wavelengths available) |
| Detector | 9-photodiode array |
| Measurement Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ≤ ±2 nm |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Photometric Accuracy | ≤ ±(0.5% + 0.01 Abs) [0.0–2.0 Abs), ≤ ±(1.0% + 0.01 Abs) [2.0–3.0 Abs) |
| Precision (CV) | ≤ 0.5% [0–3.0 Abs) |
| Stability | ≤ 0.005 Abs [0.0–2.0 Abs) |
| Read Time | <15 s (single wavelength), <28 s (dual wavelength) for 96-well plate |
| Dimensions (W×D×H) | 135 × 225 × 89 mm |
| Weight | 2.0 kg |
| Power | USB-powered (12 V, 3 A) |
| Interface | 1 × USB-C, 1 × USB-A |
| Connectivity | Bluetooth 5.0, USB cable |
| Software | Cross-platform PC application (Windows 7/10 64-bit), bilingual UI (English/Chinese) |
| Optional Module | AMR-Mini T with integrated incubation (up to 45 °C) and orbital shaking (200–1,200 rpm) |
| Brand | Allsheng |
|---|---|
| Model | AMR-Mini T |
| Detection Principle | Absorbance (Optical Density) |
| Wavelength Range | 340–750 nm |
| Standard Filters | 450/630 nm & 405/492 nm |
| Optional Filters | 340–750 nm (28 discrete wavelengths available) |
| Light Source | Dual high-stability LED |
| Detector | 9-photodiode array |
| Measurement Modes | Endpoint, Kinetic, Dual-Wavelength |
| Absorbance Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Accuracy | ≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Repeatability | CV ≤ 0.5% (0–3.0 Abs) |
| Stability | ≤0.005 Abs (0.0–2.0 Abs) |
| Read Time | <15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well) |
| Incubation Temp Range | RT+4°C to 45°C |
| Dimensions (W×D×H) | 135 × 245 × 91 mm |
| Weight | 2.5 kg |
| Interface | USB-A, USB-C, Bluetooth 5.0 |
| Power | 12 V DC, 3 A |
| Software | Cross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese) |
| Compliance | Designed per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | APW-200 |
| Plate Format | 96-well |
| Residual Volume | ≤1 µL per well |
| Wash Head Options | 8-channel or 12-channel |
| Wash Volume Range | 50–2000 µL (50 µL increments) |
| Wash Cycles | 1–99 |
| Wash Modes | Single-point, dual-point, multi-point |
| Soak & Shake Duration | Up to 99 min 00 sec |
| Number of Wash Solutions | 3 independent channels |
| Fluid Containers | Three 2.5 L wash bottles + one 2.5 L waste bottle |
| Dispense Accuracy | ≤2% @ 300 µL |
| Dispense Precision (CV) | ≤1.5% @ 300 µL |
| Display | 4.3-inch color LCD |
| Onboard Memory | 100 user-programmable protocols |
| Connectivity | USB port for protocol transfer and firmware updates |
| Power Supply | AC 110/240 V, 50/60 Hz |
| Weight | 12 kg |
| Brand | ALLSHENG |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-NGS 180S |
| Sample Throughput | 8–24 samples per run (full automation) |
| Pipetting Channels | 24-channel adjustable (1/8/16/24-channel modes) |
| Pipetting Range | 0.5–200 µL |
| Accuracy (A) | ±10% at 0.5 µL, ±2% at 20 µL, ±1% at 100/200 µL |
| Precision (CV) | ≤5% at 0.5 µL, ≤2% at 20 µL, ≤1% at 100/200 µL |
| Minimum Sample Volume for Fluorometric Quantification | 2 µL |
| dsDNA Detection Limit | 0.4 ng |
| Fluorescence Module | 24-well integrated fluorometer, CV ≤1.5% repeatability |
| Thermal Modules | Dual 4–105 °C refrigeration units (±0.5 °C accuracy/uniformity), one heating module (RT–105 °C), one heating-shaking module (RT–105 °C, 200–3000 RPM, 2 mm orbit), one PCR thermal cycler (block: 4–99 °C, lid: 30–120 °C, uniformity ±0.7 °C, accuracy ≤±0.3 °C) |
| Magnetic Bead Purification | 96-well circular magnetic stand (compatible with PCR/deep-well plates) |
| Tip Capacity | Up to 10 tip boxes (6 single-layer + 2 double-layer positions) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Auto-NGS 200 NGS Library Preparation Workstation |
| Quotation | Available Upon Request |
| Dimensions (W×D×H) | 740 mm × 640 mm × 640 mm |
| Weight | 85 kg |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Sample Throughput | 1–96 samples per run |
| Plate Positions | 26 standard SBS-compliant positions |
| Pipetting System | 24-channel, 1–200 µL (capable of single-channel operation with pressure-capacitive liquid level detection) |
| Minimum Detectable Volume | 20 µL |
| Pipetting Accuracy | ≤±8% at 1 µL |
| Pipetting Precision | ≤±6% at 1 µL |
| Inter-well CV for Purification | ≤5% |
| Lysis/Binding Block Temperature Range | 10–110 °C (active rapid cooling) |
| Elution Block Temperature Range | 37–120 °C |
| Heating Rate (Lysis Block) | 25–110 °C in ≤5 min (from 25 °C ambient) |
| Cooling Rate (Lysis Block) | 110–25 °C in ≤7 min (from 25 °C ambient) |
| Temperature Uniformity | ±1 °C at 95 °C (lysis block) |
| Temperature Accuracy | ±1 °C at 95 °C (lysis block) |
| Integrated Fluorometer | 24-well, real-time concentration quantification |
| Integrated Thermal Module | PCR amplification and hybridization-compatible heating/mixing |
| Mixing Module | Au-Shaker — thermostatic vortex mixer with auto-clamping, 24 V DC, 120 W |
| Cooling Module | Au-Cooler — Peltier-based metal bath, 24 V DC, 160 W, CAN-enabled |
| Onboard Software | Android OS, 10-inch capacitive touchscreen, role-based user accounts, audit-trail-ready protocol editing, USB/LAN connectivity |
| Optional Vision System | For consumables recognition and position validation |
| Contamination Control | Built-in HEPA filtration + UV sterilization |
| Compatible Consumables | SBS-format plates, 8-tube strips, 96-well PCR plates (non-skirted), 60 mL reagent reservoirs, magnetic stands, tip boxes (<700 tips) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 10BS |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput | 1–10 samples/batch |
| Sample Volume Range | 50–5000 µL |
| Processing Time per Batch | 15–30 min |
| Heating Block Temperature Range | Room Temp +5°C to 105°C |
| Lysis/Elution Temperature Range | Room Temp to 120°C |
| Magnetic Bead Recovery Rate | >95% |
| Inter-Well CV | <5% |
| Detection Sensitivity | ≥100 copies |
| Display | 4.3″ Color Touchscreen |
| Internal Storage | SD Card |
| Connectivity | USB, Ethernet, Wi-Fi |
| Power Input | Max 350 W |
| Dimensions (W×D×H) | 340 × 350 × 410 mm |
| Weight | 18.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 48 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–48 |
| Sample Volume Range | 200–3000 µL |
| Processing Time per Batch | 15 min |
| Heating Positions | 2 of 8 plate stations |
| Lysis & Elution Temperature Range | Ambient to 120 °C |
| Inter-Well CV | <5% |
| Detection Sensitivity | >95% positive detection rate for 100-copy samples |
| Display | 7-inch color touchscreen |
| Internal Storage | SD card |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 96 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–96 (also supports 1–24 configuration) |
| Sample Volume Range | 50–1000 µL and 50–10000 µL |
| Processing Time per Batch | 30–60 minutes |
| Heating Capability | 2 of 8 plate positions with precision temperature control (RT to 120 °C) |
| Display | 7-inch color touchscreen interface |
| Onboard Data Storage | Internal SD card |
| Connectivity | USB, Ethernet, optional Wi-Fi |
| UV Sterilization | Integrated |
| Cross-Contamination Control | Anti-drip baffle, disposable consumables, automated magnetic rod sleeve loading/unloading, barcode recognition |
| Reproducibility | CV < 5% across wells |
| Sensitivity | >95% positive detection rate for samples containing ≥100 copies |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure Mini |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–16 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | ~15 minutes |
| Principle | Magnetic Rod-Based Bead Separation with Vertical Mixing |
| Inter-Well CV | ≤3% |
| Magnetic Bead Recovery Rate | >95% |
| Temperature Control Range | Ambient +5°C to 120°C (Lysis & Elution) |
| Mixing Modes | Programmable Vortex, Aspiration/Dispense, Vertical Oscillation |
| Display | 4.3-inch Touchscreen + 3 Physical Shortcut Keys + Optional External Mouse |
| Onboard Program Storage | 100 protocols |
| Connectivity | USB, Ethernet, Wi-Fi |
| Dimensions (W×D×H) | 20 × 26 × 30 cm |
| Weight | 7 kg |
| Power Input | DC 24 V / 5 A (Battery-Compatible) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Auto-Pure S32 |
| Pricing | Upon Request |
| Principle | Magnetic Bead-Based Separation |
| Sample Throughput | 1–32 samples per run |
| Compatible Plate Format | 96-Deep-Well Plate |
| Processing Volume | 30–1000 µL |
| Inter-Well CV | ≤5% |
| Lysis Temperature Range | Ambient to 120°C |
| Elution Temperature Range | Ambient to 120°C |
| Heating Time (RT to 120°C) | ≤4 min |
| Cooling Time (100°C to 40°C) | ≤10 min (at 25°C ambient) |
| Temperature Accuracy | ±0.5°C |
| Temperature Uniformity | ±1°C at 100°C |
| Mixing Intensity | 10 Adjustable Levels |
| Display | 7-inch Color Touchscreen |
| Onboard Program Storage | Up to 500 Protocols |
| Interface Ports | 2× USB-A, 1× USB-B, 1× Ethernet |
| Wireless Connectivity | Built-in Wi-Fi (4G optional) |
| Barcode Scanning | External Scanner Support with Auto-Protocol/ID Recognition |
| UV Sterilization | Integrated Germicidal UV Lamp |
| Air Filtration | HEPA-Grade Aerosol Filtration System |
| Power Supply | AC 110–240 V, 50/60 Hz, 450 VA |
| Dimensions (W×D×H) | 417 × 410 × 426 mm |
| Weight | 20 kg |