Plate Washer
Filter
Showing 1–30 of 32 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 405 LS |
| Soaking Time | 1–600 seconds |
| Wash Cycles | 1–10 |
| Residual Volume | <2 µL per well |
| Plate Shaking | User-definable speed and duration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 405 TS |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Design | Dual-Action Wash Head |
| Fluid Channels | 96-well and 192-channel parallel dispensing/suction |
| Soak Time Range | 0–60 minutes |
| Wash Cycles | 1–250 cycles per protocol |
| Residual Volume per Well | ≤2 µL |
| Plate Shaking | Four Adjustable Intensity Levels (Low, Medium, High, Variable) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | BioTek 406 FX |
| Instrument Type | Multi-Function Plate Washer and Dispenser |
| Sample Format Compatibility | 96-well to 1536-well microplates |
| Dispensing Technology | Non-contact positive displacement (4 syringe pumps) and peristaltic pumping (2 channels) |
| Wash Head | Dual-Action™ with adjustable aspiration/dispense height, X/Y positioning, and angled dispensing nozzles |
| Waste Disposal | Direct drain waste system |
| Automation Interface | Left- and right-side robotic arm access |
| Software Options | LHC Control Software and LHC Secure Software (21 CFR Part 11 compliant) |
| Magnetic Separation Support | Optional magnetic plate adapter |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | 50TS |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configurations | 4-, 8-, 12-, or 16-channel selectable |
| Wash Fluid Ports | 4-, 8-, 12-, or 16-needle manifold |
| Soak Time | User-definable |
| Wash Cycles | 1–10 cycles |
| Orbital Shaking | Programmable intensity (5 levels) and duration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | EL406 |
| Pricing | Upon Request |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | APW-200 |
| Plate Format | 96-well |
| Residual Volume | ≤1 µL per well |
| Wash Head Options | 8-channel or 12-channel |
| Wash Volume Range | 50–2000 µL (50 µL increments) |
| Wash Cycles | 1–99 |
| Wash Modes | Single-point, dual-point, multi-point |
| Soak & Shake Duration | Up to 99 min 00 sec |
| Number of Wash Solutions | 3 independent channels |
| Fluid Containers | Three 2.5 L wash bottles + one 2.5 L waste bottle |
| Dispense Accuracy | ≤2% @ 300 µL |
| Dispense Precision (CV) | ≤1.5% @ 300 µL |
| Display | 4.3-inch color LCD |
| Onboard Memory | 100 user-programmable protocols |
| Connectivity | USB port for protocol transfer and firmware updates |
| Power Supply | AC 110/240 V, 50/60 Hz |
| Weight | 12 kg |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | iWO-960 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 12-channel |
| Rinse Head Design | Integrated Anti-Clogging Mesh Filter |
| Fluid Channels | One wash solution channel + one waste aspiration channel |
| Soak Time Range | 0–10 seconds (adjustable in 1-s increments) |
| Wash Cycles | Manual or programmable auto-mode (1–10 cycles) |
| Residual Volume per Well | ≤1 µL |
| Orbital Shaking Function | Yes, with acoustic-dampened motor and vibration-isolated platform |
| Waste Bottle Capacity | Standard 2 L, with full-level optical sensor and audible/visual alarm |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | Easywash |
| Display | 10-inch capacitive touchscreen (1280 × 800) |
| Wash Head Options | Interchangeable 8-channel or 12-channel single/dual-row heads |
| Aspiration/Dispense Speed | 9 adjustable levels |
| Data Storage | Internal 4 GB flash memory (≥20,000 protocol & run records) |
| Automation Interface | RS-232, USB Device/Host, optional Ethernet |
| Compliance Features | Liquid-level sensing, plate-position detection, leak detection, dual independent peristaltic pumps with pressure monitoring |
| Software | Embedded GUI with bilingual (English/Chinese) support, folder-based protocol organization, USB firmware update & data export capability |
| Residual Volume | ≤2 µL/well (96-well plate, standard wash cycle) |
| Compatibility | ANSI/SLAS-format microplates (96-, 384-well), PCR plates, deep-well plates |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex Pro |
| Instrument Type | Dedicated Microplate Washer |
| Wash Head Configuration | 8-channel |
| Rinse Needle Design | Single-needle per channel |
| Wash Fluid Channels | 8 independent wash fluid channels |
| Waste Aspiration Channels | 8 independent waste aspiration channels |
| Soak Time | Programmable, dynamic control |
| Wash Cycles | Programmable, dynamic control |
| Residual Volume per Well | <4 µL |
| Orbital Shaking Function | Yes |
| Plate Carrier | Integrated magnetic plate carrier for xMAP®-based assays (including MagPlex®) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HT200 |
| Pricing | Upon Request |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FTA-1 |
| Price | Upon Request |
| Vacuum Pressure | −500 mbar |
| Collection Bottle Capacity | 1 L |
| Operating Voltage | 12 V DC |
| Input Power Supply | 12 V DC / 230 V AC adapter included |
| Filter Pore Size | ≤0.027 µm (hydrophobic microbial filter, >99.9% retention efficiency) |
| Tubing Material | Polyethylene |
| Dimensions (W × D × H) | 140 × 180 × 220 mm |
| Weight | 1.8 kg |
| Optional Accessories | MA-8 (8-channel adapter kit), MA-8T (8-channel collection tips), FA-1 (replaceable hydrophobic filter cartridge) |
| Brand | Heales |
|---|---|
| Origin | Shenzhen, China |
| Model | PW-812 |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 8-channel and 12-channel dual-needle design |
| Wash Solution Channels | 3 (2 detergent solutions + 1 deionized water |
| Soaking Time Range | 0–999 seconds/minutes/hours (user-selectable unit) |
| Wash Cycles | 1–999 cycles adjustable |
| Residual Liquid Volume per Well | <0.7 µL |
| Orbital Shaking Function | Medium speed |
| Plate Compatibility | 96-well and 48-well microplates with flat, U-bottom, V-bottom, and round-bottom well geometries |
| Dispense Volume Range | 50–950 µL/well (50 µL increments) |
| extended range | 0–6000 µL/well (25 µL increments) |
| Dispense Precision | CV <1.5% across 96 wells |
| Aspiration Time | 0.1–99.9 s (0.1 s resolution) |
| Rinse Line Flush Duration | 0–240 s |
| Auto-Rinse Interval for DI Water | 0–20 s |
| Wash Head Positioning Modes | 5 preset vertical alignment options (horizontal, left, center, right, bottom-touch) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HT200 |
| Pricing | Available Upon Request |
| Brand | Keebio |
|---|---|
| Model | DKW310 |
| Type | Multifunctional Plate Washer |
| Wash Head Configuration | 8- or 12-channel |
| Wash Fluid Channels | 8 or 12 |
| Soak Time Range | 0–24 h (adjustable) |
| Wash Cycles | 1–99 (adjustable) |
| Residual Volume per Well | ≤1 µL |
| Dispense Volume Range | 50–3000 µL (10-µL increments) |
| Dispense Accuracy | ≤±2.0% |
| Shake Duration | 0–600 s (adjustable) |
| Rinse Time per Channel | 0.1–9.9 s |
| Dimensions (W×D×H) | 446 × 368 × 164 mm |
| Weight | 12 kg |
| Onboard Program Storage | ≥100 user-defined protocols |
| Plate Compatibility | Flat-, U-, and V-bottom microplates |
| Optional Feature | Liquid-level sensor for waste/residual overflow detection |
| Brand | Keebio |
|---|---|
| Model | DKW330 |
| Type | Multifunctional Plate Washer |
| Wash Head Configuration | 8- or 12-channel |
| Number of Wash Solution Channels | 1 (expandable to 3–4) |
| Soak Time Range | 0–24 h |
| Wash Cycles | 1–99 |
| Residual Volume per Well | ≤1 µL |
| Plate Agitation | Yes |
| Dimensions (W×D×H) | 446 × 368 × 164 mm |
| Weight | 12 kg |
| Liquid Dispense Volume | 50–3000 µL (10 µL increments) |
| Dispense Time | 0.1–9.9 s |
| Agitation Duration | 0–600 s |
| Programmable Protocols | >100 user-defined methods |
| Compatible Plate Formats | Flat-, U-, and V-bottom microplates |
| Brand | Kehua Biosciences (KHB) |
|---|---|
| Origin | Shanghai, China |
| Model | ST-36W |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 8-channel or 12-channel |
| Wash Solution & Waste Reservoirs | 2 L each |
| Soaking Time | Programmable |
| Wash Cycles | Adjustable |
| Residual Volume per Well | ≤1 µL |
| Brand | Kehua Biosciences (KHB) |
|---|---|
| Origin | Shanghai, China |
| Model | ST-96WT |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head | 96-pin |
| Rinse Head Configuration | 1–8 adjustable rinse lines |
| Wash Solution Channels | 2 independent wash solution inlets |
| Waste Liquid Channels | 2 dedicated waste outlets |
| Soak Time Range | 0–999 seconds |
| Wash Cycles | 0–100 cycles |
| Residual Liquid Volume | ≤ 0.8 µL per well |
| Orbital Shaking Function | Adjustable speed and duration |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ST-36WT |
| Price | USD 2,250 (FOB Shanghai) |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 1×8 or 1×12 disposable tip manifold |
| Wash Channels | 3 independent fluid paths |
| Soak Time Range | 0–19 min 59 s (adjustable in 1-s increments) |
| Wash Cycles | 0–99 (programmable) |
| Residual Liquid Volume | ≤0.5 µL per well after aspiration |
| Plate Shaking Function | Yes |
| Plate Compatibility | 96-well and 48-well microplates (U-, V-, and flat-bottom formats) |
| Aspiration/Dispense Mechanism | Dual diaphragm pump system |
| Liquid Level Sensing | Integrated optical liquid level detection with real-time alarm output |
| Onboard Memory | ≥100 user-defined wash protocols |
| Fluid Reservoirs | 2 L wash solution bottle, 2 L waste bottle, 2 L rinse/buffer bottle |
| Dispense Volume Range | 0–4200 µL per cycle (incremental step ≤50 µL) |
| Dispense Precision | CV ≤2% (at 300 µL/well, 96-well plate) |
| Aspiration Mode | Standard or sweep mode |
| Plate Positioning | Vertically and horizontally adjustable wash head |
| Power Supply | 200–240 VAC, 50/60 Hz |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Model | ST-96W |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head | 96-pin |
| Rinse Head Configuration | 1–8 independent rinse channels |
| Wash Solution Channels | 2 |
| Waste Liquid Channels | 2 |
| Soak Time Range | 0–999 s |
| Wash Cycles | 1–100 |
| Residual Volume per Well | ≤ 0.8 µL |
| Orbital Shaking Function | Adjustable |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | WD-2103B |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | One 8-pin and one 12-pin removable wash head |
| Wash Head Design | Dual-row needle configuration |
| Wash Fluid Channels | Dual-row needle architecture (standard 1-channel |
| Soaking Time Range | 0–24 hours adjustable |
| Wash Cycles | 0–99 cycles programmable |
| Residual Liquid Volume | ≤1 µL per well (average) |
| Orbital Shaking Function | 3-level intensity (low/medium/high), shaking duration 0–24 h adjustable |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | 318W+ |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel and 12-channel |
| Washing Modes | Strip Wash and Full-Plate Wash |
| Wash Fluid Reservoirs | Three 2-L Bottles (Waste, Deionized Water, Wash Buffer), Each with Liquid-Level Sensors |
| Soaking Time Range | 0–99 min 99 sec (1-sec increments) |
| Wash Cycles | 1–99 |
| Residual Volume per Well | ≤2 µL |
| Orbital Shaking | Adjustable Speed |
| Dispense Volume per Well | 10–300 µL |
| Dispense Accuracy Repeatability | ≤5% |
| Positive Pressure (Dispense Pump) | 200 kPa |
| Negative Pressure (Aspirate Pump) | 60 kPa |
| Fluid Consumption | ~50 mL per full 96-well plate (wash), ~15 mL (pre-wash) |
| Power Input | 150 VA, AC 110–240 V, 50/60 Hz |
| Display | 240 × 128-dot LCD with Touchscreen Interface |
| Aspiration Speed Settings | 6-step adjustable |
| Aspiration Time | 3–99 sec (1-sec increments) |
| Aspiration Modes | Standard, Two-Point Aspiration, Sweep Aspiration |
| Compatible Plate Formats | U-bottom, V-bottom, Flat-bottom microplates |
| Stored Protocols | Up to 99 user-defined methods |
| Programmable Steps | Dispense, Aspirate, Pause, Shake, Loop — freely sequenced |
| Net Weight | 9.6 kg |
| Dimensions (W × D × H) | 300 × 210 × 350 mm |
| Packaging Dimensions | 510 × 450 × 300 mm |
| Brand | Shanda |
|---|---|
| Model | SD-XB |
| Instrument Type | Multi-Function Microplate Washer |
| Wash Head Configuration | 8-channel or 12-channel dual-row removable wash head |
| Wash Fluid Channels | 1 standard (up to 4 optional) |
| Soaking Time Range | 0–24 h (hh:mm:ss adjustable) |
| Wash Cycles | 0–99 |
| Residual Volume per Well | ≤1 µL |
| Plate Compatibility | Standard 96-well flat-bottom, U-bottom, V-bottom, and C-bottom microplates |
| Wash Row Selection | 1–12 rows (including skip-row configuration) |
| Liquid Delivery Pressure | 5 adjustable levels |
| Aspiration/Dispense Time | 0–9 s (extendable) |
| Plate Shaking | 0–24 h (hh:mm:ss), 3 intensity levels |
| Cleaning Modes | Center wash, dual-point wash |
| Program Storage | 200 user-defined protocols + 20 pre-stored plate profiles |
| Liquid Level Monitoring | Waste bottle full-level alarm |
| Display & Interface | 5.6-inch color TFT touchscreen, 7×24 h continuous operation with auto power-saving mode |
| Power Input | AC 100–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 380 × 330 × 222 mm |
| Net Weight | ~9 kg |
| Reagent Bottles | Three 2 L bottles included |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | HydroFlex |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel or dual 8-channel (16-channel equivalent) |
| Wash Fluid Channels | 1, 2, or 4 selectable |
| Soaking Time | Programmable |
| Wash Cycles | 1–10 |
| Residual Volume per Well | ≤1.8 µL |
| Orbital Shaking | Linear, 3 adjustable speeds |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | HYDROFLEX™ |
| Instrument Type | Multifunctional Plate Washer |
| Application Scope | ELISA, Magnetic Bead-Based Assays, Vacuum Filtration, Adherent Cell Washing, Protein Microarray Processing |
| Control Options | Integrated Keypad & PC Software (HydroFlex Control Software) |
| Design Architecture | Modular |
| Liquid Handling Principle | Multi-point Aspiration, Drop-wise Dispensing |
| Vacuum System | Integrated Pressure-Sensing Vacuum Pump |
| Compliance Context | Designed to support GLP-compliant workflows |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | HYDROSPEED™ |
| Instrument Type | Multifunctional Plate Washer |
| Regulatory Compliance | EU IVD Directive 98/79/EC, FDA 21 CFR Part 11 (via HydroControl Software) |
| Key Features | Cell Protection™ Technology, Single-Well Dual-Magnet™ Bead Recovery, Anti-Clogging™ Needle Protection System |
| Design | Onboard Touchscreen Control, Integrated Sensors for Plate Detection & Automation Readiness |
| Plate Compatibility | 96-well and 384-well microplates |
| Application Flexibility | ELISA washing, gentle cell monolayer washing, magnetic bead-based assays, vacuum filtration (optional module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Wellwash / Wellwash Versa Microplate Washer |
| Pricing | Available Upon Request |
| Display | Large-color TFT touchscreen with ergonomic keypad |
| User Interface | Intuitive graphical workflow editor with pre-configured assay templates |
| Fluid Handling | Non-pressurized reservoir system with integrated level sensors (2 L wash buffer bottle, 2 L waste bottle, 8 L rinse head) |
| Aerosol Containment | Integrated anti-aerosol lid with sealed aspiration path |
| Plate Detection | Optical microplate presence sensor (96-well and 384-well compatible) |
| Residual Volume | <2 µL per well after wash cycle (typical, using standard ELISA protocols) |
| Wash Modes | Programmable multi-step washing (pre-wash, main wash, final rinse), customizable soak times, variable aspiration speed control |
| Safety Compliance | Meets IEC 61010-1:2010 for laboratory equipment safety |
| Regulatory Support | Audit-trail ready configuration |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Weight | 10 kg |
| Wash/ Waste Bottle Capacity | 2 L + 2 L |
| Optional Auxiliary Wash Bottle | 2 L |
| Pre-wash Volume | 15–20 mL |
| Max Operating Pressure (Self-limiting) | 0.5 bar |
| Residual Liquid per Well | < 5 µL (avg.) |
| Accuracy | ±5% |
| Operation Mode | Continuous |
| Adjustable Wash Cycles | 1–15 |
| Dispense Volume Range | 0–750 µL |
| Soak Time | 0–10 min |
| Pause Duration | 0–60 s |
| Wash Head Configurations | Interchangeable 8-channel and 12-channel coaxial cannula tips |
| Auto Pump Shut-off Delay | 30 s idle timeout |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | WellWash AC |
| Price | Upon Request |
| Plate Format | 96-well (U-, V-, or flat-bottom) |
| Wash Heads | 8-, 12-, dual 16-, or dual 24-channel |
| Orbital Shaker | 2 mm amplitude, 650–990 rpm |
| Program Memory | 99 main programs (each supporting up to 4 sub-programs) |
| Wash Volume | 50–1000 µL (50 µL increments) |
| Dispense Volume | 50–400 µL |
| Dispense Accuracy | ±5% at 300 µL |
| Dispense Precision | CV ≤3% at 300 µL |
| Aspiration Residual Volume | <3 µL (standard mode), <1 µL (sweep aspiration mode) |
| Aspiration Height | Adjustable |
| Aspiration Mode | Standard or Sweep |
| Soak & Shake Time | 1–60 min |
| Pre-wash & Rinse Volume | 5–100 mL (5 mL increments) |
| Cycle Count | 1–10 |
| Rinse Time | 100 s (dual 12-channel, 3×350 µL), 140 s (dual 8-channel, 3×350 µL) |
| User Interface | 20-key keypad with 8×12-character LCD |
| Communication Port | RS-232 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | Domestic Production |
| Models | Wellwash, Wellwash Versa |
| Instrument Type | Dedicated Microplate Washer |
| Wash Head Configurations | 1×8 and 1×12 (Wellwash) |
| Wash Head Design | Single (Wellwash) |
| Fluid Channels | 1 wash channel + 1 waste channel (Wellwash) |
| Soak Time Range | 0–60 min |
| Wash Cycles | 1–10 |
| Residual Volume per Well | <1.5 µL |
| Plate Shaking | Linear oscillation with low/medium/high intensity adjustment |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Wellwash |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel or 12-channel |
| Rinse Head Design | Single |
| Wash Solution Channels | 1 |
| Soak Time Range | 0–10 min |
| Wash Cycles | 1 |
| Residual Volume per Well | <1.5 µL |
| Plate Shaking Function | Yes |