Life Science Instruments
Filter
Showing 2071–2100 of 2783 results
| Brand | NEPA GENE |
|---|---|
| Origin | Japan |
| Model | PF-NP-200 |
| Temperature Range | −80 °C to Ambient |
| Cooling Rate | −0.1 to −3.0 °C/min |
| Cooling Technology | Stirling Cycle Refrigeration |
| Display | LCD Touchscreen Interface |
| Data Export | CSV Format |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 200 W |
| Dimensions (L×W×H) | 340 × 366 × 466 mm |
| Weight | 18 kg |
| Sample Capacity | 55 × 2 mL Cryovials or 1 × 25 mL Cryobag (optional modules available) |
| Restart Function | Auto-resume after power failure |
| Compliance | Designed for GLP-compliant cell banking and ISO 13485-aligned bioprocessing environments |
| Brand | QIAGEN |
|---|---|
| Origin | Germany |
| Model | NeuMoDx 288 |
| Throughput | 288 tests/8-hour shift |
| Sample Input Volume | 550 µL (from 1 mL tube) |
| Sample Tube Compatibility | Ø11–18 mm × H60–120 mm |
| Reagent Cartridge Format | Closed, single-use microfluidic cartridge |
| Nucleic Acid Extraction | Magnetic bead-based with NeuDry dry-reagent coating |
| PCR Amplification | Integrated real-time qPCR with 5-plex fluorescence detection per reaction |
| Reaction Volume | 19 µL |
| Thermal Control | Silicon-based heating elements for precise ramping and uniform block temperature |
| Internal Control Monitoring | End-to-end process control from lysis to result interpretation |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, GLP/GMP-aligned data integrity framework |
| Regulatory Status | CE-IVDR certified, intended for in vitro diagnostic use |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Neuron SpikerBox Bundle |
| Type | Portable Bioamplifier System for Extracellular Neural Recording and Electrical Stimulation |
| Compliance | CE, FCC, RoHS |
| Software | SpikeRecorder (iOS/Android/macOS/Windows), Open-Source Python SDK Available |
| Battery | 9V alkaline (included) |
| Input Impedance | >100 MΩ |
| Gain | 1,000× (fixed) |
| Bandpass Filter | 100 Hz – 3 kHz |
| Sampling Rate | Up to 48 kHz (via USB or audio jack interface) |
| Electrode Interface | Standard 3.5 mm mono audio jack + alligator clip leads |
| Stimulus Output | Biphasic, current-limited (≤2 mA peak), programmable pulse width (0.1–10 ms) and frequency (1–100 Hz) |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Neuron SpikerBox Pro |
| Sampling Rate | 10 kS/s (2-channel) |
| Frequency Range | 220–3100 Hz |
| Max Sound Pressure Level | 104 dB SPL |
| Neuronal Signal SNR | 30 dB |
| Battery Life | 4 h (full-volume audio mode), 18 h (recording-only mode) |
| Outputs | USB Micro-B, 3.5 mm headphone jack, smartphone audio interface, 2 analog outputs |
| Inputs | 2 × neuron recording leads, 5 × digital inputs OR 3 × digital inputs + 2 × analog inputs |
| Electrical Safety Classification | Type BF (floating body) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-302M |
| Detection Principles | Catalytic Combustion (LEL), Galvanic Cell (O₂), Electrochemical (H₂S, CO) |
| Detection Gases | Combustible Gas (CH₄), Oxygen (O₂), Hydrogen Sulfide (H₂S), Carbon Monoxide (CO) |
| Measurement Ranges | 0–100% LEL |
| 0–25 vol% (extended | 25.1–50 vol%) |
| 0–30 ppm (extended | 30.1–150 ppm) |
| 0–101 ppm (extended | 100–300 ppm) |
| Accuracy | ±2% LEL |
| Response Time | ≤25 s (1 m sampling tube) / ≤40 s (8 m sampling tube) |
| Operating Temperature | −10 °C to +40 °C, ≤95% RH |
| Power Supply | 4 × AA alkaline batteries |
| Continuous Operation | >8 h (20 °C, alarms/background light/data hold OFF) |
| Enclosure Rating | Intrinsic Safety (Ex ibd II BT3), LEL sensor: Flameproof (Ex d) |
| Dimensions | 152 × 152 × 42 mm (excl. protrusions) |
| Weight | ~870 g |
| Display | Backlit LCD (simultaneous 4-gas readout) |
| Alarms | 90 dB audible buzzer, flashing red LED, visual display alert |
| Key Functions | Auto backlight, flow-under detection (pressure sensor), battery/temperature/clock display, zero calibration, data hold, peak hold, alarm silencing, volume adjustment, alarm self-test |
| Standard Kits | 1-m or 8-m sampling hose configurations with filter/floating buoy, carrying case, or aluminum transport case with external alarm & AC adapter |
| Optional | Windows-compatible data logging kit (Windows 2000/XP) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-308B |
| Detection Principle | Potentiostatic Electrolytic (with DNPH-coated filter for VOC interference reduction) |
| Measurement Range | 0.01–0.38 mg/m³ (service range: 0.39–3.00 mg/m³) |
| 0.01–0.30 ppm (service range | 0.31–3.00 ppm) |
| Sampling Method | Micro-pump–driven active aspiration |
| Measurement Duration Options | 10-min or 30-min integrated sampling modes |
| Display | Digital LCD with bar graph and status indicators |
| Power Supply | Six AA alkaline/manganese batteries or optional DC 9 V AC adapter |
| Battery Life | ~50 measurements (30-min mode) / ~100 measurements (10-min mode) using manganese batteries |
| Filter Lifetime | 50 measurements (30-min mode) / 100 measurements (10-min mode) at 0.10 mg/m³ average formaldehyde concentration |
| Operating Temperature | 5–40 °C |
| Dimensions | 175 × 140 × 86 mm (W × H × D) |
| Weight | Approx. 2.5 kg (including batteries) |
| Data Storage | 32 measurement records |
| Accessories Included | Three DNPH filter cartridges, six AA manganese batteries, sampling tube, ten particulate filter discs, tweezers |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3110 |
| Detection Principle | Catalytic Bead (Pellistor) |
| Detection Range | 0–10% LEL and 0–100% LEL (dual-range) |
| Display | 4-digit LCD with backlight |
| Accuracy | ±5% of full scale |
| Response Time (T90) | <3 seconds |
| Alarm Threshold | 20% LEL (audible/visual) |
| Power Supply | 4 × AA alkaline batteries (6 V DC) |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions | 82 mm (W) × 162 mm (H) × 36 mm (D) |
| Weight | ~450 g (including batteries) |
| Sampling Method | Built-in micro diaphragm pump (active draw) |
| Certification | Intrinsically Safe (Ex ib IIB T4 Ga) |
| Compliance | JIS T 8201, JIS Z 8001, JIS C 0901, ATEX Directive 2014/34/EU (via representative EU importer), IEC 60079-0/-11 |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3140 |
| Weight | 450 g |
| Power Supply | AA alkaline batteries or dedicated rechargeable battery pack |
| Display | Dual-mode (digital + bar-graph) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3160 |
| Detection Principle | Catalytic Bead (Contact Combustion) |
| Detection Method | Pump-Aspirated |
| Measurable Gases | Combustible gases & vapors of combustible organic solvents (e.g., diesel, propane, methane, hexane) |
| Range | 0–5000 ppm or 0–1 vol% (auto-ranging) |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Thresholds | 250 ppm / 500 ppm (user-selectable) |
| Display | Backlit LCD with dual-mode output — numeric (0–5000 ppm / 0–1 vol%) and bar-graph scale (auto-switching between L-range: 0–500 ppm / 0–1000 ppm and H-range: 0–5000 ppm / 0–1 vol%) |
| Alarm Output | Audible buzzer + red LED flash (gas/fault) |
| Intrinsic Safety Rating | Ex ib d IIB T3 (combined intrinsic safety + flameproof enclosure) |
| Operating Temperature | −20 °C to +50 °C |
| Power Supply | Four AA alkaline batteries or optional Ni–Cd rechargeable pack |
| Battery Life | ~20 h (alkaline, no alarm/backlight), ~5 h (Ni–Cd, no alarm/backlight) |
| Dimensions | 82 × 162 × 36 mm (W × H × D) |
| Weight | ~450 g (without batteries) |
| Data Logging | Internal memory (standard) |
| Flow Anomaly Self-Check | Yes |
| Accessories Included | Leather carrying case, 4 × AA alkaline batteries, 1 m sampling hose, filter cartridge, filter disc, stainless steel probe tube, rubber suction tip |
| Optional Accessories | Extended sampling hose, gas mixer, data download kit (CD-ROM + USB cable), Ni–Cd battery pack, charger |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-329M |
| Sensor Type | High-sensitivity tin oxide (SnO₂) sintered semiconductor |
| Display | 7-segment LED, 3.5-digit (000–999) |
| Measurement Range | 000–999 arbitrary odor units |
| Repeatability | ±5% ±1 digit (under identical conditions) |
| Sampling Method | Active aspiration (flow rate: 350 ± 100 mL/min) |
| Response Time (90%) | ≤20 s (with calibration odor) |
| Power Supply | 3 × AA alkaline batteries |
| Battery Life | Up to 10 h (at 25°C, typical use) |
| Operating Environment | 0–40°C, 10–80% RH (non-condensing) |
| Storage Environment | −10–50°C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | 60 × 140 × 40 mm (excl. protrusions) |
| Weight | ≈300 g (incl. batteries) |
| Analog Output | DC 0–0.99 V (corresponding to 000–999 display) |
| Data Memory Capacity | 18,000 records |
| Included Accessories | Filter unit, 3 × AA alkaline batteries, set of 10 filter discs |
| Brand | New Environmental Protection Industry in Qingdao |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XY-HS006 |
| Internal Dimensions | 2200 × 1400 × 1500 mm |
| External Dimensions | 2800 × 1300 × 1400 mm |
| Filtration Efficiency | ≥99.95% for 0.3 µm particles |
| Rated Power | ≤3000 W |
| Noise Level | ≤70 dB(A) |
| Air Supply Volume | Not specified (redundant entry in source |
| Occupancy Capacity | 1–3 operators |
| Pass-Through Window Internal Size | 400 × 400 × 400 mm |
| Weight | 500 kg |
| Average Illuminance | ≥350 lx |
| Brand | FUJIKIN |
|---|---|
| Origin | Japan |
| Model | 112-605 |
| Power Supply | 100 V, 50/60 Hz AC |
| Maximum Stack Capacity | 25–30 sheets (64 g/m² paper) |
| Punch Cycle Time | 0.5 s per stroke (50/60 Hz) |
| Dimensions (W×D×H) | 277 × 436 × 308 mm |
| Weight | 37.7 kg |
| Die Block Compatibility | MOLE 605-112 |
| Compliance | Designed for GLP/GMP-aligned documentation integrity workflows |
| Brand | NewtonOptic |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 12 Samples per Run |
| Sample Volume Range | 50–1000 µL |
| Brand | Nexcope |
|---|---|
| Model | NSR950 |
| Technology | Structured Illumination Microscopy (SIM) |
| Laser Wavelengths | 405 nm, 488 nm, 561 nm, 640 nm |
| Lateral Resolution | ≤86 nm (TIRF-SIM), ≤115 nm (3D-SIM) |
| Field of View | Square inscribed in Φ22 mm |
| Imaging Speed | 120 fps |
| Eyepieces | 10× (25 mm field number), EP 17.5 mm, diopter adjustment range −5 to +5 |
| Objectives | 10×, 20×, 40×, 60×, 100× |
| Brand | BIO-RAD |
|---|---|
| Origin | USA |
| Model | NGC NFC |
| Max Flow Rate | 200 mL/min |
| Collection Vessel Compatibility | 96-well plates, microcentrifuge tubes, conical tubes, glass vials, and custom containers |
| Optional Features | Peltier-based cooling (4–25 °C), automated calibration routine |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows, supports audit trail generation per FDA 21 CFR Part 11 requirements (when used with compliant NGC Chromatography Software) |
| Vendor Type | Authorized Distributor |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NicePlate-10 |
| Price Range | USD 1,400 – 2,800 |
| Dispensing Volume Range | 0–30 mL |
| Pump Speed | 0.1–600 rpm |
| Flow Rate | 0.006–2300 mL/min |
| Compatible Vessels | Petri Dishes (standard 90 mm diameter, up to 9 positions), Test Tubes, and Custom Open-Top Containers |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NicePlate-20 |
| Instrument Type | Fully Automatic Microbial Media Dispensing System |
| Dispensing Range | 1–1000 mL |
| Accuracy at 15 mL | ±1% |
| Throughput | 400 Petri Dishes/hour |
| Compatible Dish Diameters | Ø90 mm (standard), 55 mm, 35 mm, 70 mm |
| Adjustable Dish Height | 12–26 mm |
| Dispensing Interval | 1–10 sec |
| UV Lamp Output | 2.3 W @ 254 nm |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | SCIENTZ-08-II |
| Instrument Type | Non-contact ultrasonic cell disruptor (cup-horn system) |
| Operating Frequency | 40 kHz |
| Adjustable Ultrasonic Power | 1800 W |
| Sample Volume Range | 5 µL – 15 mL |
| Sample Capacity | 1–16 tubes |
| Power Adjustment Range | 1–99% |
| Timer Range | 1–999 min |
| Duty Cycle | 0.1–99.9% |
| Tank Volume | 1.5 L |
| Compatible Vessel Formats | 1–2 mL × 16 wells, 5 mL × 8 wells, 10–15 mL × 8 wells |
| Temperature Monitoring | Yes |
| Input Voltage | 220/110 V ±0.5%, 50/60 Hz |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCIENTZ-08-IIIA |
| Pricing | Upon Request |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DSWY-1 |
| Pricing | Available Upon Request |
| Sensor Included | Yes |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NooneLost-2000 |
| Instrument Type | Fully Automated Colony Counter |
| Counting Speed | >400 Petri Dishes per Hour |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Semi-Automatic Colony Counter |
| Counting Speed | >400 samples/h |
| Country of Origin | Domestic (China) |
| Brand | Norhof |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 455 |
| Price | €50,000 |
| Static Evaporation Rate | <0.5 L/day |
| Dispensing Flow Rate | Droplet-to-2 L/min (Fixed, Non-adjustable) |
| Operating Pressure | <200 mBar |
| Hose Pre-cooling Time | 10–40 s (Dependent on LN₂ Level) |
| Power Supply | 115 V / 230 V AC or 12 V AC/DC |
| Average Power Consumption | 10 W (Peak: 50 W) |
| Dewar Capacity | 35 L / 50 L |
| Dewar Diameter | 480 mm / 500 mm |
| Dewar Height | 643 mm / 727 mm |
| Empty/Full Weight | 13 / 41.5 kg (35 L) or 17 / 57.5 kg (50 L) |
| Standard Equipment | Controller, Power Unit, Interconnecting Cables |
| Optional Accessories | 5-Wheel Mobile Base (10 cm height), LN₂ Pump Mounting Bracket |
| Brand | Norhof |
|---|---|
| Origin | Netherlands |
| Model | 606 |
| Static Evaporation Rate | <0.5 L/day |
| Dispensing Flow Rate | 0.1 L/min (dropwise) |
| Operating Pressure | <300 mBar |
| Power Supply | 115/230 V AC or 12 V AC/DC |
| Average Power Consumption | 10 W (50 W during dispensing) |
| LN₂ Tank Capacities | 35 L / 50 L / 100 L |
| Tank Dimensions (Ø × H) | 480 × 791 mm / 500 × 875 mm / 500 × 1235 mm |
| Empty/Full Weight | 13/41.5 kg / 17/57.5 kg / 32/113 kg |
| Tubing | PTFE, OD 6.25 mm, ID 4 mm, insulated with 32 mm foam sheath |
| Control Interface | 5 V TTL trigger (on/off), RS232 serial command set |
| Software | PC-based monitoring suite with real-time pump status, alarm logging (empty tank, <5 L remaining, sensor fault, freeze detection), and mechanical overpressure relief valve |
| Brand | Norhof |
|---|---|
| Country of Origin | Netherlands |
| Model | 608 |
| Supply Voltage | 115/230 V AC or 12–24 V AC/DC |
| Power Consumption | 10 W (avg.), 50 W (during dispensing) |
| Static Evaporation Rate | <0.5 L/day |
| Working Pressure | <300 mbar |
| Precooling Time (1.6 m tubing) | ±1 min |
| Tubing | PTFE, OD 6.25 mm / ID 4 mm, insulated with 32 mm foam jacket |
| LN₂ Tank Options | 35 L / 50 L / 100 L |
| Tank Dimensions (Ø × H) | 480 × 791 mm / 500 × 875 mm / 500 × 1235 mm |
| Empty/Full Weight | 13/41.5 kg / 17/57.5 kg / 32/113 kg |
| Dispensing Control | Timer-based auto-fill (1 level sensor) or external 5 V TTL / RS232 trigger |
| Software Interface | PC-based monitoring suite with real-time pump status, event logging, and configurable alarms |
| Safety Protections | Mechanical overpressure relief valve, low-LN₂ (≤5 L) alert, empty-tank detection, sensor failure alarm, freeze detection |
| Optional Accessories | Bruker FTIR detector adapter, Shimadzu AIM-8800 adapter, 5-wheel mobile base (10 cm height), LN₂ pump mounting bracket, custom sensor mounting fixtures |
| Brand | Norhof |
|---|---|
| Origin | Netherlands |
| Model | 900 |
| Supply Pressure Range | 0.01–270 mBar (adjustable) |
| Flow Rate | Dropwise to 0.5 L/min |
| Maximum Working Pressure | 300 mBar |
| Static Evaporation Rate | <0.5 L/day |
| LN₂ Lift Height | 5 m |
| Power Supply | 115/230 V AC or 12–24 V AC/DC |
| Average Power Consumption | 5 W (50 W during dispensing) |
| Standard Tubing | 2 m length, 4 mm ID / 6.25 mm OD PTFE, insulated with 32 mm foam jacket |
| Integrated LN₂ Dewar Options | 35 L, 50 L, or 100 L |
| System Includes | Dewar, cryogenic pump, 2 m tubing, phase separator, power supply, cables, level sensor(s), PC software |
| Brand | Nuaire |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | NU-543-300S / 400S / 500S / 600S |
| Instrument Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (L×W×H, mm) | 1057 / 1362 / 1669 / 1972 × 799 × 1572 |
| Internal Dimensions (L×W×H, mm) | 873 / 1178 / 1483 / 1788 × 654 × 724 |
| Filter Efficiency | ≥99.995% at 0.3 µm |
| Brand | NuAire |
|---|---|
| Origin | USA |
| Model | NU-543 |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H, mm) | 1057/1362/1669/1972 × 799 × 1572 |
| Internal Dimensions (L×W×H, mm) | 873/1178/1483/1788 × 654 × 724 |
| HEPA Filter Efficiency | ≥99.995% at 0.3 µm |
| Airflow Configuration | 70% recirculated (re-circulated after dual-stage HEPA filtration), 30% exhausted (ducted or via thimble connection) |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, ISO 14644-1 Class 5 (ISO Class 5 equivalent for work area) |
| Brand | NUAIRE |
|---|---|
| Origin | USA |
| Model | NU-5800 Series |
| Temperature Range & Accuracy | Ambient to 55°C |
| Temperature Uniformity | ±0.35°C |
| Humidity Range & Accuracy | 5–90% RH |
| Capacity | 235 L (not lbs — corrected per industry standard |
| Chamber Construction | Seamless 304 stainless steel interior |
| Humidity Recovery | ≤15 min (from door opening) |
| CO₂ Control | IR sensor, 0–20% range, ±0.1% accuracy |
| Sterilization Options | Integrated dry-heat (180°C) and steam-humidity (≥90°C, 95% RH) cycles |
| Filtration | Dual-stage HEPA (99.99% @ 0.3 µm) recirculating air system |
| Compliance | FDA-listed device, ISO 13485-manufactured, CE-marked, compliant with ISO 5, USP <797>, and GLP/GMP environmental monitoring requirements |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MB90 |
| Price | USD 2,950 (approx.) |
| Maximum Capacity | 90 g |
| Readability | 1 mg / 0.01% |
| Temperature Range | 40–200 °C |
| Heating Source | Halogen |
| Display | 4.3" Color Touchscreen |
| Method Storage | 100 methods |
| Result Storage | 1000 records |
| User Management | 3-Level Access Control |
| Interface | RS232, USB |
| Shut-off Modes | Manual, Timed, Auto (A30/A60/A90), Custom |
| Heating Modes | Standard, Rapid |
| Chamber Cleaning | Tool-free disassembly |
| Construction | Die-cast aluminum base |