Life Science Instruments
Filter
Showing 2311–2340 of 2783 results
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SUPEC 6060/7070 |
| Pricing | Upon Request |
| Brand | Supmile |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KBS-650 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz |
| Maximum Ultrasonic Power Output | 650 W |
| Adjustable Power Range | 0–100% |
| Sample Volume Capacity | 0.5–500 mL |
| Processing Volume per Cycle | Up to 600 mL |
| Probe Diameter Options | Φ2, Φ3, Φ8 (standard), Φ10, Φ12, Φ15 mm |
| Duty Cycle Adjustment | 1–999 s |
| Timer Range | 0–24 h |
| Transducer Material | TC4 Titanium Alloy |
| Safety Features | Overload Protection, Audible/Visual Alarm, LED Illuminated Touch Interface, Motorized Vertical Probe Positioning with Wireless Remote Control |
| Structural Design | Modular Stackable Assembly (Optional Integrated or Separated Generator–Transducer Configuration) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SurgiVet V6004 |
| Pricing | Available Upon Request |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | IPA |
| Type | Integrated Electrophysiology Amplifier System with Built-in ADC/DAC |
| Compliance | Designed for Whole-Cell, Cell-Attached, and Voltage/Current-Clamp Recordings |
| Software | SutterPatch v3.x (Real-Time Analysis, Multi-View Oscilloscope, Audit-Trail Data Archiving) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal Programmable Micropipette Puller |
| Heating Mechanism | Dual-Independent Filament (Tungsten/Platinum) |
| Control Architecture | Microprocessor-Based with Ramp Detection Algorithm |
| Program Storage | 100 User-Defined Protocols with Write-Protection and Timestamping |
| Electrode Symmetry | Dual-Output Symmetric Pulling |
| Tip Diameter Reproducibility | Sub-100 nm (verified by SEM) |
| Integrated Gas System | Regulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization |
| Display | Vacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows |
| Brand | SYMCEL |
|---|---|
| Origin | Sweden |
| Model | CalScreener |
| Detection Principle | Isothermal Titration Microcalorimetry (ITC) / Heat Flow Calorimetry |
| Channel Capacity | Up to 32 parallel samples |
| Sensitivity | <50 nW thermal resolution |
| Output Unit | µW (microwatt heat flow) |
| Sample Format | Suspensions, tissue explants, adherent & suspension cells, opaque or turbid media |
| Label-Free Operation | Yes |
| Real-Time Kinetic Data Acquisition | Continuous, unlimited duration |
| Compliance | Designed for GLP-compliant workflows |
| Brand | SYNTECH |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MP-15 |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GIT-WLAN |
| Price Range | USD 14,000 – 28,000 |
| Test Duration | 7 min |
| Continuous Operation Time | ≥2 h |
| Inflation Pressure Range | 500–3000 Pa |
| Pressure Resolution | 0.1 Pa |
| Communication | Wi-Fi |
| Offline Data Storage Capacity | 5000 test records |
| Battery | 12 V Li-ion |
| Power Consumption | ≤20 W |
| Compliance | GB/T 25915.7–2010 / ISO 14644-7:2004 |
| Software Compliance | FDA 21 CFR Part 11 |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HTY Series |
| Pricing | Upon Request |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-22FP·MR |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 20–300 rpm |
| Amplitude | 25 mm |
| Temperature Range | +15°C to +60°C |
| Capacity | 6 × 500 mL Erlenmeyer flasks |
| Cooling Method | Peltier (4 × 70 W) |
| Heating Method | Peltier |
| Temperature Control Accuracy | ±0.2°C |
| Oscillation Mode | Orbital |
| Chamber Dimensions (W×D×H) | 290 × 250 × 270 mm (internal height) |
| Max Load | ~3.5 kg (including platform and fixtures) |
| Power Supply | AC 100 V, 5 A |
| Net Weight | ~49 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | CS-LR |
| Timer Range | 0–99 h |
| Oscillation Frequency | 15–200 rpm |
| Amplitude | 25 mm (factory-set, optional 20 mm) |
| Temperature Range | 0–50 °C |
| Platform Size | 300 × 200 mm |
| Load Capacity | ~3 kg |
| Humidity Tolerance | ≤95% RH ±5% |
| Construction | SUS304 Stainless Steel Body & KENIFINE™-Coated Platform |
| Safety | Fuse, Motor Overload Protection, Overvoltage Protection |
| Dimensions (Shaker) | 302 × 240 × 129 mm |
| Weight (Shaker) | ~7 kg |
| Power Supply | AC 100 V, 1 A |
| Control Box Dimensions/Weight | 125 × 30 × 70 mm / ~0.5 kg |
| Standard Accessories | AC adapter, reciprocal/rotary mode bar, 2-m power cable |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | GM-01 |
| Instrument Type | Bead Mill Cell Disruptor |
| Temperature Range | 0 °C to 40 °C |
| Sample Volume | 2.0 mL per tube |
| Throughput | Up to 12 samples (6 with metal beads) |
| Maximum Centrifugal Force | 1300 × g |
| Speed Range | 500–4500 rpm |
| Vortex Mixing Intensity | 10 levels (Level 10 ≈ 2600 rpm equivalent shear) |
| Timer Range | 0–50 sec, or 1 min–99 h 50 min |
| Dimensions | 210 × 268 × 176 mm (W × D × H) |
| Weight | ~3.5 kg |
| Power Supply | AC 100–125 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M·BR-420FL |
| Temperature Range | +4°C to +70°C |
| Temperature Accuracy | ±0.3°C to ±1.0°C |
| Oscillation Speed | 200–1500 rpm (reversible mode ≤1000 rpm) |
| Timer Range | 00h00m to 99h59m |
| Oscillation Mode | Horizontal eccentric motion with reversible function |
| Heating Power | 800 W |
| Cooling System | Compressor-based refrigeration (140 W) |
| Display | Digital LED for temperature and speed |
| Programmable Profiles | 4 programs × 9 steps (temperature, speed, time, hold function) |
| Dimensions (W×D×H) | 600 × 732 × 643 mm |
| Weight | ~100 kg |
| Electrical Supply | AC 100 V, 12 A |
| Platform Capacity | Up to 24 microplates (4 layers × 6 positions) or 12 deep-well plates (2 layers × 6 positions) |
| Operating Ambient Temperature | +5°C to +35°C |
| Compliance | Designed for GLP-compliant labs |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MG-1300M-2A |
| Price Range | USD 14,000 – 70,000 (FOB) |
| Temperature Control Range & Accuracy | +5°C above ambient to +40°C, ±0.5°C uniformity in chamber, ±0.2°C in culture vessel (at +37°C, 5% CO₂, 25°C ambient) |
| Humidity Control | Not equipped |
| Capacity | Two 40-layer multilayer cell culture vessels (e.g., CellMASSter, Cell Factory, CellSTACK) |
| Heating Method | Quadruple-wall air-jacketed + inline gas stream heating |
| CO₂ Sensor | NDIR infrared (IR) type, control range 3.0–8.0%, resolution 0.1% |
| O₂ Sensor | Zirconia-based electrochemical sensor, display range 1–25% |
| Gas Flow | 2 L/min × 2 independent channels |
| Air Circulation | Horizontal laminar flow fan |
| Data Logging | Built-in Windows XP PC with 6.5" touchscreen, CSV/TXT export |
| Safety Features | Dual-stage overtemperature protection (electronic + liquid-expansion mechanical), controller fault alarm (audible), door-open interlock |
| Construction | Interior and exterior stainless steel (SUS304) |
| Dimensions (W×D×H) | 1280 × 950 × 1930 mm (excluding protrusions) |
| Standard Accessories | Two motorized rotating platforms for 40-layer vessels (incl. leveling mechanism and transport cart), one shelf for 10-layer vessels |
| Compliance | Designed for GLP-compliant bioprocess environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Mix-VR / Mix-EVR |
| Oscillation Mode | Orbital (Mix-VR) / Horizontal Eccentric (Mix-EVR) |
| Speed Range | 50–500 rpm (Mix-VR), 250–2500 rpm (Mix-EVR) |
| Amplitude | 10 mm (Mix-VR), 2 mm (Mix-EVR) |
| Operating Temperature Range | 0 °C to 50 °C |
| Platform Dimensions | 300 × 200 mm (standard) |
| Max Load Capacity | ~2 kg (excl. platform & fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Weight | 12.2 kg (Mix-VR), 6.5 kg (Mix-EVR) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | MM-10, ML-10F |
| Temperature Range | Ambient +5°C to 80°C (MM-10), 0°C to 50°C (ML-10F) |
| Temperature Accuracy | ±0.02–0.1°C (MM-10), ±0.05–0.2°C (ML-10F) |
| Oscillation Mode | Reciprocating |
| Adjustable Amplitude | 10–40 mm (stepless) |
| Speed Range | 20–160 rpm |
| Platform Dimensions | 400 × 300 mm (MM-10), 530 × 365 mm (ML-10F) |
| Water Bath Capacity | ~25 L (60% fill, MM-10), ~35 L (80% fill, ML-10F) |
| Heating Power | 1.3 kW (MM-10), 800 W (ML-10F) |
| Cooling System | Integrated refrigeration unit (125 W, ML-10F only) |
| Safety Features | Dual-loop thermal cutoff, dry-run protection, overtemperature sample safeguard, sensor fault self-diagnosis, ΔT display, remote temperature setting |
| Compliance | Designed for GLP-compliant microbiological and mutagenicity assay workflows including OECD 471 and ISO 10993-3 |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model | NR-150 (Single-Tier), NR-150 Dual-Tier |
| Timing Range | 0 min – 99 h 59 min |
| Oscillation Speed | 25–250 rpm (NR-150), 25–160 rpm (Dual-Tier) |
| Amplitude | 10–50 mm (infinitely adjustable) |
| Platform Dimensions | 600 × 400 mm |
| Max Load Capacity | 26 kg (including platform and fixtures) |
| Power Supply | AC 100 V, 2 A |
| Safety Features | Motor overload protection circuit, fuse |
| Weight | 73 kg (NR-150), 83 kg (Dual-Tier) |
| Dimensions (W×D×H) | 760 × 585 × 350 mm (NR-150), 760 × 585 × 789 mm (Dual-Tier) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | NR-5100 (single-layer) / Dual-Layer NR-5100 |
| Oscillation Mode | Reciprocating |
| Speed Range | 25–250 rpm (NR-5100), 25–180 rpm (dual-layer) |
| Amplitude Options | 25 / 50 / 70 mm (factory-set to 70 mm) |
| Platform Dimensions | 1200 × 860 mm |
| Load Capacity | ~36 kg per layer |
| Operating Temperature Range | +5 °C to +40 °C |
| Power Supply | AC 100 V, ≤2 A |
| Weight | ~460 kg (single), ~480 kg (dual) |
| Safety Features | Leakage circuit breaker, motor overload protection, fuse |
| Compliance | Designed for GLP-compliant bioprocess environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Personal-11 |
| Temperature Range | Room Temp +5°C to +85°C |
| Oscillation Frequency | 20–160 rpm |
| Oscillation Amplitude | 10–40 mm (infinitely adjustable) |
| Timer Range | 0.1–999.9 h |
| Chamber Capacity | ~11 L (at 80% fill level) |
| Platform Dimensions | 220 × 310 mm |
| Construction | Stainless steel wetted parts |
| Power Supply | AC 100 V, 7 A |
| Weight | ~19 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Personal-11•SDN Combination |
| Instrument Type | Water Bath Incubator Shaker |
| Oscillation Mode | Reciprocating |
| Temperature Range | +5 °C to +70 °C |
| Temperature Uniformity | ±0.1 °C to ±0.3 °C |
| Oscillation Frequency | 20–160 rpm |
| Amplitude Adjustment | 10–40 mm (continuously variable) |
| Platform Configuration | Modular dual-platform system (shaking platform + water bath trough) |
| Timing Options | Programmable digital timer (multiple preset intervals) |
| Platform Compatibility | Interchangeable trays for flasks, tubes, microplates, and custom vessels |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | PR-12 |
| Timer Range | 60 min |
| Oscillation Speed | 20–120 rpm |
| Oscillation Angle | 5°–8° (continuously adjustable) |
| Platform Dimensions | 150 × 150 mm |
| Max Load Capacity | 800 g (including fixture) |
| Power Supply | AC 100 V, 0.5 A |
| Net Weight | ~2.5 kg |
| Footprint | 170 × 180 × 166 mm (W × D × H) |
| Brand | TAITEC |
|---|---|
| Origin | China (Beijing) |
| Manufacturer Status | Authorized Distributor |
| Product Type | Separatory Funnel Shaker |
| Model | SR-2EW / SR-2ES / SR-2DW / SR-2DS |
| Timing Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 50–300 rpm |
| Oscillation Amplitude | 40 mm |
| Number of Funnel Positions | 10 (dual-side configuration) |
| Noise Level | ≤45 dB(A) |
| Load Capacity per Side | 7.5 kg (including platform) |
| Dimensions (SR-2ES) | 410 × 585 × 500 mm |
| Dimensions (SR-2EW) | 410 × 760 × 500 mm |
| Weight (SR-2ES) | 49 kg |
| Weight (SR-2EW) | 57 kg |
| Power Supply | AC 220 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | TS-10 |
| Oscillation Mode | Reciprocating |
| Speed Range | 50–250 rpm |
| Amplitude | 45 mm (fixed) |
| Max Load Capacity | 10 kg (excluding platform) |
| Timer Function | Dual-stage timer (start time + runtime |
| Platform Compatibility | Interchangeable platforms for PE bottles, test tubes, flasks, vials, and mesh supports |
| Power Consumption | 70 W |
| Dimensions | 740 × 439 × 459 mm (H) |
| Weight | ~70 kg |
| Voltage | AC 100 V |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | TS-20 |
| Oscillation Mode | Reciprocating |
| Speed Range | 25–200 rpm |
| Amplitude | 10–50 mm (continuously adjustable) |
| Max Load Capacity | ~20 kg (excluding platform and clamping rods) |
| Timer Function | Dual independent timers (start time + runtime), up to 300 h total |
| Platform Configuration | Multi-plate compatible |
| Power Supply | AC 100 V, 1 A |
| Power Consumption | 70 W/h |
| Dimensions | 820 × 601 × 591 mm (H) |
| Weight | ~100 kg |
| Standard Accessories | Long clamping rods (×4), short clamping rods (×4), timer adjustment wrench |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VIX-100 |
| Timer Range | 15 min |
| Oscillation Speed | up to 2000 rpm |
| Platform Configuration | Single or Dual Shaking Plates |
| Operating Temperature | Ambient |
| Applicable Vessels | 20 mL glass vials (100 units), capped tubes up to 180 mm in length |
| Platform Dimensions | 325 × 325 mm |
| Power Supply | AC 100 V, 2 A |
| Weight | ~32 kg |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VP-050N / VP-300N |
| Output Power | 50 W (VP-050N), 300 W (VP-300N) |
| Frequency Range | 19.5–20.5 kHz (VP-050N), 19–21 kHz (VP-300N) |
| Transducer Interface | Integrated horn-type piezoelectric converter with auto-tuning |
| Control | Digital LCD interface with real-time % output, current, temperature (*optional sensor), timer (1 s–120 min), and pulse mode (ON/OFF: 0.1–60 s) |
| Probe Options | Φ2 mm, Φ3 mm, Φ6 mm stepped microprobes (VP-050N) |
| Dimensions (W×D×H) | 122×288×283 mm (VP-050N), 143×360×283 mm (VP-300N) |
| Weight | 4.5 kg (VP-050N), 6.7 kg (VP-300N) |
| Power Supply | AC 100 V, 1 A (VP-050N), AC 100 V, 5 A (VP-300N) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Wave-PR / Wave-SI / Wave-SI Slim |
| Oscillation Frequency | 5–50 rpm (Wave-PR), 10–60 rpm (Wave-SI & Wave-SI Slim) |
| Oscillation Angle | 2°–6° (adjustable, Wave-PR), 2°–10° (adjustable, Wave-SI), 6° (fixed, Wave-SI Slim) |
| Operating Temperature Range | 0 °C to +50 °C |
| Platform Quantity | 1 |
| Platform Dimensions | 300 × 200 mm (Wave-PR), 180 × 120 mm (Wave-SI), 180 × 130 mm (Wave-SI Slim) |
| Max Load Capacity | ~2 kg (excluding platform and fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-01 |
| Disruption Principle | Horizontal umbrella-shaped oscillation |
| Speed Range | 2,500–4,600 rpm (6 preset steps) |
| Sample Volume | 2 mL |
| Sample Capacity | 1 tube per run |
| Compatible Beads | Glass, zirconia, stainless steel beads (φ0.15–6 mm), metal mortars |
| Operating Temperature | +5 to +35 °C |
| Vibration Frequency | 40–78 Hz |
| Timer Range | 5–60 s (6 presets) |
| Safety Features | Lid interlock stop, overload current protection |
| Dimensions | 172 × 280 × 160 mm (W × D × H) |
| Weight | ~5 kg |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-12 |
| Instrument Type | Bead Mill Cell Disruptor |
| Operating Frequency | 53 Hz |
| Sample Capacity | 12 × 5.0 mL tubes |
| Throughput | 12 samples per run |
| Speed Range | 1,800–3,200 rpm (8-step digital adjustment) |
| Timer | 1–300 s (1-s increment, memory for 2 speed/time presets) |
| Safety Features | Lid-interlock shutdown, overload current protection |
| Dimensions | 310 × 400 × 200 mm (W × D × H) |
| Weight | ~15 kg |
| Power Supply | AC 100 V, 4 A |
| Ambient Operating Range | +5 °C to +35 °C |
| Tube Compatibility | Standard threaded 1.5/2.0 mL and 5.0 mL microtubes (e.g., Watson 1392-200, 2332-105) |
| Bead Compatibility | Stainless steel (SUS), zirconia, glass beads |
| Brand | TAIYO NIPPON SANSO |
|---|---|
| Origin | Japan |
| Model | MR-LN-6000 |
| Capacity | 6 L (liquid nitrogen hold time ≥4 h at ≤−150 °C in 25 °C ambient) |
| Temperature Monitoring | Integrated digital temperature recorder with transparent lid display |
| Insulation | High-vacuum multilayer insulation (MLI) + adsorbent-based vapor-phase stabilization |
| Compliance | Designed for ISO 13485-aligned biologics handling environments |
| Regulatory Context | Supports GLP-compliant sample chain-of-custody documentation |