| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Gene Pulser Xcell |
| High Voltage Range | 3000 V |
| Low Voltage Range | 10 V |
| Pulse Duration | 0.05–10 ms (0.05 ms increments) for 10–500 V |
| Number of Pulses | 1–10 (0.1–10 s interval for 10–500 V) |
| Capacitance | 25–3275 µF (25 µF increments) at 10–500 V |
| Resistance | 50–1000 Ω (50 Ω increments) + ∞ |
| Brand | Bio-Rad |
|---|---|
| Model | Helios |
| Origin | USA |
| Type | Handheld Particle-Mediated Gene Delivery System |
| Operating Pressure Range | 100–600 psi |
| Safety Relief Valve Setpoint | 700 ± 35 psi |
| Max. Helium Pressure Adjustment | 800 psi |
| Power Supply | 9 V Alkaline Battery (rechargeable optional) |
| Battery Life | ≥1,000 discharges |
| Max. Discharge Current | 10 mA (gun unit) |
| Input Voltage | 100–120 V or 220–240 V AC, 50/60 Hz |
| Cartridge Spinning Speed | 30 rpm |
| Gold Particle Diameters | 0.6, 1.0, and 1.6 µm |
| PVP Coating Mass | 0.5 g per kit |
| Desiccant | Spherical drying agent (5 units) |
| Cartridge Capacity | 12 firings per chamber |
| Kit Contents | 1,000 pre-loaded cartridges, 50 ft (~26 m) gold-coated tubing, 5 gene storage vials |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | MicroPulser |
| High Voltage Range | 300–3000 V |
| Low Voltage Range | 200–2500 V |
| Pulse Duration | 0.1–5.0 ms (adjustable in 0.1 ms increments) |
| Capacitance Settings | 100, 250, 500, and 1000 µF |
| Internal Resistance | Fixed ~100 Ω (optimized for standard electroporation cuvettes) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | PDS-1000/HE |
| Helium Pressure Range | 450–2200 psi |
| Vacuum Chamber | Adjustable to ≤29 inHg (737 mmHg) |
| Carrier Disk Diameter | 13 mm |
| Stopping Screen Material | Stainless Steel Mesh (100 µm pore) |
| Microprojectile Size Compatibility | 0.6–1.6 µm (Au or W) |
| Pulse Duration | <1 ms (transient helium shockwave) |
| Capacitance | Not applicable (gas-driven, non-electrical acceleration) |
| Resistance | Not applicable (pneumatic system) |
| Brand | BLS |
|---|---|
| Origin | Hungary |
| Model | CF-150C |
| Pulse Voltage Range (Square Wave) | 12–185 V |
| Pulse Duration | 10–200 µs |
| Inter-Pulse Interval | 200 µs |
| Pulse Count | 1–10 |
| HF Oscillator Frequency | 1 MHz ±100 Hz |
| HF Amplitude (Coarse) | 0–30 V<sub>eff</sub> |
| HF Amplitude (Fine) | 0–3 V<sub>eff</sub> |
| Operating Medium | Electrolytic or Non-electrolytic Solutions |
| Dimensions | 200 × 130 × 45 mm |
| Weight | 380 g |
| Power Consumption | 15 VA |
| Protection Class | Class I (Earthed) |
| Brand | BLS |
|---|---|
| Origin | EU-manufactured |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | European Union |
| Model | CF150B |
| Pricing | Available upon Request |
| Brand | BLS |
|---|---|
| Origin | Europe |
| Manufacturer Type | OEM Equipment Manufacturer |
| Country of Origin | Imported (EU) |
| Model | DN-10 |
| Pricing | Available Upon Request |
| Brand | BLS |
|---|---|
| Model | FBL/Basic-B&N-01 |
| Power Supply | Dual-mode (battery or AC/DC adapter) |
| Excitation Wavelength Range | 470–660 nm |
| Emission Detection Range | 500–650 nm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM 830 |
| Pricing | Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 830 |
| High Voltage Range | 505–3000 V |
| Low Voltage Range | 5–500 V |
| Pulse Duration | 10 ms–10 s |
| Capacitance | 111 µF |
| Resistance | 25 Ω |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001 |
| Category | Imported |
| Distributor Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001 |
| Type | Dual-Mode Electroporator/Electrofusion Instrument |
| Compliance | Designed for GLP-compliant cell manipulation workflows |
| Software Interface | Analog control with manual pulse parameter adjustment |
| Pulse Modes | AC pre-alignment, DC square-wave fusion, AC post-aggregation |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001+ |
| High-Voltage Range | 505–3000 V |
| Low-Voltage Range | 5–500 V |
| Pulse Duration | 10 µs–999 ms |
| Resistance Setting | 1 Ω |
| Compliance | CE, FDA-listed device for research use only |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM399 |
| Type | Square-Wave & Exponential Decay Electroporator |
| Application Scope | Mammalian, Bacterial, Yeast, Plant & Primary Cell Transfection and Electrofusion |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ECM399 |
| Pricing | Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM630 |
| Voltage Range | 10–500 V (low-voltage mode), 50–2500 V (high-voltage mode) |
| Capacitance | 1 µF, 25–3275 µF (25 µF increments in low-voltage mode) |
| Resistance | 25–1575 Ω (25 Ω increments, high-voltage mode only) |
| Pulse Type | Exponential decay |
| Max. Current Limit | 6000 A (LV), 3000 A (HV) |
| Charge Time | ≤5 s |
| Safety | Short-circuit protection with 10 s max delay |
| Display | 20×4-character LCD |
| Dimensions | 31.8 × 31.1 × 14.0 cm (W×D×H) |
| Weight | 4.5 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM630 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | ECM830 |
| High-Voltage Mode | 50–3000 V (5 V step), 56 Ω, 111 µF, pulse width 10–600 µs (1 µs resolution) |
| Low-Voltage Mode | 5–500 V (1 V step), 56 Ω, 4000 µF, pulse width 10–999 µs / 1–999 ms / 1–10 s (1 µs / 1 ms / 0.1 s resolution) |
| Pulse Number | 1–99 |
| Inter-Pulse Interval | 100 ms–10 s |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Models | BTX 610, BTX 620, BTX 640 |
| Sterility | Gamma-Irradiated, Individually Packed |
| Electrode Material | Embedded Aluminum |
| Electrode Gap Options | 1.0 mm, 2.0 mm, 4.0 mm |
| Maximum Electric Field Strength | 25 kV/cm |
| Cap Design | Leak-Resistant Snap-On Cap |
| Volume Range per Cuvette | 20–800 µL |
| Packaging | 50 sterile units per box |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gemini SC |
| Price Range | USD 68,000 – 109,000 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| High-Voltage Range | ±3000 V |
| Low-Voltage Range | 5 V |
| Pulse Duration | 10 µs – 999 ms |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MOS High-Throughput Multiwell Electroporation System |
| Quotation | Available Upon Request |
| Pulse Generator Compatibility | ECM630 & ECM830 |
| MOS Plate Formats | 25-well & 96-well |
| MOS Plate Processor Models | HT-100 (manual column-by-column pulsing) & HT-200 (automated sequential column pulsing) |
| Voltage Range | 0–3000 V DC |
| Pulse Duration | 10 µs – 10 s |
| Number of Pulses | 1–99 |
| Electrode Architecture | Patented composite electrode array with cross-contamination mitigation design |
| Included Accessories | Sterile plate lid for contamination control |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Hybrimune |
| Capacity Options | 2 mL (microscope-compatible transparent chamber) & 9 mL fusion chambers |
| AC Pre-Fusion Pulse | 0.2–2.0 MHz (0.2 MHz step), 5–75 V (0.1 V step), 0–60 s (1 s step), non-sinusoidal ramp-up waveform |
| AC Post-Fusion Pulse | same frequency/voltage range, ramp-down waveform |
| DC Fusion Pulse | square wave, 100–1000 V (5 V step), 20–1000 µs (10 µs step), 0–10 pulses, 0.125–10 s inter-pulse interval |
| Cycles | 1–10 sets |
| Operating Temperature | 20–30 °C |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hybrimune Large-Scale Fusion System |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BTX MAX Transfection System |
| Pricing | Available Upon Request |
| Electroporation Chamber Gap | 4 mm |
| Sample Volume Range | 2–6 mL |
| Voltage Range | 50–1200 V |
| Pulse Duration | 0.05–10 ms |
| Inter-Pulse Interval | 0.2–1000 ms (1 Hz–5 kHz) |
| Data Interface | USB Flash Drive Support |
| Control Interface | Capacitive Touchscreen |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 454 |
| Pricing | Available Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Model 524 |
| Electrode Type | Reusable tweezer-style in vivo electroporation electrode |
| Electrode Disk Diameter Options | 7 mm (Model 520) or 10 mm (Model 523) |
| Adjustable Inter-Electrode Gap | <1 mm to >20 mm |
| Compatible Pulse Generators | BTX ECM 830, ECM 630, ECM T820, ECM 2001 |
| Electrode Material | Stainless steel |
| Sterilization Method | Ethanol or ethylene oxide |
| Connection | BTX Model 524 Cable |
| Compliance | Designed for GLP-compliant preclinical research workflows |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Model | Eporator |
| Voltage Presets | P1 = 1700 V, P2 = 2500 V |
| Display | Color LCD Interface |
| Safety | Integrated Electrode Slot with Leakage Protection |
| Compliance | GLP-Compliant Data Logging via USB |
| Dimensions | Compact Benchtop Form Factor |
| Regulatory Status | Import-Class Life Science Instrument for Transfection and Cell Fusion Applications |