| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5% vol CO₂ |
| Repeatability | ±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol) |
| Resolution | 0.01% vol |
| Response Time (T90) | 20 s |
| Zero Drift | ≤±5% FS |
| Span Drift | ≤±1% FS |
| Linearity Error | ≤±2% FS |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Battery Life | 12 h (fully charged or with two AA alkaline batteries) |
| Acoustic Alarm | 95 dB @ 30 cm |
| Man-Down/Emergency Alarm | 110 dB @ 30 cm |
| Visual Indication | Tri-color LED status (green/yellow/red) |
| Display | High-contrast OLED |
| Data Logging | Internal storage with PC export capability |
| Brand | AFRISO |
|---|---|
| Model | STM225 |
| Type | Portable dust monitor |
| Measurement Principle | Dual-beam laser scattering |
| Dust Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (Indication Error) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Response Time | ≤0.10 s |
| Drift Stability | <1% over 1 h |
| Operating Temperature | –5 to 40 °C |
| Storage Temperature | –20 to +50 °C |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| IP Rating | IP40 |
| Display | 5.7" color TFT touchscreen |
| Power Supply | AC 230 V, 50 Hz |
| Communication | Bluetooth 4.2, USB |
| O₂ Range (with M60) | 0–21 vol.% |
| CO/H₂ Range (with M60) | 0–4000 ppm |
| COhigh Range (with M60) | 0–20,000 ppm |
| Brand | AFRISO |
|---|---|
| Model | STM225 |
| Type | Portable dust monitor |
| Measurement principle | Dual-beam laser scattering |
| Dust concentration range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (indicated error) | ±0.50 mg/m³ |
| Repeatability | ±0.2 mg/m³ |
| Response time | 0.10 s |
| Stability | ±1% over 1 h |
| Operating temperature | −5 to 40 °C |
| Storage temperature | −20 to +50 °C |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| Ingress protection | IP40 |
| Display | 5.7" color touchscreen |
| Power supply | AC 230 V, 50 Hz |
| Communication interfaces | Bluetooth, USB |
| Brand | AFRISO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable Flue Gas Analyzer |
| Model | M60X20 |
| Accuracy (SO₂/NO/NO₂) | ±10 ppm (0–200 ppm), ±5% of reading (>200 ppm) |
| Accuracy (CO) | ±5 ppm (0–50 ppm), ±5% of reading (>50 ppm) |
| Repeatability | ±2% |
| Response Time (T90) | ≤45 s (SO₂), ≤30 s (NO, CO), ≤60 s (NO₂, COhigh) |
| Stability | ±0.1% of full scale over 8 hours |
| Measured Gases | O₂, CO (H₂-compensated), COhigh, NO, SO₂, NO₂, CO₂ (IR), calculated λ, CO₂, η-efficiency, flue gas loss, dew point, ΔT |
| IP Rating | IP42 |
| Operating Temperature | 5–40 °C |
| Weight | 685 g (with magnetic protective case) |
| Brand | AFRISO |
|---|---|
| Origin | Germany (manufactured under AFRISO engineering specifications |
| Model | STM225 |
| Instrument Type | Portable flue gas particulate monitor |
| Measurement Principle | Dual-beam laser scattering (90° and forward-angle detection) |
| Dust Concentration Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (Indication Error) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (T90) | ≤0.1 s |
| Drift (1 h) | <±1% FS |
| Operating Temperature | −5 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| Ingress Protection | IP40 |
| Display | 5.7″ color TFT touchscreen |
| Power Supply | AC 230 V, 50 Hz |
| Communication | Bluetooth 5.0, USB 2.0 |
| Compliance | EN 15267-3 (QAL1 certified per EU Directive 2010/75/EU), ASTM D6216, ISO 12141, applicable to continuous emission monitoring systems (CEMS) auxiliary particulate verification |
| Brand | AFRISO |
|---|---|
| Origin | Germany (manufactured under AFRISO engineering specifications |
| Model | STM225 |
| Instrument Type | Portable Laser-Based Dust Monitor |
| Measurement Principle | Dual-Beam Laser Light Scattering |
| Dust Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (Indicated Error) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (T90) | ≤0.1 s |
| Drift (1-h Stability) | <±0.5% FS over 1 h |
| Operating Temperature | –5 to +40 °C |
| Storage Temperature | –20 to +50 °C |
| Display | 5.7" color TFT touchscreen |
| Power Supply | AC 230 V, 50 Hz |
| Communication | Bluetooth 4.2, USB 2.0 |
| Enclosure Rating | IP40 |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | 7.5 kg |
| Compliance | Designed to support ISO 16940, EN 13284-1, and ASTM D6216 measurement protocols for particulate matter in industrial flue gases |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-8101 |
| Rainfall Detection Sensitivity | ≥0.03 mm/min |
| Lid Opening Response Time | ≤30 s |
| Lid Closing Response Time | ≤5 min |
| Measurable Rainfall Intensity Range | 0.03–4 mm/min |
| Measurement Accuracy | ±1% |
| Collection Funnel Diameter | 300 mm |
| Dust Deposition Cylinder Height | 150 mm |
| Sampling Bucket Capacity | 15 L |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤98% RH |
| Dimensions (L×W×H) | 1200 × 550 × 1000 mm |
| Weight | ~40 kg |
| Power Supply | AC 220 V (±10%), 50 Hz |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-120F(GK) |
| Sampling Flow Rate | 80–120 L/min |
| Maximum Negative Pressure | >26 kPa |
| Flow Stability | ≤±5% over 1 h |
| Flowmeter Accuracy | ≥±2.5% |
| Service Life at Max Flow & Backpressure | ≥5000 h |
| Continuous Operation Time at Max Flow & Max Resistance | 2–8 h with flow deviation ≤±5% |
| Instrument Type | Single-Channel Gas Sampler |
| Compliance | HJ/T 374–2007, HJ 93–2013, HJ 656–2013, HJ 657–2013, HJ 691–2014, HJ 480–2009, JJG 943–2011 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-ZFB05 |
| Pricing | Available Upon Request |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-2 |
| Instrument Type | Flue Gas Sampler |
| Sample Medium | Flue Gas |
| Flow Accuracy | ±5% |
| Adjustable Sampling Flow Rate | 0.5–2.0 L/min |
| Pre-Flow Pressure Range | −30 to 0 kPa |
| Pre-Flow Temperature Range | −30 to +99 °C |
| Atmospheric Pressure Measurement Range | 70–130 kPa |
| Data Storage Capacity | 1000 sets |
| Operating Temperature | −30 to +50 °C |
| Dimensions (L×W×H) | 225 × 160 × 280 mm |
| Weight | ~3 kg |
| Power Supply | AC 220 V ±10%, 50 Hz or DC 12 V |
| Power Consumption | <20 W |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-JC |
| Material Options | Organic Glass / Borosilicate Glass / Ceramic |
| Internal Diameter | 15.0 ± 0.5 cm |
| Height | 30.0 cm |
| Base | Flat and Level |
| Internal Surface | Smooth, Non-Porous, Chemically Inert |
| Compliance | Designed to Fully Conform with HJ 1221–2021 “Determination of Total Dust Fall in Ambient Air — Gravimetric Method” |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3160 |
| Detection Principle | Catalytic Contact Combustion |
| Detection Range | 0–5000 ppm or 0–10,000 ppm (selectable) |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Thresholds | 250 ppm or 500 ppm (configurable) |
| Display | Backlit LCD with dual-mode numeric + bar-graph analog simulation |
| Power Supply | 4 × AA alkaline batteries (~20 h continuous operation, methane spec.) |
| Enclosure Rating | Intrinsically Safe Ex ib d IIC T3 (sensor housing: flameproof) |
| Certification | NK Type Approval No. 06T605, CE compliant (upon request) |
| Operating Temperature | –20 °C to +50 °C (0–40 °C for iso-butane spec.) |
| Dimensions | 82 × 162 × 36 mm |
| Weight | ~450 g (excl. batteries) |
| Sample Draw Method | Motorized suction pump with flow anomaly detection |
| Auto-ranging | Dual L/H range switching based on concentration |
| Standard Accessories | Leather case, 1 m sampling tube, exhaust filter, filter element, rubber suction tip |