Lubricating Oil Tester
Filter
Showing 31–60 of 125 results
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 001-001-331 |
| Test Type | Friction and Wear |
| Load Capacity (Standard) | 805 lbf |
| Load Capacity (Optional) | 1300 lbf |
| Speed Range | Programmable RPM Control |
| Temperature Range (Standard Chamber) | Ambient to 200 °C |
| Temperature Range (Pressurized Chamber, Optional) | Ambient to 250 °C |
| Sub-ambient Testing | Available with External Chiller |
| Friction Force Measurement Range (Standard) | 0–250 lbf |
| Friction Force Measurement Range (Optional Low-Load Sensor) | 0–25 lbf |
| Compliant Standards | ASTM D2714, D2981, D3704, D2509, D2782, G77 |
| Test Geometries | Block-on-Ring, Conforming Block-on-Ring, Timken Canted Cylinder, Chip-on-Ring, Ball-on-Ring |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 006‐001‐330 |
| Testing Type | Friction and Wear |
| Compliance | ASTM D3702, D2266, D4172, D5183, G99 |
| Speed Range | 30–3600 rpm (standard), 0.01–10,000 rpm (with optional gear reducer) |
| Load Range | 1–160 lbf (2:1 lever), 20–800 lbf (10:1 lever) |
| Temperature Range | Ambient to 150°C (standard), 30–200°C (with optional heating/cooling modules) |
| Control | Computer-controlled servo motor, pneumatic auto-loading (programmable), real-time torque & displacement monitoring |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 016-001-002 |
| Test Method Compliance | ASTM D3336, SH/T 0428 |
| Maximum Rotational Speed | 20,000 rpm (light-load condition) |
| Axial Load Capacity | 15 lbs (mechanically applied) |
| Heating Chamber Max Temperature | 371 °C |
| Torque Measurement | Digital display with high/low torque shutdown threshold |
| Drive Motor | Dual 1 HP, single-phase AC motors with thermal protection |
| Timing Control | Digital on/off elapsed-time counter |
| Standard Shaft | CRC-type shaft |
| Application Focus | Grease-lubricated ball bearing life evaluation under accelerated thermal–mechanical stress |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 081-001-005 |
| Test Principle | Oscillating Ball-on-Cylinder Tribometry |
| Applied Load | 2450 N (550 lbf) |
| Test Duration | 22 h |
| Oscillation Frequency | 30.0 Hz (1800 cpm) |
| Compliance Standards | ASTM D4170, SH/T 0716 |
| Optional Feature | Load Uniformity Adjustment System |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 089-001-001 |
| Testing Mode | Wear, Extreme Pressure (EP), and KRL Rolling Fatigue |
| Speed Range | 1–2500 rpm |
| Load Range | 1–1000 kg (standard) |
| optional low-load system | 0–150 ±0.2 kg |
| Compliance | ASTM D2266, D4172, D5183, D2596, D2783 |
| Safety | Interlocked pneumatic loading enclosure |
| Control | Touchscreen interface with programmable cycle counter and elapsed time timer |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 002‐001‐003 |
| Testing Principle | Timken EP Test (ASTM D2509, ASTM D2782, SH/T 0203) |
| Maximum Applied Load | 92,300 psi (on 0.022 in. wide Timken test block) |
| Rotational Speed | 800 rpm ± 5 rpm (adjustable up to 850 rpm) |
| Test Duration | 10 min ± 15 s |
| Temperature Control Range | Ambient to 120 °C (digital PID controller with fluid circulation system) |
| Oil Reservoir Capacity | 3 L (heated, pumped, valve-controlled |
| Grease Auto-Feeder Rate | 45 ± 9 g/min |
| Drive Motor | 2 HP, unidirectional, with RPM display |
| Load Application | Static load via 10:1 lever arm |
| Sample Types | Liquid lubricants and greases |
| Compliance | ASTM D2509, ASTM D2782, SH/T 0203 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | FYH-M |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58C |
| Product Type | Portable Instrument |
| Detection Modules | XRF Elemental Analysis |
| Test Time per Sample | <10 minutes |
| Sample Volume Required | 12 mL |
| Compliance | ASTM D6595, D7690, D7883, D445 |
| Interface | Touchscreen with Embedded Diagnostic Software |
| Power | Rechargeable Battery |
| Enclosure | Ruggedized Transport Case Integrating All Four Modules |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Product Type | Portable Instrument |
| Standard Compliance | DIN 51805 |
| Temperature Range | –60 to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Measurement Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based thermoelectric control |
| Sample Handling | Standalone operation, no auxiliary equipment required |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Application Standard | DIN 51805 |
| Temperature Range | –60 °C to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC / 10 A |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based |
| Sample Compatibility | NLGI Grades 000–3 Greases |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Test Principle | Corrosion-Resistant Capillary Extrusion (DIN 51805) |
| Temperature Range | −50 °C to +30 °C |
| Temp. Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC (optional) |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HFN-B |
| Measurement Principle | Capillary Efflux (ASTM D445 / ISO 3104 compliant) |
| Temperature Control | 40 °C ± 0.1 °C |
| Sample Volume | 80 µL |
| Measurement Time | ≤ 30 s per test |
| Viscosity Range | 2–1000 mm²/s (cSt) at 40 °C |
| Calibration | Multi-point viscosity standard calibration (certified mineral oil standards) |
| Display | 7-inch capacitive touchscreen |
| Power | Rechargeable Li-ion battery (≥ 8 h continuous operation) |
| Cleaning | Solvent-free — dry wipe with lint-free industrial cloth |
| Compliance | Designed to support ASTM D445, ISO 3104, and ISO 2909 procedures for kinematic viscosity determination |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BLB701 / BLB702 / BLB DIN |
| Product Type | Laboratory Instrument |
| Test Parameter | Low-Temperature Apparent Viscosity (ASTM D2983, IP 295, GB/T 6538) |
| Compliance | ASTM D2983, IP 295, GB/T 6538 |
| Dimensions (W×D×H) | 48 × 53 × 66 cm |
| Weight | ~68 kg |
| Voltage | 220 VAC, 50/60 Hz, Single Phase |
| Fuse Rating | BLB701: 10 A |
| BLB702 | 2 × 10 A |
| BLB-DIN | 12 A max |
| Cooling Capacity | 600 W at 0 °C, 300 W at −40 °C, 100 W at −70 °C |
| Heating Capacity | 600 W |
| Temperature Range | BLB701: 30 °C to −40 °C |
| BLB702 | 30 °C to −70 °C |
| BLB-DIN | 30 °C to −55 °C |
| Viewing Window | ~41 × 23 cm |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Safety Features | High-pressure cutoff, over-temperature limit, low-fluid-level detection and auto-shutdown |
| Certification | CE |
| Shipping Weight | 122–136 kg |
| Shipping Dimensions | 81 × 76 × 104 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | MRV TP-1 |
| Standards Compliance | ASTM D4684 (Method A), SH/T 0562 |
| Temperature Range (BLB702) | 30 °C to −70 °C |
| Cooling Power | 600 W at 0 °C, 100 W at −40 °C, 300 W at −70 °C |
| Heating Power | 600 W |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Dimensions (W×D×H) | 48 cm × 53 cm × 66 cm |
| Net Weight | ~68 kg |
| Transport Weight | 122–136 kg |
| Transport Dimensions | 81 cm × 76 cm × 104 cm |
| Electrical Supply | 220 VAC, 50/60 Hz, Single Phase |
| Safety Certifications | CE, High-Temp Cut-off, Low-Level Fluid Detection, Over-Pressure Breaker |
| Viewing Window | 41 cm × 23 cm |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KLD-B-2 |
| Pricing | Available Upon Request |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | KLD-O-S |
| Product Type | Online Analyzer |
| Detection Parameters | Particle Contamination & Water Content (Relative Humidity) |
| Compliance Standards | ISO 4406, GJB 420B, NAS 1638 |
| Flow Rate | 50–120 mL/min |
| Power Supply | DC 10–26 V (Ripple < 100 mVp-p) |
| Dimensions | 105 × 89 × 64 mm |
| Weight | 538 g |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −20 to +80 °C |
| Pressure Rating | < 1 MPa |
| Humidity Range (Operating) | 20–85% RH (non-condensing) |
| (Storage) | up to 98% RH |
| Communication Interface | RS-485 / RS-232 |
| Repeatability | ±0.5 ISO Code |
| Moisture Measurement Range | 0–100% RH |
| Temperature Sensing Range | −20 to +80 °C |
| Channel Configuration | 4- or 6-channel, auto-adaptive |
| Display | OLED with wide viewing angle |
| Input Control | Dedicated tactile keys for分级 navigation and parameter configuration |
| Alarm Function | Real-time contamination level alerting based on ISO 4406 thresholds |
| Bubble Discrimination | Patented full-spectrum optical discrimination algorithm for bubble rejection |
| Flow Compensation | Onboard real-time flow rate calculation and viscosity-corrected particle counting |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | FK12190 |
| Sample Capacity | 6 positions |
| Test Temperature Range | Ambient to 127 °C |
| Bath Medium | 9.5 L white mineral oil |
| Temperature Control Accuracy | ±0.5 °C at 110 °C |
| Air Flow Rate | 1.0 ±0.1 L/h (independent flowmeter & control valve) |
| Stirring Motor | 1/20 hp recirculating agitator |
| Compliance | ASTM D2440, D4636, D5968, D6594 |
| Display | Dual-scale digital LED (°C/°F), real-time and setpoint |
| Safety | Over-temperature cut-off with automatic power disconnection |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | FK35100 |
| Sample Capacity | 6 |
| Temperature Range | 51.7–399 °C |
| Temperature Stability | ±0.5 °C (±1 °F) |
| Maximum Air Flow Rate | 10 L/h |
| Power Supply | 220–240 V, 50/60 Hz, Single-Phase, 15.9 A |
| Dimensions | 83 × 37 × 105 cm |
| Weight | 122.9 kg |
| Compliance | ASTM D4636, D5968, D6594 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | FK39199 |
| Temperature Range | Up to 100 °C |
| Bath Capacity | 38.5 L (water) |
| Power Supply | 220–240 V, 50/60 Hz |
| Dimensions | 52.7 × 38.75 × 74.9 cm |
| Construction | Stainless steel wetted parts |
| Standards Compliance | ASTM D2711, DIN 51353, ASTM D1401 (via configuration) |
| Control System | Microprocessor-based LED digital temperature controller with dual independent stirrer speed control and digital RPM display |
| Illumination | Integrated LED lighting with transparent front viewport |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K12239 |
| Temperature Range | Ambient to 200 °C |
| Temperature Stability | ±0.1 °C (±0.2 °F) |
| Bath Medium | Silicone Oil |
| Sample Capacity | Up to 12 glass vessels (10 for ASTM D5968 / FTM 791-5307/5308) |
| Air Flow Control | Optional analog flowmeter or digital mass flow controller |
| Temperature Display | Dual-line LED, °C/°F selectable |
| Power Supply | 220–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 65 × 61 × 107 cm |
| Weight | 96.6 kg |
| Compliance | ASTM D943, D2274, D2440, D2893, D4310, D4636, D5968, D6594 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model Series | K12290, K12219, K12339, K12395 |
| Sample Capacity | 8 / 12 / 30 / 60 positions |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C (±0.2 °F) |
| Bath Volume | 37.8 L (8-pos) / 71.9 L (12-pos) / 227 L (30-pos) / 432 L (60-pos) |
| Bath Medium | White Mineral Oil |
| Compliance | ASTM D943, D2274, D2893, D4310, D6158 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K18650 |
| Standard Compliance | ASTM D5074, STP512A L-60-1 (formerly CRC L-60), FTM 791-2504 |
| Test Temperature | 162.8 ± 0.6 °C |
| Air Flow Rate | 1.1 L/h |
| Drive Speed | 1725 rpm |
| Load | 128 W |
| Power Supply | 220–240 V, 50 Hz, single-phase, 15 A |
| Dimensions (Test Chamber) | 61 × 61 × 37 cm |
| Dimensions (Control Cabinet) | 60 × 60 × 44 cm |
| Weight | 149.7 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K19000 |
| Standard Compliance | ASTM D6184, FTM 791-321 |
| Test Temperature Range | Up to 482°C |
| Sieve Specification | 60-mesh conical wire mesh funnel with metal handle |
| Receptacle | 200 mL covered beaker |
| Net Weight | 0.2 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K26210-3 |
| Standard Compliance | ASTM D6082 |
| Test Temperature | 150 °C |
| Temperature Uniformity | ±0.5 °C |
| Bath Volume | 38.5 L |
| Air Flow Rate | 200 mL/min |
| Power Supply | 220–240 V, 50 Hz |
| Dimensions (W×D×H) | 82 × 38 × 79.4 cm |
| Weight | 28.1 kg |
| Heating System | Immersed copper heater with PID-controlled microprocessor |
| Temperature Display | Dual LED, selectable ℃/°F |
| Construction | Steel base with chemical-resistant polyimide enamel coating |
| Includes | Two 1000 mL calibrated test cylinders, two calibrated antifoam heads, two air inlet tubes, two exhaust tubes, two rubber stoppers, one bath tank, one support stand |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K30165NACE |
| Sample Capacity | 6 positions |
| Bath Volume | 41.6 L |
| Temperature Range | Ambient to 104°C (220°F) |
| Temperature Stability | ±0.5°C (±1°F) |
| Stirring Speed | 1000 rpm |
| Heating Medium | White mineral oil |
| Power Supply | 220–240 V, 50 Hz, 6.8 A, Single-phase |
| Dimensions (W×D×H) | 83 × 36 × 69 cm |
| Weight | 35.8 kg |
| Construction | Stainless steel housing with chemical-resistant polyurethane coating |
| Motor Type | Explosion-proof ball-bearing induction motor, 1/12 hp |
| Control System | Microprocessor-based with °C/°F toggle and digital setpoint display |
| Overtemperature Protection | Integrated safety circuit |
| Compliance | ASTM D665, D6158, D3603, IP 135, ISO 7120, DIN 51585, FTM 791-4011, NFT 60-151 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K38590 |
| Sample Capacity | 10 positions |
| Temperature Range | +80 °C to –40 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Refrigeration Rate | up to 5.0 °C/min |
| Refrigerant | R-507 |
| Compressor Power | 1/3 hp |
| Heating Power | 600 W |
| Power Supply | 220 V, 50/60 Hz, 7 A |
| Dimensions | 39 × 32 × 34 cm |
| Weight | 47.6 kg |
| Construction | Stainless steel housing and durable thermoplastic components |
| Compliance | ASTM D4684, D3829, D6896, D6821*, SAE J300, ILSAC GF-3/GF-4 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K39495 |
| Temperature Range | 25–84 °C |
| Temp. Stability | ±0.05 °C |
| Stirring Speed | 0–2000 rpm |
| Stirring Accuracy | ±1 rpm |
| Simultaneous Test Capacity | 7 × 100 mL samples |
| Bath Medium | Water or white mineral oil |
| Bath Volume | 15.15 L |
| Power Supply | 220–240 V / 50 Hz / 12 A |
| Dimensions (W×D×H) | 52.7 × 38.75 × 74.9 cm |
| Heating Power | 75 W (1/10 hp) |
| Bath Material | Transparent polycarbonate (25.5 × 28 × 24 cm) |
| Standards Compliance | ASTM D1401, D6074, D6158 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | NOACK |
| Standard Compliance | ASTM D5800, DIN 51581 |
| Temperature Range | 150–350 °C (±0.1 °C accuracy) |
| Heating Medium Options | Aluminum block (non-Wood’s alloy) or Wood’s alloy bath |
| Power Supply | 230 V, 50 Hz, 5.8 A |
| Dimensions (K44090) | 59 × 35 × 68 cm |
| Weight (K44090) | 26.7 kg |
| Dimensions (K44091) | 54 × 38 × 37 cm |
| Weight (K44091 with accessories) | 38.2 kg |
| Sample Mass | 65 g |
| Test Duration | 60 min at specified temperature |
| Air Flow Control | Manual (incl. inclined-tube manometer, 0–30 mm H₂O) or optional automated pressure regulation |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K50119 |
| Test Plate Temperature Range | Up to 400 °C |
| Sample Oil Temperature Range | Up to 210 °C |
| Spray Speed | 0–1800 rpm (digital display) |
| Timer Range | 0–99.9 hours (adjustable countdown) |
| Acid Gas Flow Rate | 0.2–1.0 L/h |
| Oil Capacity | 0.35 L |
| Power Supply | 220–240 V, 50/60 Hz, 5 A |
| Test System Dimensions | 81 × 46 × 53 cm, 22.7 kg |
| Control Unit Dimensions | 46 × 30 × 46 cm, 11.3 kg |
| Temperature Display Units | °C or °F selectable |
| Compliance | FTM 791-3462 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K56190 (1 L/h per sample) / K56290 (15 L/h per sample) |
| Sample Capacity | 12 positions |
| Temperature Range | 80–200 °C |
| Control Stability | ±0.2 °C |
| Heating Medium | Aluminum Block |
| Standards Compliance | IP 48, IP 280, IP 306, IP 307, IP 331, IP 335 |
| Display | Dual-line LED, ℃/°F selectable |
| Overheat Protection | Automatic power cutoff above setpoint |
| Air Flow Control | Independent precision mass flow regulation per station |