| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K88501 |
| Standards Compliance | ASTM D3427, IP 313, DIN 51381, NF E48-614 |
| Temperature Range | Ambient to 75 °C |
| Temperature Control | Microprocessor-based LED digital controller |
| Power Supply | 230 V, 50 Hz, 1.5 A |
| Dimensions (W×D×H) | 61 × 71 × 97 cm |
| Weight | 103 kg |
| Sample Volume | Standard 200 mL test vessel |
| Air Flow Control | Regulated compressed air supply with pressure gauge |
| Safety | Overheat protection circuit |
| Optional | Windows-based data acquisition software, heated sample sleeve, baffle kit, air bath circulator with calibrated thermometer and sinker |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K88539 |
| Product Type | Laboratory Instrument |
| Test Parameter | Air Release Time (ART) |
| Standards Compliance | ASTM D3427, IP 313, ISO 9120, DIN 51381, NF E 48-614, NF T 60-149, BS 2000 Part 313 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K95200 |
| Product Type | Laboratory Instrument |
| Test Parameter | Grease Adhesion Force |
| Accuracy | <0.1 N |
| Load System | Electromechanical Control |
| Sample Mass | 5 g |
| Test Duration | ~120 s |
| Result Units | N, N/mm², N/in² |
| Test Speed | 250 mm/s (standard) |
| PLC | Siemens S7-1200 + 7" HMI Touchscreen |
| Interface | Ethernet |
| Temperature Range | Ambient to 80 °C |
| Voltage | 110–230 V AC, 50–60 Hz |
| Dimensions (H×W×D) | 620 × 300 × 320 mm |
| Weight | 30 kg |
| Optional Accessory | K95200-1 Temperature-Controlled Test Chamber |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K95400 |
| Product Type | Laboratory Instrument |
| Test Parameter | Grease Bleedability (Penetrability under Pressure) |
| Operating Temperatures | 0 °F, 30 °F, 75 °F |
| Dimensions | 38 × 15 × 13 cm |
| Weight | 5.4 kg |
| Power Requirement | None |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | KLA-1-TS / KLA-2-TS / KLA-3-TS |
| Temperature Range | +80 °C to –80 °C |
| Resolution | 0.06 °C |
| Accuracy | ±0.1 °C |
| Repeatability | Compliant with or better than ASTM D2500, D97, D5771–D5773, D5853, D5950 |
| Cooling System | Dual-stage thermoelectric (Stage 1: –40 °C |
| Stage 2 | –80 °C) |
| Display | 6.4″ TFT/LCD touchscreen (640 × 480, 262K color) |
| Data Storage | >60,000 test records in Microsoft Excel-compatible format |
| Compliance | ASTM, ISO, DIN, IP standards per model configuration |
| Sample Detection Method | Coaxial fiber-optic pulse photometry (cloud point) |
| Max. Test Heads | 6 |
| Power Supply | 220 V ±15%, 50–60 Hz |
| Dimensions | 66 × 60 × 80 cm |
| Weight | 80 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K18200 Series Oxidation Stability Tester |
| Standards Compliance | ASTM D2112, D2272, D4742 |
| Operating Pressure | 90 psi (620 kPa) initial, up to 500 psi (3450 kPa) burst rating |
| Temperature Range | Ambient to 200 °C |
| Control Stability | ±0.02 °C |
| Rotation Speed | 100 rpm ± 1 rpm |
| Bath Capacity | 68 L (2-cell), 95 L (3-cell), 121 L (4-cell) |
| Heating Power | 0–2750 W (2/3-cell), 0–3750 W (4-cell) |
| Drive Motor | 0.5 hp continuous-duty, spherical bearing, integrated gear reduction |
| Bearing Type | PTFE-coated carbon fluoropolymer |
| Pressure Sensing | Direct-mount transducer on oxygen bomb |
| Safety | Auto-shutdown at >177 °C or >16.7 °C above setpoint |
| Software | Oxidata™ v5.x (Windows-based, FDA 21 CFR Part 11–ready audit trail, GLP-compliant data archiving) |
| Brand | Lawler |
|---|---|
| Origin | USA |
| Model | 64-22 |
| Compliance | ASTM D1478, ASTM D4693 |
| Operating Temperature Range | –73 °C to ambient |
| Temperature Stability | ±0.3 °C |
| Temperature Display Resolution | 0.1 °C |
| Drive Speed | 1 rpm (fixed) |
| Test Stations | 1 or 2 independent |
| Torque Sensing | Strain-gauge-based, digital readout |
| Cooling System | Dual hermetic mechanical compressors |
| Air Bath Seal Integrity | High-efficiency insulated lid with positive closure |
| Optional Feature | Torque-limit safety cutoff (with Option V) |
| Brand | Lawler |
|---|---|
| Origin | USA |
| Model | LB-76-2TG |
| Temperature Range | −60 °C |
| Temperature Stability | ±0.3 °C |
| Sample Capacity | 28 samples per bath |
| Compliance | ASTM D2983-03, ISO 9262, IP 267 |
| Configuration | Floor-standing air-bath viscometry system |
| Dimensions (W×D×H) | 83 × 94 × 117 cm |
| Weight | 500 lbs |
| Brand | Lawler |
|---|---|
| Origin | USA |
| Model | 323 |
| Temperature Range | 24–150 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Test Positions | 4 |
| Air Flow Control | Dual digital mass flow meters (94 ± 5 mL/min and 200 ± 5 mL/min) |
| Compliance | ASTM D892, ASTM D6082, SH/T 0722–2002 |
| Heating Method | Forced-air bath with independent digital sample temperature probes |
| Interface | Touchscreen LCD controller |
| Viewing Window | Large optical-grade front window |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Model | LS-O (Rotating Bomb Oxidation Method) |
| Detection Parameter | Oxidation Stability |
| Temperature Control Points | 140.0 ± 0.1 °C and 150.0 ± 0.1 °C |
| Rotation Speed | 100 ± 5 rpm |
| Pressure Range | 0–1.6 MPa (Pressure Sensor Accuracy: ±0.1% FS |
| Precision Gauge | 0.25 Class) |
| Power Consumption | ≤1400 W |
| Dimensions | 300 × 500 × 500 mm (W × D × H) |
| Weight | 40 kg |
| Compliance Standards | SH/T 0193, ASTM D2272 |
| Interface | Ethernet for LIMS integration |
| Data Storage | Local HDD with persistent multi-test archive |
| Max Concurrent Units per PC | 4 |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | LPC500 + Avio500 |
| Application | Elemental Analysis & Particle Counting in Lubricants |
| Sample Volume | <1 mL per dual analysis |
| Cycle Time | ≤45 seconds per sample |
| Brand | csfriend (Fulande) |
|---|---|
| Origin | Hunan, China |
| Model | FDH-1702 |
| Standard Compliance | SH/T 0059 |
| Sample Mass | 65 g |
| Heating Method | Metal Bath |
| Temperature Control | 250 ± 0.5 °C |
| Timer Accuracy | 3600 s ± 0.1 s |
| Pressure Measurement | 20 mm H₂O ± 0.2 mm H₂O |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Input Power | 1.4 kVA |
| Operating Ambient | 15–35 °C |
| Temperature Controller | Intelligent Programmable PID Controller |
| Heating Time to Setpoint | ~60 min |
| Sensor Type | Pt100 Resistance Thermometer |
| Vacuum System | Integrated Low-Noise Self-Developed Vacuum Module |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MiniLab EL |
| Application | Elemental Analysis of Lubricating Oils |
| Instrument Type | Benchtop/Field-Deployable Laboratory Analyzer |
| Compliance | Designed for ASTM D6595, ASTM D5185, ISO 8217, SAE J183, MIL-STD-3007 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOACK Method |
| Price | Upon Request |
| Brand | atten2 |
|---|---|
| Origin | Spain |
| Model | OilCMS |
| Instrument Type | Online Lubricant Condition Monitor |
| Detection Parameters | Particle Contamination, Water Content (RH%), Oil Degradation State, Viscosity Estimation (up to 3000 cSt) |
| Compliance Standards | ISO 4406, SAE AS4059, NAS 1638 |
| Display | 10-inch capacitive touchscreen |
| Power | Integrated rechargeable lithium battery |
| Data Storage | Local database for up to 500 oil samples with trend aggregation |
| Flow Control | Built-in motorized pump with optional high-pressure adapter (compatible with real-time recirculation systems up to 350 bar) |
| Particle Analysis Method | Digital imaging with bubble suppression and morphological classification |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilMoisture |
| Product Type | Online Instrument |
| Detection Parameter | Water Content |
| Compliance Standard | ASTM D6304 |
| Sensitivity | ppm-level |
| Power Supply | 24 V DC, <100 mA |
| Output Interface | Modbus RTU (RS-485) |
| Max Operating Pressure | 12 bar |
| Operating Temperature Range | 0–80 °C |
| Viscosity Compatibility | up to 680 cSt |
| Housing Material | Aluminum (stainless steel optional) |
| Optical Window | BK7 glass |
| Sealing Material | Fluoroelastomer (FKM) |
| Ingress Protection | IP65 |
| Certification | CE |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | EHD2 |
| Pricing | Upon Request |
| Product Type | Laboratory Instrument |
| Test Parameters | Oil Film Thickness (1–1000 nm), Traction Coefficient (Friction Coefficient) |
| Load Range | 0–50 N |
| Contact Pressure Range | 0–0.7 GPa (Steel Ball–Glass Disk) / 0–3 GPa (WC Ball–Sapphire Disk) |
| Sliding/Rolling Ratio | 0–100% |
| Linear Speed | 0–4 m/s |
| Temperature Range | Ambient to 150 °C |
| Sample Volume | 120 mL |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ETM |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 100–1650 N |
| Maximum Contact Pressure | 3.5 GPa (standard steel test specimens) |
| Sliding Velocity | up to 3.5 m/s |
| Temperature Range | 10–150 °C |
| Sample Volume | 30 mL (10 mL with optional filler insert) |
| Operating System | Windows 10 |
| Safety Features | Dual PT100 RTD temperature monitoring, emergency stop button, interlocked lubricant reservoir lid |
| Power Supply | 100–240 V, 50/60 Hz, 1600 VA |
| Weight (main unit) | 52 kg |
| Dimensions (H × W × D) | 425 mm × 400 mm × 605 mm |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MPR |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 0–2000 N |
| Contact Pressure | 0–3.2 GPa |
| Sliding/Rolling Ratio | 0–200% |
| Temperature Range | Ambient to 150 °C |
| Specimen Volume | 150 mL |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | MTM2 |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Sample Volume | 10–35 mL |
| Load Range | 0–75 N |
| Contact Pressure Range | 0–1.25 GPa (standard test geometry) |
| Sliding/Rolling Velocity | −4 to +4 m·s⁻¹ |
| Temperature Range | Ambient to 150 °C (sub-ambient operation supported via external refrigerated oil bath) |
| Power Supply | 100–240 V AC, 50/60 Hz, 750 VA |
| Host Weight | 30 kg |
| Brand | PULUODY |
|---|---|
| Model | DMA-135 |
| Principle | U-tube Oscillation Method |
| Measurement Range | 0.0000–3.0000 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Sample Volume | 2 mL |
| Measurement Time | ≤60 s |
| Display | 2.4″ Color LCD (320×240) |
| Power | 9 V alkaline battery (≈90 h operation) |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, DB/T 1231–2010, SN/T 2383–2009 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DMA-135D |
| Type | Portable Instrument |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, DB/T 1231–2010, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GREASE-CHECK |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Product Type | Portable Field Analyzer |
| Test Scope | Grease Consistency, Oil Bleed, Contamination Assessment, Color Stability, Shelf-Life Indication |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | P-ICP |
| Product Category | Laboratory Instrument |
| Analytical Method | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Compliant Standards | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Customizable Detection Channels | 1000 channels |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-4929A |
| Heating Power | 0–300 W (continuously adjustable) |
| Stirring Speed | 375 rpm |
| Supply Voltage | AC 220 V, 50 Hz |
| Illumination Lamp | 7 W |
| Oil Bath Capacity (Inner) | 600 mL |
| Compliance | GB/T 4929, ISO 2176, ASTM D566 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-511A |
| Power Supply | 220 V AC, 50 Hz |
| Input Power | 500 W (Heating: 2 × 100 W) |
| Ultimate Vacuum | ≥0.09 MPa |
| Air Extraction Rate | ≥20 L/min |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PS-PM201 |
| Price Range | USD 3,300 – 4,200 (FOB) |
| Instrument Category | Laboratory Analyzer |
| Test Parameter | Foam Tendency & Foam Stability |
| Compliant Standards | GB/T 12579, ASTM D892 |
| Temperature Control Range | Low Bath 24 °C / High Bath 93.5 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | High-Resolution Color Touchscreen |
| Power Consumption | 3300 W |
| Air Flow Rate | 94 ± 5 mL/min per diffuser |
| Diffuser Diameter | Ø25.4 ± 0.02 mm |
| Maximum Pore Size | ≤80 µm |
| Air Permeability at 2.44 kPa (250 mm H₂O) | 3000–6000 mL/min |
| Electrical Supply | AC 220 V ±5%, 50 Hz ±5% |
| Operating Ambient | 10–35 °C, ≤85% RH |
| Net Weight | 39 kg |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | BOR-3000 |
| Load Capacity | Up to 3000 N |
| Rotational Speed Range | 0.1–5000 rpm (0.1 rpm resolution) |
| Temperature Range | Ambient to +200 °C |
| Optional Low-Temp Control | −40 °C to +200 °C |
| Optional High-Temp Control | Ambient to +500 °C |
| Test Standards Compliance | ASTM G77, ASTM D2509, ASTM D2714, ASTM D2782, ASTM D2981, ASTM D3704, SH/T 0203, GB/T 11144 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | BOR-3000 |
| Application | Friction and Wear Testing |
| Compliance | ASTM D3704, D2509, D2782, D2981, G77, G176 |
| Max Load | 10,000 N |
| Max Speed | 5000 rpm |
| Temp Range | Up to 500 °C |
| Torque Measurement | In-line high-resolution |
| Test Modes | Continuous, Reciprocating, Stepped Load, Oscillatory |
| Sample Mounting | Modular block holder for shafts, bearings, seals, rings, thrust/conical rollers |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | FBT-1000 |
| Test Types | EP (Extreme Pressure) and Wear Testing |
| Temperature Range | –40 °C to 200 °C (optional up to 400 °C) |
| Maximum Load | 12,000 N |
| Rotational Speed | Up to 1800 rpm |
| Real-time Monitoring | Torque, Load, Temperature, Acoustic Emission, Friction Coefficient |
| Compliance | ISO 12583, ASTM D2266, D2596, D2783, D4172, DIN 51350, BS EN ISO 20623, CEC L-45-A-99 |
| Sample Compatibility | Lubricating oils, greases, additives, solid lubricants |
| Data Resolution | Sub-micron wear scar measurement via integrated 3D profilometry |