Empowering Scientific Discovery

MappingLab

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMappingLab
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelMVC-801
Instrument TypeSemi-Automatic
Control InterfaceAnalog (0–5 V / 0–10 V) & Digital (TTL/BNC)
Valve Count8 Independent Solenoid Valves
Valve Specifications12 V DC, Max 4 W per valve, Min 24 Ω resistance
Cascade Capability11 Isolated BNC Trigger Inputs/Outputs
Memory FunctionYes (Last Valid Configuration Retained)
Overflow ProtectionIntegrated Flow Monitoring with Audible/Visual Alert
Software CompatibilityNative Integration with pCLAMP (Axon), PatchMaster (HEKA), and Custom LabVIEW/Python Scripts
Regulatory ContextDesigned for GLP-compliant electrophysiology laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMappingLab
ModelVCS-3002
Output ModesConstant Voltage & Constant Current
Voltage Range±90 V
Current Range±32 mA
Voltage Accuracy±0.1 V
Current Accuracy±20 µA
Max Output Frequency30 kHz
Pulse Duration StabilityUp to 200 h continuous operation
IsolationBuilt-in galvanic isolation (no external isolator required)
I/O InterfaceTTL-triggered stimulation, analog/digital I/O connectors
ProtectionIntegrated overcurrent and overvoltage protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMappingLab
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Instrument TypeSingle-Well Format
Application DomainIn Vitro Electrophysiology
Electrode Configurations32-, 64-, 128-, and 256-channel flexible or rigid substrates
Substrate OptionsPolyimide-based flexible arrays (thickness down to 10 µm) and glass-based rigid arrays (50 × 50 × 1 mm base
electrode diameters20/30/50 µm
well inner diameter22 mm)
CompatibilityLangendorff-perfused hearts, open-chest in vivo preparations, tissue slices, monolayer cardiomyocyte cultures
Mechanical IntegrationCompatible with MappingLab multi-axis micromanipulator (universal joint mount), perfusion chambers, Faraday cages, and humidified incubator environments
Regulatory ContextDesigned for GLP-compliant preclinical cardiac electrophysiology studies
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMappingLab
OriginBeijing, China
ModelSG-WH012
Instrument TypeManual
Temperature Control RangeAmbient to 100 °C
Flow Rate Range0.02–380 mL/min
Pump Speed Range0.1–100 rpm (bidirectional adjustable)
Temperature Accuracy±0.5 °C
Water Bath Dimensions390 × 330 × 180 mm
Perfusion Chamber Volume200 mL / 500 mL
Return Reservoir Volume100 mL / 200 mL
Speed Resolution0.1 rpm
Peristaltic Pump Dimensions232 × 142 × 149 mm
Operating Environment0–40 °C, RH < 80%
Ingress Protection RatingIP31
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0