Measurement Instruments
Filter
Showing 361–390 of 1342 results
| Brand | Ametek JOFRA |
|---|---|
| Origin | Denmark |
| Product Type | Reference-Grade Dry-Block Temperature Calibrator |
| Model | RTCt Series |
| Temperature Range | –35 °C to 125 °C (standard block), –35 °C to 660 °C (with optional high-temp block) |
| Display | 7-inch full-color capacitive touchscreen with customizable UI |
| Connectivity | USB, Ethernet, Wi-Fi (IEEE 802.11 b/g/n) |
| Dual Sensor Inputs | Yes (simultaneous dual-channel reference and UUT monitoring) |
| Auto Ramp/Soak Control | Full rate control across all operating modes (ramp, soak, switch, multi-step) |
| Preset Temperatures | Up to 6 user-defined setpoints with nameable calibration profiles |
| Graphical Stability Monitoring | Real-time dual-mode visualization (absolute temperature vs. stability threshold → automatic transition to delta-T relative mode upon stabilization) |
| Multi-Step Switch Calibration | Up to 5 sequential temperature switches per automated sequence |
| Compliance | Designed for ISO/IEC 17025 accredited labs |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-20 |
| Type | Ultra-Micro Balance |
| Maximum Capacity | 22 g |
| Readability | 1 µg (0.001 mg) |
| Repeatability | 0.0025 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Sample Pan | Perforated mesh design |
| Draft Shield | Conductive-coated glass with lateral sliding door |
| Interfaces | RS-232C and USB |
| Data Storage | 200 measurement records + 50 calibration logs |
| Software | WinCT-Balance (A&D certified, GLP/GMP-compliant) |
| Display | High-contrast white-backlit LCD |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-22 |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 22 g |
| Dual Range | 5–20 g |
| Readability | 0.1 µg (10⁻⁷ g) |
| Repeatability | 0.004 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Communication Interfaces | RS-232C and USB |
| Data Storage | 200 measurement records + 50 calibration logs |
| Software | WinCT-Balance (GLP/GMP-compliant reporting) |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-5 |
| Type | Ultra-Micro Balance |
| Capacity | 5.2 g |
| Readability | 0.001 mg (1 µg) |
| Repeatability | ±0.0012 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Weighing Pan | Perforated mesh pan |
| Draft Shield | Conductive-coated glass with lateral sliding door |
| Interfaces | RS-232C and USB |
| Data Storage | 200 weighing records + 50 calibration logs |
| Software | WinCT (A&D proprietary GLP/GMP-compliant data acquisition and reporting suite) |
| Display | Large high-contrast white-backlit LCD |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-10001A |
| Maximum Capacity | 10200 g |
| Readability | 0.1 g |
| Calibration | External |
| Repeatability | 0.1 g |
| Instrument Type | Precision Balance |
| Capacity Range | >5000 g |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-10002A |
| Maximum Capacity | 10200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Capacity Range | >5000 g |
| Accuracy Class | 0.01 g (100 mg) |
| Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Stabilization Time | ≤1.0 s (at 50 g load) |
| Compliance | ISO 9001, JIS B 7721, ASTM E898 |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-1003A |
| Type | Precision Balance |
| Maximum Capacity | 1100 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-2002A |
| Maximum Capacity | 2200 g |
| Readability | 0.01 g |
| Repeatability | ±0.01 g |
| Calibration | External |
| Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready data logging |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-203A |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Balance Type | Precision Top-Loading Balance |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical), ~0.8 s for 5 g load |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-3002A |
| Type | Precision Balance |
| Maximum Capacity | 3200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Weighing Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Stabilization Time | ~1.0 s (at 50 g load) |
| Compliance | ISO 9001, JIS B 7721, ASTM E898 |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-303A |
| Type | Precision Balance |
| Maximum Capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-4002A |
| Maximum Capacity | 4200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Pan Size | 165 × 165 mm |
| Stabilization Time | ≤1.0 s (at 50 g load) |
| Compliance | ISO 9001, ISO/IEC 17025 compatible workflows, GLP/GMP-ready documentation support |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-6001A |
| Maximum Capacity | 6200 g |
| Readability | 0.1 g |
| Calibration | External |
| Repeatability | 0.1 g |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready documentation support |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-6002A |
| Maximum Capacity | 6200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025-ready, GLP/GMP-supportive architecture |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-603A |
| Maximum Capacity | 620 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical), ~0.8 s for 5 g load |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | SJ Series |
| Capacity Range | 1000 g to 30 kg |
| Readability | 0.5 g to 0.02 kg |
| Pan Size | 230 × 190 mm |
| Stabilization Time | <1 s |
| Power Supply | 4 × AA batteries (included) or optional AC adapter |
| Display | Large LCD, digit height 25 mm |
| Calibration | Full digital internal calibration |
| Weighing Units | g, lb, oz, lb-oz |
| Resolution Ratio | 1/2000 to 1/5000 |
| Pan Material | Stainless steel (SJ-HS models) |
| Auto Power-Off | Yes |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | FX-iWP |
| Price Range | USD 1–699 (est.) |
| IP Rating | IP65 |
| Stabilization Time | ≤1 s |
| Readability | 1 mg |
| Display | Large Fluorescent LCD |
| Sensor Type | SHS (Strain-Hybrid Sensor) |
| Power | AC Adapter + Rechargeable Internal Battery |
| Compliance | GLP/GMP/GCP/ISO Data Integrity Support |
| Features | Auto-counting (ACAI), Animal Weighing, Below-Balance Hook, Percent Mode, Statistics, Multiple Units, Overload Protection, Vibration Damping, Digital Calibration, Audible Alert, Tare/Zero Tracking, Auto Power Off (10 min idle) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 4239 |
| Pricing | Upon Request |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DN-4022 |
| Product Category | Orifice-Type Flowmeter |
| Operating Pressure Range | 0.1–0.6 MPa |
| Maximum Dilution Ratio | 1:200 |
| Gas Species Capacity | Up to 17 |
| Gas Path Material | Deactivated Stainless Steel & PTFE |
| Maximum Output Flow | 550 mL/min |
| Accuracy | ±5% FS |
| Display | 5-inch True-Color Touchscreen (480×800) |
| Control Interface | Analog/Digital Signal Remote Control |
| Calibration Standard Sequence Points | 8 |
| Dimensions (W×D×H) | 350 × 300 × 120 mm |
| Operating Temperature | −20 °C to +50 °C |
| Storage Temperature | −40 °C to +70 °C |
| Operating Humidity | 10–90% RH |
| Storage Humidity | 5–90% RH |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AP-400 / AP-450 |
| Input Channels | 1 (Thermocouple) |
| Thermocouple Types Supported | AP-400 — E or K only |
| Measurement Range | E: −200 to +800 °C |
| K | −200 to +1370 °C |
| J | −200 to +1100 °C |
| T | −200 to +400 °C |
| R | 0 to +1760 °C |
| Resolution | 0.1 °C (within specified ranges), auto-switches to 1 °C outside |
| Accuracy | ±(0.05% of reading + 0.2 °C) for E/K/J/T at 0–100 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 ±10 °C |
| Temp. Coefficient | ±0.01% of range per °C outside 25 ±10 °C |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage | −20 to +50 °C, 0–85% RH (non-condensing) |
| Sampling Rate | 2 Hz (no print), down to 1 sample/min (interval modes) |
| Battery Life | Up to 120 hours (1-min interval, no print) |
| Power | 4 × AA alkaline batteries (included) or optional AC adapter (AD-100/115/220-500-HR-R) |
| Display | LCD |
| Printer | Thermal line printer, 2.5 mm character height, 37 mm paper width, 1000 lines per roll |
| Memory Capacity | 100 data records |
| Data Output | Absolute timestamp (HH:MM:SS), sequential numbering, batch print |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Dimensions | ~68 × 201 × 42 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Backup Power | Rechargeable lithium cell (real-time clock only) |
| Accessories Included | Carrying pouch, 4 × AA alkaline batteries, paper holder, user manual, ACAP4 thermal paper (1 roll), calibration report, registration card |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AR-6500H / AR-6501H |
| Measurement Principle | Radiation-based (Infrared) + Contact (Thermocouple) |
| Measurement Modes | Non-contact IR + K-type thermocouple contact |
| Temperature Range (IR) | –50.0 to 500.0 °C (AR-6500H), 0 to 1200 °C (AR-6501H) |
| Temperature Range (Contact) | –50.0 to 500.0 °C (K-type, ≤500 Ω) |
| Resolution | 0.1 °C (–50.0 to 525.0 °C display range), 1 °C (up to 1250 °C) |
| Accuracy (IR, AR-6500H) | ±3 °C (<0 °C), ±2 °C (0–250 °C), ±0.8% of reading +1 digit (250–500 °C) |
| Accuracy (Contact, K-type) | ±(0.05% of reading + 0.1 °C) ±1 digit |
| Emissivity Adjustment Range | 0.10–2.00 (0.01 step) |
| Spectral Response | 8–14 µm |
| Detector | Thermopile |
| Response Time | ≈300 ms |
| Laser Targeting | Integrated Class II red laser (650 nm) |
| Repeatability | ±0.4% of reading +1 digit |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| Temperature Coefficient | ±0.01% / °C of measured range |
| Analog Output | –1 mV/°C (optional, sensor sold separately) |
| Output Accuracy | ±(0.15% FS + 1 mV) at 25 °C ±5 °C |
| Power | Rechargeable Ni-Cd battery |
| Operating Time | >30 hours per full charge (varies with usage) |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage Environment | –20–50 °C, 0–85% RH (non-condensing) |
| Dimensions | As per manufacturer’s mechanical drawing |
| Weight | Approx. 400 g |
| Compliance | IEC 60584-1:2013 (K-type linearization), CE marking, RoHS compliant |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1100E / HD-1100K |
| Measurement Range | E-type: −200 to +800°C |
| K-type | −200 to +1370°C |
| Accuracy | ±(0.05% of reading + 0.2°C) at 0°C (0.1°C resolution range) |
| Resolution | 0.1°C (−104.9 to +504.9°C for both E & K), otherwise 1°C |
| Waterproof Rating | IPX5 |
| Display | Large LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Data Logging | Up to 9999 records, 9 programmable intervals, manual trigger, playback & PC transfer via AMS-100 software |
| Compliance | CE, RoHS |
| Operating Environment | 0–40°C, 0–80% RH (non-condensing) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (incl. batteries) |
| Input | Single-channel thermocouple (E or K type), integrated cold-junction compensation, max input resistance 500 Ω |
| Sampling Rate | ~300 ms |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1150E / HD-1150K |
| Temperature Range (E-type) | −200 to +800 °C |
| Temperature Range (K-type) | −200 to +1370 °C |
| Resolution | 0.1 °C (−104.9 to +504.9 °C), 1 °C elsewhere |
| Accuracy (0.1 °C range, ≥0 °C) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0.1 °C range, <0 °C) | ±0.5 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Battery Life | Up to 300 hours (4 × AA alkaline) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (including batteries) |
| Compliance | CE, RoHS, IEC 60584-1:2013 |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1250E / HD-1250K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Accuracy (0 °C, 0.1 °C resolution) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0 °C, 1 °C resolution) | ±(0.1% of reading + 1 °C) |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C |
| Temperature Coefficient | ±0.01% F.S./°C |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Dimensions | 76 × 167 × 36 mm (W × H × D) |
| Weight | ~350 g (incl. batteries) |
| Compliance | CE, RoHS |
| Input | Single-channel thermocouple (E or K type), ANP connector |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Sampling Rate | ~300 ms |
| Data Logging | Up to 9999 records, programmable interval (9 options), manual trigger, peak/valley hold, playback, PC transfer via AMS-100 software |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1350E / HD-1350K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Resolution | 1 °C or 0.1 °C (auto-switching) |
| Accuracy (0.1 °C mode) | ±(0.05% of reading + 0.2 °C) from 0 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C ±10 °C |
| Sampling Rate | ~300 ms |
| Input | Single-channel thermocouple (E or K standard |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) or optional AC adapter |
| IP Rating | Waterproof housing (IEC 60529 IP54 equivalent) |
| Compliance | CE, RoHS |
| Dimensions | 76 × 167 × 36 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Brand | Anritsu |
|---|---|
| Origin | Japan |
| Model | MS2840A-041 |
| Frequency Range | 9 kHz to 6 GHz |
| Phase Noise (1 GHz, 1 kHz offset) | –117 dBc/Hz (nom.) |
| DANL (1 GHz, Preamp OFF) | –153 dBm/Hz |
| RBW | 1 Hz to 31.25 MHz |
| Analysis Bandwidth | Up to 125 MHz (with options) |
| Input Impedance | 50 Ω (N-type female) |
| Operating Temperature | 0°C to +50°C |
| Weight | ≤14.5 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Anritsu |
|---|---|
| Origin | Japan |
| Model | Rubidium™ MG362x1A |
| Frequency Range | 9 kHz – 70 GHz (extendable to 72 GHz) |
| Phase Noise Options | Standard / Low-Noise (Option 3) / Ultra-Low-Noise (Option 13) |
| Output Power | Up to +30 dBm (standard), +16 dBm @ 43.5 GHz, +6 dBm @ 70 GHz |
| Modulation Types | AM, FM, PM, Pulse, Arbitrary Waveform |
| Rack Height | 3U |
| Interface Standards | GPIB (IEEE-488), LAN (10/100/1000BASE-T), USB 2.0 (Type A/B), SDIO, Auxiliary I/O (25-pin & 15-pin), Rear-panel RF Output (K(m)-type, Option 9) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | L-Cor Series |
| Liquid Mass Flow Accuracy | ±0.1% or ±0.2% (depending on model and operating conditions) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Precision Resistance Thermometer |
| Model | MKT 50 |
| Temperature Range | −260 °C to +962 °C (−436 °F to +1764 °F) |
| Resistance Range | approx. 0 Ω to 440 Ω |
| Temperature Accuracy | ±0.0001 °C (±0.1 mK) for Pt100 |
| Resistance Accuracy | < 0.4 mΩ |
| Resolution | 40 μΩ (0.1 ppm full scale) |
| Operating Ambient Temperature | 0 °C to 35 °C (32 °F to 95 °F) |
| Display | Graphic LCD with LED backlight, 128×64 dots (≈65 mm × 35 mm) |
| Power Supply | 2 × AA batteries (1.2–1.5 V) or AC adapter: 100–240 VAC, 50/60 Hz, output 7.5 VDC, 5.34 A, max 40 W |
| Dimensions | 240 mm × 190 mm × 110 mm |
| Weight | 2 kg |
| Brand | Anyty |
|---|---|
| Model | 3R-AID-S |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Pricing | Available upon Request |