Microbiology Detection Instruments
Filter
Showing 31–60 of 106 results
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Sample Type | Petri Dishes |
| Sample Diameter Compatibility | 90–110 mm |
| Counting Accuracy | ≤ ±10% |
| Imaging Resolution | 1920 × 1080 (16 MP Color Camera) |
| Key Features | Dual UV Illumination (254 nm & 366 nm), Adjustable Top/Bottom LED Lighting, Touchscreen Interface (15.6″, Full HD), Onboard Windows 10 OS (64-bit, 256 GB SSD), Real-time Image Correction Tools, Multi-Mode Auto-Count Algorithms, Audit-Trail Enabled Data Management |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | IN/J500 |
| Price | USD 11,400 (FOB) |
| Imaging Sensor | 25 MP color CMOS |
| Lens | 12 mm f/1.4 high-resolution macro lens |
| Minimum Detectable Colony Diameter | 0.05 mm |
| Counting Accuracy | ≥98% (per ISO 4833-1:2013 validation protocols) |
| Counting Speed | ≤2 sec per standard 90 mm Petri dish (1200 CFU/s equivalent throughput) |
| Compatible Dish Types | Pour plate, spread plate, membrane filtration, 3M Petrifilm™, Compact Dry™, RIDA™ filters |
| Dish Diameter Range | 90–110 mm |
| Illumination | Dual independent LED sources (top/bottom) |
| Software Control | Real-time brightness adjustment (1–100%, 1% increments), illumination mode switching (top-only / bottom-only / dual), preset illumination profile storage & recall |
| Calibration | Pixel-to-mm auto/manual calibration with traceable reference standard |
| Compliance | Supports audit trails per FDA 21 CFR Part 11, GLP/GMP data integrity requirements, ISO/IEC 17025 documentation standards |
| Brand | CSY (Shenzhen Csys Instrument Manufacturing Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Instrument Type | Semi-Automatic Microbial Pathogen Detection System |
| Detection Throughput | 16-well |
| Sample Types | Solid, Liquid, Surface Swabs |
| Detection Mode | Qualitative and Semi-Quantitative |
| Display | 7-inch Capacitive Touchscreen |
| OS | Android 9.0 (2 GB RAM + 16 GB ROM, expandable to 128 GB via microSD) |
| Connectivity | 4G LTE (universal band), Wi-Fi 802.11 b/g/n, Ethernet, RS232, Dual USB (A & B), GPS Module |
| Data Export | USB export in TXT or Excel (.xlsx) format |
| Reporting | Built-in thermal label printer |
| Data Management | Cloud-ready architecture with platform interoperability (HTTP/HTTPS API compliant) |
| Regulatory Alignment | Designed to support GLP-compliant workflows and aligns with analytical requirements of GB 29921–2013, ISO 6579-1:2017, and AOAC Official Method 2012.06 for Salmonella detection in food matrices |
| Brand | D.C. Labware |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Autopet-CP8 |
| Instrument Type | Multi-needle Colony Picking Workstation |
| Compatible Microorganisms | *Escherichia coli*, *Saccharomyces cerevisiae*, pathogenic bacteria, anaerobes, phage plaques, microalgae, etc. |
| Inoculation Mode | Solid-to-Liquid Transfer |
| Picking Throughput | 800–1,000 colonies/hour |
| Picking Accuracy | >99% |
| Positioning Precision | ≤0.2 mm |
| Destination Plate Formats | Standard or deep-well SBS-compliant plates (48-, 96-, and 384-well) |
| Source Plate Formats | Petri dishes (8/9/10 cm diameter) or square SBS-format dishes |
| Dimensions (L×W×H) | 87 × 62 × 74 cm |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OxyM-313Pro |
| Price Range | USD 22,500 – 56,000 (based on configuration) |
| Gas Environment Modes | Anaerobic, Microaerophilic, Gradient Oxygen |
| Operation Method | Gloved or Sleeveless Entry (optional integrated long-sleeve system) |
| Gas Supply Requirements | N₂, CO₂, H₂ (for anaerobic mode), compressed air (for microaerophilic/gradient modes) |
| Chamber Volume | 313 L |
| Transfer Lock Volume | 6 L (right-side mounted) |
| Operating Chamber Dimensions (W×D×H) | 890 × 600 × 588 mm |
| Temperature Range | RT + 3°C to 52°C |
| Temperature Uniformity | ±0.3°C |
| Temperature Control Resolution | 0.1°C |
| Humidity Control Range | 20–90% RH |
| O₂ Sensing Range | 0–100% (with optional 0–1000 ppm high-sensitivity sensor) |
| O₂ Control Accuracy | ±0.1% (full scale) |
| CO₂ Control Range | 0–20% |
| Catalyst Lifetime | >3 years (no pre-activation required) |
| De-toxification System | Integrated H₂S and volatile fatty acid scavenger |
| Data Logging Duration | 45 days (exportable via USB) |
| Validation Interface | Standard 4–20 mA / RS485 port for third-party probe integration |
| Safety Features | Dual-door interlock, pneumatic gasket sealing, low-pressure & leak-overrun alarms, HEPA filtration (ISO Class 5 equivalent), 254 nm UV sterilization |
| Brand | DAWEI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DW-16 |
| Price Range | USD 1,400 – 7,000 |
| Compatible Petri Dish Diameter | 90 mm (standard, with base OD 87 mm, lid OD 89–90 mm) |
| Drive Mechanism | Motorized rotary platform |
| Speed Control | 4-step adjustable (200–350 rpm) |
| Construction Material | Corrosion-resistant metal alloy housing |
| Liquid Containment | Integrated spill-resistant sealing design |
| Sterilization Compatibility | Ethanol wipe, 70% isopropanol, and UV irradiation (254 nm) |
| Accessories Included | 1 × instrument host, 1 × dish alignment ring, 1 × power cord |
| Optional Consumables | Stainless steel or disposable sterile spreaders (user-supplied) |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Elite Sealer-1 |
| Detection Method | Culture-based Enzyme Substrate Method |
| Instrument Type | Semi-Automatic |
| Target Analytes | Total Coliforms, *Escherichia coli*, Thermotolerant Coliforms (Fecal Coliforms) |
| Sample Types | Drinking Water, Surface Water, Wastewater |
| Sealing Capacity | <14 sec per 51-well or 97-well Quanti-Tray®-style tray |
| Operating Noise | <48 dB(A) |
| External Casing Temperature | <40°C |
| Preheat Time | ~4 minutes |
| Service Life | >50,000 sealing cycles |
| Compliance Standards | GB/T 5750, HJ 1001 |
| Brand | LIVOBOT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EosBot® Clone-I |
| Instrument Type | Single-Needle Colony Picking Workstation |
| Compatible Microorganism | Escherichia coli |
| Inoculation Modes | Solid-to-Liquid, Liquid-to-Solid |
| Picking Speed | ≥320 colonies/hour |
| Picking Accuracy | 98% |
| Target Plate Formats | Disposable tips |
| Dimensions (D×W×H) | 632 mm × 490 mm × 550 mm |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJL-200 |
| Instrument Type | Fully Automated Colony Counter |
| Petri Dish Compatibility | ≤150 mm diameter |
| Counting Speed | <1 second for ≤500 colonies |
| Colony Size Detection Range | 0.08–100 mm |
| Counting Modes | Fully Automatic, Manual, Spiral Plate Mode |
| Image Resolution | 1080×720 to 2160×1440 pixels |
| Custom Dilution Series Support | Yes |
| Illumination | Dual-mode cold LED source (top and bottom transillumination) |
| Operating Environment | 10–40 °C, ≤80% RH |
| Reporting | Exportable electronic reports (PDF, CSV, Excel), printable hardcopy |
| Software Interface | LIS-compatible (HL7, ASTM E1384 compliant) |
| Hardware Interface | USB 2.0 |
| Brand | FOREVERGEN |
|---|---|
| Model | OE |
| Instrument Type | Fully Automated |
| Detection Method | Visible Light Absorption Spectroscopy |
| Measured Gases | CO₂, O₂ |
| Accuracy | ≤ ±1–2% of Full Scale |
| Dimensions (W×D×H) | 430 × 350 × 120 mm |
| Brand | FUELSTAT |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FUELSTAT® One |
| Detection Throughput | 1 sample per test |
| Brand | FUELSTAT |
|---|---|
| Origin | United Kingdom |
| Model | FUELSTAT® resinae PLUS |
| Instrument Type | Field-Deployable Rapid Microbial Detection Kit |
| Detection Targets | Hormoconis resinae (H. res), bacteria, fungi, and metabolically active yeasts |
| Reporting Format | Mass-based quantification (µg/mL of microbial biomass) |
| Compliance | ASTM D8070, IATA Guidance, JIG Online Approved, referenced in OEM AMMs |
| Time-to-Result | ≤10 min assay time, ≤15 min full report generation |
| Sample Volume | 4 drops (≈200 µL) of fuel |
| Software Integration | iOS/Android mobile application with encrypted data logging and cloud sync |
| Regulatory Context | Supports GLP-aligned field testing |
| Brand | AMAE (Shenzhen Guoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Fully Automated |
| Detection Target | Dispersed/Field-Based Bacterial Pathogens |
| Sample Type | Swab, Environmental Water, Food Homogenate, or Clinical Specimen (pre-extracted nucleic acid) |
| Detection Time | ≤25 min |
| Throughput | 6 samples per run |
| Dimensions | Compact and Field-Portable (≤300 × 220 × 180 mm) |
| Detection Principle | Isothermal LAMP Amplification Coupled with PSFN Nanoparticle-Based Visual & Optical Aggregation Readout |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HDP-150 |
| Power Consumption | 350 W |
| Dimensions (L×W×H) | 470 × 340 × 688 mm |
| Petri Dish Diameter Compatibility | 90 mm |
| Dispensing Throughput | 360 dishes/h |
| Dispensing Accuracy | ±1% |
| Price Range | USD 28,000 – 42,500 |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | HM-FKJ |
| Instrument Type | Benchtop |
| Sample Types | Drinking water, raw water, bottled water, reclaimed water, secondary supply water, distribution system water, wastewater, food processing water, livestock water, medical water |
| Detection Range | 1–2419.6 MPN/100 mL |
| Detection Speed | 24-hour incubation |
| Detection Accuracy | High reproducibility per ISO 9308-1 and EPA 1604 equivalents |
| Weight | 14.2 kg |
| Dimensions (L×W×H) | 42 × 41 × 33 cm |
| Preheating Time | ≤3 min |
| Noise Level | <48 dB(A) |
| External Housing Temperature | <40 °C |
| Sealing Time | ≤12 s per 51-well or 97-well Quanti-Tray®-compatible plate |
| Operating Voltage | AC 220 V ±10%, 50 Hz |
| Ambient Operating Temperature | −10 °C to 50 °C |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HMI-60 |
| Pricing | Upon Request |
| Inoculation Time | 9 or 13 s |
| Weight | 12 kg |
| Power Consumption | 120 W |
| Dimensions (L×W×H) | 335 × 250 × 415 mm |
| Inoculum Volume | 5 µL (24-position mode), 1 µL (60- and 96-position modes) |
| Petri Dish Compatibility | 90 mm diameter |
| Input Voltage | 220 V AC |
| Inoculation Pin Diameter | 3.0 mm (24-pin configuration), 1.6 mm (60-/96-pin configurations) |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HD-AN400 |
| Gas Environment | Microaerophilic (6% O₂) and Programmable O₂ (0.2–18%) |
| Operation Mode | Glove-Free Manual Access |
| Gas Supply | Standard Premixed Gases (e.g., 5% CO₂ / 10% H₂ / 85% N₂ or custom blends) |
| Chamber Capacity | Multi-Size Anaerobic Jars (7+ Configurations Available) |
| Temperature Range | 0–40 °C |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HD-AO10 |
| Pricing | Upon Request |
| Measurement Principle | Fluorescence Quenching (Non-Consumptive, Optical) |
| Oxygen Range | 0–25% O₂ (v/v) |
| Accuracy | ≤ ±2% FS |
| Temperature & Humidity Sensing | Integrated |
| Channel Scalability | Multi-channel expandable (up to 5 concurrent sensor inputs) |
| Power | Rechargeable Li-ion battery |
| Sensor Lifetime | ≥2 years (typical operational service life) |
| Display | ≥4-inch capacitive touchscreen |
| Processor | Dual-core architecture (ARM Cortex-M3 + high-speed FPGA) |
| Data Storage | Internal flash + microSD card (user-replaceable) |
| Communication | Modbus RTU over RS-485 |
| Calibration | Automatic on-power-up oxygen zero/span calibration support |
| Alarm Function | User-configurable high/low O₂ thresholds with timestamped event logging |
| Data Visualization | Real-time trend curves (O₂%, temperature, humidity) with exportable CSV format |
| Compliance | Designed for GLP-compliant laboratory workflows |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-ST20 |
| Price | Upon Request |
| Center Zone Temperature | 925 °C ±25 °C |
| Heating Zone Outer Diameter | φ15 mm |
| Heating Zone Length | 150 mm |
| Warm-up Time | ≤15 min |
| Standby Mode | Adjustable保温 setting for energy-efficient standby |
| Fuse Rating | 250 V, 3 A, 5×20 mm |
| Input Power | AC 220 V, 50–60 Hz, 150 W |
| Dimensions (W×D×H) | ≤120×155×180 mm |
| Standard Configuration | 1 × sterilizer main unit |
| Brand | Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Smartcounter-4K |
| Instrument Type | Fully Automated Colony Counter |
| Minimum Detectable Colony Size | 0.2 mm |
| Camera Resolution | 8.29 MP |
| Maximum Petri Dish Diameter | <150 mm |
| Power Supply | AC 100–240 V, 50 Hz |
| Dimensions (W×D×H) | 290 × 260 × 380 mm |
| Software Language | English & Chinese |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CHQC-20 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Detection Range | Adjustable |
| Detection Time | 24 h |
| Throughput | Configurable |
| Sampling Frequency | Configurable |
| Brand | IDEXX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | WQT2K |
| Detection Principle | Culture-Based Enzyme Substrate Method (DST) |
| Sample Types | Total Coliforms, Escherichia coli, Fecal Coliforms, Enterococci, Pseudomonas aeruginosa, Heterotrophic Plate Count (HPC) |
| Applicable Matrices | Drinking water, non-potable water, surface water, groundwater, medical wastewater, sewage, source water |
| Detection Time | 18–24 h |
| Quantification Range | 1–2,419 MPN/100 mL |
| Compliance | GB 5750.12–2006, ISO 9308-2:2012, US EPA Approved Method |
| Compatible Instrument | IDEXX Quanti-Tray Sealer (Model 2009D) |
| Packaging | Sterile, single-use, batch-certified with lot number and expiry date |
| Brand | IDEXX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WQT2KC |
| Price Range | USD 7–145 |
| Sample Types | Total Coliforms, Fecal Coliforms, Escherichia coli |
| Detection Volume | 100 mL |
| Incubation Time | 24 h |
| Regulatory Compliance | HJ 1001–2018, GB/T 5750.12–2023, US EPA Method 1603, Standard Methods 9223B, ISO 9308-2:2012 |
| Storage | Dark, light-protected, 12-month shelf life at ≤25 °C |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpira Dilutel® |
| Syringe Capacity | 1000 µL |
| Preset Inoculation Volumes | 50 µL, 100 µL, 200 µL |
| Counting Range | 30–1×10¹² CFU/mL |
| Cycle Time (1 aspiration + 1 disinfection + 1 plating) | 25 s |
| Cycle Time (1 disinfection + 5 dilutions + 1 plating at one dilution factor) | 134 s |
| Cycle Time (1 disinfection + 5 dilutions + 1 plating per dilution factor) | 234 s |
| Needle Pressure | up to 8 bar |
| Automatic Disinfection Cycles | 1000 cycles (using 2 L bottle) |
| Automatic Dilution Cycles | 63 cycles (using 2 L bottle) |
| Compatible Diluents | Saline, Ringer’s solution |
| Max. Petri Dishes per Sample (50 µL) | 20 |
| Spiral Plating Mode | Optional (Ø90 mm & Ø150 mm dishes) |
| Loop Plating Mode | Optional (3 dilutions on Ø90 mm |
| Uniform Plating Mode | Optional (Ø55 mm, Ø90 mm, Ø150 mm) |
| Pour Plate Mode | Optional (Ø55 mm, Ø90 mm, Ø150 mm) |
| Editable Inoculation Volume via USB | 10–1000 µL |
| Traceability | Excel™ export, LIMS integration, DataLink™ compatibility |
| Sterilizable Components | Two autoclavable bottles (diluent & disinfectant) + connectors |
| Cross-Contamination Prevention | Overflow cleaning technology |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro |
| Compliance | AFNOR V08-100, ISO 7218, SN/T 2098–2008 |
| Sample Volume Range | 10–1000 µL (programmable via USB) |
| Plating Time | ≤25 s per plate (including wash, aspirate, and spiral deposition) |
| Detection Range | 30–1.1 × 10⁷ CFU/mL |
| Sterilization | Autoclavable components (GL45 bottle adapters, needle assembly, base plate) |
| Cleaning System | Overflow-based internal/external needle rinse with real-time fluid-level sensing |
| Connectivity | USB interface for method programming, audit trail export, and GLP-compliant data logging |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro Milk |
| Syringe Capacity | 1000 µL |
| Preset Volumes | 50 µL, 100 µL, 200 µL |
| Adjustable Volume Range | 10–1000 µL via USB |
| Sample Input Format | Tube (80 × 35 mm) |
| CFU Counting Range | 10²–10⁷ CFU/mL |
| Cycle Time (aspiration + disinfection + plating) | 25 s |
| Needle Pressure | up to 8 bar |
| Auto-Disinfection Cycles per 2 L Bottle | 1000 |
| Auto-Rinse Cycles per 2 L Bottle | 600 |
| Max. Plates per Sample | 20 (at 50 µL) |
| Compatible Petri Dish Diameters | Ø90 mm and Ø150 mm |
| Plating Modes | Spiral (logarithmic), Pour, Loop (circular), Uniform |
| Compliance | ISO 7218, ISO 4833-2, FDA BAM, AOAC 977.27 |
| Voltage/Frequency | 100–240 V~, 50–60 Hz |
| Fuse | T1.6A L 250V, 5 × 20 mm |
| Power Consumption | 45 W |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro® |
| Dispensing Volume | 1000 µL |
| Preset Volumes | 50, 100, or 200 µL |
| Counting Range | 100–1×10⁷ CFU/mL |
| Cycle Time | 25 s |
| Overflow Pressure | 8 bar |
| Disinfectant Capacity (Standard Mode) | 600 cycles (2 L bottle) |
| Same-Sample Sequential Plating | up to 50 Petri dishes (50 µL each) |
| Automatic Disinfection Protocol | Compatible with 90 mm and 150 mm Petri dishes |
| Spiral Modes | Exponential, Circular, Uniform |
| Data Export | Excel™ format |
| Programmable Volume Range | 10–1000 mL |
| Dimensions | 38 × 42 × 29 cm |
| Weight | 15.6 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral® |
| Dispensing Volume | 1000 µL |
| Preset Volumes | 50 µL or 100 µL |
| Counting Range | 300–1.3 × 10⁵ CFU/mL |
| Cycle Time | 25 s |
| Overflow Pressure | 8 bar |
| Disinfectant Capacity (Standard Mode) | 600 cycles per 2 L bottle |
| Same-Sample Continuous Plating | up to 20 Petri Dishes (50 µL each) |
| Auto-Disinfection Protocol | Yes |
| Compatible Dish Diameter | 90 mm |
| Inoculation Pattern | Exponential Spiral & Circular Spiral |
| Dimensions | 38 × 42 × 29 cm |
| Weight | 15.6 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Compliance | AFNOR V08-100, ISO 7218 |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | Scan 1200 |
| Camera | 1.2 MP HD CCD with 28× zoom lens |
| Illumination | Automated dark-field system (6 configurable top/bottom, white/black combinations) |
| Petri Dish Compatibility | Ø 55–90 mm |
| Minimum Detectable Colony Diameter | 0.05 mm |
| Counting Speed | Up to 1000 colonies/sec |
| Zone Measurement Accuracy | ±0.3 mm |
| Resolution | ±0.1 mm |
| Antibiotic Disc Capacity | Up to 7 per 90 mm plate |
| Analysis Standards | CLSI, EUCAST, CA-SFM (Human & Veterinary), Custom Criteria |
| Software Languages | English, French, German, Spanish, Japanese, Chinese, Russian |
| Compliance | 21 CFR Part 11, ISO 7218, AOAC 977.27 |
| Data Export Formats | CSV, Excel™, PDF, JPEG, PNG, BMP, SCA, BIO |
| Power | 100–240 V~, 50–60 Hz, 20 W |
| Dimensions (W×D×H) | 28.8 × 26.3 × 37.3 cm |
| Weight | 9.4 kg |
| Warranty | 3 years (registration required) |
| Spare Parts Availability | 10 years |
| Software Updates | 3 years (excludes validation) |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | Scan 300 |
| Camera | 1 MP CMOS color sensor with M12 lens (28× zoom) |
| Illumination | Automatic dark-field system with 6 configurable combinations (top/bottom, white/black background) |
| Petri Dish Compatibility | Ø 55–90 mm |
| Minimum Detectable Colony Diameter | 0.1 mm |
| Counting Speed | Up to 1000 colonies/sec |
| Counting Accuracy | ≥98% |
| Software Languages | English, French, German, Spanish, Japanese, Chinese, Russian |
| Compliance | ISO 7218, AOAC 977.27, FDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access), GLP/GMP-aligned |
| Data Export Formats | CSV, Excel™, PDF, JPEG, PNG, BMP, SCA, BIO |
| Interface | USB 2.0 |
| Resolution Support | ≥1280 × 1024 px |
| Power Supply | 100–240 V~, 50–60 Hz, 20 W max |
| Dimensions (W×D×H) | 28.7 × 27.1 × 28.9 cm |
| Net Weight | 8.42 kg |
| Warranty | 3 years (registration required) |
| Spare Parts Availability | 10 years |
| Software Updates | 3 years (excluding validation support) |