Microbiology Detection Instruments
Filter
Showing 61–90 of 225 results
| Brand | GENE SCIENCE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Quickprepare |
| Price Range | USD 14,000 – 28,000 |
| Brand | Funke Gerber |
|---|---|
| Origin | Germany |
| Instrument Type | Semi-Automatic Colony Counter |
| Counting Speed | 150–800 colonies/sec |
| Display | 5-digit LCD (0–99,999) |
| Illumination Area Diameter | Adjustable up to 145 mm |
| Counting Surface | Dual-color (black/white) background |
| Compatible Petri Dish Diameter | 50–150 mm |
| Magnification | 2× electronic zoom |
| Dimensions (L×W×H) | 250 × 230 × 95 mm |
| Weight | 1.5 kg |
| Counting Resolution | 0.1 cm² |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | ColonyStar |
| Instrument Type | Fully Automated Colony Counter |
| Magnification | 2× |
| Display | 5-digit LCD (0–99999) |
| Counting Area Diameter | 145 mm |
| Resolution | 0.1 cm² |
| Dimensions (L×W×H) | 250 mm × 230 mm × 95 mm |
| Weight | 1.5 kg |
| Base Options | Black or White Contrast Background |
| Counting Speed | Adaptive to colony density (typical range: 1–5 s per Petri dish under standard conditions) |
| [Brand | Royal Biotech GmbH |
|---|---|
| Origin | Germany |
| Model | RVLM |
| Compliance | ISO 16140:2003 validated |
| Sample Volume | 0.1–1.0 g or mL |
| Throughput | 8 independent channels |
| Detection Principle | Integrated enzymatic (β-glucuronidase), immunological (antigen capture), and microbial growth-based colorimetric assay |
| Sensitivity | ≥1 CFU (theoretical limit) |
| Specificity | ≥99.999% (theoretical limit) |
| Incubation Temperature Range | 30–44 °C (microbe-specific) |
| Readout Method | Optical colorimetric kinetics (qualitative/semi-quantitative visual |
| Software Compatibility | Windows XP/Vista/7 |
| Power Supply | AC adapter + replaceable laptop-grade Li-ion battery] |
| Brand | AMAE (Shenzhen Guoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Fully Automated |
| Detection Target | Dispersed/Field-Based Bacterial Pathogens |
| Sample Type | Swab, Environmental Water, Food Homogenate, or Clinical Specimen (pre-extracted nucleic acid) |
| Detection Time | ≤25 min |
| Throughput | 6 samples per run |
| Dimensions | Compact and Field-Portable (≤300 × 220 × 180 mm) |
| Detection Principle | Isothermal LAMP Amplification Coupled with PSFN Nanoparticle-Based Visual & Optical Aggregation Readout |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HCC-90A |
| Price | USD 4,150 (approx.) |
| Instrument Type | Fully Automated Digital Colony Counter |
| Counting Speed | 0.5 seconds per Petri dish |
| Imaging Sensor | High-Resolution CMOS Camera |
| Output Format | Excel (.xlsx) with Audit-Trail Metadata |
| Batch Processing Capacity | Up to 300 Petri dishes per hour |
| Colony Segmentation | Auto-split for clustered/overlapping colonies |
| Background Subtraction | Adaptive algorithm |
| Area Threshold Filtering | User-defined minimum/maximum colony size (µm²) |
| Image Zoom | Real-time digital zoom (2×–8×) |
| Compatibility | Standard 90 mm and 150 mm Petri dishes |
| Compliance | Designed in accordance with ISO 4833-1:2013, ISO 7218:2017, and USP <61> microbiological enumeration guidelines |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Semi-Automatic Colony Counter |
| Model | HCC-02 |
| Counting Method | Pressure-Sensitive Touch Probe |
| Visual Field Options | Adjustable Bright/Dark Field Background |
| Optical Magnification (Optional) | 3× or 6× |
| Illumination | Adjustable LED Light Source |
| Audio Feedback | Configurable Beep per Count |
| Pressure Sensitivity | Adjustable |
| Reset Function | Built-in Zero Reset |
| Data Interface | USB Connection for PC Communication |
| Optional Accessory | Multi-Color Smart Remote-Controlled Backlight System |
| Compliance | Designed for ISO 4833-1:2013, ASTM D5769, USP <61>, and GLP-compliant microbiological enumeration workflows |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Counting Speed | < 0.5 s per image |
| Data Export Format | Excel (.xlsx) |
| User Interface | Touchscreen-Controlled Software Platform |
| Compliance | Designed for ISO 4833-1:2013, ISO 7218, FDA Bacteriological Analytical Manual (BAM), and USP <61>/<62> microbiological testing workflows |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Counting Speed | < 0.5 s per image |
| Data Export Format | Excel (.xlsx) |
| User Interface | Touchscreen GUI with integrated software |
| Compliance | Designed for ISO 4833-1:2013, ISO 6887-1:2017, and USP <61> microbiological testing workflows |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HDP-150 |
| Power Consumption | 350 W |
| Dimensions (L×W×H) | 470 × 340 × 688 mm |
| Petri Dish Diameter Compatibility | 90 mm |
| Dispensing Throughput | 360 dishes/h |
| Dispensing Accuracy | ±1% |
| Price Range | USD 28,000 – 42,500 |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HMI-60 & HMI-24 |
| Inoculation Method | Liquid-based capillary transfer |
| Instrument Type | Fully Automated |
| Cycle Time | 9–12 s per plate |
| Dimensions (W×D×H) | 335 × 250 × 415 mm |
| Power Supply | 220 V AC |
| Power Consumption | 120 W |
| Weight | 12 kg |
| Inoculum Volume | 5 µL (HMI-24) / 1 µL (HMI-60) |
| Compatible Petri Dish Diameter | 90 mm |
| Control Interface | Touchscreen with real-time animation |
| Positioning System | Motorized rotary sample stage with auto-alignment |
| Actuation | Footswitch-enabled start/pause |
| Reset Function | Hardware-initiated system reinitialization |
| Regulatory Status | Chinese National Patent Certified |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | HM-FKJ |
| Instrument Type | Benchtop |
| Sample Types | Drinking water, raw water, bottled water, reclaimed water, secondary supply water, distribution system water, wastewater, food processing water, livestock water, medical water |
| Detection Range | 1–2419.6 MPN/100 mL |
| Detection Speed | 24-hour incubation |
| Detection Accuracy | High reproducibility per ISO 9308-1 and EPA 1604 equivalents |
| Weight | 14.2 kg |
| Dimensions (L×W×H) | 42 × 41 × 33 cm |
| Preheating Time | ≤3 min |
| Noise Level | <48 dB(A) |
| External Housing Temperature | <40 °C |
| Sealing Time | ≤12 s per 51-well or 97-well Quanti-Tray®-compatible plate |
| Operating Voltage | AC 220 V ±10%, 50 Hz |
| Ambient Operating Temperature | −10 °C to 50 °C |
| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MT-303 |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Semi-Automatic Membrane Filtration System |
| Detection Throughput | Up to 3 samples simultaneously |
| Filter Cup Capacity | 100 mL |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 30 W |
| Pump Flow Rate | ≥300 mL/min |
| Ultimate Vacuum | 60 kPa |
| Filtration Configuration | Triple-Head Stainless Steel Manifold |
| Dimensions (L×W×H) | 28 × 18 × 14 cm |
| Construction Material | AISI 304 Stainless Steel |
| Surface Finish | Electropolished Mirror Finish |
| Noise Level | <55 dB(A) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | MFS |
| Instrument Type | Automated Membrane Filtration System for Microbial Enumeration |
| Detection Throughput | Up to 6 Samples Simultaneously |
| Filter Membrane Compatibility | 47 mm or 35 mm Diameter, Pore Sizes 0.22 µm and 0.45 µm |
| Construction Material | 316L Sintered Stainless Steel Support Pad, 316 Stainless Steel Body |
| Sterilization Options | Autoclaving (121°C, 15 min), Dry Heat (180°C, 120 min), or Flame Sterilization (PT-220 Butane Burner, Optional) |
| Dimensions (MFS-6B) | 810 × 160 × 205 mm |
| Net Weight (MFS-6B) | 11.5 kg |
| Vacuum Pump Options | SZKB-6A/B/C (Dual-Phase, Max Flow: 12 L/min gas / 6 L/min liquid, Ultimate Vacuum: 780 mbar) |
| Compliance | Designed in accordance with GB/T 8538–2008 (Methods for Examination of Drinking Natural Mineral Water), ISO 7218, USP <61> & <62>, and EU Pharmacopoeia 2.6.12 |
| Brand | HKM (Guangdong Huankai Microbial Technology Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Model | Smartcounter-4K/A, Smartcounter-4K/B, Smartcounter-4K/C |
| Instrument Type | Fully Automated Digital Colony Counter |
| Counting Speed | < 3 seconds per standard Petri dish (90–150 mm) |
| Optical Resolution | 8.29 MP |
| Minimum Detectable Colony Size | 0.2 mm |
| Max. Petri Dish Diameter | < 150 mm |
| Power Supply | AC 100–240 V, 50 Hz |
| Dimensions (W×D×H) | 290 × 260 × 380 mm |
| Compliance | Certified as Guangdong Provincial High-Tech Product (2014) |
| Regulatory Alignment | Designed to support GLP/GMP-compliant workflows with audit trail, user permission tiers, and data traceability per ISO/IEC 17025 and FDA 21 CFR Part 11 principles |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HMB X |
| Instrument Type | Fully Automated Microbial Activity Analyzer |
| Throughput | 100 samples per hour |
| Detection Principle | Peroxidase-Based Bioluminescent Enzymatic Assay |
| Output Units | BMR (Biological Metabolic Rate) and CFU/mL (or CFU/g) |
| Measurement Range | 0–19.99 BMR |
| Power Supply | 4 × AA batteries |
| Data Storage | Onboard memory with timestamped logging |
| Sample Forms | Liquids, solids, powders, slurries, and suspensions |
| Detection Time | ≤15 minutes per sample |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HMI-60 |
| Pricing | Upon Request |
| Inoculation Time | 9 or 13 s |
| Weight | 12 kg |
| Power Consumption | 120 W |
| Dimensions (L×W×H) | 335 × 250 × 415 mm |
| Inoculum Volume | 5 µL (24-position mode), 1 µL (60- and 96-position modes) |
| Petri Dish Compatibility | 90 mm diameter |
| Input Voltage | 220 V AC |
| Inoculation Pin Diameter | 3.0 mm (24-pin configuration), 1.6 mm (60-/96-pin configurations) |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HD-AN400 |
| Gas Environment | Microaerophilic (6% O₂) and Programmable O₂ (0.2–18%) |
| Operation Mode | Glove-Free Manual Access |
| Gas Supply | Standard Premixed Gases (e.g., 5% CO₂ / 10% H₂ / 85% N₂ or custom blends) |
| Chamber Capacity | Multi-Size Anaerobic Jars (7+ Configurations Available) |
| Temperature Range | 0–40 °C |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HD-AO10 |
| Pricing | Upon Request |
| Measurement Principle | Fluorescence Quenching (Non-Consumptive, Optical) |
| Oxygen Range | 0–25% O₂ (v/v) |
| Accuracy | ≤ ±2% FS |
| Temperature & Humidity Sensing | Integrated |
| Channel Scalability | Multi-channel expandable (up to 5 concurrent sensor inputs) |
| Power | Rechargeable Li-ion battery |
| Sensor Lifetime | ≥2 years (typical operational service life) |
| Display | ≥4-inch capacitive touchscreen |
| Processor | Dual-core architecture (ARM Cortex-M3 + high-speed FPGA) |
| Data Storage | Internal flash + microSD card (user-replaceable) |
| Communication | Modbus RTU over RS-485 |
| Calibration | Automatic on-power-up oxygen zero/span calibration support |
| Alarm Function | User-configurable high/low O₂ thresholds with timestamped event logging |
| Data Visualization | Real-time trend curves (O₂%, temperature, humidity) with exportable CSV format |
| Compliance | Designed for GLP-compliant laboratory workflows |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-ST20 |
| Price | Upon Request |
| Center Zone Temperature | 925 °C ±25 °C |
| Heating Zone Outer Diameter | φ15 mm |
| Heating Zone Length | 150 mm |
| Warm-up Time | ≤15 min |
| Standby Mode | Adjustable保温 setting for energy-efficient standby |
| Fuse Rating | 250 V, 3 A, 5×20 mm |
| Input Power | AC 220 V, 50–60 Hz, 150 W |
| Dimensions (W×D×H) | ≤120×155×180 mm |
| Standard Configuration | 1 × sterilizer main unit |
| Brand | Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Smartcounter-4K |
| Instrument Type | Fully Automated Colony Counter |
| Minimum Detectable Colony Size | 0.2 mm |
| Camera Resolution | 8.29 MP |
| Maximum Petri Dish Diameter | <150 mm |
| Power Supply | AC 100–240 V, 50 Hz |
| Dimensions (W×D×H) | 290 × 260 × 380 mm |
| Software Language | English & Chinese |
| Brand | Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Fully Automated Colony Counter |
| Counting Speed | 1 Petri dish per second |
| Camera Resolution | 8.29 Megapixels |
| Minimum Detectable Colony Size | 0.2 mm |
| Maximum Petri Dish Diameter | <150 mm |
| Dual LED Illumination System | Adjustable Color & Intensity (Top + Bottom) |
| Software Language | English / Chinese |
| Power Supply | AC 100–240 V, 50 Hz |
| Dimensions (W×D×H) | 290 × 260 × 380 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CHQC-20 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Detection Range | Adjustable |
| Detection Time | 24 h |
| Throughput | Configurable |
| Sampling Frequency | Configurable |
| Brand | IDEXX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | WQT2K |
| Detection Principle | Culture-Based Enzyme Substrate Method (DST) |
| Sample Types | Total Coliforms, Escherichia coli, Fecal Coliforms, Enterococci, Pseudomonas aeruginosa, Heterotrophic Plate Count (HPC) |
| Applicable Matrices | Drinking water, non-potable water, surface water, groundwater, medical wastewater, sewage, source water |
| Detection Time | 18–24 h |
| Quantification Range | 1–2,419 MPN/100 mL |
| Compliance | GB 5750.12–2006, ISO 9308-2:2012, US EPA Approved Method |
| Compatible Instrument | IDEXX Quanti-Tray Sealer (Model 2009D) |
| Packaging | Sterile, single-use, batch-certified with lot number and expiry date |
| Brand | IDEXX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WQT2KC |
| Price Range | USD 7–145 |
| Sample Types | Total Coliforms, Fecal Coliforms, Escherichia coli |
| Detection Volume | 100 mL |
| Incubation Time | 24 h |
| Regulatory Compliance | HJ 1001–2018, GB/T 5750.12–2023, US EPA Method 1603, Standard Methods 9223B, ISO 9308-2:2012 |
| Storage | Dark, light-protected, 12-month shelf life at ≤25 °C |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpira Dilutel® |
| Syringe Capacity | 1000 µL |
| Preset Inoculation Volumes | 50 µL, 100 µL, 200 µL |
| Counting Range | 30–1×10¹² CFU/mL |
| Cycle Time (1 aspiration + 1 disinfection + 1 plating) | 25 s |
| Cycle Time (1 disinfection + 5 dilutions + 1 plating at one dilution factor) | 134 s |
| Cycle Time (1 disinfection + 5 dilutions + 1 plating per dilution factor) | 234 s |
| Needle Pressure | up to 8 bar |
| Automatic Disinfection Cycles | 1000 cycles (using 2 L bottle) |
| Automatic Dilution Cycles | 63 cycles (using 2 L bottle) |
| Compatible Diluents | Saline, Ringer’s solution |
| Max. Petri Dishes per Sample (50 µL) | 20 |
| Spiral Plating Mode | Optional (Ø90 mm & Ø150 mm dishes) |
| Loop Plating Mode | Optional (3 dilutions on Ø90 mm |
| Uniform Plating Mode | Optional (Ø55 mm, Ø90 mm, Ø150 mm) |
| Pour Plate Mode | Optional (Ø55 mm, Ø90 mm, Ø150 mm) |
| Editable Inoculation Volume via USB | 10–1000 µL |
| Traceability | Excel™ export, LIMS integration, DataLink™ compatibility |
| Sterilizable Components | Two autoclavable bottles (diluent & disinfectant) + connectors |
| Cross-Contamination Prevention | Overflow cleaning technology |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro |
| Compliance | AFNOR V08-100, ISO 7218, SN/T 2098–2008 |
| Sample Volume Range | 10–1000 µL (programmable via USB) |
| Plating Time | ≤25 s per plate (including wash, aspirate, and spiral deposition) |
| Detection Range | 30–1.1 × 10⁷ CFU/mL |
| Sterilization | Autoclavable components (GL45 bottle adapters, needle assembly, base plate) |
| Cleaning System | Overflow-based internal/external needle rinse with real-time fluid-level sensing |
| Connectivity | USB interface for method programming, audit trail export, and GLP-compliant data logging |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro Milk |
| Syringe Capacity | 1000 µL |
| Preset Volumes | 50 µL, 100 µL, 200 µL |
| Adjustable Volume Range | 10–1000 µL via USB |
| Sample Input Format | Tube (80 × 35 mm) |
| CFU Counting Range | 10²–10⁷ CFU/mL |
| Cycle Time (aspiration + disinfection + plating) | 25 s |
| Needle Pressure | up to 8 bar |
| Auto-Disinfection Cycles per 2 L Bottle | 1000 |
| Auto-Rinse Cycles per 2 L Bottle | 600 |
| Max. Plates per Sample | 20 (at 50 µL) |
| Compatible Petri Dish Diameters | Ø90 mm and Ø150 mm |
| Plating Modes | Spiral (logarithmic), Pour, Loop (circular), Uniform |
| Compliance | ISO 7218, ISO 4833-2, FDA BAM, AOAC 977.27 |
| Voltage/Frequency | 100–240 V~, 50–60 Hz |
| Fuse | T1.6A L 250V, 5 × 20 mm |
| Power Consumption | 45 W |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro® |
| Dispensing Volume | 1000 µL |
| Preset Volumes | 50, 100, or 200 µL |
| Counting Range | 100–1×10⁷ CFU/mL |
| Cycle Time | 25 s |
| Overflow Pressure | 8 bar |
| Disinfectant Capacity (Standard Mode) | 600 cycles (2 L bottle) |
| Same-Sample Sequential Plating | up to 50 Petri dishes (50 µL each) |
| Automatic Disinfection Protocol | Compatible with 90 mm and 150 mm Petri dishes |
| Spiral Modes | Exponential, Circular, Uniform |
| Data Export | Excel™ format |
| Programmable Volume Range | 10–1000 mL |
| Dimensions | 38 × 42 × 29 cm |
| Weight | 15.6 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral® |
| Dispensing Volume | 1000 µL |
| Preset Volumes | 50 µL or 100 µL |
| Counting Range | 300–1.3 × 10⁵ CFU/mL |
| Cycle Time | 25 s |
| Overflow Pressure | 8 bar |
| Disinfectant Capacity (Standard Mode) | 600 cycles per 2 L bottle |
| Same-Sample Continuous Plating | up to 20 Petri Dishes (50 µL each) |
| Auto-Disinfection Protocol | Yes |
| Compatible Dish Diameter | 90 mm |
| Inoculation Pattern | Exponential Spiral & Circular Spiral |
| Dimensions | 38 × 42 × 29 cm |
| Weight | 15.6 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Compliance | AFNOR V08-100, ISO 7218 |