Microwave Digestion Instrument
Filter
Showing 1–30 of 50 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | SPEEDwave XPERT |
| Cavity Class | Civil-grade (non-industrial) |
| Max Temperature | 260 °C |
| Max Pressure | 100 bar |
| Vessel Volume Options | 40–100 mL |
| Vessel Material | High-purity TFM-PTFE |
| Pressure Monitoring | Optical Pressure Control (OPC), non-contact, per-vessel |
| Temperature Monitoring | Direct Infrared Control (DIRC), optical, per-vessel |
| Safety Features | Electrically actuated rotary lid with auto-locking, integrated gas absorption module, continuous cavity ventilation, rupture disc–equipped vessel caps, pressure-relief on opening |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Anton Paar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Anton Paar (Shanghai) Co., Ltd. |
| Product Type | Domestic Manufacturing |
| Model | Multiwave 5001 CN |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 96 samples per batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Temperature Measurement Accuracy | ±0.1 °C |
| Temperature Control Stability | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Max Pressure | 100 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Multiwave 5001CN |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 96 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 100 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Multiwave 7101 / 7301 / 7501 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | Up to 41 positions (configurable) |
| Microwave Source | Single 2000 W Magnetron |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.3 °C |
| Temp Uniformity | Full-cavity uniformity (no spatial gradient) |
| Max Pressure | 199 bar |
| Brand | Anton Paar |
|---|---|
| Country of Origin | Austria |
| Model | Multiwave GO Plus |
| Cavity Class | Industrial-grade |
| Sample Capacity | 12 samples per run |
| Microwave Source | Industrial Magnetron |
| Max Temperature | 260 °C / 300 °C (depending on vessel type) |
| Max Pressure | 2200 psi |
| Cooling Time (12-position rotor, 180 °C → 70 °C) | ≤8 min (EPA-compliant) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | BUS |
| Price Range | USD 56,000 – 70,000 |
| Cavity Class | Industrial Grade |
| Maximum Sample Capacity | 40 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 305 °C |
| Max Pressure | 22,000 psi |
| Input Power | 220 VAC, 50 Hz, 15 A |
| Total System Power | 3600 W |
| Microwave Output Power | 2200 W |
| Output Mode | Non-pulsed, continuous microwave (0–2200 W adjustable) |
| Cavity Volume | 66 L |
| Cavity Material | 316 stainless steel with multi-layer PTFE-based high-temp corrosion-resistant coating |
| Cooling | Integrated high-turbulence forced-air cooling system |
| Safety | Aerospace-grade composite fiber outer vessels with 3D vertical explosion containment, real-time pressure/temperature monitoring, electromagnetic leakage < 1 mW/cm² (per GB 10436 & IEC 61000-3-2) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | M24 |
| Price Range | USD 17,000 – 28,000 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 24 vessels |
| Microwave Source | High-Power Industrial Magnetron |
| Max Temperature | 310 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±1 °C |
| Temp Uniformity Across Cavity | ±1 °C |
| Max Operating Pressure | 2250 psi |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MD20H |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 20 samples per batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 2250 psi |
| Brand | APL Optimum |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Touchwin2.0 (XiaoLe) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 16 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 2200 psi |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Touchwin2.0 (18-Position) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 18 |
| Microwave Source | High-Power Magnetron |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.01 °C |
| Temp Control Stability | ±1 °C |
| Temp Uniformity | ±0.01 °C |
| Max Pressure | 15 MPa |
| Brand | APL Optimum |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Touchwin4.0 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 40 samples/batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 310 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.1 °C |
| Temp Uniformity | ±0.1 °C |
| Max Pressure | 22,000 psi |
| Brand | APL Optolab |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Touchwin2.0 (Da’ao) |
| Price Range | USD 28,000 – 49,000 |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 40 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 310 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.1 °C |
| Temp Uniformity Across Cavity | ±0.1 °C |
| Max Operating Pressure | 22,000 psi |
| Brand | Berghof |
|---|---|
| Origin | Germany |
| Model | SW-Xpert |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 32 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 1450 psi |
| Output Power | 2000 W |
| Compliance | FDA 21 CFR Part 11, ISO/IEC 17025-compatible workflows, GLP/GMP-ready audit trail |
| Brand | Berghof |
|---|---|
| Origin | Germany |
| Model | Speedwave Xpert |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 32 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 1450 psi |
| Output Power | 2000 W |
| Compliance | FDA 21 CFR Part 11 |
| Brand | Berghof |
|---|---|
| Origin | Germany |
| Model | SW-Entry |
| Cavity Class | Industrial-grade |
| Sample Capacity | 24 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 230 °C |
| Max Pressure | 75 bar |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | NJ-40-55ml |
| Sample Capacity | 40 vessels |
| Vessel Volume | 55 mL |
| Liner Material | TFM (Modified PTFE) |
| Compatible Platform | CEM MARS 6 Microwave Digestion Systems |
| Max Operating Temperature | 260 °C |
| Max Operating Pressure | 50 bar |
| Temperature Measurement Accuracy | ±2 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Control Stability | High repeatability under dynamic microwave load |
| Microwave Source | Magnetron-based power supply (system-integrated) |
| Brand | CEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BLADE |
| Quotation | Upon Request |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 24 Samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 310 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.1 °C |
| Temp Uniformity | 0.01 °C |
| Max Pressure | Not Applicable |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Clean-STAR |
| Chamber Class | Industrial-Grade |
| Sample Capacity | 2–6 positions |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 500 °C |
| Operating Pressure | Ambient (Atmospheric) |
| Vessel Options | PTFE (30 mL, 70 mL), Quartz (100 mL) |
| Software | STAR LINK™ PC Interface, 20 Predefined Methods, Real-Time Temp/Time Curve Visualization, Endpoint Detection via Moisture/Volatility Sensing, Integrated Gas Absorption Module |
| Safety | Automated Interlock, Overtemperature & Overpressure Monitoring, HEPA-Filtered Inert Gas Purge (N₂ or Clean Air) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DISCOVER SP-D |
| Price | Upon Request |
| Cavity Class | Industrial-Grade |
| Sample Capacity | Automated 48/72/96-Position |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 27 bar |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | MARS 6 |
| Batch Capacity | 0–40 samples |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 260 °C / 330 °C |
| Temp Accuracy | ±0.1 °C |
| Temp Stability | ±0.1 °C |
| Temp Uniformity | ±0.1 °C |
| Max Pressure | 500 psi / 2200 psi |
| Cavity Volume | 66 L |
| Microwave Output Power | 1800 W (IEC 705:1988) |
| Operating Voltage | 220 VAC, 50 Hz, 15 A |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | MARS 7 |
| Chamber Class | Industrial-Grade |
| Batch Capacity | 40 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 350 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.1 °C |
| Temp Uniformity | ±0.1 °C |
| Max Pressure | 3000 psi |
| Brand | CEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MARS Xpress 2.0 |
| Price | Upon Request |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 1–40 |
| Microwave Source | Dual Magnetron |
| Maximum Temperature | 330 °C |
| Maximum Pressure | 1500 psi |
| Temperature Measurement Accuracy | Contact manufacturer |
| Temperature Control Stability | Contact manufacturer |
| Temperature Uniformity | Contact manufacturer |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | STAR-Plus 6/2 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 2 / 4 / 6 positions |
| Microwave Source | Single or Dual Magnetron |
| Max Operating Temperature | 500 °C (reaction zone), 300 °C (vessel wall) |
| Pressure Regime | Ambient (atmospheric-pressure operation) |
| Temperature Control Range | 0–430 °C |
| Temp. Accuracy | ±1 °C |
| Reaction Vessel Options | 50 / 100 / 250 mL |
| Vessel Materials | Borosilicate Glass, Quartz, PTFE |
| Organic Sample Mass Capacity | Up to 10 g |
| Reagent Addition Stations | 12–24 independent channels |
| Preloaded Methods | 20 methods × up to 40 steps each |
| Compliance | EPA Method 3050B, ISO 14001-aligned exhaust management |
| Brand | Chuanna Instrument |
|---|---|
| Origin | Zhejiang, China |
| Model | CNWB-6 |
| Sample Capacity | 6 positions |
| Max Temperature | 300 °C |
| Temp Uniformity | ±0.5 °C |
| Max Pressure | 0–6 MPa |
| Microwave Frequency | 2450 MHz |
| Power Output | 0–1600 W (continuously variable, non-pulsed, auto-frequency modulation) |
| Cavity Volume | 52 L |
| Cavity Material | 316 stainless steel with 6-layer PTFE coating |
| Cooling | High-capacity acid-resistant centrifugal blower (≥5 m³/min), integrated forced-air cavity cooling |
| Control Interface | 8-inch TFT-LCD touchscreen (800×480) with real-time temperature/pressure curve display |
| Temperature Sensing | Contact-type Pt100 sensor |
| Pressure Sensing | Non-contact pressure transducer |
| Pressure Accuracy | ±0.01 MPa |
| Safety Features | Auto-shutoff on over-pressure, dual-stage rupture disc, self-locking shock-absorbing blast door, microwave leakage <5 mW/cm² (per GB 4706.21 & IEC 60335-2-90) |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | CYWB-10 |
| Sample Capacity | 10 vessels per run |
| Max Temperature | 190 °C |
| Temperature Control Stability | Non-pulsed continuous microwave frequency modulation |
| Max Pressure | 1500 psi (10.34 MPa) |
| Cavity Volume | 52 L |
| Cavity Material | 316L stainless steel with 6-layer PTFE coating |
| Power Supply | 220–240 VAC, 50/60 Hz, 15 A |
| Microwave Frequency | 2450 MHz |
| Output Power | 0–1600 W, continuously adjustable |
| Cooling Airflow | ≥5 m³/min |
| Display | 8-inch TFT-LED touchscreen (800×480) |
| Temp Sensing | Contact-type Pt100 RTD (±0.5 °C accuracy) |
| Pressure Sensing | Non-contact piezoelectric sensor (0.01 MPa resolution) |
| Vessel Material | PEEK outer vessel + PTFE inner liner |
| Vessel Volume | 100 mL |
| Rotation | 360° continuous unidirectional rotation |
| Safety Features | Auto-locking buffered anti-explosion door, dual-safety burst disc (ceramic-clamped), real-time pressure/temperature cutoff, electromagnetic leakage <5 mW/cm² (GB 10436-2008 compliant) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-WB10 |
| Chamber Rating | Industrial-Grade |
| Sample Capacity | ≥4 samples per batch |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-WB12 |
| Cavity Grade | Industrial-Grade |
| Sample Capacity | ≥12 samples/batch |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact infrared, 0–300 °C, ±0.5 °C accuracy |
| Pressure Safety | Automatic pressure relief |
| Rotational Mode | 360° continuous unidirectional rotation |
| Vessel Material | PTFE inner vessel, PEEK outer protective sleeve |
| Inner Vessel Volume | 55 mL |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-WB4 |
| Price | USD 3,950 (FOB) |
| Cavity Class | Industrial-Grade |
| Batch Capacity | ≥4 Samples |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact Infrared Sensor, Range 0–300 °C, Accuracy ±0.5 °C |
| Pressure Safety | Automatic Overpressure Release |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |
| Vessel Material | PTFE Inner Vessels, PEEK Reinforced Outer Sleeves |
| Vessel Volume | 55 mL |
| Rotation | 360° Continuous Unidirectional Turntable |
| Includes | Digestion Unit, Parallel Acid Evaporation Unit (Matching 4-position), 4× PTFE/PEEK Vessel Sets, Rotating Tray, User Manual, Certificate of Conformance |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-WB6 |
| Price | USD 4,500 (approx.) |
| Cavity Grade | Industrial-Grade |
| Batch Capacity | ≥6 Samples |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact Infrared, 0–300 °C, ±0.5 °C Accuracy |
| Pressure Safety | Automatic Pressure Relief |
| Rotational Mode | 360° Continuous Unidirectional Rotation |
| Inner Vessel Material | PTFE |
| Outer Vessel Material | PEEK |
| Inner Vessel Volume | 55 mL |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-WB8 |
| Price | USD 5,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Batch Capacity | ≥8 samples |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact infrared, ±0.5 °C accuracy |
| Rotation | 360° continuous synchronous rotation |
| Vessel Material | PFA inner vessel, PEEK outer sleeve |
| Vessel Volume | 55 mL |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |