| Brand | CEM |
|---|---|
| Origin | USA |
| Model | STAR-Plus 6/2 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 2 / 4 / 6 positions |
| Microwave Source | Single or Dual Magnetron |
| Max Operating Temperature | 500 °C (reaction zone), 300 °C (vessel wall) |
| Pressure Regime | Ambient (atmospheric-pressure operation) |
| Temperature Control Range | 0–430 °C |
| Temp. Accuracy | ±1 °C |
| Reaction Vessel Options | 50 / 100 / 250 mL |
| Vessel Materials | Borosilicate Glass, Quartz, PTFE |
| Organic Sample Mass Capacity | Up to 10 g |
| Reagent Addition Stations | 12–24 independent channels |
| Preloaded Methods | 20 methods × up to 40 steps each |
| Compliance | EPA Method 3050B, ISO 14001-aligned exhaust management |
| Brand | Chuanna Instrument |
|---|---|
| Origin | Zhejiang, China |
| Model | CNWB-6 |
| Sample Capacity | 6 positions |
| Max Temperature | 300 °C |
| Temp Uniformity | ±0.5 °C |
| Max Pressure | 0–6 MPa |
| Microwave Frequency | 2450 MHz |
| Power Output | 0–1600 W (continuously variable, non-pulsed, auto-frequency modulation) |
| Cavity Volume | 52 L |
| Cavity Material | 316 stainless steel with 6-layer PTFE coating |
| Cooling | High-capacity acid-resistant centrifugal blower (≥5 m³/min), integrated forced-air cavity cooling |
| Control Interface | 8-inch TFT-LCD touchscreen (800×480) with real-time temperature/pressure curve display |
| Temperature Sensing | Contact-type Pt100 sensor |
| Pressure Sensing | Non-contact pressure transducer |
| Pressure Accuracy | ±0.01 MPa |
| Safety Features | Auto-shutoff on over-pressure, dual-stage rupture disc, self-locking shock-absorbing blast door, microwave leakage <5 mW/cm² (per GB 4706.21 & IEC 60335-2-90) |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | CYWB-10 |
| Sample Capacity | 10 vessels per run |
| Max Temperature | 190 °C |
| Temperature Control Stability | Non-pulsed continuous microwave frequency modulation |
| Max Pressure | 1500 psi (10.34 MPa) |
| Cavity Volume | 52 L |
| Cavity Material | 316L stainless steel with 6-layer PTFE coating |
| Power Supply | 220–240 VAC, 50/60 Hz, 15 A |
| Microwave Frequency | 2450 MHz |
| Output Power | 0–1600 W, continuously adjustable |
| Cooling Airflow | ≥5 m³/min |
| Display | 8-inch TFT-LED touchscreen (800×480) |
| Temp Sensing | Contact-type Pt100 RTD (±0.5 °C accuracy) |
| Pressure Sensing | Non-contact piezoelectric sensor (0.01 MPa resolution) |
| Vessel Material | PEEK outer vessel + PTFE inner liner |
| Vessel Volume | 100 mL |
| Rotation | 360° continuous unidirectional rotation |
| Safety Features | Auto-locking buffered anti-explosion door, dual-safety burst disc (ceramic-clamped), real-time pressure/temperature cutoff, electromagnetic leakage <5 mW/cm² (GB 10436-2008 compliant) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-WB10 |
| Chamber Rating | Industrial-Grade |
| Sample Capacity | ≥4 samples per batch |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-WB12 |
| Cavity Grade | Industrial-Grade |
| Sample Capacity | ≥12 samples/batch |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact infrared, 0–300 °C, ±0.5 °C accuracy |
| Pressure Safety | Automatic pressure relief |
| Rotational Mode | 360° continuous unidirectional rotation |
| Vessel Material | PTFE inner vessel, PEEK outer protective sleeve |
| Inner Vessel Volume | 55 mL |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-WB4 |
| Price | USD 3,950 (FOB) |
| Cavity Class | Industrial-Grade |
| Batch Capacity | ≥4 Samples |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact Infrared Sensor, Range 0–300 °C, Accuracy ±0.5 °C |
| Pressure Safety | Automatic Overpressure Release |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |
| Vessel Material | PTFE Inner Vessels, PEEK Reinforced Outer Sleeves |
| Vessel Volume | 55 mL |
| Rotation | 360° Continuous Unidirectional Turntable |
| Includes | Digestion Unit, Parallel Acid Evaporation Unit (Matching 4-position), 4× PTFE/PEEK Vessel Sets, Rotating Tray, User Manual, Certificate of Conformance |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-WB6 |
| Price | USD 4,500 (approx.) |
| Cavity Grade | Industrial-Grade |
| Batch Capacity | ≥6 Samples |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact Infrared, 0–300 °C, ±0.5 °C Accuracy |
| Pressure Safety | Automatic Pressure Relief |
| Rotational Mode | 360° Continuous Unidirectional Rotation |
| Inner Vessel Material | PTFE |
| Outer Vessel Material | PEEK |
| Inner Vessel Volume | 55 mL |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-WB8 |
| Price | USD 5,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Batch Capacity | ≥8 samples |
| Max Temperature | 300 °C |
| Max Pressure | 1500 psi |
| Temperature Control | Non-contact infrared, ±0.5 °C accuracy |
| Rotation | 360° continuous synchronous rotation |
| Vessel Material | PFA inner vessel, PEEK outer sleeve |
| Vessel Volume | 55 mL |
| Dimensions (L×W×H) | 507 × 619.5 × 666 mm |
| Net Weight | 50 kg |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-D Clinical |
| Price Range | USD 55,000–68,000 (est.) |
| Cavity Class | Research/CLIA-Compliant |
| Sample Capacity | Auto-configurable 48/72/96 positions |
| Microwave Source | Dual Magnetron (Selectable Single/Dual Mode) |
| Max Temperature | 300 °C |
| Max Pressure | 100 bar |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-WB6 |
| Price | USD 4,900 (FOB Qingdao) |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 40 Samples |
| Brand | HePu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | MWD-500 |
| Sample Capacity | 1–6 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 250 °C |
| Max Pressure | 5 MPa |
| Cavity Volume | 65 L |
| Vessel Material | TFM-lined inner vessel |
| Pressure Control | Multi-fiber optical non-contact scanning pressure monitoring |
| Temperature Monitoring | Mid-infrared in-vessel temperature sensing |
| Power Range | 0–1000 W (2450 MHz) |
| Rotation | 360° continuous rotation platform |
| Safety Compliance | <5 mW/cm² microwave leakage |
| Dimensions (W×D×H) | 520 × 560 × 460 mm |
| Net Weight | 32 kg |
| Brand | Environmental Express |
|---|---|
| Origin | USA |
| Model | ABF5000 |
| Cavity Class | Industrial-Grade |
| Sample Throughput | Up to 96 wells per run (compatible with HotBlock®, HotBlock Pro®, and HotBlock 200 formats) |
| Reagent Dispensing Accuracy | ±0.5% CV (based on Masterflex peristaltic pump performance) |
| Dispensing Range | 0.1–100 mL per well |
| Increment Resolution | 0.1 mL |
| Power Supply | 120/240 VAC, 50/60 Hz |
| Footprint | 30.5 × 25.4 × 35.6 cm (W × D × H) |
| Included Components | Integrated control software, dual-channel Masterflex peristaltic pump, PTFE tubing set, five 1-L glass reagent bottles, one 100-mL waste bottle, mounting hardware, touchscreen interface |
| Brand | Environmental Express |
|---|---|
| Origin | USA |
| Model | SC2050-36V240 |
| Sample Capacity | 96 × 15 mL |
| Max Temperature | 200°C |
| Temperature Uniformity | ±0.2°C |
| Heating Block Material | PTFE-coated graphite |
| Enclosure Material | Kydex® |
| External Controller Support | Yes (up to 2 units) |
| Input Voltage | 240 VAC |
| Power Consumption | 6.5 A |
| Dimensions (W × L) | 15" × 21.5" |
| Weight | 83 lb |
| Compliance | Designed for EPA, ASTM, and ISO-compliant sample preparation workflows |
| Safety | Non-metallic construction eliminates metallic contamination and corrosion risk |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MASTER |
| Pricing | Upon Request |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 14 / 16 / 18 / 40 / 100 vessels per batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 310 °C |
| Max Pressure | 2200 psi |
| Brand | Hanon |
|---|---|
| Origin | Shanghai, China |
| Model | MDS-15 |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 16 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300°C |
| Max Pressure | 10 MPa |
| Cavity Volume | 65 L |
| Power Output | 1600 W (continuous, frequency-variable) |
| Pressure Sensing | Piezoelectric Crystal Sensor (0–15 MPa, ±0.01 MPa) |
| Temperature Sensing | High-Precision Pt100 RTD (0–350°C, ±1°C) |
| Safety Door | Auto-Pop™ Passive Explosion-Relief Sliding Door with Dual Electronic/Mechanical Interlock |
| Cooling | Turbulent Air-Cooling System (200°C → 60°C in ≤15 min) |
| External Frame Material | 316L Stainless Steel with Multi-Layer PFA Coating |
| Outer Vessel Material | Xtra Fiber™ Aerospace-Grade Composite (rated to 600°C / 66 MPa) |
| [Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | Titan-10 |
| Sample Capacity | 10 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 15 MPa |
| Cavity Construction | Industrial-grade 316L stainless steel with 8-layer PFA coating |
| Safety Architecture | Triple-redundant pressure monitoring, bow-spring pressure relief module + burst disc, auto-ejecting safety door, 3D directional explosion containment, aerospace-grade composite outer vessels rated to 80 MPa (12,500 psi) |
| Control System | PID-based closed-loop power regulation with Pt100 temperature sensor (−40–500 °C, ±0.1 °C accuracy) and piezoelectric pressure sensor (0–20 MPa, ±0.01 MPa control precision) |
| Dimensions | 480 × 550 × 630 mm (W × D × H) |
| Net Weight | 57 kg |
| Operating Environment | 15–80% RH, RT–50 °C] |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TITAN-12 |
| Price Range | USD 21,000 – 28,000 (FOB Shanghai) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 12 vessels |
| Microwave Source | Dual Magnetron (2 × 1000 W, independent control) |
| Maximum Temperature | 500 °C |
| Maximum Pressure | 20 MPa |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Titan-15 |
| Price | USD 23,000 (FOB Shanghai) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 15 vessels |
| Microwave Source | Dual Magnetron |
| Max Operating Temperature | 300 °C |
| Max Working Pressure | 15 MPa |
| Brand | Hengping |
|---|---|
| Model | Titan-16 |
| Origin | Shanghai, China |
| Instrument Type | High-throughput sealed microwave digestion/extraction system |
| Sample Capacity | 16 positions |
| Microwave Source | Dual magnetron (2 × 1000 W) |
| Max Temperature | 300 °C |
| Max Pressure | 15 MPa |
| Cavity Material | 316L stainless steel with 8-layer PFA coating |
| Safety Certification | Integrated active/passive pressure relief, auto-locking door with real-time status monitoring, aerospace-grade composite outer vessels rated to 80 MPa (11,600 psi) |
| Temperature Sensing | Platinum resistance sensor (−40 °C to 500 °C |
| Pressure Sensing | Piezoelectric crystal sensor (0–20 MPa |
| Rotation | Unidirectional continuous rotation |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions (L×W×H) | 480 × 550 × 630 mm |
| Net Weight | 57 kg |
| Operating Environment | 15–80% RH, ambient temperature up to 50 °C |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TITAN-24 |
| Price Range | USD 28,000 – 42,500 (FOB Shanghai) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 24 positions |
| Microwave Source | Dual Magnetron (2 × 1.2 kW) |
| Max Temperature | 500 °C |
| Max Pressure | 20 MPa |
| Brand | Hengping |
|---|---|
| Model | Titan-6 |
| Origin | Shanghai, China |
| Instrument Type | Sealed Microwave Digestion System for Sample Preparation |
| Sample Capacity | 6 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 15 MPa |
| Cavity Construction | Industrial-grade 316L stainless steel with 8-layer PFA coating |
| Safety Architecture | Triple-redundant pressure monitoring (piezoelectric sensor + bow-spring elastic module + burst disc), auto-venting door mechanism, 3D directional explosion containment, aerospace-grade composite fiber outer vessels rated to 80 MPa (12,500 psi) |
| Control System | PID-based closed-loop power regulation with real-time temperature/pressure feedback |
| Operating Frequency | 2450 MHz |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions (L×W×H) | 480 × 550 × 630 mm |
| Net Weight | 57 kg |
| Ambient Operating Range | RT–50 °C, 15–80% RH |
| [Brand | HePu (Jinan Hepu Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Model | MWD-600 |
| Sample Capacity | 1–10 vessels |
| Microwave Source | Single magnetron |
| Max Temperature | 250 °C |
| Max Operating Pressure | 6 MPa |
| Cavity Volume | 65 L |
| Vessel Material | TFM-lined inner vessel, PEEK + fiberglass reinforced outer vessel |
| Pressure Control | Multi-fiber non-contact scanning pressure monitoring |
| Temperature Control | Mid-infrared non-contact scanning temperature monitoring |
| Power Range | 0–1500 W (2450 MHz) |
| Rotation | 360° continuous rotation |
| Safety Compliance | <5 mW/cm² microwave leakage, dual-safety interlock door, auto-resealing pressure relief, over-pressure/over-temperature cut-off, real-time fault diagnostics |
| Software | 255 programmable methods, 10-step per method, in-process parameter adjustment, audit-ready method logging] |
| Brand | HePu (Ji'nan, Shandong) |
|---|---|
| Origin | China |
| Model | MWD-700 |
| Sample Capacity | 1–18 vessels |
| Microwave Source | Dual Magnetron |
| Max Operating Temperature | 250 °C (up to 300 °C vessel rating) |
| Max Operating Pressure | 0–6 MPa (vessel burst pressure: 20 MPa) |
| Temperature Measurement Range | Ambient–400 °C (±1 °C) |
| Pressure Measurement Range | 0–10 MPa (±0.1 MPa) |
| Microwave Frequency | 2450 MHz |
| Output Power | 0–2500 W (adjustable) |
| Input Power | 3400 W, 220 V AC, 50/60 Hz, 16 A |
| Cavity Ventilation | >5 m³/min corrosion-resistant blower |
| Microwave Leakage | <5 mW/cm² (compliant with GB 10436 and IEC 61000-3-2) |
| [Brand | HePu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | MWD-800 |
| Sample Capacity | 1–20 vessels (upgradable to 40/70 high-throughput rotors) |
| Microwave Source | Single magnetron |
| Max Temperature | 250 °C |
| Max Operating Pressure | 6 MPa |
| Cavity Volume | 65 L |
| Power Output | 0–3000 W (variable-frequency continuous mode) |
| Pressure Control | Multi-fiber non-contact scanning pressure monitoring |
| Temperature Control | Mid-infrared non-contact scanning temperature monitoring |
| Vessel Material | TFM-lined inner vessels |
| Safety Certification | Dual-pressure/temperature interlock, auto-resealing rupture disc, 360° continuous rotation, <5 mW/cm² microwave leakage] |
| Brand | Jihepu |
|---|---|
| Origin | Shandong, China |
| Model | MWD-520 |
| Sample Capacity | 1–6 vessels |
| Microwave Source | Dual Magnetron |
| Max Operating Temperature | 250 °C (up to 300 °C peak) |
| Max Operating Pressure | 5 MPa (up to 6 MPa burst) |
| Vessel Volume | 60 mL |
| Temperature Accuracy | ±1 °C (range: ambient to 300 °C) |
| Pressure Accuracy | ±0.1 MPa (range: 0–5 MPa) |
| Microwave Power Output | 0–1000 W (2450 MHz) |
| Cavity Ventilation | >5 m³/min corrosion-resistant blower |
| Microwave Leakage | <5 mW/cm² |
| Dimensions (W×D×H) | 520 × 400 × 460 mm |
| Net Weight | ~30 kg |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Brand | JRY |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JRY-X350-18 |
| Rated Power | 4000 W |
| Max Temperature | 350 °C |
| Temp. Accuracy | ±1 °C |
| Sample Capacity | 18 × Ø58 mm × H30 mm vessels |
| Heating Zone Dimensions | 585 mm × 350 mm |
| Weight | 20 kg |
| Voltage/Frequency | 220 V / 50 Hz |
| Control Method | Digital PID Temperature Control with Real-Time Display |
| Construction Material | High-Purity Graphite Block with Acid- and Alkali-Resistant Coating |
| Application Scope | Soil, Food, Biological Tissues, Agricultural Products, Wastewater Sludge, Cosmetics, Clinical Specimens |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MWD-2 |
| Output Power | 800 W |
| Input Power | 1300 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Digestion Chamber Capacity | 15 L |
| Net Weight (incl. chamber) | 20.1 kg |
| Dimensions (W×D×H) | Not specified |
| Chamber Material | PTFE |
| Ventilation System | Integrated acid/alkali scrubbing exhaust with vacuum pump |
| Control | Microprocessor-based power/time programming |
| Chamber Design | Stirred-mode (rotating waveguide) 3D microwave field generation |
| Effective Cavity Volume Increase | ~25% vs. turntable-based systems |
| Brand | Labo (Tianjin Labo / LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QLABPro |
| Price Range | USD $26,000–$39,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 12 or 20 vessels |
| Microwave Source | Magnetron |
| Max Temperature | 230 °C (standard mode) / 400 °C (high-temp mode) |
| Max Pressure | 500 psi |
| Exhaust Flow Rate | 150 CFM |
| Output Power | Up to 1200 W |
| Safety Features | Spring-loaded interlocked door, overpressure venting, real-time per-vessel T/P monitoring, thermal runaway detection, PTFE-coated cavity |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | REVO |
| Pricing | Available Upon Request |
| Cavity Grade | Industrial-Grade |
| Sample Capacity | 40 Vessels |
| Microwave Source | Dual Industrial Magnetrons |
| Max Operating Temperature | Up to 300 °C (typical for high-pressure digestion) |
| Temp. Measurement Accuracy | ±0.5 °C (infrared, full-vessel monitoring) |
| Temp. Control Stability | ±1 °C over 30 min |
| Temp. Uniformity Across Cavity | ±3 °C (validated per ASTM E2912-13) |
| Max Pressure Rating | 150 bar (burst-tested to 225 bar) |
| Brand | LabTech |
|---|---|
| Model | VB15 |
| Origin | Beijing, China |
| Equipment Type | Microwave-Assisted Digestion & Post-Digestion Acid Evaporation System |
| Cavity Rating | Industrial-Grade |
| Application Scope | Sample preparation for AA, ICP-MS, ICP-AES, and other elemental analysis techniques |
| Temperature Uniformity | ≤ ±1 °C at 100 °C |
| Energy Efficiency | >50% reduction vs. conventional hotplate evaporation |
| Throughput Advantage | 2–5× faster acid removal vs. traditional methods |
| Control Mode | Programmable timer-based operation |
| Compliance Context | Designed to support GLP-compliant sample prep workflows in environmental, food, pharmaceutical, and clinical laboratories |