Multifunctional Autosampler
Filter
Showing 1–30 of 83 results
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACQ-06 |
| Pricing | Available Upon Request |
| Instrument Type | Liquid Chromatography Column Switching Module |
| Fluidic Path Materials | SS316L, PTFE, ETFE, PEEK |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi AGS-36 |
| Valve System | 6-port rotary valve |
| Temperature Control Range (Valve, Quantitative Loop & Transfer Line) | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Volume | 1.0 mL (customizable from 50 µL to 5 mL via quantitative loop) |
| Sample Positions | 36 (expandable to 90 positions via modular 36+18N configuration) |
| Sampling Time | 0–99.9 s |
| Loop Equilibration Time | 0–99.9 s |
| Injection Channels | 1 (customizable) |
| Repeatability | <0.5% RSD (at 100 ppm total hydrocarbons or methane) |
| Power Consumption | 300 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 55 × 42 × 58 cm |
| Weight | ~25 kg |
| Sampling Pump | Corrosion-resistant diaphragm pump |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Software | PC-based control with bilingual (English/Chinese) GUI, full audit trail, GLP-compliant event logging |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi AGS-72 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Positions | 72 |
| Max Repeated Injections | Unlimited |
| Min Injection Volume | 0.5 mL (customizable) |
| Quantitative Loop Volume | 1 mL (customizable) |
| Positioning Accuracy | <0.3 mm |
| Motion Control | Precise Valve Switching |
| Needle Cleaning Method | Reverse Purge |
| Reproducibility | <1.5% RSD (at 100 ppm methane) |
| Power Consumption | 300 W |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 55 × 42 × 58 cm |
| Weight | ~25 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi AGS-H25 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Capacity | 25 positions |
| Minimum Injection Volume | 0.5 mL (customizable) |
| Quantitative Loop Volume | 1 mL (customizable) |
| Positioning Accuracy | <0.3 mm |
| Motion Control | Precision valve-switching actuation |
| Needle Cleaning Method | Reverse purge |
| Repeated Injection Capability | Unlimited |
| Valve & Tubing Temperature Range | Ambient to 220 °C ±0.1 °C |
| Sample Port Temperature Range | Ambient to 150 °C ±1 °C |
| Reproducibility | <1.5% RSD (at 100 ppm methane) |
| Power Consumption | 1500 W |
| Electrical Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 725 × 500 × 680 mm |
| Weight | ~55 kg |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-051 |
| Instrument Type | Preparative HPLC/LC Autosampler |
| Maximum Sample Capacity | 5 vials |
| Minimum Sample Volume per Injection | 1 mL |
| Loop Volume Range | 2–20 mL |
| Positioning Accuracy | ±0.1 mm (verified by encoder feedback) |
| Drive Mechanism | Precision Syringe Pump |
| Needle Wash | Integrated Solvent Flush with Dual-Path Solvent Selection |
| Repeat Injection Capability | Unlimited cycles per sample |
| Maximum Single Injection Volume | 50 mL |
| Compatibility | Standalone operation or integration with third-party preparative LC systems (e.g., Gilson, Biotage, Teledyne ISCO, Shimadzu, Waters) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-A5 |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 108 × 2 mL vials (standard), optional configurations available |
| Injection Modes | Full-loop, Partial-loop, and Needle-in-Loop (NIL) injection |
| Injection Volume Range | 0.1–25 µL (with standard loop) |
| Precision | RSD < 0.25% (full-loop), < 0.5% (partial-loop, >10 µL), < 0.8% (NIL, <5 µL) |
| Carryover | < 0.05% |
| Maximum System Pressure | 40 MPa (standard HPLC), 60 MPa (UHPLC-compatible) |
| Safety Features | Vial-missing detection, needle-strike alarm, tubing blockage detection, leak monitoring |
| Optional | Peltier-based sample cooling module |
| Dimensions (W×D×H) | 300 × 450 × 320 mm |
| Weight | ~25 kg |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Bio-Inert Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Operating Pressure | Up to 600 bar |
| Carryover | <9 ppm |
| Temperature Control Range (Optional) | 4–40 °C |
| Flow Path Materials | Ceramic needle, PEEK needle seat, stainless-steel-coated PEEK capillary |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Hybrid Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity III Manual Injector |
| Instrument Type | HPLC Manual Injector |
| Maximum Operating Pressure | 600 bar |
| Footprint Compatibility | Designed to match all 1260 Infinity series modules |
| Column Mounting Option | Optional column holder integrated into baseplate |
| Valve Construction | Ceramic stator surface for wear resistance and long-term sealing integrity |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure | Up to 600 bar (standard), up to 800 bar (with optional high-pressure kit) |
| Carryover | <9 ppm |
| Temperature Control Range (optional integrated thermostat) | 4–40 °C |
| Sample Tray Configurations | Three-height drawer system supporting vials and microplates |
| Microplate Capacity | Up to 16 standard microplates per drawer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Online Sampling Module |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 432 vials (2 mL) |
| Minimum Injection Volume | 0.1 µL |
| Dilution Ratio | Up to 1:1000 |
| Sampling Interface | External process-coupled interface for PAT integration |
| Compatible Injection Modes | Flow-through injection and Agilent FEED (Fast Equilibration Enhanced Dilution) injection |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Sample Tray Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 600 bar (G7129A) / 800 bar (G7129C) |
| Injection Volume Range | 0.1–100 µL (standard), extendable to 1500 µL (G7129C) or 1800 µL (G7129A) |
| Needle Wash Port | External surface rinse |
| Optional Integrated Column Oven | Temperature range 5 °C above ambient to 80 °C, accommodates two columns up to 30 cm |
| Optional Integrated Sample Thermostat | 4–40 °C temperature control |
| Internal Volume | Minimized design with bypass mode available |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III SFC Multisampler |
| Instrument Type | Supercritical Fluid Chromatography (SFC) Autosampler |
| Maximum Sample Capacity | 6144 |
| Injection Volume Range | 0.1–90 µL |
| Sample Container Compatibility | 2 mL Vials and Microtiter Plates (e.g., 96-well, 384-well) |
| Injection Technology | FEED (Forced Expansion and Efficient Delivery) |
| Temperature Control | Active Peltier-based Cooling/Heating |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Temperature Control Range (optional integrated chiller/heater) | 4–40 °C |
| Sample Tray Flexibility | Three-height drawer configuration supporting vials and microplates (including shallow-format plates) |
| Carryover | <9 ppm with optional multi-wash and needle seat backflush |
| Sample Path Material | Biocompatible (low-binding, inert surfaces) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Online Sample Manager |
| Instrument Type | HPLC Autosampler for Biopharmaceutical Applications |
| Maximum Sample Capacity | 432 vials (2 mL) |
| Minimum Injection Volume | 0.1 µL |
| Maximum System Pressure | 1300 bar |
| Temperature Control Range (Optional Integrated Thermostat) | 4–40 °C |
| Dilution Ratio | Up to 1:1000 |
| Sample Handling Modes | Flow-through injection, FEED (Fast Exchange and Dilution) injection, Retention mode with quenching and pre-processing capability |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Carryover | < 9 ppm |
| Temperature Control Range (Optional Integrated Chiller/Heater) | 4–40 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Sample Bottle Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 1300 bar |
| Injection Volume Range | Up to 1500 µL |
| Needle Wash Port | External surface rinse capability |
| Optional Integrated Column Oven | Temperature range 5–80 °C above ambient, accommodates two columns up to 30 cm length |
| Optional Integrated Sample Thermostat | Temperature control from 4–40 °C |
| Internal System Volume | Minimized design with bypass mode available |
| Overlapped Run/Injection Cycle | Enabled for throughput optimization |
| Programmable Sequence Logic | Supports pre-injection sample conditioning and advanced scheduling |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7650A |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 50 vials |
| Syringe Options | 250 µL and 500 µL |
| Injection Modes | Single and Multi-injection |
| Priority Sample Insertion | Supported |
| Sample Overlap Capability | Yes |
| Needle Alignment | Fully Automated |
| Needle Illumination | Integrated LED lighting for visual verification and method development |
| Injection Technique | Fast, low-discrimination liquid-phase injection optimized for external standard calibration |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7693A |
| Instrument Type | Gas Chromatography Autosampler |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7696A |
| Pricing | Upon Request |
| Instrument Type | Gas Chromatography (GC) Autosampler-Integrated Offline Sample Preparation System |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 7697A |
| Instrument Type | Gas Chromatography Headspace Sampler |
| Maximum Sample Capacity | 12 vials (standard configuration) |
| Sample Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Temperature Control Range (Transfer Line) | 35–250 °C (off to 250 °C) |
| Temperature Control Range (Valve & Loop) | 35–210 °C (off to 210 °C) |
| Temperature Control Range (Oven/Chamber) | 35–210 °C (off to 210 °C) |
| Pressure Control | Electronic Pressure Control (EPC) for valve and loop |
| Leak Detection | Automated vial leak check during pressurization |
| Operating Modes | Single Extraction, Multiple Headspace Extraction (MHE), Multiple Headspace Concentration (MHC) |
| MHE/MHC Cycles | Up to 100 cycles per vial |
| Method Development Support | Cross-platform method conversion and rapid re-optimization |
| Software Compatibility | Agilent OpenLab CDS, Agilent MassHunter, Waters Empower™ 2/3 |
| Barcode Reader | Integrated for sample tracking |
| Carrier Gas Options | Helium, Nitrogen, Hydrogen (H₂-safe design) |
| Peak Area Reproducibility | <1.5% RSD (standard mode) |
| Interfacing | Direct GC inlet coupling via transfer line interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Switzerland |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | PAL3 Series 2 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity (2 mL vials) | up to 1458 (160 cm configuration) |
| Sample Capacity (10/20 mL vials) | up to 405 (160 cm configuration) |
| Compatible GC Platforms | Agilent 8890, 8860, Intuvo 9000, 7890, 7820 |
| Compatible Software | OpenLab CDS, MassHunter, ChemStation, EZChrom |
| Supported Sampling Modes | Liquid Injection, Static/Dynamic Headspace, SPME (Fiber & Arrow), RTC Tool Exchange |
| Integrated Sample Prep Functions | Dilution, Solvent Addition, Stirring, Centrifugation, Washing, Temperature-Controlled Handling |
| Consumables Intelligence | RFID/NFC-enabled smart chips for traceable usage history and automated reporting |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Markes International (OEM for Agilent) |
| Instrument Type | Thermal Desorption Autosampler for Gas Chromatography |
| Compatibility | Fully Integrated with Agilent GC and GC/MS Systems |
| Carrier Gases | Hydrogen, Helium, Nitrogen |
| Sample Capacity | Up to 100 Sorbent Tubes |
| Automation Mode | Stacked Tube Processing |
| Gas Configuration Options | 14-channel, 4-channel, or 3-channel online gas manifold |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model Series | Lumin, AQUATek 100, Atomx |
| Instrument Type | Gas Chromatography (GC) Purge-and-Trap Sample Introduction System |
| Compliance | Designed for ASTM D5024, D6227, EPA Methods 502.2, 524.2, 624, 8260D, and ISO 15681-2 |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM/ODM Producer |
| Valve Body Material | SUS316L / Alloy N60 / Hastelloy C / Hastelloy B |
| Rotor Material | PEEK |
| Max. Pressure (Gas) | 0.7 MPa |
| Max. Pressure (Liquid) | 3 MPa |
| Max. Operating Temperature | 250 °C |
| Flow Path Bore | 0.4 mm / 0.75 mm |
| Port Thread | 10-32 UNF Internal |
| Actuation | Electric (24 VDC / 2.5 A) or Pneumatic |
| Communication Interfaces | RS232, RS485, Digital I/O |
| Extended Stem Options | 2", 3", 4" |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AGS Valve Manifold Controller |
| Pricing | Upon Request |
| Brand | AIGIS |
|---|---|
| Model | Multi-Position Multi-Port Selection Valve Series |
| Valve Types | Inlet Valve, Injection Valve, Column Positioning Valve, Bypass Valve, Fraction Collection Valve |
| Body Material | PEEK / SUS316L |
| Max Operating Pressure | 4.0 MPa |
| Flow Range | 0–300 mL/min |
| Port Configurations | 1–6 positions, 4–14 ports |
| Internal Bore Options | 0.75 mm, 1.0 mm, 1.5 mm, 3.0 mm, 3.2 mm, 4.0 mm |
| Compliance | Designed for GLP/GMP-compliant chromatography workflows |
| Origin | Fujian, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | GC Autosampler |
| Model | BKQ-20 |
| Sample Vial Capacity | 12 mL |
| Maximum Vial Count | 196 (14 × 14 array) |
| Positioning Accuracy | ±0.01 mm |
| Power Input | AC 220 V |
| Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| GC Synchronization | Triggered via TTL/relay signal |
| Vacuum Reconditioning | Integrated for vial reuse |
| Communication Interfaces | RS-232, USB, optional Ethernet |
| Sample Injection Modes | Headspace, direct gas loop, split/splitless compatible |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016 |
| Sample Capacity | 160 × 2 mL vials |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 10 µL |
| Positioning Accuracy | ±0.3 mm |
| Motion Architecture | Vertical tower with optional expansion tray |
| Needle Wash Cycles | 99 internal rinses per injection |
| Replicate Injections per Vial | up to 99 |
| Injection Speed | configurable down to 0.1 s per injection |
| Injection Depth Range | –2 to 35 mm |
| Sample Tray Encoding | absolute-position optical encoder |
| Communication Protocols | Modbus RTU, USB 2.0, TTL I/O (compatible with major GC vendors) |
| Operating Temperature | –20 °C to 50 °C |
| Storage Temperature | –40 °C to 70 °C |
| Relative Humidity (operating) | 10–90% RH non-condensing |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3016B |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 160 positions |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volumes | 0.5, 1, 5, 10, 25, 50, and 500 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion System | XYZ three-axis robotic arm |
| Needle Wash Cycles | up to 99 |
| Re-injection Repetitions | up to 99 |