Multifunctional Autosampler
Filter
Showing 61–90 of 145 results
| Brand | Cleket |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | AS-3901AS |
| Instrument Type | GC Autosampler |
| Max Injection Volume | 500 µL |
| Min Injection Volume | 0.1 µL |
| Quantitative Loop Volumes | 1, 5, 10, 25, 50, 100, 250, 500 µL (selectable) |
| Positioning Accuracy | < 0.3 mm |
| Motion Mechanism | Rotary Carousel |
| Needle Wash | Internal & External Wall Cleaning, Unlimited Cycles |
| Repeat Injection Capability | Unlimited |
| Brand | Cleket |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AS-3901ASH |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 160 positions |
| Minimum Injection Volume | 0.1 µL |
| Loop Volume | 500 µL |
| Positioning Accuracy | 0.1 mm |
| Motion Mechanism | Turret-style rotary motion |
| Needle Wash Mode | Internal and external wall wash, programmable cycles |
| Repeat Injection Capability | Unlimited |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HSTD |
| Instrument Type | Multifunctional Autosampler for GC Sample Introduction |
| Maximum Sample Capacity | 128 × 10 mL headspace vials |
| Positioning Accuracy | < 0.3 mm |
| Sampling Needle Cleaning Method | High-Temperature Carrier Gas Reverse Purge |
| Purge Function | Reverse Purge |
| Integrated Filtration Module | Yes |
| Sampling Pathway | Dual-Channel — Static/Dynamic Extraction with Continuously Adjustable Injection Volume |
| Brand | ColinTech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSTD 4020 |
| Instrument Type | Multifunctional GC Autosampler |
| Maximum Sample Capacity | 40 positions (Headspace) + 20 positions (Thermal Desorption) |
| Sample Processing Temperature Range | Ambient to 180 °C |
| Detection Limit for Vinyl Chloride in Water | 0.05 µg/L |
| Compliant Standards | HJ 639–2012, HJ 605–2011, HJ 713–2014 |
| GC Interface | Single unified inlet port with software-selectable mode switching |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic Instrument |
| Model | ASF 5110 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | HPLC Autosampler & Fraction Collector |
| Sample Injection Volume | 0–100 µL (expandable) |
| Injection Precision | RSD < 0.5% (partial-loop), < 0.3% (full-loop), < 1.0% (needle-injection) |
| Linearity | > 0.999 |
| Carryover | < 0.01% |
| Fraction Collection Response Time | 30 ms |
| Collection Vial Capacity | up to 4 mL |
| Compatible Tray Formats | 120-well, 96-well, and 72-well microplates |
| Collection Mode | Time-based fractionation table |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC Autosampler |
| Model | S3100 |
| Price Range | USD 7,000–14,000 (FOB China) |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 120 positions |
| Injection Volume Range | 0–100 µL |
| Injection Precision | RSD < 0.3% (full-loop mode) |
| Power Supply | AC 220 V ±10%, 50 Hz / 30 W |
| Dimensions (L×W×H) | 540 × 400 × 300 mm |
| Weight | 23 kg |
| Brand | EXFORMMA |
|---|---|
| Origin | Hong Kong |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | ARCUS 5 |
| Instrument Type | HPLC/UHPLC Autosampler |
| Sample Capacity | Up to 108 × 2 mL vials (configurable with 10 mL, 4 mL, or 96-well PCR plates) |
| Max Operating Pressure | 40 MPa |
| Injection Volume Range | 0.1–1000 µL (standard configuration: 0.1–120 µL) |
| Syringe Volume | 200 µL (resolution: 0.1 µL) |
| Sampling Modes | Full-loop, Partial-loop, and Needle-into-loop (NIL) / Zero-dead-volume sampling |
| Vial Height Limit | ≤52 mm (including septum and cap) |
| Pump Lifetime | ≥1,000,000 injections |
| Compliance | Designed for GLP/GMP environments |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FL1092C |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 150 positions (with optional extended sample tray) |
| Optional Modules | Integrated internal standard addition, programmable heating/stirring, barcode scanning, full-tray temperature control (via recirculating water bath) |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas Chromatography Autosampler |
| Model | FL1092T |
| Sample Capacity | 16 vials per tray |
| Configuration Options | Single-tower or dual-tower operation |
| Module Options | Vial agitation, temperature control (cooling/heating), barcode scanning |
| Compliance | Designed for integration with GC systems compliant with ISO/IEC 17025 laboratory practices and compatible with FDA 21 CFR Part 11–enabled data acquisition software |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PT800 |
| Instrument Type | Multifunctional Autosampler |
| Flow Control Precision | ±0.001 psi (EPC) |
| Sample Capacity | 96-position water/soil dual-mode autosampler |
| Trapping System | High-efficiency U-shaped trap with integrated spiral water removal |
| Sample Preservation | Optional refrigerated sample tray (4–10 °C) |
| System Inertness | Fully passivated flow path (inertized valves, tubing, and fittings) |
| Cleaning Protocol | Hot water and methanol purge cycles |
| Stirring | Integrated magnetic stirring for soil matrix enhancement |
| Software Interface | Modular workstation with guided workflow buttons |
| Compliance Support | Audit-trail ready |
| Brand | Golden Promise |
|---|---|
| Model | AHS-6890 |
| Type | Semi-Automatic Headspace Sampler |
| Sample Capacity | 12-position vial carousel |
| Vial Size | Standard 20 mL (customizable: 5 mL, 10 mL, 50 mL) |
| Sample Zone Temp Range | Ambient to 200 °C (1 °C increments) |
| Transfer Line Temp Range | Ambient to 160 °C (1 °C increments) |
| Valve & Loop Temp Range | Ambient to 160 °C (1 °C increments) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Carryover Reduction | Programmable purge flow and duration |
| Reproducibility | RSD < 3% (dependent on GC system performance and operator technique) |
| Dimensions (W×D×H) | 200 × 380 × 400 mm |
| Weight | ~20 kg |
| Control Interface | Microprocessor-based with LCD display, membrane keypad, and embedded time-programmable logic (8-step sequence, 9 stored methods) |
| GC Synchronization | TTL-compatible event triggering |
| Safety | Low-voltage heating circuitry for transfer lines |
| Brand | HAMILTON |
|---|---|
| Origin | USA |
| Model | 500 µL |
| Needle Type | Fixed-Needle, Standard |
| Volume Accuracy | ±1% (per ASTM D3747) |
| Needle Gauge | 22s |
| Hub Type | Luer Lock |
| Sterility | Non-sterile, Individually Packed |
| Compliance | ISO 8536-4, USP <381>, FDA 21 CFR Part 11 Ready (when used with compliant autosampler software) |
| Brand | HAMILTON |
|---|---|
| Origin | USA |
| Type | Gas-Tight Fixed-Needle Syringe |
| Volume | 250 µL |
| Application | Gas Chromatography (GC) Sample Introduction |
| Compliance | ASTM D4057, USP <621>, ISO/IEC 17025-aligned handling protocols |
| Needle | Stainless Steel, 23G × 2″ (0.64 mm × 50.8 mm), fixed |
| Barrel Material | Borosilicate glass with PTFE plunger seal |
| Accuracy | ±1% full scale (per ISO 8536-4) |
| Repeatability | CV < 0.5% (n = 10, standardized GC injection protocol) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-6D |
| Pricing | Available Upon Request |
| Flow Control | Mass Flow Controllers (MFCs) |
| Display | 7-inch Capacitive Touchscreen |
| Gas Path Materials | Passivated Stainless Steel Tubing & PTFE Tubing |
| Built-in Pump | Diaphragm Pump for Ambient-Pressure Gas Sampling |
| Dilution Range | 1:1 to 1:100 (customizable) |
| Output Channels | 6 Independent Concentration Ports |
| Operation Modes | Single-point or Multi-step Sequential Dilution |
| Method Storage | Onboard Method Library with Recall Function |
| Software Interface | Single- or Multi-channel Configuration Support |
| Brand | Shimadzu |
|---|---|
| Origin | Italy |
| Model | HT200H Headspace Autosampler |
| Sample Capacity | 40 positions (for 10 mL or 20 mL headspace vials) |
| Sample Heating Block | Simultaneous heating of up to 6 vials |
| Heating Temperature Range | 40–150 °C |
| Heating Time Range | 0–23 h 59 min |
| Agitation Duration | 0–99 min |
| Agitation Speed | Adjustable |
| Syringe Volume | Standard 2.5 mL, optional 5 mL |
| Minimum Injection Volume | 0.01 mL |
| Injection Flow Rate | 0.1–100 mL/min |
| Equilibration Delay | 0–60 s |
| Needle Temperature Control | 40–150 °C |
| Carrier/Purge Gas | Inert gas (N₂ or He) |
| Extraction Mode | Multiple Headspace Extraction (MHE), up to 15 cycles |
| Software Compatibility | HT-Comsoft-H and Clarity Chromatography Data Systems |
| Position Flexibility | Removable sample tray configurable for left- or right-side installation |
| Brand | HTA |
|---|---|
| Origin | Italy |
| Model | HT4150L |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 32 tubes (2 × 16-position racks) |
| Minimum Dispensing Volume | 0.1 mL |
| Quantitative Loop Volumes | 1 mL and 2.5 mL |
| Positioning Accuracy | < 0.2 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external wall rinsing |
| Repeat Injection Capability | Unlimited cycles |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APK2600 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 15 gas bags |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volume | Software-Controlled |
| Positioning Accuracy | <0.3 mm |
| Actuation Method | Pump-Driven Aspiration |
| Needle Wash Mode | Internal & External Wall Rinse |
| Repeat Injection Capability | Unlimited cycles per sample |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 16 positions |
| Motion Control | Fully Automated |
| Syringe Wash Capability | Unlimited wash cycles |
| Repeat Injection Capability | Unlimited injections per sequence |
| Purge Function | Not integrated |
| View Window | Not included |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GHD-ZY2001 |
| Instrument Type | Multifunctional Gas Transfer Sampler |
| Maximum Sample Transfers per Cycle | 1 |
| Minimum Transfer Volume | 200 mL |
| Adjustable Transfer Volume Range | ≥1000 mL (from 3 L SUMMA® canister) |
| Vacuum Pressure Range | −40 kPa to 0 kPa |
| Vacuum Control Accuracy | < ±0.5 kPa |
| Positioning Repeatability | < 0.5 mm |
| Motion Control | Motorized Automated Actuation |
| Tubing Material | PFA and PTFE |
| Check Valve Integrated | Yes |
| Structural Material | Electropolished Stainless Steel (316L) |
| Compliance | HJ 604–2017 |
| Compatible Canisters | 3 L, 6 L, and 15 L SUMMA®-type electropolished stainless steel canisters |
| Compatible Gas Bags | 200 mL and 300 mL Tedlar® or fluorinated ethylene propylene (FEP)-lined bags |
| Brand | HuaShengPuXin |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-6000 |
| Instrument Category | GC Autosampler with Cryogenic Trapping |
| Max Sample Capacity | 6 positions |
| Valve Injection System Temp Range | RT–220°C (1°C increments) |
| Transfer Line Temp Range | RT–240°C (1°C increments, low-voltage heating) |
| Desorption Temp Range | RT–350°C (1°C increments, >1000°C/min ramp rate) |
| Cryo-Trap Temp Range | −50°C to +50°C (1°C increments, solid-state electronic cooling) |
| Dimensions | 465 × 220 × 380 mm |
| Power Consumption | 500 W |
| Weight | ~20 kg |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AGS-30(60) |
| Instrument Type | Gas Chromatography Autosampler |
| Sampling Modes | Bag, Syringe, and Loop Injection (Optional) |
| Calibration | Fully Automated Multi-Point Dilution Calibration |
| Cleaning | Integrated Pre- and Post-Injection Tubing & Loop Purge |
| Control Interface | 7-inch Capacitive Touchscreen + Optional PC Remote Control (Synchronized GUI) |
| Gas Dilution | Programmable Proportional Mixing of Standard or Sample Gases |
| Compliance | Designed for ISO/IEC 17025-aligned QC labs and GLP-compliant environmental & industrial gas analysis workflows |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | JRS-86 |
| Control System | CPU-controlled |
| Sample Injection Volume Range | 100 µL to 50 mL |
| Injection Interval | 1–999 minutes |
| Maximum Number of Repetitive Injections | 99 |
| Compatible Systems | Integrated with JAI 9102 and 9103 Recirculating Preparative HPLC Units |
| Configuration | Rack-mounted, in-line installation at pump suction side |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | JSP-20 |
| Sample Capacity | 1–20 vials |
| Injection Volume Range | 0.1–5.0 mL |
| Injection Precision | CV ≤ 1% |
| Maximum Operating Pressure | 20 MPa |
| Injection Repetition | 1–99 times per vial |
| Sequence Programmability | 1–20 order |
| Maximum Run Time | 999 minutes |
| Wash Mode | Dual solvent/air flush |
| Vial Type | 5 mL screw-thread glass vials |
| Sealing Materials | Silicone and PTFE |
| Needle Design | Dual-side-port stainless steel needle |
| Power Supply | AC 100 V / 3 A |
| Control Interface | Touchscreen LCD panel |
| Dimensions (W×H×D) | 250 × 300 × 435 mm |
| Weight | 15 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AMTK Multifunctional HPLC Autosampler |
| Pricing | Available Upon Request |
| Sample Capacity | 120 × 2 mL vials (2 × 60-position racks) |
| Injection Volume Range | 0.1–1000 µL |
| Precision | RSD < 0.5% (full-loop & partial-loop modes) |
| Carryover | < 0.01% |
| Linearity | R² > 0.999 |
| Injection Modes | Full-loop, Partial-loop, Needle-Over-Loop (NOL), and Zero-Dead-Volume (ZDV) |
| Quantitative Loop Options | 20, 50, 100 (standard), 200, 500 µL |
| Syringe Pump Options | 100, 250 (standard), 1000 µL |
| Valve Switching Time | < 100 ms |
| Positioning Accuracy | < 0.3 mm (XYZ 3-axis stepper motor control) |
| Wash Protocol | Dual-wall (inner + outer needle) wash with unlimited cycles |
| Dimensions | 300 × 230 × 505 mm (L × H × W) |
| Power | AC 220 V, 50 Hz |
| Communication | LAN & RS-232 |
| Software | AMTK Chromatography Workstation |
| pH Compatibility | 1–14 |
| System Integration | Fully compatible with Agilent, Waters, Shimadzu, Thermo Fisher, PerkinElmer, Elite, and other HPLC/UHPLC/IC platforms |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Model | LH3000 |
| Instrument Type | HPLC Autosampler |
| X-axis Travel Range | 160–2800 mm (customizable) |
| Y-axis Travel Range | 70–670 mm (single arm) |
| Z-axis Height Range | 130–780 mm (fixed base height), max vertical stroke: 400 mm |
| Compliance | Designed for GLP/GMP environments |
| Brand | LabTech |
|---|---|
| Origin | Switzerland |
| Manufacturer | LabTech Instruments AG |
| Product Type | Multifunctional Autosampler for GC/GC-MS/LC/LC-MS |
| Core Techniques | Purge-and-Trap, Static/Dynamic Headspace, Solid-Phase Microextraction (SPME), Thermal Desorption, Pyrolysis, Large-Volume Injection, Gel Permeation Chromatography (GPC) Cleanup, µSPE, Vortex Mixing, Liquid-Liquid Extraction, Derivatization, Cap Piercing, Pipetting |
| Platform Compatibility | GC, GC-MS, LC, LC-MS/MS (vendor-neutral interface) |
| Structural Design | Modular, Rack-Mounted, Instrument-Integrated Platform |
| Configurable Footprint | 534 mm to 1600 mm linear rail length |
| Automation Level | Fully Unattended Operation with Inter-Module Tool Exchange |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo AS |
| Instrument Type | Liquid Chromatography Autosampler |
| Compliance | Designed for ASTM D4790, USP <621>, and ISO 17025-accredited laboratories |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 120 vials (3 trays), 105 vials under refrigeration |
| Injection Precision | <0.1% RSD @ 5 µL and @ 10 µL |
| Injection Volume Range | 0.1–100 µL (standard 250 µL loop) |
| Sample Temperature Control | Peltier-based cooling/heating, 0–60 °C in 1 °C increments |
| Vial Mixing/Heating | Pneumatic vortex mixer + heater per vial, 1 °C resolution |
| Dilution Accuracy | <1.0% RSD for 1:1000 dilution (10 µL → 1 mL) |
| Dispensing Accuracy | <0.2% RSD when adding 1 mL solvent externally |
| Method Storage | Protected memory file system |
| Communication Interface | RS-232 |
| Operating Environment | 10–40 °C, 5–95% RH (non-condensing) |
| Dimensions | 14.5" H × 16" W × 19.5" D |
| Weight | 35.2 lbs (base unit) |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | SCH-01 |
| Sample Capacity | 11 positions + 1 dedicated wash station |
| Maximum Sample Volume per Cup | 120 mL |
| Typical Sample Volume Range | 65–85 mL |
| Minimum Dispensing Volume | 5 µL |
| Positioning Accuracy | ±0.1 mm |
| Motion System | 3-axis robotic arm |
| Needle Wash Method | Solvent rinse + air-dry purge |
| Replicate Injections | Up to ≥5 injections per sample |
| Purge Function | Compressed air purge (post-injection and pre-aspiration) |
| Housing | Transparent acrylic enclosure (no dedicated observation window) |
| Filtration Module | Not integrated |
| Stirring Modes | Dual-mode — top-mounted and bottom-mounted magnetic stirring |
| Stirring Speed Range | 0–45 rpm |
| Display & Control | Integrated LCD panel with membrane keypad |
| Communication Interfaces | USB 2.0, RS-232 serial |
| Protocol Support | MODBUS RTU |
| Baud Rates | Configurable (9.6 kbps to 115.2 kbps) |
| Self-Diagnostic Capabilities | Built-in system check at power-on and runtime error detection |
| Firmware Upgradability | Field-upgradable via USB |
| Power Supply | 220 V ±10%, 50 Hz ±2% |
| Dimensions (L×W×H) | 525 × 310 × 270 mm |
| Weight | 7.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SCH-02 |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 24 positions |
| Minimum Injection Volume | 50 µL |
| Positioning Accuracy | ±0.1 mm |
| Actuation Method | Robotic Arm Drive |
| Needle Wash Mode | Automated Solvent Rinse (Integrated Wash Station with Dual-Solvent Capability) |
| Repeat Injection Cycles | 1–99 (Programmable) |
| Post-Injection Purge | Yes (Automatic Residue Blow-Off) |
| Compatible Sample Tray Configurations | 32-position × 50 mL |
| Stirring Function | Optional Top or Bottom Magnetic Stirring |
| Interface Options | USB + RS-232 |
| Communication Protocol | ASCII-based Command Set (Documented for Third-Party Integration) |