Multifunctional Autosampler
Filter
Showing 31–60 of 83 results
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016C |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 24–160 positions (standard 24, expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volume Range | 0.5–500 µL (user-selectable) |
| Positioning Accuracy | ±0.1 mm |
| Motion Architecture | Vertical Tower (Z-axis linear actuation) |
| Needle Wash | Internal & External Wall Rinse, Unlimited Cycles |
| Repeat Injection Capability | Unlimited (user-configurable) |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Per-Vial Injection Count | 1–99 |
| Maximum Time Interval Between Injections | 999 min |
| Viscosity Delay | 0–60 s |
| Pre-/Post-Insertion Dwell Time | 0–120 s |
| Needle Penetration Speed | Fast / Slow / Custom |
| Aspiration/Dispense Speed | Fast / Slow / Custom |
| Injection Modes | Conventional, Continuous, Sample+L1, Sample+L1+L2, PTV-compatible |
| Control Interface | TTL-triggered interval control, GC signal reverse-triggering, USB 2.0, Modbus RTU over RS-485 |
| Dual-Tower Injection Time Reproducibility | < 1 ms |
| Barcode Scanning Support | Yes |
| Sample Temperature Control | Optional integrated cooling/heating module |
| Operating Temperature | −20 °C to +50 °C |
| Storage Temperature | −40 °C to +70 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Storage Humidity | 5–90% RH |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3117 |
| Sample Capacity | 156-position 2 mL vial tray + 15-position auxiliary tray |
| Minimum Injection Volume | 0.01 µL |
| Quantitative Loop Volume | 10 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion Mechanism | Turret-based |
| Needle Wash | Internal Wall Rinse |
| Repeat Injection Cycles | Up to 99 |
| Operating Temperature Range | −20 °C to 50 °C (operational), −40 °C to 70 °C (storage) |
| Relative Humidity Range | 10–90% RH (operational), 5–90% RH (storage) |
| Communication Protocol | Modbus RTU |
| I/O Interface | Configurable digital I/O for GC synchronization |
| Control Modes | Interval-triggered, signal-triggered (TTL/relay), and full PC-based remote control |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3117B |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 20 positions (expandable to 156) |
| Minimum Injection Volume | 0.1 µL |
| Positioning Accuracy | < 0.1 mm |
| Motion Mechanism | Turret-based |
| Needle Wash Mode | Selectable (pre- and/or post-injection) |
| Repeat Injection Count | Up to 99 cycles per sample |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 88 positions |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volumes | 1 mL / 2 mL / 3 mL |
| Positioning Accuracy | <0.1 mm |
| Sampling Mechanism | Quantitative Loop Injection |
| Needle/Line Cleaning | Fully Automated |
| Repeat Injection Cycles per Sample | Up to 99 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519-XS |
| Instrument Type | Gas Chromatography (GC) Gas Bag Autosampler |
| Maximum Sample Volume | 5 mL |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volume Range | 0.05–5 mL |
| Positioning Accuracy | RSD < 0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Method | PC-based host software control |
| Needle/Line Cleaning | Integrated pneumatic line purge with inert gas |
| Repeat Injection Count | 1–99 times per sample |
| Sample Tray Capacity | 11 / 28 / 40 positions (expandable to 88) |
| Quantitative Loop & Line Heating Range | Ambient to 150 °C |
| Sample & Standard Dilution Ratio | Up to 1:200 (customizable) |
| Sampling Pump | Max flow 6 L/min |
| Sampling Time Parameters | Max draw time 99 s, max equilibration time 99 s, max purge time 600 s |
| Tubing Material | PTFE |
| Valve Actuator | PEEK body with PI (polyimide) rotor |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | GAS-3529A-16 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sampling Rate | 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Minimum Sample Volume | 1 mL (configurable to 2 mL or 3 mL) |
| Quantitative Loop Volume | 1 mL / 2 mL / 3 mL (user-selectable) |
| Positioning Accuracy | RSD < 1% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Sample Capacity | 16 positions (base unit) |
| Dimensions (L×W×H) | 40 × 50 × 37 cm (height increases by 15 cm per added module) |
| Cleaning | Automated syringe needle path flush + quantitative loop purge + gas bag rinse |
| Valve Actuation | PEEK body with PI (polyimide) rotor |
| Tubing Material | PTFE and PEEK only |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Compliance | Meets GB/T 33642–2017 (Chinese national standard for gas sampling systems in GC applications) |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3539 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Positions | 88 |
| Min Sample Positions | 16 |
| Quantitative Loop Volumes | 1 mL, 2 mL, 3 mL (selectable) |
| Positioning Accuracy | RSD <0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Interface | PC-based upper-computer software |
| Needle & Loop Cleaning | Automated in-line cleaning of sampling lines, quantitative loops, gas bags, and sample pathways during GC coupling |
| Repeat Injection Capability | Unlimited cycles per sample |
| Operating Temperature Range | −20 °C to 50 °C |
| Storage Temperature Range | −40 °C to 70 °C |
| Humidity Range (Operating) | 10–90% RH |
| Humidity Range (Storage) | 5–90% RH |
| Syringe Capacity | 100 mL |
| Gas Bag Capacity | 500 mL or 1 L |
| Minimum Injection Volume | 50 µL (loop-dependent) |
| Maximum Injection Volume | 5 mL (loop-dependent) |
| Max Purge Time | 600 s |
| Max Draw Time | 99 s |
| Max Equilibration Time | 99 s |
| Max Interval Between Injections | 999 min |
| Quantitative Loop Heating Range | Ambient to 150 °C |
| Sample Pathway Heating Range | Ambient to 150 °C |
| Calibration Standard Points | Up to 8 programmable concentration levels |
| Cleaning Cycles per Step | 1–15 |
| Sampling Pump Flow Rate | Up to 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Dimensions (L×W×H) | 900 × 600 × 900 mm |
| Tubing Material | Silanized stainless steel |
| Valve Body | PEEK |
| Valve Core | PI (Polyimide) |
| Sample Port Flexibility | Dual-mode — gas bag or syringe injection per port |
| High-Concentration Detection Logic | Auto-halt + GC oven ramp initiation upon detection of saturation-level analyte signals |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LAS-3622 |
| Instrument Type | HPLC Autosampler |
| Max Sample Capacity | 200 positions |
| Minimum Injection Volume | 0.1 µL–2 mL |
| Loop Volumes | 50 µL, 100 µL, 250 µL, 1000 µL |
| Positioning Accuracy | <1% RSD at 1 µL, <0.5% RSD at 5 µL, <0.3% RSD at 10 µL |
| Sampling Mechanism | Loop-based injection |
| Needle Wash Modes | Automated line purge, bubble removal, pre-injection wash, post-injection wash |
| Repeat Injection Capability | Unlimited cycles per sample |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-AGS-36 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 132 positions |
| Minimum Injection Volume | 1 mL |
| Quantitative Loop Volume | 1 mL |
| Sample Tray Configuration | 36-position base (expandable in 12-position modules) |
| Compatible Sampling Devices | Gas-tight syringes and Tedlar®/aluminized gas bags |
| Tubing Material | PTFE |
| Valve Body | PEEK |
| Valve Core | Polyimide (PI) |
| Carrier Gas Line Purge Flow Rate | Up to 0.5 L/min |
| Injection Precision | R² ≥ 0.9999 for total hydrocarbons and methane peak areas across five replicate injections |
| Dimensions (L×W×H) | 450 × 500 × 430 mm |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-AS-24 |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 24 positions (expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Maximum Injection Volume | 250 µL |
| Replicate Injections per Vial | up to 99 |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Method Storage | up to 20 methods |
| Needle Wash Cycles | up to 99 |
| Pump Draw Cycles | up to 99 |
| Viscosity Delay | 0–60 s |
| Dwell Time Pre-/Post-Insertion | 0–120 s |
| Injection Timing Reproducibility (Dual-Tower Mode) | < 1 ms |
| Communication Interfaces | Modbus RTU, USB 2.0 |
| Operating Temperature | −20 °C to 50 °C |
| Storage Temperature | −40 °C to 70 °C |
| Operating Humidity | 10–90% RH |
| Storage Humidity | 5–90% RH |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | APL-FHS 300 |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 180-position liquid tray / 70-position headspace tray / 70-position SPME tray |
| Minimum Liquid Injection Volume | 0.01 µL |
| Motion Control | XYZ three-axis precision positioning |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AS3000 |
| Pricing | Available Upon Request |
| Brand | Otisence |
|---|---|
| Origin | Tianjin, China |
| Model | ASL-500 Autosampler & Fraction Collector |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 90 × 12.5 mm test tubes OR 96-well / 384-well microplates |
| Minimum Injection Volume | 10 µL |
| Flow Delivery Range | 10 µL to 100 mL via Peristaltic Pump |
| User Interface | 7-inch color TFT touchscreen with method storage |
| Cleaning & Drying | Automated wash-rinse-dry cycles for cuvettes, flow cells, syringe needles, and fluidic lines |
| Compliance | Designed for integration with UV-Vis spectrophotometers, protein analyzers, and kinetic assay systems |
| Brand | Autosens |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | API-1 |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 60 × 2 L vials |
| Minimum Injection Volume | 0.1 µL |
| Loop Volume | 100 µL |
| Positioning Accuracy | < 0.3 mm |
| Motion Axes | XYZ three-dimensional |
| Needle Wash Mode | Internal & external wall cleaning |
| Repeat Injection Capability | Unlimited cycles |
| Pressure Range | 0–75 kPa (continuously adjustable) |
| Pressure Display | 2-digit LED, ±5 kPa accuracy |
| Flow Rate (Pump) | 8 L/min |
| Timing Range | 0.1–99.9 s |
| Timer Resolution | 0.1 s |
| Dimensions (H×W×D) | 180 × 94 × 260 mm |
| Waste Bottle Capacity | 2000 mL per bottle |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | ~30 VA |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | 960A |
| Instrument Type | Multifunctional Autosampler |
| Sample Introduction Ports | 16-position |
| Compatible Sample Containers | Vacuum Sampling Canisters & Tedlar® Bags |
| Entire Gas Path Heating | Yes (Uniform Temperature Control) |
| Gas Path Surface Treatment | Fused Silica Inert Coating (Verified via Inertness Testing) |
| Multi-Position Injection Valve | Bidirectional Rotational Actuation |
| Flow Path Optimization | Minimized Contact Time Between Sample and Valve Core |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 960SN |
| Instrument Type | Multifunctional High-Pressure Autosampler |
| Pricing | Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BCT950M |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 5–1000 mL (standard configuration) |
| Sampling Mechanism | Canister-based automated sampling |
| Sample Loop Volume Range | 0.1 µL – 30 mL |
| Transfer Line Length | < 0.5 m |
| Transfer Line Max Temperature | > 200 °C |
| Sample Path Surface Treatment | Deactivated fused-silica throughout |
| Focusing Trap | Integrated independent cryo-focusing trap for secondary focusing of loop- or trap-desorbed analytes |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ATS-051 |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Channels | 5 |
| Wash Channel | 1 |
| Loop Volumes | 1 mL, 10 mL, 25 mL |
| Injection Volume Range | 1–25 mL |
| Wash Volume | 5 mL (programmable wash modes + manual override) |
| Language Interface | English |
| Operating Temperature | 20–35 °C |
| Dimensions (L×W×H) | 361 × 208.5 × 344.4 mm |
| Weight | 11.4 kg |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic Instrument |
| Model | ASF 5110 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | HPLC Autosampler & Fraction Collector |
| Sample Injection Volume | 0–100 µL (expandable) |
| Injection Precision | RSD < 0.5% (partial-loop), < 0.3% (full-loop), < 1.0% (needle-injection) |
| Linearity | > 0.999 |
| Carryover | < 0.01% |
| Fraction Collection Response Time | 30 ms |
| Collection Vial Capacity | up to 4 mL |
| Compatible Tray Formats | 120-well, 96-well, and 72-well microplates |
| Collection Mode | Time-based fractionation table |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC Autosampler |
| Model | S3100 |
| Price Range | USD 7,000–14,000 (FOB China) |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 120 positions |
| Injection Volume Range | 0–100 µL |
| Injection Precision | RSD < 0.3% (full-loop mode) |
| Power Supply | AC 220 V ±10%, 50 Hz / 30 W |
| Dimensions (L×W×H) | 540 × 400 × 300 mm |
| Weight | 23 kg |
| Brand | EXFORMMA |
|---|---|
| Origin | Hong Kong |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | ARCUS 5 |
| Instrument Type | HPLC/UHPLC Autosampler |
| Sample Capacity | Up to 108 × 2 mL vials (configurable with 10 mL, 4 mL, or 96-well PCR plates) |
| Max Operating Pressure | 40 MPa |
| Injection Volume Range | 0.1–1000 µL (standard configuration: 0.1–120 µL) |
| Syringe Volume | 200 µL (resolution: 0.1 µL) |
| Sampling Modes | Full-loop, Partial-loop, and Needle-into-loop (NIL) / Zero-dead-volume sampling |
| Vial Height Limit | ≤52 mm (including septum and cap) |
| Pump Lifetime | ≥1,000,000 injections |
| Compliance | Designed for GLP/GMP environments |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FL1092C |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 150 positions (with optional extended sample tray) |
| Optional Modules | Integrated internal standard addition, programmable heating/stirring, barcode scanning, full-tray temperature control (via recirculating water bath) |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas Chromatography Autosampler |
| Model | FL1092T |
| Sample Capacity | 16 vials per tray |
| Configuration Options | Single-tower or dual-tower operation |
| Module Options | Vial agitation, temperature control (cooling/heating), barcode scanning |
| Compliance | Designed for integration with GC systems compliant with ISO/IEC 17025 laboratory practices and compatible with FDA 21 CFR Part 11–enabled data acquisition software |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PT800 |
| Instrument Type | Multifunctional Autosampler |
| Flow Control Precision | ±0.001 psi (EPC) |
| Sample Capacity | 96-position water/soil dual-mode autosampler |
| Trapping System | High-efficiency U-shaped trap with integrated spiral water removal |
| Sample Preservation | Optional refrigerated sample tray (4–10 °C) |
| System Inertness | Fully passivated flow path (inertized valves, tubing, and fittings) |
| Cleaning Protocol | Hot water and methanol purge cycles |
| Stirring | Integrated magnetic stirring for soil matrix enhancement |
| Software Interface | Modular workstation with guided workflow buttons |
| Compliance Support | Audit-trail ready |
| Brand | HTA |
|---|---|
| Origin | Italy |
| Model | HT4150L |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 32 tubes (2 × 16-position racks) |
| Minimum Dispensing Volume | 0.1 mL |
| Quantitative Loop Volumes | 1 mL and 2.5 mL |
| Positioning Accuracy | < 0.2 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external wall rinsing |
| Repeat Injection Capability | Unlimited cycles |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo AS |
| Instrument Type | Liquid Chromatography Autosampler |
| Compliance | Designed for ASTM D4790, USP <621>, and ISO 17025-accredited laboratories |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 120 vials (3 trays), 105 vials under refrigeration |
| Injection Precision | <0.1% RSD @ 5 µL and @ 10 µL |
| Injection Volume Range | 0.1–100 µL (standard 250 µL loop) |
| Sample Temperature Control | Peltier-based cooling/heating, 0–60 °C in 1 °C increments |
| Vial Mixing/Heating | Pneumatic vortex mixer + heater per vial, 1 °C resolution |
| Dilution Accuracy | <1.0% RSD for 1:1000 dilution (10 µL → 1 mL) |
| Dispensing Accuracy | <0.2% RSD when adding 1 mL solvent externally |
| Method Storage | Protected memory file system |
| Communication Interface | RS-232 |
| Operating Environment | 10–40 °C, 5–95% RH (non-condensing) |
| Dimensions | 14.5" H × 16" W × 19.5" D |
| Weight | 35.2 lbs (base unit) |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | SCH-01 |
| Sample Capacity | 11 positions + 1 dedicated wash station |
| Maximum Sample Volume per Cup | 120 mL |
| Typical Sample Volume Range | 65–85 mL |
| Minimum Dispensing Volume | 5 µL |
| Positioning Accuracy | ±0.1 mm |
| Motion System | 3-axis robotic arm |
| Needle Wash Method | Solvent rinse + air-dry purge |
| Replicate Injections | Up to ≥5 injections per sample |
| Purge Function | Compressed air purge (post-injection and pre-aspiration) |
| Housing | Transparent acrylic enclosure (no dedicated observation window) |
| Filtration Module | Not integrated |
| Stirring Modes | Dual-mode — top-mounted and bottom-mounted magnetic stirring |
| Stirring Speed Range | 0–45 rpm |
| Display & Control | Integrated LCD panel with membrane keypad |
| Communication Interfaces | USB 2.0, RS-232 serial |
| Protocol Support | MODBUS RTU |
| Baud Rates | Configurable (9.6 kbps to 115.2 kbps) |
| Self-Diagnostic Capabilities | Built-in system check at power-on and runtime error detection |
| Firmware Upgradability | Field-upgradable via USB |
| Power Supply | 220 V ±10%, 50 Hz ±2% |
| Dimensions (L×W×H) | 525 × 310 × 270 mm |
| Weight | 7.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SCH-02 |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 24 positions |
| Minimum Injection Volume | 50 µL |
| Positioning Accuracy | ±0.1 mm |
| Actuation Method | Robotic Arm Drive |
| Needle Wash Mode | Automated Solvent Rinse (Integrated Wash Station with Dual-Solvent Capability) |
| Repeat Injection Cycles | 1–99 (Programmable) |
| Post-Injection Purge | Yes (Automatic Residue Blow-Off) |
| Compatible Sample Tray Configurations | 32-position × 50 mL |
| Stirring Function | Optional Top or Bottom Magnetic Stirring |
| Interface Options | USB + RS-232 |
| Communication Protocol | ASCII-based Command Set (Documented for Third-Party Integration) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Instrument |
| Model | 858 |
| Instrument Category | Liquid Chromatography Autosampler |
| Interface | USB |
| Sample Rack Recognition | >30 types |
| Sample Vial Capacity | 0.5–500 mL |
| Integrated Fluid Handling | Dual-channel peristaltic pump (optional), non-metallic 6-port valve (optional), 800 Dosino dispensers |
| Online Sample Preparation Capabilities | Inline ultrafiltration, dialysis, matrix elimination, neutralization, cation removal, preconcentration, calibration correction, probe sampling |
| Software Control | MagIC Net™ |