| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | X-Ray Real-Time Imaging System |
| Pricing | Available Upon Request |
| Brand | AoLong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | XYG-1610 |
| Pricing | Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | YX-2C |
| Price Range | USD 140,000 – 280,000 |
| Input Power | AC 220 V, 50 Hz, 0.5 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −5° to +55°, 2θ = −10° to +110° |
| Mechanical Angular Resolution | 1° (on scale ring for both θ and 2θ) |
| Digital Display Resolution | 10 arcseconds |
| Angular Accuracy | ±30 arcseconds |
| Slit Apertures | 4′, 5′, 6′ |
| Beam Shutter | Manual |
| Display Format | Degrees, Minutes, Seconds |
| Angle Setting | Programmable digital angle preset |
| Dimensions (L×W×H) | 1140 × 650 × 1030 mm |
| Weight | 150 kg |
| Brand | Aolong |
|---|---|
| Cooling Capacity | 4000 W |
| Flow Rate | 14 L/min |
| Power Supply | Single-phase 220 V ±10%, 50/60 Hz |
| Current Draw | 2.3 A |
| Noise Level | 58 dB(A) at 1 m |
| Operating Temperature | +5 °C to +35 °C |
| Storage Temperature | −25 °C to +70 °C (oil-free) |
| Relative Humidity | 20–80% RH (non-condensing) |
| Maximum System Pressure | 60 bar |
| Origin | Liaoning, China |
| Manufacturer | Aolong (OEM producer) |
| Brand | Astera |
|---|---|
| Origin | Guangdong, China |
| Model | XG5120 / XG5130 |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current (Software-Limited) | 89 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Field of View | 2″ / 4″ |
| Spatial Resolution | 75 / 110 lp/cm |
| X-CCD Resolution | 1024 × 1024 pixels |
| Geometric Magnification | 12×–48× |
| Repeatability Accuracy | ±40 µm |
| Radiation Dose Rate | ≤1 µSv/hr (at any accessible surface) |
| System Dimensions | 2800 × 1550 × 1850 mm |
| Weight | ~2000 kg |
| Power Supply | AC 220 V, 10 A |
| Operating Environment | 22 ± 3 °C, 50 ± 10% RH |
| Computing Platform | 22″ widescreen LCD, Intel Core i3, 2 GB RAM, 500 GB HDD |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Model | XG5 |
| Price Range | USD 70,000 – 140,000 |
| Category | X-ray Radiographic Inspection System for Electronics Assembly |
| Detection Principle | Transmission X-ray Imaging (2.5D) |
| Motion Control | CNC-programmable XYZ-axis movement of X-ray source and image intensifier |
| Image Acquisition | Real-time digital radiography with software-based measurement and pass/fail classification |
| Compliance | Designed to support IPC-A-610, IPC-J-STD-001, and ISO 9001 quality audit workflows |
| Software | Proprietary automated inspection suite with measurement tools (linear distance, circle diameter, concentricity, point-to-center), navigation mapping, and DICOM-compatible image export |
| Brand | Astroda |
|---|---|
| Model | XG5100 |
| Application | In-line/Off-line Automated Radiographic Inspection of Polymer Pouch-Type Li-ion Cells and Sealed Battery Packs |
| X-ray Tube Voltage | Up to 110 kV |
| X-ray Tube Current | Up to 450 µA |
| Focal Spot Size | 5 µm |
| Detector Type | Line-Scan CCD/CMOS Array |
| Sensitive Area | 235 mm × 13 mm |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥25 parts per minute (ppm) |
| False Positive Rate | ≤2% |
| Miss Detection Rate | 0.0% |
| Overall Yield Compliance Rate | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr at any accessible surface |
| Cooling Method | Forced-Air Cooled X-ray Source |
| Safety Certification | Compliant with IEC 61000-6-4, IEC 61000-6-2, and GBZ 126–2011 (China National Standard for Radiation Protection in Industrial X-ray Equipment) |
| Brand | Astroda |
|---|---|
| Model | XG5120 |
| Origin | Guangdong, China |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (per IEC 61331-1 & FDA 21 CFR §1020.40) |
| Throughput | ≥30,000 units/day |
| Reconfiguration Time | 0.5–2 h |
| Compliance | CE, ISO 13485 (for medical device manufacturing support), GB/T 18871-2002, IEC 62495 |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XG5130 |
| Pricing | Available Upon Request |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-4-3 & IEC 62471) |
| Brand | Astroda |
|---|---|
| Model | XG5200D |
| X-ray Tube Voltage | Up to 110 kV |
| X-ray Tube Current | Up to 450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Image Intensifier Field of View | 4″ / 6″ |
| Spatial Resolution | 80 lp/cm |
| Camera Resolution | 752 × 480 pixels |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥6 parts per minute (at non-tab corner regions) |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with international radiation safety standards) |
| Brand | Astroda |
|---|---|
| Model | XG5300/XG5310 |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA (software-limited to 89 µA) |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Field of View | 2″ / 4″ |
| Spatial Resolution | 75 / 110 lp/cm |
| X-CCD Resolution | 1024 × 1024 pixels |
| Repeatability Accuracy | ±40 µm |
| Throughput | ≥60 PPM |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Overall Yield Rate | ≥99.5% |
| Radiation Dose Rate | ≤1 µSv/hr (at any accessible surface) |
| Host Dimensions | 2500 × 1500 × 1700 mm |
| Power Supply | AC 380 V, 50 Hz |
| Operating Environment | 23 ±5 °C, ≤80% RH |
| Display | 22″ widescreen LCD |
| CPU | Intel Core i3 |
| RAM | 2 GB |
| Storage | 500 GB HDD |
| Brand | Astroda |
|---|---|
| Model | XG5600 |
| Origin | Guangdong, China |
| Detector Type | Flat-Panel Digital Radiography System |
| Max. Tube Voltage | 110 kV |
| Max. Tube Current | 450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air |
| Detector Active Area | 54 mm × 48 mm |
| Spatial Resolution | 20.8 lp/mm |
| Pixel Matrix | 2000 × 2249 / 1000 × 1124 |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥50 ppm |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (measured at 5 cm from enclosure surface) |
| Compliance | IEC 61000-6-3, IEC 61000-6-4, GBZ 126-2011, ANSI N43.3 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PAL-HIKARi 15 |
| Pricing | Available Upon Request |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MR-2.5GHz-300-XX-B |
| Optical Wavelength | 1550 nm |
| Dynamic Range | 0.1 V/m – 0.5 MV/m |
| Sensitivity | 100 mV/(m·Hz⁰·⁵) for f > 10 kHz |
| Response Gain | 60 μV/(V/m) (standard controller, low-frequency) |
| Orthogonal Component Suppression | >30 dB |
| Optical Insertion Loss | −12 dB |
| 3-dB Bandwidth | 2.5 GHz |
| Spatial Resolution | 300 µm |
| Sensor Dimensions | 3 mm × 25 mm (down to 1 mm length) |
| Pigtail Fiber | 1 m, PM, FC/APC |
| Laser Source | 1550 nm, 40 mW |
| Balanced Detector Bandwidth Options | 50 Hz–400 MHz or 1 MHz–2.5 GHz |
| Typical Low-Frequency Gain (System) | 5 μV/(V/m) |
| Rise Time | 0.25 ns (down to 6 ps) |
| Controller Dimensions | 200 × 275 × 40 mm |
| Weight | 1 kg |
| Output Interface | SMA-50 Ω |
| Power Supply | 110–220 VAC, 2 A |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Type | Fiber-Coupled Mach-Zehnder Electro-Optic THz Sensor |
| Core Material | Lithium Niobate (LiNbO₃) Thin-Film Waveguide |
| Operating Wavelength | 1550 nm |
| Detection Principle | Electro-Optic Sampling via Pockels Effect |
| Frequency Range | DC to >600 GHz (up to ~3 THz) |
| Spatial Resolution | <10 µm (diffraction-limited by 1550 nm probe beam) |
| Sensitivity | 1–10 V/(m·Hz⁰·⁵) |
| Dynamic Range | 10 V/m – 2 MV/m |
| Polarization Selectivity (Orthogonal Rejection) | >30 dB |
| Optical Insertion Loss | −12 dB |
| Input/Output Fiber | 3× PM Fiber, FC/APC |
| Effective Interaction Length | 600–6000 µm |
| Sensor Dimensions | 3 mm × 25 mm |
| Fiber Length | 1 m |
| Controller Model | L-1550-THz-D-400-B |
| Laser Source | 1550 nm, 10 mW, CW |
| Controller Output | SMA-50 Ω, ≤100 MHz bandwidth |
| Power Supply | 110–220 VAC, 50–60 Hz |
| Compliance | Designed for GLP-compliant THz-TDS systems |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | THz-Spectroscopic Imaging System for Cigarette Carton Inspection |
| Pricing | Available Upon Request |
| Brand | AZUP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EM10 |
| Price | USD 92,000 (FOB Beijing) |
| Brand | AZUP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | EM100 |
| Price | USD 112,000 (FOB Beijing) |
| Measurement Principle | Fourier Transform Infrared (FTIR)-based Directional-Hemispherical Reflectance (DHR) at 20° and 60° incidence angles |
| Spectral Range | 1–25 µm |
| Weight | <1.0 kg |
| Operating Modes | Handheld standalone mode & PC-controlled mode via USB/Bluetooth |
| Display | 5.0″ full-color capacitive touchscreen |
| User Interface | Graphical UI with guided workflow, ISO/IEC 17025-aligned measurement protocol sequencing |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SKYSCAN 1273 |
| X-ray Source Energy | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel, 3072 × 1944 pixels |
| Spatial Resolution | < 5 µm (3D) |
| Voxel Size | < 3 µm |
| Maximum Sample Dimensions | Ø300 mm × H500 mm, up to 20 kg |
| Field of View | Ø250 mm × H250 mm |
| Image Matrix | up to 4800 × 4800 pixels |
| Detector Output Speed | High-frame-rate acquisition enabled |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 2211 |
| X-ray Source | 20–190 kV, 4/10/25 W, sub-micron focal spot size, 5-position filter wheel |
| X-ray Target | Tungsten (standard) |
| Detector | 3 MP CMOS flat panel (1920 × 1536 px) or 11 MP cooled CCD (4032 × 2670 px) |
| Reconstruction Volume (CMOS) | up to 3776 × 3776 × 1160 px (dual offset mode) |
| Reconstruction Volume (CCD) | up to 8000 × 8000 × 2272 px (dual offset mode) |
| Spatial Resolution | down to 100 nm (detector-limited, geometry-dependent) |
| Sample Capacity | Ø204 mm × L200 mm, max. 25 kg |
| Sample Positioning | direct-drive air-bearing rotation stage with integrated piezo-driven micro-positioning (5.5 mm travel) |
| Reconstruct Time | 1 min 12 sec (600 projections, 2K × 2K × 1K) |
| Radiation Safety | <0.5 µSv/h at 10 cm from surface (measured at 190 keV, 4 W on target) |
| Power Supply | 100–130 V or 200–240 V AC, 50–60 Hz |
| Cooling & Air Supply | integrated closed-loop water chiller and oil-free air compressor with particle filters and desiccant dryer |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Reconstruction Volume | 14456 × 14456 × 2630 px (16 MP detector) or 11840 × 11840 × 2150 px (11 MP detector) |
| Spatial Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Density Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution Scientific CMOS Sensor |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | 2 µm |
| Density Resolution | <1% |
| X-ray Energy | 110 kV |
| Maximum Sample Dimensions | Ø110 mm × 300 mm (H) |
| Max Sample Weight | 5 kg |
| System Footprint | 1250 × 960 × 690 mm (L × D × H) |
| Precision Level | Nanoscale |
| Configuration | Modular Benchtop Micro-CT Platform |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution sCMOS Semiconductor Sensor |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | ≤2 µm (JIMA-verified) |
| System Architecture | Modular, Field-Upgradable |
| Brand | Caikon Optical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GCK-HD |
| Price | USD 4,900 (approx.) |
| Probe Diameter | 1.9–10 mm |
| Working Length | 54–600+ mm |
| Viewing Angle | 0°, 30°, 45°, 70°, or 90° (selectable) |
| Field of View | >70° |
| Imaging Sensor | Sony 1/1.8" CMOS |
| Resolution | 1920 × 1080 (2 MP) |
| Frame Rate | 60 fps |
| Output Interfaces | HDMI, VGA, DVI |
| Image Format | JPEG |
| Video Format | MKV, AVI |
| Storage | SD card |
| Illumination Options | Benchtop cold light source (XD-303), portable waist-mounted (KD-202), handheld LED (CK-202B), or desktop halogen (XD-301) |
| Operating Temperature | −10 °C to +50 °C |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model Series | ChiRad |
| Price Range | USD 140,000 – 280,000 (FOB) |
| Focal Spot Size | 5.5 mm |
| Radiation Beam Angle | 40° |
| Maximum Penetration | 30 mm Fe (Iron Equivalent) |
| Brand | COANTEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | C50 |
| Price Range | USD 1,400 – 2,800 (FOB) |
| Brand | COANTEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | C60 |
| Price Range | USD 700 – 1,400 |