Online Gas Chromatograph
Filter
Showing all 28 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGC2000 Series |
| Pricing | Upon Request |
| Brand | ABB |
|---|---|
| Origin | USA |
| Model | PGC5000 |
| Detection Principles | Gas Chromatography with Thermal Conductivity (TCD), Flame Ionization (FID), and Flame Photometric (FPD) Detection |
| Column Oven Configurations | Dual Intelligent Isothermal Zones (PGC5000B & PGC5000C) |
| Interface | 10.4″ SVGA Touchscreen HMI, Redundant Ethernet, USB, MODBUS RTU/TCP, Analog/Digital I/O |
| Compliance | Designed for SIL2-capable system integration per IEC 61511, compatible with FDA 21 CFR Part 11 audit trail requirements via optional software configuration |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC23 THC Analyzer |
| Detection Principle | Catalytic Combustion + Methane Conversion + Flame Ionization Detection (FID) |
| Display | 5.7″ QVGA Touchscreen |
| Calibration | Automated Zero/Range Calibration via Internal Solenoid Valves |
| Flow Control | Digital Electronic Mass Flow Controllers (MFCs) |
| Sample Flow Monitoring | Real-time Digital Flow Visualization & Alarm |
| Output Signals | 2 × Isolated, Passive 4–20 mA Outputs |
| Communication | RS-232 Serial Interface |
| Range Selection | 3 Auto-ranging Full-Scale Ranges |
| Compliance Support | Designed for ISO 8573-5, ASTM D6245, EPA Method 25A, and EN 15409-compliant installations |
| Safety Certification | ATEX / IECEx Zone 2 (optional), CE Marked |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaPRO9000 |
| Repeatability | ±0.1% |
| Detection Limit | 1 ppb |
| Detector Type | Helium Discharge Ionization Detector (DID) |
| Column Oven Temperature Range | Ambient to 450 °C with Independent Per-Column Thermal Control |
| Carrier Gas Requirement | Ultra-High-Purity Helium (99.999%) |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC STREAM 6000 |
| Detection Principle | High-Frequency Argon Discharge Detector (HFADD) |
| Measurement Range | 0–1 ppm / 0–10 ppm / 0–100 ppm |
| LOD | 10 ppb |
| Accuracy | ±1% of full scale |
| Zero Drift | <1% FS / Span Drift: <1% FS |
| Response Time (t₉₀) | 5 s |
| Display | 6.5" industrial-grade touchscreen |
| Signal Outputs | 2 × 4–20 mA, 1 × mV, VGA, USB |
| Communication Options | RS-232 / RS-485 / Ethernet (optional) |
| Alarm Outputs | 7 dry-contact relays (including sample flow monitor) |
| Calibration | Auto-calibration with audit-trail logging |
| Data Storage | Internal non-volatile memory (24-month trend retention) |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 10–50 kPa |
| Power | 100–120 VAC / 220–240 VAC, 50/60 Hz |
| Dimensions | 482 mm (W) × 511 mm (D) × 177 mm (H), 4U 19″ rack-mountable |
| Weight | 9 kg |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0211 |
| Repeatability | ±1% FS |
| Detection Limit | 0.03 ppm |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Oven Temperature Range | 5 °C to 45 °C |
| Carrier Gas Purity Requirement | 5N (99.999%) |
| Compliance | Designed for continuous online operation in industrial process environments |
| Configuration | Modular sensor architecture with field-replaceable sensing modules |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0221 |
| Repeatability | < ±0.1% O₂ |
| Detection Limit | < ±0.1% O₂ |
| Detector Type | Paramagnetic |
| Column Temperature Control Range | 5 °C to 45 °C |
| Gas Supply Purity | 5N (99.999%) |
| Output | 4–20 mA |
| Communication | RS-485, Ethernet, Modbus (optional) |
| Relay Outputs | 3 × user-configurable dry-contact relays |
| Data Export | CSV format |
| Calibration | Auto/manual zero/span, multi-point, calendar-based scheduling, programmable purge time, intelligent stability detection |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | N2 Sense |
| Detection Limit | 0.5 ppb |
| Repeatability | <1% |
| Detector Type | Enhanced Plasma Discharge (EPD) |
| Column Temperature Range | Ambient +4 °C to 450 °C |
| Carrier Gas Requirement | High-Purity Gas |
| Output | 4–20 mA, Ethernet, RS-232, MQTT |
| Data Storage | 12-month onboard logging |
| Dimensions | 133 × 202 × 330 mm (19″ rack-mountable) |
| Power | 24 VDC, 40 W |
| Operating Temperature | 5–40 °C |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 3–25 PSIG |
| Response Time | <10 s (90% step change at 75 mL/min) |
| Drift | <0.5% FS |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–100 ppm, up to 1% N₂ in Ar/He |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | KA8000Ex |
| Repeatability | ±2% |
| Detection Limit (MDL) | 0.5 ppb H₂S |
| Detector Type | EPD (Enhanced Plasma Discharge Detector) |
| Column Oven Temperature Range | −4 °C to 200 °C |
| Carrier Gas Requirement | 5N-grade He, Ar, or N₂ |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Industrial Instrument |
| Model | P5100 |
| Price Range | USD 70,000 – 140,000 |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PGC-3000 |
| Price Range | USD 70,000 – 140,000 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GC-2000 |
| Pricing | Upon Request |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | FOV 3000 |
| Pricing | Upon Request |
| Explosion-Proof Enclosure | FL3000 EX (316 Stainless Steel Powder-Coated) |
| Dimensions (W×D×H) | 800 × 800 × 1800 mm |
| Compressed Air Requirement | ≥0.1 MPa, 0.5 m³/h |
| Power Supply | 220 VAC, 5 kW |
| Operating Temperature Range | −10 to +45 °C |
| Explosion Protection Rating | Ex db mb px b IIC T6 Gb |
| Detectors Supported | FID, TCD, ECD, FPD, NPD, PDHID |
| Column Oven | Five-Zone Independent Temperature Control with Back-Door Rapid Cooling & Programmable Ramp |
| Carrier Gas Control | Third-Generation Fulit EPC (Electronic Pressure Control) |
| Communication Interfaces | Ethernet, 4G, Wi-Fi, RS232/RS485/RS422, 4–20 mA Analog Output |
| Software Platform | LoongOS-5.0 (Linux-based, proprietary real-time OS) |
| Data Storage | Embedded MariaDB — ≥1 year of quantitative results |
| Compliance Standards | HJ 38–2017, HJ 604–2017, HJ 1013–2018, HJ 212, FL97, Modbus/TCP, Modbus-RTU |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4085 |
| Pricing | Upon Request |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 210 AHC |
| Detection Limit | <30 ppb |
| Carrier Gas Flow Rate | ≈30 cc/min |
| Carrier Gas Pressure | 60 psig |
| Sample Inlet Pressure | 5 psig (max 20 psig) |
| Calibration Gas Pressure | 5 psig (max 20 psig) |
| Operating Temperature | 5–40 °C |
| Power Requirement | 400 W |
| Dimensions (W×H×D) | 42.9×31.1×58.4 cm |
| Net Weight | 23 kg |
| Mounting | 19″ EIA rack (7U) or benchtop |
| Gas Fitting | 1/8″ Swagelok |
| Analog Outputs | six 4–20 mA channels |
| Input Trigger | TTL or dry contact |
| Display | 16×2 character LED-backlit LCD (99.0×24.0 mm active area) |
| User Interface | membrane keypad (non-contact digital input) |
| Linear Range | 5–120 ppb (1×10³ dynamic range) |
| Sample Introduction | dual-solenoid automated valve system with fixed-volume sampling loop |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GOW-MAC 402 |
| Price Range | USD 1,500 – 7,500 |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 5900 DID |
| Detector Type | Discharge Ionization Detector (DID) |
| Detection Range | 1 ppb to <0.5% (v/v) |
| Carrier Gas | Helium |
| Construction | Stainless Steel or Corrosion-Resistant System |
| Compliance | Designed for Industrial Process Monitoring and Trace Impurity Analysis |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 592 |
| Detector Type | Discharge Ionization Detector (DID) |
| Detection Range | 1 ppb to <0.5% (v/v) |
| Carrier Gas | Ultra-High-Purity Helium |
| Installation Options | Benchtop or 19″ Rack-Mounted |
| Construction Options | Stainless Steel or Corrosion-Resistant Wet-Coated Surfaces |
| Compliance | Designed for ASTM D7613, ISO 8573-5, and semiconductor-grade gas purity monitoring |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA 8000Plus |
| Repeatability | <1% RSD |
| Detection Limit | 0.5 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | –4 °C to 450 °C |
| Carrier Gas Requirement | Ultra-High-Purity Gases |
| Regulatory Status | Import-Class Industrial Instrument |
| Brand | KA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KA8000Ex |
| Price Range | USD 68,000–136,000 (FOB) |
| Repeatability | <1% RSD |
| Detection Limit | <1 ppb (H₂S, COS, SO₂, CH₃SH) |
| Detector Type | Enhanced Plasma Detector (EPD) |
| Column Oven Temperature Range | −5°C to 300°C |
| Carrier Gas Requirements | Argon, Helium, or Nitrogen (inert only) |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA6000 |
| Repeatability | <1% |
| Detection Limit | 1 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | −5 °C to 300 °C |
| Carrier Gases | N₂, Ar, He |
| Compliance | Fully compatible with ASTM D7622, ISO 8573-5, USP <467>, and EPA Method TO-15/TO-17 workflows |
| Software | Embedded GC control platform with 21 CFR Part 11–compliant audit trail and GLP/GMP data integrity architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGC 8200 |
| Pricing | Available Upon Request |
| Brand | Pannatek |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PGC-80 / Low-Carbon VOCs Analysis |
| Price Range | USD 14,000 – 70,000 |
| Detection Range | 0–300 ppb (cryo-trap mode) |
| Detection Limit | ≤0.05 ppb (propane, FID) |
| Repeatability | RSD ≤3% (at 10 ppb propane) |
| Cycle Time | 15–30 min |
| Cryogenic Trap Temperature | −20 °C |
| Flash Heating Rate | up to 40 °C/s |
| Detector | Flame Ionization Detector (FID) |
| Carrier Gas | Ultra-High-Purity Nitrogen or Zero-Air (≥99.999%) |
| Fuel Gas | Ultra-High-Purity Hydrogen (≥99.999%) |
| Make-up/Support Air | Zero-Air (hydrocarbons <20 ppb) |
| Power | <800 W, 220 V AC / 50 Hz |
| Output Interfaces | 4–20 mA, RS232/RS485, Ethernet |
| Enclosure | 19″ rack-mount, 6U height |
| Flow Control | Electronic Pressure Control (EPC), resolution 0.01 psi |
| Sample Introduction | Diaphragm pump + precision Mass Flow Controller (MFC) |
| Column Configuration | Pre-column with backflush capability |
| Surface Treatment | Deactivated and passivated flow path |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGC2009 |
| Pricing | Available Upon Request |
| Brand | SYSTEA |
|---|---|
| Model | ProGC-3500/3600 |
| Application Domain | Natural Gas, Metallurgy, Petrochemical, Coal Chemical, Power Generation, Pharmaceutical |
| Detector Options | TCD, FID, FPD, PDD |
| Explosion Protection Rating | IIC T5 |
| Origin | Zhejiang, China |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ProGC-3800 |
| Pricing | Available Upon Request |
| Explosion Protection Rating | Ex d IIC T6 Gb |
| Ingress Protection Rating | IP65 |
| Column Oven Thermal Stability | ±0.01 °C |
| Detector Compatibility | TCD, FID, FPD, PDD |
| Primary Application Domain | Natural Gas Process Monitoring |
| Brand | FPI (Focus Photonics) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ProGC-3900 |
| Pricing | Upon Request |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | EXPEC 2000 VOC Continuous Emission Monitoring System (CEMS) |
| Pricing | Upon Request |
| Repeatability | Not Specified |
| Detection Limit | Not Specified |
| Detector Type | Flame Ionization Detector (FID) |
| Column Oven Temperature Range | Ambient to 220 °C |
| Carrier Gas Requirement | High-Purity Nitrogen (≥99.999%) |
| Hydrogen & Zero Air Supply | Integrated Onboard Generators |