Optical Instruments
Filter
Showing 691–720 of 1896 results
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | Hysitron PI 89 |
| Application | In-situ nanomechanical testing inside SEM and FIB/SEM chambers |
| Sensing Principle | Capacitive displacement sensing with sub-nanometer resolution |
| Actuation | Electromechanical force actuation |
| Force Range | Up to 100 mN (standard configuration) |
| Displacement Resolution | < 0.2 nm |
| Positioning Accuracy | ≤ 50 nm (with integrated linear encoder and motorized tilt/rotate stages) |
| Compatibility | Fully compatible with FEI/Thermo Fisher, Zeiss, JEOL, and Hitachi SEM/FIB platforms |
| Analytical Integration | Synchronized acquisition with EBSD, EDS, BSE, and TKD detectors |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | LUMOS II |
| Detector Options | TE-MCT (liquid-nitrogen-free), DTGS, LN2-cooled MCT |
| FPA Imaging Capability | Yes |
| Spatial Resolution | 0.6 µm/pixel |
| Field of View | 1490 × 1118 µm² |
| PermaSure+ Real-Time Calibration System | Yes |
| Sealed Optics (No Purge Required) | Yes |
| ZnSe Optical Components | Standard |
| Motorized Automation | Fully motorized aperture, detector, and technique switching |
| Sample Stage | Free-access, manual/optional motorized, max. 40 mm sample size |
| Compliance | FDA 21 CFR Part 11, cGMP, USP <1119>, EP 2.2.24, ALCOA+ data integrity principles |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | NanoTracker 2 |
| Laser Class | Class 1 |
| Positional Resolution | Sub-nanometer (closed-loop) |
| Force Sensitivity | < 0.1 pN/√Hz |
| Trap Stiffness Range | 0.01–100 pN/µm |
| Detection Bandwidth | Up to 100 kHz |
| Sample Stage Options | Piezo-driven XYZ stage (optional) |
| Illumination | LED-based Köhler illumination with condenser lens |
| Control Interfaces | TTL-triggered external devices (cameras, spectrometers, PMTs, APDs) |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, GLP/GMP-compatible experiment logging |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | PI 89 AUTO |
| Application Domain | In situ SEM-integrated nanomechanical characterization |
| Automation Level | Fully motorized stage + patented dual-axis rotation/tilt (R/T) mechanism |
| Software Platform | TriboScan Auto v5.0+ |
| Compliance Framework | Designed for GLP-compliant workflows |
| Sample Environment | Compatible with standard high-vacuum and low-vacuum SEM chambers (FEI, Thermo Fisher, Zeiss, JEOL) |
| Maximum Load Resolution | Sub-100 nN |
| Displacement Resolution | < 0.05 nm |
| Stage Precision | ±50 nm positional repeatability over 10 mm × 10 mm travel range |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX EBSD |
| Pricing | Upon Request |
| CCD Camera Resolution | 640 × 480 pixels |
| Maximum Stage Speed | 10 mm/s |
| Spatial Resolution | 1.5 nm |
| Angular Resolution | 0.1° |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | QUANTAX Transmission Electron Microscopy (TEM/STEM) EDS |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1500 kcps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 10–300 mm² |
| Window Options | Polymer Ultrathin Window or Windowless |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | QUANTAX FlatQUAD |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 4,000 kcps |
| Elemental Detection Range | Boron (B) to Californium (Cf) |
| Detector Active Area | 10–300 mm² |
| Window Type | Windowless |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Quantax XFlash Series |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1,500 kcps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 10–300 mm² |
| Window Options | Ultrathin Polymer Window or Windowless Configuration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX xsense |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX XTrace |
| Pricing | Available Upon Request |
| Brand | Caikon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | CK400CM |
| Power Input | AC 220 V ±10%, 45–60 Hz |
| Heating Supply | DC 24 V / 3 A |
| Max. Power Consumption | 260 W |
| Temperature Range | Ambient to 400 °C (tested at 25 °C ambient, natural convection cooling) |
| Stage Surface Temp. Limit | ≤70 °C at housing (when hot zone = 400 °C) |
| Max. Sample Load | 200 g |
| Heating Zone Diameter | φ41 mm |
| Stage Disc Diameter | φ99 mm × 11 mm thick |
| Optical Aperture | φ3.8 mm |
| Display | Industrial capacitive full-color touchscreen, 800 × 480 resolution |
| Control Core | 32-bit ARM processor with proprietary fuzzy PID adaptive algorithm |
| Heating Element | Ceramic PTC heater with uniform thermal distribution |
| Temp. Accuracy | ≤±0.5% of full scale |
| Temp. Stability (Drift) | ±0.5 °C |
| Response Time (Setpoint Hold) | ≤0.01 s |
| Ramp Rates | 5, 10, 20, 40, or 80 °C/min (user-selectable) |
| Ramp Time | ≤100 s (RT → 100 °C), ≤190 s (RT → 200 °C), ~17 min (RT → 400 °C, dependent on ambient & ramp rate) |
| Dimensions (Control Unit) | 280 × 220 × 150 mm |
| Brand | Caikon Optical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Upright Metallurgical Microscope |
| Equipped with Image Analysis Software | Yes |
| Total Optical Magnification | 50×–500× (up to 2000× with system magnification) |
| Eyepiece | Wide-Field 10× (Φ22 mm) |
| Objective Lenses | PL 5×/0.12, PL 10×/0.25, PL 40×/0.60 (spring-loaded), PL 60×/0.70 (spring-loaded) |
| Focusing Mechanism | Coaxial coarse/fine focus, fine adjustment graduation: 2 µm |
| Illumination | 6 V / 30 W halogen lamp (adjustable brightness, Köhler illumination for both epi- and trans-illumination) |
| Stage | Dual-layer mechanical stage (210 × 140 mm, travel range 75 × 50 mm) |
| Polarization System | Insertable polarizer/analyzer, 360° rotatable analyzer, removable from optical path |
| Camera | CK-500 Color CMOS Camera (2560 × 1920 resolution, 12-bit A/D, USB 2.0 interface, 22 fps at full resolution) |
| Software | Full-featured metallurgical image analysis suite supporting measurement (≥1 µm accuracy), annotation, report generation (PDF/CSV/XLS), GLP-compliant audit trail logging, and ISO 13079-compliant grain size evaluation |
| Brand | Chemn |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KL100 |
| Light Source Type | Monochromatic High-Power LED |
| Illumination Mode | External Irradiation |
| Spectral Range | 255–1650 nm (customizable in 5 nm increments, excluding select wavelengths) |
| Wavelength Options (Standard) | 365, 390, 400, 420, 455, 460, 520, 630, 730 nm |
| Frequency Modulation Range | 0–100 kHz |
| Input Voltage | 220 V AC |
| Electrical Power Consumption | 40 W |
| Spectral Bandwidth (FWHM) | 16 nm @ 418 nm |
| Maximum Optical Output Power | 9920 mW |
| Irradiance | 675 mW/cm² @ 418 nm (measured at 1 cm distance) |
| Wall-Plug Efficiency | 24.8% @ 418 nm |
| Operating Temperature | 0–45 °C |
| Dimensions | Ø63 × 135 mm |
| Intensity Control | 9-step discrete adjustment |
| Display | Integrated LED screen |
| Optical Design | Custom reflector cavity and collimating optics optimized per spectral band |
| Brand | CHIPNOVA |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CNS-VH-LR |
| Price | USD 1.00 (Reference Only – Contact for Quotation) |
| Brand | CHIPNOVA |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | Domestic (China) |
| Model | CNT-GNIH |
| Pricing | Upon Request |
| Instrument Category | In Situ Tensile/Compression Holder |
| Application Domain | Materials Science |
| Brand | CHIPNOVA |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CNT-SHE |
| Application Category | In Situ Liquid TEM |
| Primary Application Field | Catalysis |
| Instrument Class | In Situ TEM Sample Holder |
| Brand | CHNSpec |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CT-23 / CT-25 |
| Product Type | Automatic Portable Meter |
| Transmittance Range | 0–100% |
| Transmittance Repeatability | ±2% |
| Spectral Channels | UV (365 nm), Visible (380–760 nm, CIE photopic luminosity function), IR (940 nm & 1400 nm) |
| Sample Thickness Capacity | ≤13 mm |
| Measurement Time | <1 s |
| Display | 1.14″ full-color TFT (135 × 240 px) |
| Power | Rechargeable 750 mAh Li-ion battery (USB charging) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions | 115 × 70 × 14 mm |
| Compliance | CE-marked design principles |
| Brand | Chotest |
|---|---|
| Model | W402 |
| Light Source | White LED |
| Imaging Sensor | 1024 × 1024 pixels |
| Standard Objective | 10× (optional: 2.5×, 5×, 20×, 50×, 100×) |
| Zoom Lens | 0.5× standard (optional: 0.375×, 0.75×, 1×) |
| FOV (10×) | 0.98 × 0.98 mm |
| XY Stage | 140 × 100 mm travel, 320 × 200 mm footprint, 10 kg load capacity |
| Z Focus Range | 100 mm motorized |
| Vertical Resolution | ≤ 0.1 nm (environmental noise evaluation mode) |
| Surface Reflectivity Range | 0.05% – 100% |
| Dimensions (H×W×D) | 900 × 700 × 600 mm |
| Vibration Isolation | Active air-bearing optical table base |
| Brand | Chotest |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | W412 |
| Price | USD 135,000 (FOB Guangdong) |
| Brand | Chotest |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VT6000 |
| Price | USD 132,000 (FOB Shenzhen) |
| Measurement Principle | Optical Confocal Imaging |
| Z-Scan Range | 10 mm |
| XY Travel | 100 mm × 100 mm |
| Z-Axis Resolution | ≤ 0.5 nm (typical, dependent on objective and signal-to-noise ratio) |
| Height Measurement Accuracy | ±0.8% of full scale |
| Objective Lenses | 10×, 20×, 50×, 100× (motorized 5-position turret) |
| Field of View | 1.2 mm × 1.2 mm (10×) to 120 µm × 120 µm (100×) |
| Light Source | Broadband White LED |
| Platform Load Capacity | 10 kg |
| Instrument Dimensions | 520 × 380 × 600 mm |
| Weight | 50 kg |
| Software | Integrated 3D metrology suite with automated batch analysis, GLP-compliant audit trail, and ISO 25178–compliant parameter calculation |
| Brand | Chroma |
|---|---|
| Origin | Taiwan |
| Model | CS-150 / CS-160 |
| Luminance Range | 0.0001–999,900 cd/m² (CS-150), 0.0001–9,999,000 cd/m² (CS-160) |
| V(λ) Photopic Luminous Efficiency Match | Improved vs. CS-100A |
| Measurement Method | Non-contact, Single-point Spectral Radiance Integration |
| Optical System | SLR-type with Eyepiece Viewfinder and External LCD Display |
| Minimum Measurable Spot Diameter | 0.4 mm (with optional macro lens, CS-160 only) |
| Power Supply | Rechargeable Battery |
| Brand | auniontech (Distributor) |
|---|---|
| Origin | Germany |
| Manufacturer | Cinogy GmbH |
| Model | CinCam Pico CMOS-1201-Pico |
| Sensor Type | CMOS |
| Active Area | 5.7 mm × 4.3 mm |
| Pixel Count | 2560 × 1920 |
| Pixel Size | 2.2 µm × 2.2 µm |
| Spectral Range (Standard) | 400–1150 nm |
| Optional Ranges | 150–1150 nm (UV), 240–1150 nm (OM), 320–1150 nm (RT), 400–1320 nm + 1470–1605 nm (IR) |
| Dynamic Range | 70 dB |
| Mechanical Dimensions | 15 mm × 15 mm × 11.5 mm |
| Interface | USB 2.0 |
| Mount | C-mount / F-mount compatible |
| Software | RayCi-Lite / Standard / Pro |
| Data Export Formats | TIFF, PNG, PDF, Excel, AVI, MP4 |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Brand | CIQTEK |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | SEM3300 |
| Instrument Type | Floor-Standing Conventional SEM |
| Electron Source | Tungsten Filament |
| SEM Class | Entry-Level Tungsten-Filament SEM |
| Secondary Electron Resolution | 2.5 nm @ 20 kV |
| Magnification Range | 1× to 300,000× |
| Accelerating Voltage | 0.1 kV to 30 kV |
| Stage Travel | X: 120 mm |
| Y | 115 mm |
| Z | 50 mm |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PO2100 (01) |
| Imaging Resolution | 5472 × 3678 pixels |
| Camera Sensor | 20 MP Color CCD |
| Excitation/Emission Band | 400–500 nm |
| Application Domain | Geoscience, Environmental Biogeochemistry, Rhizosphere Research |
| Brand | CHIPNOVA |
|---|---|
| Model | CNT-OTAR-S |
| Holder Type | In Situ Tomographic Sample Holder |
| Compatible TEM Platforms | Thermo Fisher/FEI, JEOL, Hitachi (HR)TEM/STEM |
| Sample Mounting Options | Single-Axis Tip & C-Type Tip |
| Tip Exchangeable | Yes |
| Tip Configurations | 3 mm Half-Grid (C-Type), Rod/Conical (Single-Axis) |
| Maximum Tilt Range | ±54° (Tomographic Series) |
| Tilt Increment | 6° |
| Drift Rate | <0.5 nm/min (Stabilized State) |
| Holder Body Material | High-Strength Titanium Alloy |
| EDS/EELS/SAED Compatibility | Fully Supported |
| Application Domain | Materials Science, Nanogeology, In Situ Structural Analysis |
| Compliance | Designed for GLP-aligned electron tomography workflows |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable |
| Measurement Range | 0.05–100 NTU |
| Operating Temperature | 0–50 °C |
| Wavelength Range | 340–800 nm |
| Measurement Principle | Nephelometric (90° scattered light detection) |
| Accuracy | ≤5% FS |
| Repeatability | <0.5% |
| Stability | <0.5% |
| Light Source | Imported Cold LED (Lifespan ≥100,000 h) |
| Display | 3.5-inch Color TFT Touchscreen |
| Data Storage | >80,000 Records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth, Hotspot |
| Power | 5 V DC / 5600 mAh Li-ion Battery (12 h continuous operation) |
| Dimensions | 180 × 80 × 70 mm |
| Weight | 700 g |
| Compliance | GB/T 13200–1991, ISO 7027:2016 (Nephelometric Method) |
| Brand | CorActive |
|---|---|
| Origin | Canada |
| Model | SCF-UN-3/125-25 |
| Core Diameter | 3 µm |
| Cladding Diameter | 125 µm |
| Coating Diameter | 250 µm |
| Numerical Aperture (NA) | ~0.12 |
| Operating Wavelength Range | 1060–1600 nm |
| Fiber Type | Nonlinear, Passive, Step-Index, Single-Mode |
| Compatibility | Pump & Signal Delivery in High-Power Fiber Lasers and Amplifiers |
| Brand | CORETECH (Wuxi Dixin Technology) |
|---|---|
| Drive Type | Brushless Direct-Drive Rotary Motor |
| Guidance | Precision Crossed-Roller Bearings |
| Maximum No-Load Bandwidth | >100 Hz |
| Maximum No-Load Angular Velocity | >150°/s |
| Positional Stability & Minimum Incremental Motion | <0.5 arcsec (in vibration-isolated lab environment, with linear amplifier and AS feedback option) |
| Rotation Radius Options | 50 mm / 90 mm |
| Configurability | Single-axis standalone or dual-axis stacked assembly |
| Structural Architecture | Compact monolithic aluminum alloy housing with integrated thermal management |
| Compliance | Designed for integration into ISO 14644-1 Class 5–7 cleanroom-compatible motion systems |
| Mounting Interface | Standard M4/M6 tapped holes per ISO 20957-2 |
| Feedback Option | Compatible with Analog Sin/Cos (AS) position sensors |
| Brand | -- |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | CS-810 |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Benchtop |
| Product Category | Spectrophotometric Colorimeter |
| Illuminant | CLEDs (Full-Spectrum Balanced LED Source) |
| Geometry | D/0 (Diffuse Illumination / 0° Viewing) |
| Transmission Measurement Range | 0–200% (UV-Enhanced Silicon Photodiode) |
| Color Scales Supported | Platinum-Cobalt (Hazen/APHA), Gardner, CIE L*a*b*, L*C*h*, ΔE*ab, ΔE*00, XYZ, Yxy, RGB, sRGB, Hunter Lab |
| Sample Compatibility | Transparent & Near-Transparent Liquids, Glass Substrates |
| Compliance | ASTM D1209, ASTM D5386, ASTM E308, ISO 7724-1, ISO 11664-4, USP <631>, JIS Z 8722 |
| Brand | — |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | CS-821N |
| Price Range | USD 4,200 – 7,000 |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | Desktop |
| Optical Geometry | d/8° Integrating Sphere |
| Illumination Sources | Pulsed Xenon Lamp & LED |
| Repeatability | ΔE*ab ≤ 0.015 |
