Optical Instruments
Filter
Showing 991–1020 of 1896 results
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | WZB-175 |
| Price Range | USD 700–1,400 |
| Product Type | Portable |
| Measurement Range | 0–2000 NTU (auto-ranging across four sub-ranges) |
| Resolution | 0.01 / 0.1 / 1 NTU (auto-selected by range) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Accuracy | ±6% of reading |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Calibration Points | Up to 6 points (2, 20, 200, 500, 1000, 2000 NTU) |
| Data Storage Capacity | 2000 measurements |
| Display | 4.3-inch color TFT LCD touchscreen |
| Protection Rating | IP65 |
| Interface | Micro-USB (PC communication), RS-232 (printer output) |
| Power Supply | Rechargeable Li-ion battery (with AC adapter: Input AC 100–240 V, Output DC 5 V / 2 A) |
| Dimensions & Weight | 90 × 250 × 90 mm, approx. 0.8 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | WZB-176E |
| Product Type | Portable |
| Measurement Range | (0.00–9.99) NTU, (10.00–99.9) NTU, (100.0–999) NTU, (1000–2000) NTU |
| Resolution | 0.01 NTU / 0.1 NTU / 1 NTU |
| Operating Temperature | 5–35 °C |
| Accuracy | ±6% |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS/30 min |
| Stability | ±0.5% FS/30 min |
| Calibration Points | Up to 6 points (2, 20, 200, 500, 1000, 2000 NTU) |
| Data Storage Capacity | 2000 records |
| Display | 4.3-inch color TFT touchscreen |
| Protection Rating | IP65 |
| Power Supply | Rechargeable Li-ion battery |
| Dimensions & Weight | 90 × 250 × 90 mm, approx. 0.8 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | WZS-180A |
| Price Range | USD 1–720 (FOB) |
| Form Factor | Benchtop / Laboratory |
| Measurement Ranges | (0.00–20.00) NTU, (20.0–200.0) NTU, (200–1000) NTU |
| Resolution | 0.01 NTU (low range), 0.1 NTU (mid range), 1 NTU (high range) |
| Accuracy | ±8% FS |
| Repeatability | ≤1.0% |
| Zero Drift | ±1.0% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Light Source | 860 nm Infrared LED, compliant with ISO 7027 and HJ 1075 |
| Calibration Options | Zero-point correction + up to 3-point calibration (2, 20, 200 NTU) |
| Display | Monochrome LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| IP Rating | IP65 |
| Dimensions (L×W×H) | 330 × 250 × 130 mm |
| Weight | ~2.5 kg |
| Standard Accessories | Certified 400 NTU turbidity standard solution, calibrated turbidity vials |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0.00–500 NTU |
| Resolution | 0.01 NTU (at low range), 0.1 NTU (mid range), 1 NTU (high range) |
| Operating Temperature | 5–35 °C |
| Accuracy | ±6% FS |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Calibration Points | Up to 5 points (2, 20, 50, 200, 500 NTU) |
| Data Storage Capacity | 1000 records |
| Display | 5.7-inch color LCD |
| Protection Rating | IP54 |
| Power Supply | DC24V adapter (AC100–240V input) |
| Dimensions & Weight | 189 × 282 × 84 mm, ~1.5 kg |
| Compliance | ISO 7027, HJ 1075-2019 |
| Measurement Principles | Nephelometric (90° scatter) and Ratio (scatter + transmission) methods |
| Units Supported | NTU, FNU, EBC |
| Connectivity | RS-232 serial port, USB interface |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WZS-182E |
| Price | USD 980 (FOB Shanghai) |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0.00–9.99 NTU |
| Resolution | 0.01 / 0.1 / 1 NTU (auto-ranging) |
| Operating Temperature | 5–35 °C |
| Accuracy | ±6% of reading |
| Light Source | Tungsten-halogen lamp |
| Measurement Principle | Nephelometric (90° scatter) and Ratio nephelometric-scatter/transmission |
| Compliance | USEPA Method 180.1, HJ 1075–2019, JJG 880–2006 |
| Display | 5.7-inch color LCD with tactile keypad |
| Protection Rating | IP54 |
| Calibration Standards Included | Long-life turbidity standards at 20, 200, and 500 NTU |
| Data Storage | 1000 measurement records |
| Interface | RS-232 (for thermal printer), USB-B (for PC communication) |
| Software Support | Dedicated Leici turbidity data management software (Windows-compatible) |
| GLP Features | Audit-trail enabled timestamped records, user ID logging, calibration history, factory reset with zero & calibration value recovery |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | WZS-188E |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | (0.000–9.999) NTU, (10.00–99.99) NTU, (100.0–999.9) NTU, (1000–4000) NTU |
| Resolution | 0.001 / 0.01 / 0.1 / 1 NTU |
| Accuracy | ±6% |
| Light Source | Tungsten-Halogen Lamp |
| Compliance | US EPA Method 180.1, HJ 1075–2019 |
| Measurement Principle | Nephelometric (90° scatter) and Scatter-Transmission dual-mode |
| IP Rating | IP54 |
| Display | 7-inch HD color capacitive touchscreen |
| Calibration Options | Single-point or multi-point |
| Units | NTU, FNU, EBC |
| Modes | Standard measurement, averaging mode (for dynamic suspension stabilization), auto-ranging |
| Data Management | Onboard storage, recall, deletion, USB export, RS-232 printer output |
| Software Interface | PC communication via dedicated software (USB) |
| GLP Support | Full audit trail, timestamped records, user ID logging, calibration history retention |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | WZS-190S |
| Price Range | USD 1,400–2,100 |
| Instrument Type | Benchtop / Laboratory |
| Measurement Range | 0–4000 NTU (tungsten lamp), 0–2000 NTU (860 nm LED) |
| Resolution | 0.001 NTU (lowest range) |
| Accuracy | ±6% FS |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS / 30 min |
| Stability | ±0.5% FS / 30 min |
| Light Sources | Dual-source — Tungsten lamp (400–600 nm, compliant with US EPA Method 180.1 & HJ 1075-2019), 860 nm LED (compliant with ISO 7027 & HJ 1075-2019) |
| Calibration Points | Up to 8-point (tungsten), up to 7-point (LED) |
| Data Storage Capacity | 2000 turbidity measurements per light source + 2000 verification records + 500 system logs + 4000 operation logs |
| Environmental Operating Conditions | 5–35 °C, ≤85% RH |
| Power Supply | AC 100–240 V input, DC 20 V output |
| Dimensions & Weight | 300 × 200 × 88 mm, ~1.5 kg |
| Protection Rating | IP54 |
| Compliance Standards | JJG 880–2006, HJ 1075–2019, ISO 7027:2016, US EPA Method 180.1 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | WZT-701 |
| Price Range | USD 1,400 – 2,800 |
| Configuration | Online Continuous Monitoring |
| Measurement Range | 0.00–500.0 NTU |
| Resolution | 0.01 NTU (≤10 NTU), 0.1 NTU (>10 NTU) |
| Accuracy | ±10% FS |
| Repeatability | ≤2% |
| Zero Drift | ±0.5% FS / 30 min, ±1% FS / 24 h |
| Span Drift | ±5% FS / 24 h |
| MTBF | ≥720 hours |
| Enclosure Rating | IP65 |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Dimensions (W×H×D) | 160 × 160 × 110 mm |
| Weight | 5.0 kg |
| Output | Isolated 4–20 mA DC (user-configurable span/zero), RS-232 serial interface |
| Calibration | Single-point or two-point standard calibration |
| Alarm Functions | Programmable high/low limit alerts with latching logic |
| Data Retention | Non-volatile memory for settings and calibration history |
| Environmental Operating Range | 0–40 °C, <90% RH non-condensing |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | WYL-3 |
| Price Range | USD 1,400 – 7,000 |
| Stress Measurement Range | 0–560 nm |
| Full-Wave Retardation Plate | 560 nm |
| Max Sample Dimensions | Width ≤ 440 mm, Height ≤ 240 mm, Length ≤ 440 mm |
| Brand | LICHEN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | WSB Series |
| Price Range | USD 170 – 475 |
| Power Supply | WSB-1: 5×AA alkaline batteries (DC 1.5 V) or AC 220 V / 50 Hz |
| WSB-2 | AC 220 V / 50 Hz |
| Display | LCD |
| Whiteness Formula | Blue Light Whiteness WB = R₄₅₇ |
| Measurement Range | 0–199 |
| Aperture Diameter | WSB-1: Φ15 mm |
| WSB-2 | Φ30 mm |
| Zero Drift | ≤0.2 / 10 min |
| Indication Drift | ≤0.3 / 3 min |
| Repeatability Error | WSB-1: ≤0.2 |
| WSB-2 | ≤0.3 |
| Net Weight | WSB-1: 0.4 kg |
| WSB-2 | 2.1 kg |
| Dimensions | WSB-1: 70 × 220 × 75 mm |
| WSB-2 | 260 × 330 × 250 mm |
| Calibration Standard | Certified National White Reference Tile |
| Preheat Time | 30 seconds |
| Compliance | GB/T 2913, GB/T 5950, GB/T 8940.1, GB/T 12097, GB/T 13025.2 |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | LH-P305 |
| Product Type | Portable |
| Measurement Range | 0–2000 NTU |
| Resolution | 0.01 NTU (for values <10 NTU) |
| Operating Temperature | 5–40 °C |
| Accuracy | ±10% |
| Light Source | Dual-beam LED (White + Infrared) |
| Detection Principle | 90° Scattering + Transmission Ratio Method |
| Calibration | Multi-point calibration with automatic storage of latest calibration record |
| Display | 3.5-inch high-resolution color LCD with dial-style UI |
| Power | Rechargeable lithium battery (8 h typical operation), auto-off after 10 min idle, USB Type-C charging |
| Accessories Included | Formazin standard solution, sealed reaction tubes, light-shielding cap, adapter, silicone oil |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF228 |
| Light Source | CIE Illuminant C (Tungsten-Halogen) |
| Gardner Scale Range | 1–18 |
| Compliance | ASTM D1544, ISO 4630, AOCS Cd 13a-97 |
| Viewing Method | Triple-Field Visual Comparison |
| Optical Path | Fixed 10.0 mm cell path |
| Standard Filters | Certified Gardner glass filters (NIST-traceable) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF229 |
| Light Source | CIE Illuminant C (Tungsten-Halogen Lamp) |
| Color Scale | AOCS Cc 13a-43 FAC Scale (Odd-Numbered, 1–50) |
| Viewing System | Triple-Field Visual Comparison |
| Compliance | AOCS Official Method Cc 13a-43 |
| Intended Use | Visual color assessment of dark oils, fats, tallow, lard, and rendered animal lipids |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF325 |
| Light Path | 113 mm |
| Standard Scale Range | 0–250 mg Pt/L (APHA/Hazen) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Sample Compatibility | Clear, pale-yellow liquids |
| Calibration Method | Nessleriser 2150 comparator disc system |
| Scale Segments | NSH (10–90), NSB (70–250) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF327 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 288 mm |
| Standard Discs | 1209/1 (0–30 APHA), 1209/2 (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF328 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 250 mm |
| Standard Discs | CAA (0–30 APHA), CAB (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF329 |
| Measuring Range | 0–250 mg Pt/L (APHA/Pt-Co Scale) |
| Cell Pathlengths | 113 mm and 250 mm |
| Standard Discs | CAA (0–30), CAB (30–70), NSB (70–250) |
| Compliant Standards | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF607 |
| Light Source | CIE Illuminant B (Tungsten-Halogen Lamp) |
| EBC Scale Range | 2–27 |
| Resolution | 0.5 EBC units (2–10), 1.0 EBC unit (10–27) |
| Viewing Method | Triple-Field Visual Comparison |
| Compliance | EBC Method No. 4.1.1 (European Brewery Convention), ISO 4833-1:2013 (referenced for color standardization in fermented beverages) |
| Optical Path Options | Standard 10 mm, optional 20 mm and 50 mm cuvettes for extended range dilution |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF650 |
| Measurement Range | 0.5–8.0 ASTM Colour Scale |
| Light Source | 12 V / 20 W Halogen Tungsten Lamp (CIE Illuminant C) |
| Viewing Geometry | Triple-Field Visual Comparison |
| Cell Path Length | 33 mm |
| Standard Discs | Two Rotating Glass Filter Discs (Disc 1: 0.5, 1.5, ..., 7.5 |
| Disc 2 | 1.0, 2.0, ..., 8.0) |
| Compliance | ASTM D1500, ISO 2049, IP 196, DIN 51578, BS 5859, JIS K 2580, NF T60-104, NBN T52-109, FTM 719-102 |
| Certification | CE |
| Brand | Lovibond / Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | AF710-3 |
| Compliance | AOCS Cc 13b-45, ASTM E313, ASTM D848 |
| Sample Cell | Flat-bottom glass tube with calibrated oil column markings at ½", 1", and 5¼" |
| Optical Path | Fixed-path visual comparison system |
| Color Scale | AOCS-Tintometer® RY (Red-Yellow) scale, distinct from standard Lovibond® RYBN |
| Light Shielding | Integrated dual-tube holder with side-light exclusion design |
| Intended Use | Visual color assessment of transparent to semi-transparent liquids in edible oils, fats, petrochemicals, waxes, and distilled spirits |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Comparator 2000 Series |
| Compliance Standards | ASTM D1209, ASTM D1500, ASTM D6045, ISO 2049, IP 196, EBC, IFU, Ph. Eur. 2.2.2, USP, DIN 6162, IMSI |
| Light Source Compatibility | Daylight 2000 Illumination System (optional, recommended for critical measurements) |
| Measurement Principle | Visual color comparison against standardized glass color standards |
| Application Scope | Pharmaceuticals, Clinical Diagnostics, Food & Beverage, Petrochemicals, Water & Wastewater, Edible Oils & Fats |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Comparator 3000 Series |
| Measurement Principle | Tristimulus Visual Comparison Against Certified Glass Standards |
| Light Source | CIE-A Compliant Halogen Tungsten Lamp (2856 K) |
| Viewing Field | Triple-Field Simultaneous Comparison |
| Standard Compliance | ASTM D1544, ASTM D1500, ASTM D6045, AOCS Cc 13a-43, DIN EN ISO 4630-1, GB/T 4928-2001, ISO 2049, IP 196 |
| Optical Path Lengths | 10.65 mm (Gardner, FAC), 25 mm (EBC), 33 mm (ASTM) |
| Included Accessories | Model-Specific Certified Glass Color Discs, Calibration Certificate Traceable to NPL/UKAS |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | UK |
| Model | EC2000 & EC3000 |
| EC2000 Pt-Co Range | 0–500 Pt-Co, Resolution: 1 Pt-Co, Repeatability: ±3% or ±1 Pt-Co, Path Length: 50 mm, Standard: ASTM D1209 |
| EC2000 Gardner Range | 0–18 Gardner, Resolution: 0.1 Gardner, Repeatability: ±0.2 Gardner, Path Length: 10 mm, Standard: ASTM D1544, D6166 |
| EC3000 ASTM Range | 0–8 ASTM, Resolution: 0.1 ASTM, Repeatability: ±0.1 ASTM, Path Length: 33 mm, Standard: ASTM D1500, D6045 |
| EC3000 Saybolt Range | −16 to +30 Saybolt, Resolution: 1 Saybolt, Repeatability: ±1 Saybolt, Path Length: 50 mm, Standard: ASTM D156, D6045 |
| Viewing Field | 2-field (EC2000), 3-field (EC3000) |
| Cuvettes | Plastic and glass W100 cells in multiple path lengths (10 mm, 33 mm, 50 mm) |
| Calibration Standards | Bottled reference liquids (60 mL) and certified interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 & EC3000 |
| Light Source | White LED (25-year lifetime) |
| Detector | Trichromatic sensor |
| Display | 3.5-inch TFT color LCD, 320×240 resolution, 24-bit color depth |
| Operation Modes | Resistive touchscreen + physical keypad |
| Sample Holder | W100-series cuvette slots (for EC and W100 cuvettes) |
| Housing | Flame-retardant ABS, 106 × 210 × 57 mm (W × D × H) |
| Interface | USB 2.0 (Mini-B) |
| Power Supply | 4 × AA batteries or USB bus power |
| Storage Capacity | ≥20,000 test results |
| Max. Sample Temperature | 80 °C |
| EC2000 Pt-Co Range | 0–500 Pt-Co, Resolution: 1 Pt-Co, Repeatability: ±3% or ±1 Pt-Co (whichever greater), Pathlength: 50 mm, Standard: ASTM D1209 |
| EC2000 Gardner Range | 0–18 Gardner, Resolution: 0.1 Gardner, Repeatability: ±0.2 Gardner, Pathlength: 10 mm, Standards: ASTM D1544, D6166 |
| EC3000 ASTM D1500 Range | 0–8, Resolution: 0.1, Repeatability: ±0.1, Pathlength: 33 mm, Standards: ASTM D1500, D6045 |
| EC3000 Saybolt Range | −16 to +30 Saybolt, Resolution: 1 Saybolt, Repeatability: ±1 Saybolt, Pathlength: 50 mm, Standards: ASTM D156, D6045 |
| Viewing Field | Dual-field (EC2000) / Triple-field (EC3000) |
| Cuvettes | W100 plastic and glass cuvettes (50 mm, 33 mm, 10 mm pathlengths) |
| Calibration Standards | Pre-filled 60 mL reference solutions and certified EC-series interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Gardner |
| Measurement Range | 0–18 Gardner |
| Resolution | 0.1 Gardner |
| Repeatability | ±0.2 Gardner |
| Path Length | 10 mm |
| Compliance | ASTM D1544, ASTM D6166 |
| Viewing Field | Dual-field |
| Cuvettes | 3 × 10 mm plastic (W100), 1 × 10 mm glass (W100) |
| Calibration Standards | 60 mL reference liquid vial, certified filter set |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Pt-Co |
| Measurement Range | 0–500 Pt-Co |
| Resolution | 1 Pt-Co |
| Repeatability | ±3% or ±1 Pt-Co (whichever is greater) |
| Path Length | 50 mm |
| Standard Compliance | ASTM D1209, ISO 6271, APHA Method 2120 B, USP <631> |
| Viewing Field | Dual-field (2-field) comparator display |
| Cuvettes | 3 × plastic 50 mm cuvettes (W100), 1 × glass 50 mm cuvette (W100) |
| Calibration Standards | 60 mL certified Pt-Co reference solution |
| Filter Set | Integrated certified interference filters (traceable to NPL/UKAS) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 ASTM |
| Measurement Range | 0–8 ASTM units |
| Resolution | 0.1 unit |
| Repeatability | ±0.1 unit |
| Path Length | 33 mm |
| Standard Compliance | ASTM D1500, ASTM D6045 |
| Field of View | 3-field |
| Cuvette Types | Two 33 mm plastic cuvettes (W100), Two 33 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL reference liquid standards |
| Filter Set | Two certified interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 Saybolt |
| Measurement Range | –16 to +30 Saybolt |
| Resolution | 1 Saybolt Unit |
| Repeatability | ±1 Saybolt Unit |
| Path Length | 50 mm |
| Standard Compliance | ASTM D156, ASTM D6045 |
| Field of View | Triple-field viewing system |
| Cuvettes | Two 50 mm plastic cuvettes (W100), two 50 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL certified reference liquids |
| Filter Set | Two calibrated interference filters |
| Brand | Lovibond / Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | ICx |
| Measurement Principle | Benchtop Transmittance Spectrophotometry |
| Standards Compliance | ASTM D1209, ASTM D5386, ISO 6271, ASTM E313 |
| Color Scales | Pt-Co/Hazen/APHA, CIEL*a*b*, Yellowness Index (YI) |
| Repeatability (Instrument) | ±0.5 Pt-Co (0–20), ±2 Pt-Co (>20) |
| Measurement Time | <10 s |
| Light Source | 12 V / 20 W Halogen Lamp (User-Replacable) |
| Sample Chamber | Sealed, Laser-Etched, Chemically Resistant |
| Optical Path Length Range | 0.1–152.4 mm |
| Display | 4.3" Full-Color LCD |
| Data Storage Capacity | >100,000 Measurements |
| Interface | USB, RS232 |
| Power Input | 110–250 V AC, 60 W, External 24 V Adapter |
| Dimensions (W×H×D) | 301 × 152 × 331 mm |
| Net Weight | 5.2 kg |
| Housing Material | Anodized Aluminum with Chemical-Resistant Textured Coating |
| Optical Components | Precision Glass Optics |
| Baseline Calibration | One-Touch Automatic |
| Illuminants & Observer | CIE Standard Illuminants A, C, D65 |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Certifications | CE, RoHS, WEEE |
| Warranty | 2 Years (Excluding Light Source and Consumables) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ICx |
| Instrument Type | Benchtop Spectrophotometric Colorimeter |
| Light Source | Tungsten-Halogen Lamp |
| Compliant Standards | ASTM D1209, ASTM D5386, ISO 6271, ASTM E313 |
| Built-in Color Scales | Pt-Co/APHA/Hazen, CIEL*a*b*, Yellowness Index (YI E313) |