Optical Measurement Instruments
Filter
Showing 511–540 of 788 results
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions (W×D×H) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA, Gardner, Iodine, Saybolt, ASTM Color, FAC, EBC, ASBC, ICUMSA, Pfund, ADMI, EP, USP, CIE L*C*h, Hunter Lab, spectral reflectance/data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/1 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA (ASTM D1209), Gardner (ASTM D1544/D6166), Iodine (DIN 6162), CIE XYZ/Lab, Spectral Reflectance Data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Pathlength Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Internal Memory | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing | Powder-coated steel enclosure |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Saybolt (ASTM D6045/D156), ASTM D1500, Pt-Co/Hazen/APHA (ASTM D1209), CIE XYZ/Lab values, spectral reflectance data |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability (CIE x,y) | ±0.0004 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 pixel backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Housing Material | Steel enclosure with textured epoxy coating |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 / PFXi950 / PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Colorimetric Repeatability | Δx,y ≤ ±0.0002 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–153 mm (0.004–6 in) |
| Filter Set | 16 Interference Filters |
| Data Storage Capacity | 100,000 Measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 Backlit LCD |
| Keypad | 23 Membrane Keys with Audible Feedback |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Power Supply | 90–240 V AC (External Adapter) |
| Dimensions | 515 × 196 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| GLP Features | Timestamped Audit Trail, User ID, Sample ID, Calibration Log |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950/P |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Path Length Range | 0.1–153 mm (0.004–6 in) |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Built-in Color Scales | ASTM D1500 (Petroleum), Saybolt, CIE L*a*b*, L*C*h*, Yellowness Index (ASTM E313), Whiteness Index (CIE/ISO 11475), and Spectral Data Output |
| Calibration | One-Touch Automatic Baseline Calibration |
| Data Storage Capacity | 100,000 measurements |
| Interface Options | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback, polyester overlay |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Housing | Steel chassis with textured epoxy coating |
| Dimensions (W×H×D) | 515 × 195 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heated Cell Holder | Up to 95 °C temperature control |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Optional Heater | Up to 95 °C |
| Operating Voltage | 90–240 VAC (external power supply) |
| Enclosure | Steel housing with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Lovibond RYBN, AOCS, Gardner, Pt-Co/Hazen/APHA, FAC, Chlorophyll A/B, β-Carotene, Iodine, Hess-Weis, Klett (Blue filter KS-42), Kreis, CIE XYZ/L*a*b*, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TG268 |
| Type | Automatic Gloss Meter |
| Measurement Angles | 20°, 60°, 85° |
| Measurement Areas (mm) | 20°: 10×10, 60°: 9×15, 85°: 5×36 |
| Measurement Ranges | 20°: 0–2000 GU, 60°: 0–1000 GU, 85°: 0–160 GU |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU), ±0.5% GU (100–2000 GU) |
| Geometry | CIE 1931 Standard Observer (2°), Illuminant C |
| Compliance | ISO 2813, ASTM D523, ASTM D2457, GB/T 9754 |
| Response Time | 1.0 s |
| Display | 3.5″ TFT capacitive touchscreen |
| Data Storage | 1,000 readings (Basic), 5,000 (Statistical & Continuous modes) |
| Interface | USB, RS-232 |
| Power | Rechargeable 3200 mAh Li-ion battery (up to 10,000 measurements per charge) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions | 160 × 75 × 90 mm |
| Weight | 350 g |
| Software | OnShade QC Suite (GLP-compliant reporting, audit trail, export to CSV/PDF) |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | TG60 |
| Measurement Angle | 60° |
| Compliant Standards | ISO 2813, ASTM D523, ASTM D2457, GB/T 9754 |
| Measuring Area | 9 mm × 15 mm |
| Gloss Range | 0–300 GU |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–300 GU) |
| Reproducibility | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU), ±0.5% GU (100–300 GU) |
| Illuminant | CIE Standard Illuminant C |
| Observer Angle | 2° |
| Measurement Time | 0.5 s |
| Dimensions | 160 mm × 75 mm × 90 mm |
| Weight | 350 g |
| Display | 3.5-inch TFT capacitive touchscreen |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Power | Rechargeable 3200 mAh Li-ion battery (up to 10,000 measurements per charge) |
| Interface | USB & RS-232 |
| Data Storage | 1,000 readings (basic mode) |
| Software | OnShade QC software with GLP-compliant reporting and export functionality |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TR 520 / TR 500 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Combined LED + UV |
| Spectral Range | 400–700 nm |
| Repeatability | TR520 (MAV/SCI): ΔE* ≤ 0.03 |
| TR500 (MAV/SCI) | ΔE* ≤ 0.05 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Material | Optical Glass (W600, W680) or Borosilicate Glass (W600-B) |
| Dimensions | 21 mm × 40 mm (W600 series) |
| Max. Operating Temperature | 40 °C (optical glass), 100 °C (borosilicate) |
| Compatible Instruments | Lovibond PFXi/PFX-195, 880, 950, 995, Model F, Comparator 2000+, Comparator 3000 |
| Pathlength Options | 2.5 mm to 6" (6.35 mm to 152.4 mm), including fractional inch and metric increments |
| Light Path Tolerance | ±0.05 mm per ISO 3664:2009 reference compliance |
| Brand | Lovibond® (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Product Type | Certified Liquid Color Reference Standards |
| Compliance | AOCS, ASTM D1209/D5386/D6166, ISO 6271, EBC 1.3, Gardner ASTM D1544, Pt-Co (APHA/Hazen) ASTM D1209, Saybolt ASTM D156 |
| Format | 5¼" (133 mm) cylindrical glass cells |
| Shelf Life | 12 months from date of manufacture |
| Traceability | NIST-traceable spectrophotometric validation |
| Packaging | Individually labeled, amber glass vials with tamper-evident seals |
| Uncertainty | ±0.1 color unit (RYBN), ±1 APHA unit (Pt-Co), ±0.2 Gardner unit |
| Brand | Lovibond® (Tintometer®) |
|---|---|
| Origin | United Kingdom |
| Product Type | Certified Reference Filter Sets for Visual and Instrumental Color Measurement |
| Compliance | AOCS, ASTM, EBC, EP, USP, Pfund, Gardner, Saybolt, Pt-Co/Hazen, FAC, CIE xyY, IP Units, Klett, β-Carotene, Chlorophyll A, FAC, EBC Brown/Yellow/Green/Red/Yellow Series |
| Configuration | Pre-assembled, instrument-specific filter kits with NIST-traceable calibration certificates |
| Certification | Individually certified with measured color values and stated uncertainty per ISO/IEC 17025-accredited methodology |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ATM |
| Price Range | USD 13,500 – 40,500 (est.) |
| Core Configuration | Pulsed Gas-Pumped Dye Laser System with Optional SHG Module |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | MNL100 |
| Laser Type | Pulsed Gas Laser (N₂) |
| Wavelength | 337.1 nm |
| Pulse Energy (guaranteed, ≥90% after 60M shots) | ≥140 µJ (MNL103-PD) / ≥120 µJ (MNL106-PD) |
| Pulse Width | ≤3 ns |
| Repetition Rate | 1–60 Hz |
| Beam Divergence | ≤3.5 × ≤3 mrad (standard) / ≤0.5 × ≤0.3 mrad (low-divergence variant) |
| Energy Stability | ≤2% RMS |
| Trigger Jitter (output sync) | <200 ps |
| Power Supply | 24 V DC (optional 100–240 V AC adapter) |
| Certification | CE, ETL (UL/CSA/VDE/Semco), RoHS, FDA-compliant |
| Laser Class | 3B (IEC 60825-1) |
| Warranty | 60 million pulses or 2 years (120 million / 3 years optional) |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | MNL103HP |
| Output Wavelength | 337.1 nm |
| Pulse Energy (typ., after 100M shots) | 225 µJ |
| Pulse Width | 3 ns |
| Max. Repetition Rate | 30 Hz |
| Beam Divergence | 3.5 × 3 mrad (Pulse) / 0.5 × 0.3 mrad (LD-Version) |
| Energy Stability (SD/E) | ≤ 2% |
| Timing Jitter (ext. trigger to optical pulse) | ±2.5 ns |
| Beam Size | 3 × 4 mm² (Pulse) / 4 × 2.5 mm² (LD-Version) |
| Operating Voltage | 220 V AC, no external gas or water cooling required |
| Lifetime Rating | 60M / 120M shots |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | MNL300 |
| Laser Type | Pulsed Gas Laser (Nitrogen) |
| Wavelength | 337.1 nm |
| Pulse Energy | up to 85 µJ @ 20 Hz |
| Max. Repetition Rate | 80 Hz |
| Pulse Width | 3 ns |
| Average Power | 5 mW |
| Beam Dimensions | 3 × 4 mm |
| Beam Divergence | ≤3.5 × 3.5 mrad |
| Energy Stability | ≤2% RMS |
| Timing Jitter | ±5 ns |
| Sync Output Jitter | <0.2 ns |
| Trigger Input | Optical or TTL Electrical |
| Cooling | Air-cooled |
| Power Supply | 24 V DC, 60 W |
| Certifications | CE, ETL (ANSI/UL 61010-1, CAN/CSA C22.2#61010-1), FDA-compliant |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | MNL330 |
| Laser Type | Pulsed UV Gas Laser (N₂) |
| Wavelength | 337.1 nm |
| Pulse Energy | up to 40 µJ (typ. 15 µJ @ 300 Hz) |
| Repetition Rate | up to 300 Hz |
| Pulse Width | 3 ns (FWHM) |
| Spectral Bandwidth | ≤ 0.1 nm |
| Beam Dimensions | 1.5 × 2 mm |
| Beam Divergence | ≤ 3.5 × 3.5 mrad |
| Energy Stability | ≤ ±2% (RMS, over 8 hrs) |
| Timing Jitter (Ext. Trigger → Pulse) | ±5 ns |
| Pulse Delay (Ext. Trigger → Pulse) | 1600 ns ±10% |
| Sync Output Jitter (Optional) | < 0.2 ns |
| Power Supply | 24 V DC, 60 W (with optional 100–240 V AC, 50–60 Hz adapter) |
| Cooling | Air-cooled |
| Laser Class | 3B (IEC 60825-1) |
| Lifetime | ≥ 200 million pulses or 2 years (whichever occurs first) |
| extended warranty option | 120 million pulses / 3 years |
| Dimensions (L×W×H) | 300 × 87 × 87 mm |
| Net Volume | 2.2 L |
| Compliance | CE, RoHS, EN 60825-1, EN 61000-6-3/6-4 |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | UDL |
| Core Technology | Pulsed Dye Laser with Intracavity SHG |
| Pump Compatibility | MNL-series N₂ lasers (337 nm), excimer lasers (308/351 nm), frequency-doubled Nd:YAG (355/266 nm) |
| Tuning Range | 400–950 nm (fundamental), 225–400 nm (SHG) |
| Output Bandwidth | UDL100: 5–8 nm |
| UDL200 | ≤2 nm |
| Conversion Efficiency | up to 30% (UDL100, dye only), 6% (UDL200 + SHG) |
| Repetition Rate | up to 50 Hz |
| Beam Diameter | 1.5 mm |
| Beam Divergence (v × h) | 1 × 2 mrad |
| Dimensions | 115 × 250 × 170 mm |
| Weight | 1.5 kg |
| Warranty | 1 year |
| Brand | Meadowlark Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HoloTweezer™ |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MyBrix |
| Product Type | Handheld Refractometer |
| Display | Digital |
| Measurement Range | 0–95 °Brix |
| IP Rating | IP65 |
| Temperature Compensation | Automatic (ATC) |
| Prism Design | Shallow, Easy-Clean Geometry |
| Battery Life | Up to 10,000 measurements |
| Predefined Scales | 10 built-in scales (3 simultaneously active) |
| Weight (with batteries) | 115 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito 30PX |
| Product Type | Handheld Density Meter |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0 to 2 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Temperature Range | 5–35 °C |
| Temperature Resolution | ±0.1 °C |
| Units Supported | Density, Specific Gravity (SG), Alcohol % v/v, Brix %, API Gravity, Baumé, Plato, H₂SO₄ (w/w%), and User-Defined Units |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy R40/Brix/Bev |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, active heating & cooling |
| Display | Digital LCD |
| Refractive Index Range | 1.3200–1.5800 nD |
| Built-in Performance Verification | SimpleCheck™ certified reference standards |
| Compliance | Designed for GLP/GMP environments with audit-ready verification workflow |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.30–1.72 |
| Measurement Accuracy | ±0.0001 |
| Resolution | 0.0001 |
| Brix Range | 0–100% w/w |
| Brix Accuracy | ±0.05 (at ~10–80% w/w) |
| Temperature Range | 10–65 °C |
| Temp. Accuracy | ±0.1 °C |
| Supported Units | nD, % Brix, °Oechsle, °Babo, HFCS-42/55, Invert Sugar, Custom Concentration Tables, Freeze Point Depression |
| Preloaded Methods | Up to 66 |
| Auto Sample Detection (FastStart™) | Yes (on Easy Brix & EaSy R4O) |
| Minimum Sample Volume | 0.2 mL (Easy Brix), ~50 µL (EaSy R4O), 0.2 mL (Easy Bev) |
| Dimensions (W×H×D) | 170×156×273 mm (Easy Brix), 198×382×200 mm (EaSy R4O), 170×156×273 mm (Easy Bev) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index (nD) Range | 1.3200–1.7000 |
| Brix Range | 0–100% w/w |
| nD Accuracy | ±0.0001 (near calibration point), ±0.00002–±0.00004 (full range) |
| nD Repeatability | ±0.00005 (R4), ±0.00001 (R5) |
| nD Resolution | 0.0001 (R4), 0.00001 (R5) |
| Brix Accuracy | ±0.05% (R4), ±0.014% (R5) |
| Brix Repeatability | ±0.05% (R4), ±0.01% (R5) |
| Temperature Range | 5–100 °C (R4), 5–75 °C (R5) |
| Temp. Accuracy | ±0.1 °C (5–100 °C, R4), ±0.03 °C (15–50 °C, R5), ±0.05 °C (5–75 °C, R5) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0–100 % w/w (Brix or refractive index equivalent) |
| Accuracy | ±0.05 % w/w |
| Compliance | FDA 21 CFR Part 11 ready (with LabX software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro 8600 |
| Measurement Range | 0–100 EBC / 0–400 FTU |
| Process Connection | Inline sanitary sleeve (Varivent®-compatible) |
| Wetted Materials | 316L stainless steel, sapphire optics |
| Operating Temperature | 0–80 °C (standard), up to 120 °C (short-term) |
| Operating Pressure | 1–16 bar |
| Optical Detection Angles | 25° and 90° scattering |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Industrial Online Turbidimeter |
| Measurement Principle | Backscatter & Forward/90° Scatter Optical Detection |
| Sensor Types | InPro8200 (Dual-Fiber Backscatter), InPro8300RAMS (Flow-Cell Forward/90° Scatter) |
| Compliance | Designed for FDA 21 CFR Part 11, GMP/GLP environments, ASTM D6506, ISO 7027 |
| Installation Options | Reactor-mounted, Pipe-threaded (DIN/ISO/NPT), Sanitary Clamp (Tri-Clamp®), Flow Cell |
| Output Signal | 4–20 mA, HART®, Modbus RTU/TCP, EtherNet/IP™ |
| Enclosure Rating | IP66/IP68 (InPro8200), IP69K (InPro8300RAMS) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro8200 |
| Measurement Principle | Backscatter Optical Detection |
| Optical Path | Dual-Fiber Configuration |
| Measuring Range | 5–4000 FTU, 0–30 g/L (cell density) |
| Probe Length Options | 120 / 205 / 297 / 407 mm |
| Wetted Materials | ASTM A240 UNS S31603 (316L stainless steel) or UNS N10276 (Hastelloy C-276) |
| Process Connection | Pg 13.5 thread |
| Max. Operating Pressure | 16 bar (232 psi) |
| Window Material | Epoxy-sealed optical window |
| Fiber Optic Cable | Fixed 3 m dual-fiber cable with 2 FC/PC connectors |
| Probe Diameter | 12 mm |
| Compliance | Designed for GMP/GLP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro8400 |
| Measurement Principle | 12° forward scatter + direct transmission |
| Optical Window Material | Sapphire |
| Wetted Materials | Stainless steel (316L), sapphire, FDA-compliant polymer gasket |
| Process Connections | DIN, ANSI, APV, NPT, milk union, Tuchenhagen Varivent, Neumo BioControl, Tri-Clamp |
| Pressure Rating | 1–16 bar (14.5–232 psi) |
| Particle Detection Threshold | ≥ 0.3 µm |
| Calibration Units | FTU, EBC, ppm, g/L |
| CIP-Compatible | Yes |
| Compliance | FDA 21 CFR Part 11 ready (with appropriate software configuration), meets ISO 7027 and ASTM D6506 requirements for turbidity measurement |
