| Brand | Quantel |
|---|---|
| Origin | France |
| Product Type | Diode-Pumped Solid-State (DPSS) Laser System |
| Model Series | Q-Smart |
| Wavelength Options | 1064 nm, 532 nm, 355 nm, 266 nm, 213 nm |
| Pulse Energy (1064 nm) | 300 mJ / 200 mJ / 650 mJ |
| Pulse Energy (532 nm) | 160 mJ / 95 mJ / 360 mJ |
| Pulse Energy (355 nm) | 90 mJ / 60 mJ / 200 mJ |
| Pulse Width (1064 nm) | 5–9 ns |
| Pump Source Warranty | 2 years or 2 billion shots |
| Cavity Options | Gaussian or Stable Resonator |
| Cooling | Water-cooled |
| Modularity | Fully modular laser head and power supply architecture |
| Beam Orientation Flexibility | Omnidirectional mounting (including suspended configuration) |
| Control Interface | Remote touchscreen handle with plug-and-play connectivity |
| Phase Matching | Automatic, alignment-free harmonic generation |
| Brand | Quantel |
|---|---|
| Origin | France |
| Model Series | Ultra, CFR |
| Laser Type | Flashlamp-Pumped Q-Switched Nd:YAG |
| Wavelength Options | 1064 nm, 532 nm, 355 nm, 266 nm, 213 nm, 1570 nm |
| Cooling | Air-Cooled |
| Operation Mode | Q-Switched Pulsed |
| Pulse Energy Range | Up to Several Hundred mJ (Model-Dependent) |
| Repetition Rate | 1–20 Hz (Configurable) |
| Beam Quality | TEM₀₀ (Diffraction-Limited, M² < 1.3) |
| Stability | < ±1% RMS Pulse Energy Over 8 Hours |
| Environmental Rating | IP54 Equivalent |
| Compliance | CE, RoHS, IEC 60825-1:2014 (Class 4 Laser Product) |
| Brand | Auniontech (Distributor) |
|---|---|
| Origin | Lithuania |
| Laser Type | Diode-Pumped Solid-State Q-Switched Laser |
| Pulse Duration | 2–5 ns |
| Repetition Rate | Up to 100 Hz |
| Pulse Energy | Up to 40 mJ (1163/1177 nm), 20 mJ (1300/1317 nm), 30 mJ (1551/1571 nm) |
| Average Power | Up to 1 W |
| Cooling | Air-Cooled |
| Pump Diode Lifetime | >2 Gshots |
| Optional Harmonic Generators | SHG, THG, FHG (H-SMART series) |
| Compliance | CE, RoHS, IEC 60825-1:2014 Class 4 Laser Product |
| Brand | Radiant Vision Systems |
|---|---|
| Origin | USA |
| Model | SIG-400 |
| Application | Near-field radiometric and photometric characterization of small light sources |
| Compatible Detector | ProMetric® imaging colorimeters and photometers |
| Output Format | Radiant Source Model™ (RSM), IES, EULUMDAT, ASAP, LightTools, TracePro, Zemax-compatible ray sets |
| Software Platform | ProSource® v5.0+ |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | NFMS0400 / FPMS0400 |
| Type | Near-Field Measurement System for Luminaires |
| Compliance | Supports IESNA LM-79, CIE S 025, ISO/CIE 19476 |
| Software Platform | TrueTest™ v7.0+ |
| Detector Options | ProMetric® Y-series (luminance) and I-series (chromaticity) imaging photometers |
| Angular Range | ±90° in azimuth, ±90° in elevation |
| Spatial Resolution | Up to 9M pixels per image |
| Dynamic Range | ≥1,000,000:1 (typical with HDR acquisition) |
| Calibration Traceability | NIST-traceable luminance & chromaticity standards |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | PM-1200 Series |
| Sensor Type | 12-bit CCD with CIE-matched optical filters |
| Measurement Capabilities | Luminance (cd/m²), Illuminance (lux), Radiance (W/sr·m²), Irradiance (W/m²), Luminous Intensity (cd), Radiant Intensity (W/sr) |
| Spatial Resolution | Up to 2.3 megapixels (configurable by model variant) |
| Dynamic Range | >1,000,000:1 (with electronic exposure control) |
| Compliance | ISO/CIE-compliant photometric and radiometric calibration traceable to NIST |
| Software Platform | ProMetric® v3.x or later (supports ASTM E308, CIE 15:2018, IEC 62368-1, and MIL-STD-3009 NVIS requirements) |
| Brand | REA |
|---|---|
| Origin | Germany |
| Model | PC-Scan/LD4 |
| Compliance | ISO/IEC 15416, ISO/IEC 15426-1, GS1 General Specifications |
| Laser Wavelength | 670 nm (Class II) |
| Illumination Angle | 45° |
| Measurement Angle | 90° |
| Aperture Options | 4/6/8 mil (0.1/0.15/0.2 mm) or optional 10/20 mil (0.25/0.50 mm) |
| Accuracy | ±3% (mean reflectance), ±6% (minimum reflectance), ±5% (contrast) |
| Scan Width | 133 mm or 220 mm (selectable) |
| Embedded System | ARM9 32-bit CPU, 32 MB RAM, 32 MB Flash, Linux OS |
| Interface | RJ45 Ethernet |
| Dimensions | 281 × 89 × 92 mm or 381 × 89 × 92 mm |
| Weight | 1580 g or 1820 g |
| PC Requirements | Windows 7/8.1/10/11 |
| Brand | REA |
|---|---|
| Origin | Germany |
| Model | VeriCube |
| Compliance | ISO/IEC 15415, ISO/IEC TR 29158 (AIM DPM-1-2006), ISO/IEC 15416, ANSI X3.182 |
| Light Source | 660 nm red LED or 4000 K white LED |
| Illumination Angle | 45° |
| Camera | Interchangeable CMOS module, 2592 × 1944 pixels |
| FOV Ranges | 114 × 71 mm to 9 × 6 mm (focal lengths: 8–50 mm) |
| Minimum X-dimension | 0.036 mm (at 50 mm lens) |
| Pixel Size | 3.6–44 µm |
| Measurement Cavity | Light-tight enclosure |
| Operating Positions | Horizontal (sideways), vertical, inverted |
| Code Support | DataMatrix, QR, MicroQR, Aztec, PDF417, EAN-13, UPC-A/E, ITF-14, Code 128, GS1 DataBar, and >20 additional 1D symbologies |
| Calibration | Factory pre-focused and aperture-optimized |
| Included Accessories | White reference plate, symbol calibration target, power supply, USB drive, manual |
| Brand | Rhopoint |
|---|---|
| Origin | United Kingdom |
| Model | Novo-Shade Duo+ |
| Reflectance Repeatability | 0.2% |
| Reflectance Accuracy | ±0.1 |
| Measurement Geometry | 0°/45° |
| Display | Full-color LCD with adjustable brightness |
| Interface | 6 capacitive touch keys |
| Construction | Anodized aluminum housing, tempered glass front panel, integrated calibration stand with position detection |
| Data Storage | 8 MB (up to 999 readings), user-definable batch names |
| Connectivity | Bluetooth 4.2, USB Type-A (driver-free PC connection) |
| Battery | Rechargeable Li-ion, ≥17 hours continuous operation, ≥20,000 measurements per charge, 4-hour full recharge |
| Operating Environment | 15–40 °C, ≤85% RH non-condensing |
| Dimensions | 65 mm (H) × 140 mm (L) × 50 mm (W) |
| Weight | 790 g |
| Compliance | ISO 2814, ISO 6504, BS 3900-D4 & D7, ASTM E97, E1347, D4214, D2805, D589 |
| Brand | RJS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D4000 |
| Pricing | Available Upon Request |
| Brand | Roadvista |
|---|---|
| Origin | USA |
| Model | ROADVISTA 932 |
| Measurement Range | 0–20,000 cd·lx⁻¹·m⁻² |
| Measurement Accuracy | ±0.001% (RA) |
| Incident Angle Adjustment | −45° to +45° (continuous) |
| Observation Angle Adjustment | 0.2° to 2.0° (continuous) |
| Aperture Angle (Source & Detector) | 0.1° |
| Test Area Diameter | 25 mm |
| Colorimetric Compliance | CIE 1931 xy chromaticity coordinates (retroreflected) |
| Data Storage Capacity | >32,000 measurements |
| Interface | USB 2.0 + Bluetooth 4.2 |
| Power Supply | Removable 12 VDC, 2.4 Ah Li-ion battery |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Dimensions | 380 × 115 × 325 mm |
| Weight | 2.9 kg (with battery) |
| Standards Compliance | ASTM E1709, ASTM E2540, ASTM D4956, EN 12899, EN 471, ANSI/ISEA 107, ISO 20471, GB/T 28648, GB 20653, GB/T 28468–2012 |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | AUTOPOL 589 |
| Measurement Wavelength | 589 nm |
| Wavelength Switching | Manual or Optional Motorized |
| Measurement Range | ±225°Z |
| Resolution | 0.01°Z |
| Optical Element | Calcite Prism |
| Temperature Control Accuracy | ±0.1°C |
| Calibration | One-Touch Auto-Calibration |
| Measurement Modes | Sucrose Concentration (°Z), Optical Rotation (°), Purity, User-Defined Units |
| Compliance | SPRI Certified |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | AUTOPOL 880 |
| Measurement Wavelengths | 589 nm and 880 nm |
| Wavelength Switching | Automatic |
| Optical Rotation Range | ±225°Z |
| Resolution | 0.01°Z |
| Optical Element | Calcite Prism |
| Temperature Control Range | 20–40 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration | One-Touch Auto-Calibration |
| Measurement Modes | Sucrose Concentration (°Z), Specific Rotation (°), Purity, or User-Defined Parameters |
| Sample Type | Non-Destructive Analysis |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Autopol I |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (Integrated Peltier or Ambient Compensation) |
| Digital Display | Yes |
| Light Source | Halogen Lamp |
| Measurement Range | ±89.99° arc (Optical Rotation), ±999.99° arc (Specific Rotation), 0–99.9% (Concentration) |
| Measurement Resolution | 0.001° arc |
| Measurement Accuracy | ±0.004° arc |
| Wavelength Options | 365, 405, 436, 546, 589, 633 nm (Custom Wavelengths Available) |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Autopol II |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (Integrated Peltier-based thermal regulation) |
| Digital Display | Yes (Color LCD touchscreen interface) |
| Light Source | Tungsten-halogen lamp (≥2000 h lifetime) |
| Measurement Range | Optical Rotation ±89.99° arc, Specific Rotation ±999.99° arc, Concentration 0–99.9% w/w |
| Measurement Precision | 0.001° arc |
| Measurement Accuracy | ±0.003° arc |
| Wavelength Options | 365, 405, 436, 546, 589, and 633 nm (custom wavelengths available on request) |
| Polarizer Material | Natural calcite crystal |
| Calibration | Internal automated calibration routine with NIST-traceable quartz control plates (–80° to +80° arc) |
| Sample Cell Compatibility | 10–200 mm pathlength, 0.02–15 mL volume |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | Autopol III |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (Integrated Peltier-controlled sample compartment) |
| Display | High-resolution color LCD touchscreen (Windows Embedded OS) |
| Light Source | Tungsten-halogen lamp (≥2000 h lifetime) |
| Optical Elements | Natural calcite polarizer and analyzer (thermally stable, humidity-insensitive) |
| Measurement Modes | Optical rotation (α), specific rotation ([α]), concentration (% w/v), International Sugar Scale (ISS) |
| Measurement Range | Optical rotation ±89.99° arc, specific rotation ±999.99° arc, concentration 0–99.9% w/v |
| Accuracy | ±0.002° arc |
| Standard Resolution | 0.001° arc (0.0001° arc optional with high-stability mode) |
| Wavelength Options | 365, 405, 436, 546, 589 (Na-D), 633 nm (additional wavelengths available on request) |
| Calibration | Fully automated internal calibration using certified quartz control plates (–80° to +80° arc) |
| Sample Cell Compatibility | Standard cells from 10 mm to 200 mm pathlength |
| Compliance | Designed for GLP/GMP environments |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | Autopol IV |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (10–40 °C) |
| Digital Display | Yes |
| Light Source | Tungsten-Halogen Lamp |
| Measurement Range | ±89.99° Arc, 0–99.9% concentration |
| Measurement Resolution | 0.0001° Arc, 0.0001% concentration |
| Accuracy | ±0.002° Arc |
| Wavelength Options | 365, 405, 436, 546, 589, 633 nm (custom wavelengths available) |
| Sample Cell Compatibility | 10–200 mm pathlength, 0.02–15 mL volume |
| Calibration Standards | Certified quartz control plates (−80° to +80° Arc) |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Autopol V |
| Product Type | Automatic Polarimeter |
| Temperature Control | Built-in Semiconductor Thermostat (10–40 °C, ±0.1 °C accuracy) |
| Display | Digital LCD Interface |
| Light Source | Halogen Lamp (>2000 h lifetime) |
| Measurement Range | ±89.99° arc, 0–99.9% concentration |
| Resolution | 0.0001° arc |
| Accuracy | ±0.002° arc (full scale) |
| Wavelength Options | 365, 405, 436, 546, 589, 633 nm (custom wavelengths available) |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Autopol V Plus AutoFill |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (Peltier-controlled sample chamber) |
| Digital Display | Yes (Integrated high-contrast capacitive touchscreen) |
| Light Source | Tungsten-halogen lamp (589.3 nm nominal, Na-D line stabilized) |
| Measurement Range | ±89° arc (optical rotation), 0–99.9% w/w concentration (for sucrose or user-defined calibration) |
| Measurement Precision | ±0.001° arc (repeatability, std. dev.) |
| Measurement Accuracy | ±0.002° arc (full-scale traceable to NIST-certified quartz control plates) |
| AutoFill Function | Integrated pneumatic/hydrostatic sample handling with bubble-free filling, automated rinse (solvent-selectable), and dry-air purge cycle |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | AUTOPOL V Plus |
| Product Type | Automatic Polarimeter |
| Temperature Control | Built-in semiconductor Peltier control (10–40 °C) |
| Display | 10.4″ capacitive touchscreen |
| Light Source | Halogen lamp (≥2000 h lifetime) |
| Polarizer | Natural calcite crystal |
| Measurement Range | ±89.99° arc |
| Concentration | 0–99.9% |
| Accuracy | ±0.002° arc (full scale) |
| Resolution | 0.001° arc |
| Wavelength Options | 365, 405, 436, 546, 589, 633 nm (8 wavelengths configurable) |
| Sample Transmittance Limit | Down to 0.01% |
| Calibration Standards | NIST-traceable quartz control plates (−80° to +80° arc) |
| Compliance | 21 CFR Part 11–ready with electronic signature, audit trail, and secure user authentication |
| Cell Material | Hastelloy™ (acid/alkali resistant) |
| Thermostatic Chamber | SilcoSteel™-coated |
| Interfaces | 4× USB, 2× RS-232, 1× CAT5 Ethernet |
| Storage | 2 GB internal memory |
| Software | Windows-based method management, cGMP/GLP-compliant reporting (PDF/Excel export), customizable templates with logo/company metadata |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | AUTOPOL VI |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (Peltier-based, 10–40 °C, ±0.1 °C) |
| Display | 10.4″ color TFT touchscreen (800×600, Windows 7 embedded) |
| Light Source | Halogen lamp (6 V/20 W, >2000 h lifetime) |
| Measurement Range | Optical Rotation: ±89.99° arc |
| Specific Rotation | ±999.99° arc |
| Concentration | 0–99.9% |
| Resolution | 0.0001° arc (optical rotation) |
| Accuracy | ±0.0003° arc at 589 nm (high-accuracy mode) |
| Wavelength Options | 365, 405, 436, 546, 589, 633 nm (custom wavelengths available) |
| Sample Cell Compatibility | Up to 200 mm pathlength |
| Calibration | NIST-traceable quartz control plates (A700T-2-1, −80 °C to +80 °C), dual-mode auto-calibration with certified standard tubes (0.0001° accuracy) |
| Compliance | Fully compliant with FDA 21 CFR Part 11 (electronic signatures, audit trail, role-based access control), GLP/GMP-ready |
| Interfaces | 4× USB, 2× RS-232, 1× CAT-5 Ethernet (LIMS-integrated) |
| Transmittance Limit | Measures samples down to 0.01% transmittance |
| Certifications | IQ/OQ/PQ documentation included |
| Dimensions | 91.44 × 48.26 × 45.72 cm |
| Weight | Approx. 45 kg |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J-Series Refractometer Module |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes (Dual-zone semiconductor Peltier) |
| Digital Display | Yes (10.4" color TFT touchscreen) |
| Measurement Range | 1.26–1.72 RI, 0–100 Brix |
| Measurement Resolution | 0.00001 RI |
| Accuracy | ±0.00002 RI, ±0.015 Brix |
| Temperature Control Range | 10–110 °C (120 °C optional) |
| Temperature Stability | ±0.01 °C |
| Prism Material | Sapphire |
| Interface | RS-232, USB, Cat5 Ethernet |
| Compliance | NIST-traceable calibration standards available |
| Design | Modular split architecture (separate measurement head and control unit) |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J157 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.33–1.53 RI, 0–100 °Brix |
| Measurement Accuracy | ±0.00002 RI, ±0.01 °Brix |
| Resolution | 0.00001 RI, 0.01 °Brix |
| Wavelength | 589.3 nm (Na-D line), optional alternate wavelengths available |
| Temperature Control Range | 10–90 °C |
| Temperature Stability | ±0.01 °C |
| Sample Interface Options | Dropper, Flow Cell, and Pour-in Configurations |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J257 |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.26–1.72 RI, 0–100 °Brix |
| Measurement Accuracy | ±0.0001 RI, ±0.1 °Brix |
| Resolution | 0.00001 RI, 0.01 °Brix |
| Wavelength | 589.3 nm (Na-D line), optional alternate wavelengths available |
| Temperature Control Range | 10–100 °C (extended range: –5 to 110 °C) |
| Temperature Stability | ±0.01 °C |
| Prism Material | Sapphire (diameter > 20 mm) |
| Interface | RS-232, USB, Cat5 Ethernet |
| Storage | 32 GB internal memory |
| Display | 8-inch color touchscreen |
| Operating System | Windows 7 Embedded |
| Compliance Options | FDA 21 CFR Part 11 audit trail & electronic signature support (optional) |
| Software Features | SmartMeasure™ real-time measurement validation, Load-N-Go™ rapid sample loading, Easy Clean™ flat-cell design, Trend Analysis for QC monitoring, LIMS integration capability |
| Calibration Modes | Single-point, two-point, and multi-point calibration |
| Certified Reference Materials | NIST-traceable standards available |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J357 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Yes (Peltier-based, 10–100 °C standard, –5 to 110 °C optional) |
| Digital Display | Yes (8-inch color TFT touchscreen) |
| Measurement Range | 1.26–1.72 RI, 0–100 °Brix |
| Measurement Accuracy | ±0.00002 RI, ±0.015 °Brix |
| Measurement Resolution | 0.00001 RI, 0.01 °Brix |
| Wavelength | 589.3 nm (Na-D line), optional alternate wavelengths available |
| Prism Material | Sapphire (≥20 mm diameter) |
| Calibration Options | Single-, dual-, and multi-point calibration |
| Data Storage | 32 GB internal memory |
| Connectivity | RS-232, USB, Cat5 Ethernet |
| Software Compliance | Optional 21 CFR Part 11 audit trail & electronic signature support |
| Operating System | Windows 7 Embedded |
| LIMS Integration | Yes |
| Smart Measurement Technology | SmartMeasure™ |
| Sample Handling | Load-N-Go™ automated sample introduction |
| Cleaning Design | Easy Clean™ flat-cell geometry |
| Regulatory Standards Support | NIST-traceable reference materials available |
| Trend Analysis | Real-time QC data visualization and statistical trending |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J457 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes (Peltier dual-zone) |
| Digital Display | Yes |
| Measurement Range | 1.26–1.72 RI, 0–100 °Brix |
| Measurement Resolution | 0.000001 RI, 0.01 °Brix |
| Accuracy | ±0.000002 RI, ±0.015 °Brix |
| Temperature Control Range | 10–110 °C (120 °C optional) |
| Temperature Stability | ±0.01 °C |
| Prism Material | Sapphire |
| Display | 10.4″ color TFT touchscreen |
| Interface | RS-232, USB, Cat5 Ethernet |
| Compliance | NIST-traceable calibration standards available |
| Enclosure Rating | IP65-rated for dust and water resistance |
| Configuration | Modular split-system (remote sensor head + control unit) |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J47 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.33–1.53 RI, 0–100 °Brix |
| Measurement Accuracy | ±0.00002 RI, ±0.01 °Brix |
| Resolution | 0.00001 RI, 0.01 °Brix |
| Wavelength | 589.3 nm (Na-D line), optional alternate wavelengths available |
| Light Source | LED (>100,000 h lifetime) |
| Calibration | 1-, 2-, or multi-point |
| Interface | USB |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J57-VT |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.33–1.53 RI, 0–100 °Brix |
| Measurement Accuracy | ±0.00002 RI, ±0.01 °Brix |
| Resolution | 0.00001 RI, 0.01 °Brix |
| Wavelength | 589.3 nm (Na-D line, other wavelengths optional) |
| Temperature Control Range | 10–65 °C |
| Temperature Stability | ±0.01 °C |
| Compliance | ASTM D1218, ISO 2163, USP <781>, AOAC 932.12 |
| Brand | ADVANTEC (Yan Dongyang) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 185LE-AL |
| Light Source | DC 17 V / 185 W Senor & Burns OEM Halogen Lamp |
| Max Illuminance | ≥400,000 lx at 310 mm working distance, 55 mm Ø spot (with 10 mm aperture) |
| Illuminance Control | Continuous dimming down to ≤20% of maximum |
| Cooling | Forced-air (integrated fan in lamp housing) |
| Operating Temperature | 0–40 °C |
| Input Power | AC 95–260 V, 50/60 Hz |
| Dimensions (Lamp Housing) | 136 mm H × 112 mm W × 150 mm D |
| Weight (Lamp Housing) | 2.3 kg |
| Compliance | Designed for ISO 3664:2009-compliant visual inspection environments |
| Brand | S+H (Schmidt+Haensch) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Benchtop Refractometer |
| Display | Digital LCD & Optional 7-inch Touchscreen |
| Measurement Range | 1.32000–1.58000 RI / 0–100 %Brix |
| Resolution | 0.00001 RI / 0.01 %Brix |
| Accuracy | ±0.00002 RI / ±0.02 %Brix |
| Sample Volume | 0.3 mL |
| Temperature Compensation | Built-in NTC sensor with automatic compensation (no external thermostat required) |
| Optical System | Sapphire prism assembly with birefringence-corrected design |
| Detector | High-sensitivity CCD imaging sensor |
| Interfaces | USB, RS232, Ethernet (LAN) |
| Compliance | ISO 21648, ASTM D1218, USP <851>, GLP-compliant data logging |