Optical Measurement Instruments
Filter
Showing 61–90 of 746 results
| Brand | 3nh |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Illuminant | LED-based full-spectrum illumination |
| Spectral Range | 360–780 nm |
| Repeatability (Reflectance) | ≤0.04% std dev (400–700 nm, Φ25.4 mm, SCI mode) |
| Repeatability (Colorimetric Values) | ΔE*ab ≤0.01 (Φ25.4 mm, SCI, after warm-up & calibration, 30 measurements of white tile at 5 s intervals) |
| Repeatability (Transmittance) | ≤0.05% std dev (400–700 nm, Φ25.4 mm, SCI mode) |
| Repeatability (Transmitted Color) | ΔE*ab ≤0.02 (Φ25.4 mm, SCI, same conditions) |
| Measurement Modes | Reflectance (D/8°), Transmittance (D/0°), with UV-included and UV-excluded options |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | AR4 |
| Product Type | Benchtop Abbe Refractometer |
| Temperature Control | Yes |
| Digital Display | No |
| Measurement Range | 1.3000 – 1.7000 nD |
| Accuracy | ±0.0002 nD |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | DR301-95 |
| Sample Measurement Range | 1.3330–1.5318 nD |
| Measurement Accuracy | ±0.00015 nD |
| Temperature Range | 5–40 °C |
| Temperature Accuracy | ±0.5 °C |
| Resolution | 0.0001 nD |
| Display | Digital LCD |
| Power Supply | 9 V battery (detachable AC adapter optional) |
| Prism Material | Optical glass |
| Housing Material | Stainless steel sample stage + polymer body |
| Dimensions | 180 × 100 × 60 mm |
| Weight | 500 g |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | DR6000 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 10–80 °C (±0.1 °C) |
| Digital Display | Yes |
| Refractive Index Range | nD 1.3200–1.5800 (standard), up to 1.7000 with extended Brix mode |
| Accuracy | ±0.0001 nD |
| Resolution | 0.0001 nD |
| Brix Range | 0–95 % |
| Brix Accuracy | ±0.1 % |
| Brix Resolution | 0.1 % |
| Prism Material | Sapphire |
| Light Source | 590 nm LED (>100,000 h lifetime) |
| Measurement Time | ~4 s |
| Interface | RS-232, USB, Ethernet |
| Data Storage | Integrated SQL database (99 methods, 999 results) |
| Compliance | GLP, FDA 21 CFR Part 11 ready, ICUMSA-compliant temperature compensation |
| IP Rating | IP65 (measurement cell) |
| Power Supply | 90–260 V AC, 50/60 Hz, 60 W |
| Operating Ambient | 15–35 °C |
| Sample Temp Range | 10–80 °C |
| Temperature Sensor | PT100 |
| Display | 5.7″ LCD (320 × 240 px), touchscreen |
| Brand | A.L.S. GmbH / Advanced Laser Diode Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DiLas DD50-2 |
| Core Components | Fiber-Coupled Semiconductor Laser Module, Integrated Laser Driver & TEC Controller, Active Air-Cooled Heat Sink |
| Max Output Current | 50 A |
| Max Output Voltage | 3–6 V (configurable) |
| Pulse Rise Time | 100 µs |
| Operating Modes | CW and Pulsed |
| Wavelength Options | 808 nm, 940 nm, 980 nm |
| Fiber Coupling | SMA905 connector, 400 µm or 600 µm core diameter |
| Thermal Load Capacity | Up to 120 W (HS 120) |
| TEC Integration | Integrated Peltier element with temperature sensor and active fan cooling |
| Control Interface | Front-panel keypad + RS232 |
| Analog Modulation | Supported (50 A version only) |
| Brand | A2PS/A2 Photonic Sensors |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | POP |
| Pricing | Available Upon Request |
| Brand | TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | WSY-5 |
| Pricing | Upon Request |
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | Optical Tweezers System |
| Laser | 1064 nm, 1 W, TEM₀₀ mode |
| XY Stage | Motorized, 10 mm travel, 2.5 µm resolution, manual joystick control |
| Z Axis | Manual adjustment, 10 mm travel, 2.5 µm resolution |
| Illumination | White LED, 5000 K CCT, 1100 mW output, 350–700 nm spectral range, 100 mm working distance, LEC1-B controller |
| Brand | Acclima, Inc. |
|---|---|
| Origin | USA |
| Model | TDR310H |
| Volumetric Water Content (VWC) | 0–100% (0.1% resolution |
| Soil Temperature | −40 to +60 °C (0.1 °C resolution |
| Dielectric Constant | 1–80 (0.1 resolution |
| Bulk Electrical Conductivity (ECb) | 0–5000 μS/cm |
| Pore Water Electrical Conductivity (ECw) | 0–55,000 μS/cm (1 μS/cm resolution |
| Response Time | 0.25 s |
| Power Supply | 3.5–15 V DC |
| Operating Current | 36 mA @ 12 V DC (typical), <10 μA idle |
| Output Interface | SDI-12 |
| Probe Length | 15 cm |
| Probe Diameter | 0.35 cm |
| Dimensions | 22.56 × 3.34 cm |
| Weight | 440 g (body only, no cable) |
| Brand | Accurion |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EP4 |
| Pricing | Upon Request |
| Brand | Accurion |
|---|---|
| Origin | Germany |
| Model | Nanofilm_EP4 |
| Spectral Range | 190–2750 nm |
| Spot Size | 1 µm |
| Angle of Incidence | 38°–90° |
| Sample Diameter | 2–12 inches |
| Spectral Resolution | 0.1 nm |
| Thickness Measurement Accuracy | 0.1 nm |
| Thickness Repeatability | 0.01 nm |
| Brand | Accurion |
|---|---|
| Origin | Switzerland |
| Model | RSE Referenced Spectroscopic Ellipsometry Fast Inspection System |
| Spectral Range | 450–900 nm |
| Spot Size | 50 × 100 µm (at 60° incidence) |
| Thickness Measurement Range | <1 nm to 10 µm |
| Acquisition Rate | 200 full spectroscopic ellipsometric spectra per second |
| Mapping Area | 100 mm × 100 mm in ≤12 min |
| Data Processing | Real-time look-up table (LUT)-based fitting |
| Compliance | Designed for ISO/IEC 17025-aligned QC environments, supports GLP/GMP traceability via audit-ready software logs |
| Brand | ACM |
|---|---|
| Origin | Austria |
| Model | LR.10 |
| Type | Online Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0–30 °Brix |
| Accuracy | ±0.005 °Brix |
| Operating Temperature | 0–50 °C |
| IP Rating | IP65 |
| Communication Interface | RS485, Profibus |
| Compliance | Designed for hygienic process environments (CIP-compatible, 10 bar pressure rating) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Asteria-Colormeters |
| Instrument Type | Benchtop Spectrocolorimeter |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Steropes LED |
| Spectral Range | 200–1100 nm |
| Repeatability | <0.5% (ΔY), 0.0002 (ΔY at low luminance) |
| Detector | Silicon Photodiode with CIE 1931 Photopic Response Matching |
| Luminance Range | 0.002–15,000 cd/m² |
| Illuminance Range | 0.01–200,000 lux |
| Sampling Rate | Up to 180,000 samples/sec |
| Internal Memory | 250,000 measurements |
| Measurement Speed | 4–100 Hz (luminance/illuminance), real-time flicker analysis |
| Operating Temperature | 10–35 °C |
| Dimensions (L×W×H) | 69×31×93 mm (body only) |
| Weight | ~0.35 kg |
| Interface | USB 2.0, RS-232 |
| Trigger Support | External TTL trigger input |
| Software Compatibility | LabVIEW, LabWindows/CVI, Visual Studio (C++, C#, VB.NET) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Atlas-Colorimeters |
| Spectral Range | 380–780 nm |
| Wavelength Resolution (FWHM) | 2.3 nm |
| Camera Options | 8 MP (3312 × 2488) or 16 MP (4872 × 3248), 12-bit output |
| Nonlinearity | < 1% |
| SNR | 60 dB |
| Exposure Time | 1 ms – 16 s |
| Integral Time (Spectrometer) | 1.4 ms – 20 s |
| Stray Light | < 0.03% |
| Lens Options | Componon-S f/4.0–f/5.6, focal lengths 80–102 mm |
| Field of View (Diagonal) | 12.6°–19.2° (depending on model & working distance) |
| Compliance | ISO/CIE photopic and colorimetric standards, NIST-traceable calibration protocols |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Cronus |
| Spectral Range | 380–780 nm |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 2.5 ms – 20 s |
| Linearity Error | < 0.5% |
| Dynamic Range (Spectrometer) | >150,000 |
| Dynamic Range (Colorimeter) | >10,000,000 |
| Luminance Measurement Speed | >50,000 readings/s |
| Colorimetric Accuracy (Y, x, y) | ±4%, ±0.002 |
| Colorimetric Repeatability (Y, x, y) | <0.5%, ±0.0002 |
| Detector | Silicon photodiodes with XYZ interference filters conforming to CIE 1931 color matching functions |
| Optical Input Options | Cosine corrector (fixed or fiber-coupled), integrating spheres (75 mm / 150 mm / 250 mm), lens systems (5 mm / 10 mm / 20 mm focal lengths) |
| Interface | High-speed USB (USBTMC-compliant), RS-232, Ethernet, external trigger I/O |
| Mechanical Shutter Lifetime | >1 million cycles |
| Operating Temperature | 10–35 °C |
| Compliance | USBTMC standard, SCPI command set |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | HERA |
| Spectral Range (Lens Mode) | 380–780 nm |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 2.5 ms – 20 s |
| Stray Light | <0.03% |
| Nonlinearity | <1% |
| Luminance Range | 0.05–6000 cd/m² |
| Wavelength Accuracy | ±0.5 nm |
| Luminance Accuracy (CIE A) | ±4% |
| Chromaticity Accuracy (CIE x,y) | ±0.002 |
| Repeatability (2σ, 250 cd/m²) | <0.3% (luminance), ±0.0005 (x,y) |
| Measurement Spot Size (20 mm lens, 50 mm WD) | 20.5 mm |
| Field of View | ±0.3° |
| Interface | High-Speed USB (USBTMC/SCPI), RS232, Ethernet, External Trigger |
| Dimensions (L×W×H, body only) | 100 × 80 × 55 mm |
| Weight | 0.35 kg |
| Operating Temperature | 10–35 °C |
| Power | 1250 mW (USB-powered) |
| Optical Configurations | Fixed lens, cosine corrector, or fiber-coupled input (HERA01–HERA04 variants) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | HYPERION 2.1 mm |
| Optical Spot Size | 2.1 mm (focused lens configuration) |
| Measurement Principle | Tristimulus CIE 1931 XYZ colorimetry |
| Luminance Range | 0.001–200,000 cd/m² (typical, dependent on integration time and lens) |
| Sampling Rate | up to 2000 samples/s for Y (luminance) flicker measurement |
| Interface | USB-TMC compliant |
| Operating Systems | Windows, Linux (x86_64, i686, ARM), macOS |
| Software Integration | Native VISA support for LabVIEW, LabWindows/CVI, Visual Studio (.NET) |
| Compliance | USB-TMC 1.0, JEITA CP-3405 (flicker), CIE S 026/E:2015 (photopic luminous efficiency), ISO/CIE 11664-1:2019 (colorimetry fundamentals) |
| Mechanical Shutter | Integrated |
| Dynamic Range | >120 dB (typical, 24-bit ADC with auto-ranging) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion_colorimeters |
| Detector | Triple silicon photodiodes with XYZ interference filters |
| Spectral Response | CIE 1931 standard observer (close match) |
| Luminance Range | 0.005–20,000 cd/m² |
| Chromaticity Accuracy (x,y) | ±0.001 (calibrated) |
| Luminance Accuracy | ±4% of reading |
| Flicker Measurement | JEITA & Contrast methods |
| Sampling Rate | Up to 40 Hz (at ≥5 cd/m²) |
| Dynamic Range | >80 dB |
| Resolution | 16-bit for X, Y, Z |
| Integration Time | 0.5 ms – 1 s |
| Optical Field of View | 5° (±2.5°) |
| Spot Size | 13.5 mm @ 50 mm WD |
| Interface | USB 2.0, RS-232 |
| Power | USB bus-powered + optional 9 V DC |
| Dimensions (w/o lens) | 53 × 70 × 147 mm |
| Weight | 670 g |
| Operating Temperature | 10–35 °C |
| Shutter Lifetime | >1 million cycles |
| Shutter Speed | 250–300 ms |
| Color Spaces | CIE XYZ, Yxy, Yu’v’, CCT, Duv, Dominant Wavelength (DWL), Flicker (%, dB) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion |
| Detection Angles | 0°, 30°, 45°, 60° |
| Spectral Response | CIE 1931-compliant XYZ tristimulus |
| Luminance Range | 0.02–20,000 cd/m² |
| Chromaticity Accuracy (x,y) | ±0.001 (post-calibration), down to ±0.0002 at 150 cd/m² |
| Flicker Measurement Speed | 2000 samples/sec (flicker mode) |
| Color Measurement Speed | ≤22 ms per acquisition |
| Dynamic Range | >80 dB |
| A/D Resolution | 16-bit (X,Y,Z) |
| Interface | USB 2.0, RS-232 |
| Operating Temperature | 10–35 °C |
| Weight | 1.5 kg |
| Dimensions (w/o lens) | 195 × 194 × 64 mm |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion Series |
| Detector | Triple silicon photodiodes with XYZ interference filters |
| Spectral Response | CIE 1931-compliant |
| Weight | 670 g |
| Dimensions (w/o lens) | 53 × 70 × 147 mm |
| Mounting | 12× M3 threaded holes |
| Power Supply | USB-powered + optional 9 V DC |
| Interfaces | USB 2.0, RS-232 |
| Measurement Parameters | XYZ, Yxy, Yu’v’, CCT, DWL, Flicker (JEITA & Contrast methods) |
| Luminance Range | 0.003–12,000 cd/m² |
| Luminance Accuracy | ±2% (at 150 cd/m², white field) |
| Chromaticity Accuracy (x,y) | ±0.001 (at 150 cd/m², white field) |
| Repeatability (Y) | ±0.1% (≥5 cd/m²) |
| Chromaticity Repeatability (x,y) | ±0.0002 (≥5 cd/m²) |
| Flicker Sampling Rate | 2000 Hz (XYZ & flicker simultaneously) |
| Minimum Detectable Flicker Frequency | 1 Hz |
| Measurement Speed | Up to 40 Hz (at ≥5 cd/m²) |
| Integration Time | 0.5 ms – 1 s |
| Dynamic Range | >80 dB |
| A/D Resolution | 16-bit per channel |
| Operating Temperature | 10–35 °C |
| Shutter Lifetime | >1 million cycles |
| Shutter Actuation Time | 250–300 ms |
| Optical Configurations | Standard 5° FOV (10 mm or 20 mm lens) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion Wide-Spectrum Series |
| Spectral Range | 200–1100 nm |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 4.8 ms – 60 min |
| Dark Noise (RMS) | ~3–5 counts (16-bit ADC) |
| Stray Light | <0.03% |
| Nonlinearity | <1% |
| Detector Cooling | Thermoelectrically cooled CCD to −10 °C |
| Optical Interface | 20 mm lens (spot size: 20.5 mm @ 50 mm WD, 21 mm @ 100 mm WD, 21.5 mm @ 150 mm WD) |
| Field of View | ±0.3° |
| Interfaces | High-Speed USB (USBTMC compliant), RS232, Ethernet, External Trigger |
| Dimensions (L×W×H) | 230 × 195 × 82.5 mm (body only) |
| Weight | 3.3 kg |
| Operating Temperature | 10–35 °C |
| Power Supply | 15 V DC (14.5–15.5 V range) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | MSE_colorimeters |
| Optical Spot Size | 10 mm (standard), 20 mm (MSE+ variant) |
| Spectral Response | CIE 1931 XYZ-matched via interference-filtered Si photodiodes |
| Measurement Speed | Up to 200 color measurements/sec @ 200 cd/m² |
| Luminance | 22,000 samples/sec |
| Dynamic Range | 0.05–3000 cd/cm² (MSE), 0.05–15,000 cd/cm² (MSE+) |
| Accuracy | Luminance Y ±0.06% (≥150 cd/m²), Chromaticity x,y ±0.0002 (≥150 cd/m², calibrated) |
| Repeatability | Y ±0.15% @ 1 cd/m² |
| Resolution | 15-bit for X,Y,Z channels |
| Integration Time | 1 ms – 5 s |
| Interface | USB 2.0, RS-232, TTL Trigger In/Out |
| Mechanical Shutter | >1 million cycles, 70–120 ms actuation |
| Operating Temperature | 10–35 °C |
| Dimensions (w/o lens) | 63 × 24 × 65 mm |
| Weight | 250 g |
| Mounting | 12× M3 threaded holes |
| Compliance | Designed for GLP/GMP-aligned manufacturing environments |
| Brand | Admesy |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PCM2-051 |
| Brightness Range | 0.0003–15,000 cd/m² (UHL mode up to 95,000 cd/m²) |
| Chromaticity Range | 0.003–15,000 cd/m² |
| Measurement Spot Size | 5 mm (at 5 mm working distance ±2 mm) |
| Field of View | ±6° |
| Sampling Rate | 2000 / 3000 / 3125 Hz |
| CIE Standard Observer | 2° CIE 1931 & CIE 170-2:2015 |
| Flicker Calculation | Internal JEITA-compliant (custom algorithms supported) |
| Shutter | Mechanical, USB-MTC compliant |
| OS Compatibility | Windows, Linux, macOS |
| Software Integration | VISA-compatible for LabVIEW, LabWindows/CVI, Visual Studio |
| Brand | Admesy |
|---|---|
| Model | PCM2-100 |
| Measurement Principle | CIE 1931 / CIE 170-2:2015 Tristimulus Matching |
| Luminance Range | 0.0003–15,000 cd/m² (UHL Mode up to 95,000 cd/m²) |
| Chromaticity Accuracy | ±0.003 Δu'v' (typ.) |
| Luminance Accuracy | ±2% (≥0.01 cd/m²), ±5% (0.0003–0.01 cd/m²) |
| Aperture Angle | 5° (±2.5°) |
| Spot Size | 18.7 mm @ 100 mm WD |
| Sampling Rate | Up to 3125 Hz (flicker mode) |
| Interface | USB 2.0 compliant with USBTMC |
| OS Support | Windows, Linux, macOS |
| Software SDK | VISA-compatible (LabVIEW, LabWindows/CVI, Visual Studio) |
| Internal Flicker Calculation | JEITA-compliant, customizable algorithm |
| Mechanical Shutter | Integrated, TTL-controlled |
| Compliance | USBTMC 1.0, CIE S 014-2/E:2016, ISO/CIE 11664-3:2018, IEC 62341-6-3 (OLED display testing) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | PCM2X-271 |
| Luminance Range | 2.5×10⁻⁵ to 3×10⁴ cd/m² |
| Chromaticity Accuracy Range | 2.5×10⁻⁴ to 3×10⁴ cd/m² |
| Sampling Rate (XYZ) | 600 kS/s |
| Field of View | ±5° |
| Spot Size | 30 mm @ 25 mm Working Distance |
| CIE Standard Observer | 2° CIE 1931 & CIE 170-2:2015 |
| Flicker Analysis | FFT-based (FMA, JEITA, user-defined), time-domain FMA (VRR), FIR-filtered |
| Shutter | Mechanical, USB-MTC compliant |
| OS Compatibility | Windows, Linux, macOS |
| Software Interface | VISA, LabVIEW, LabWindows CVI, Visual Studio |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus |
| Detector Type | Cooled CCD |
| Viewfinder Type | Pritchard Mirror-Based Camera Viewfinder |
| Interface | USB (USBTMC/SCPI), RS232, Ethernet |
| Dynamic Range | High (with内置 mechanical shutter & OD filter wheel) |
| Polarization Sensitivity | Very Low |
| Linearity Error | ±0.5% (internally compensated) |
| Dark Current Compensation | Full integration-range zero offset correction |
| Wavelength Monitoring | Integrated real-time wavelength drift correction |
| Calibration | Factory-calibrated for spectral radiance, luminance, chromaticity (CIE 1931 xy, u’v’) |
| Compliance | USBTMC, SCPI, ISO/CIE-compliant measurement architecture |
| Software Support | SDK for Python, C++, LabVIEW, MATLAB, .NET |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus LF |
| Sampling Rate | 800 kS/s |
| Photopic V(λ) Filter Compliance | CIE 1931 Standard Observer |
| Flicker Metrics | Contrast Ratio (Min/Max/RMS), JEITA, VESA |
| Operating Systems | Windows, macOS, Linux |
| API Support | VISA-compliant (LabVIEW, LabWindows/CVI, C++, C#, Python) |
| Trigger I/O | TTL-compatible input/output |
| Auto-ranging | Yes |
| User Calibration | Supported |
| Memory | High-capacity onboard buffer |
| Measurement Modes | Luminance (cd/m²), Flicker Waveform Capture, Temporal Analysis |
| Optical Aperture | 17 mm |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus X27 |
| Measurement Principle | CIE 1931 / CIE 170.2:2015-compliant photopic luminance and tristimulus colorimetry |
| Luminance Range | 0.0001–20,000 cd/m² |
| Minimum Measurement Time | 1 s (at 0.0001 cd/m²) |
| Y-Channel Sampling Rates | 3.125 kS/s, 2 kS/s, or 800 kS/s |
| Filter Accuracy | Factory-calibrated interference filters matching CIE standard observer functions |
| Compliance | CIE 1931, CIE 170.2:2015, JEITA TR-006 (flicker), USB Device Class MTC v1.0 |
| OS Compatibility | Windows, Linux, macOS |
| API Support | Native SDK for C#, C++, VB.NET, LabVIEW, MATLAB, Python |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Rhea Spectrometers |
| Spectral Range | 200–1100 nm |
| Cooling | Thermoelectrically cooled CCD (operating at –10 °C) |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 4.8 ms – 60 min |
| Dark Noise (RMS) | ~3–5 counts (16-bit ADC) |
| Stray Light | <0.03% |
| Nonlinearity | <1% |
| Optical Input | Fixed or customizable fiber coupling |
| Interface | High-speed USB (USBTMC compliant), RS232, Ethernet, TTL trigger |
| Dimensions (L×W×H) | 230 × 195 × 82.5 mm (excl. lens) |
| Weight | 3.3 kg |
| Operating Temperature | 10–35 °C |
| Power Supply | 14.5–15.5 V DC |
| Spot Size (with 20 mm lens) | 20.5 mm @ 50 mm WD, 21 mm @ 100 mm WD, 21.5 mm @ 150 mm WD |
| Field of View | ±0.3° |
| Onboard Processing | Yes |
| Neutral Density Filter Wheel | Integrated |
| Dynamic Range Enhancement | Yes |
| Linearity | Engineered for <1% nonlinearity across full intensity range |
| Compliance | USBTMC, SCPI command set, suitable for GLP/GMP-aligned data acquisition workflows |