| Brand | 2B Tech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HERMES |
| Pricing | Upon Request |
| Brand | 2B Tech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HERMES |
| Pricing | Upon Request |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106M |
| Weight | 2.1 kg (4.7 lb) |
| Measurement Principle | UV absorption at 254 nm |
| Range | 0–1000 ppmv |
| Resolution | 0.01 ppmv |
| Accuracy | ±0.01 ppmv or ±2% of reading |
| Sampling Interval | 10 s (configurable averaging: 10 s, 1 min, 5 min, 1 hr) |
| Flow Rate | ~1 L/min |
| Data Storage | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Power | 12 V DC or 120/240 V AC, 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm (3.75 × 8.25 × 8.50 in) |
| Compliance | NIST-traceable calibration, compatible with EPA reference method EQOA-0808-191 for ozone monitoring |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Model 106M |
| Weight | 2.1 kg (4.7 lb) |
| Measurement Principle | UV Absorption at 254 nm |
| Range | 0–1000 ppmv |
| Resolution | 0.01 ppmv |
| Accuracy | ±0.01 ppmv or ±2% of reading |
| Detection Limit | 1.5 ppbv |
| Sampling Interval | 10 s (configurable averaging: 10 s, 1 min, 5 min, 1 hr) |
| Flow Rate | ~1 L/min |
| Data Storage | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Analog Output Ranges | 0–1, 0–10, 0–100 ppmv (customizable) |
| Units Supported | ppb, ppm, pphm, µg/m³, mg/m³ |
| Humidity Management | Nafion® Dryer Tube (DewLine™) |
| Power | 12 V DC or 120/240 V AC, 350 mA, 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm (3.75 × 8.25 × 8.50 in) |
| Alarm Indicators | LED status for power-on, [O₃] > 100 ppb, calibration due, filter replacement required |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 714 |
| NO₂ Range | 0–500 ppb |
| NO Range | 0–1000 ppb |
| O₃ Range | 0–500 ppb |
| Output Flow | 2.0–3.5 L/min (typ. 2.5–3.0 L/min) |
| Accuracy | ±2.0 ppb or ±2.0% of reading (whichever is greater) |
| Response Time to 95% of Setpoint | <30 s |
| Power | 12 V DC, 3.5 A max (42 Wh), or 100–240 V AC, 5 A |
| Dimensions (Rack-Mount) | 43 × 37 × 14 cm (17" × 14.5" × 5.5") |
| Weight | 7.0 kg (15.5 lb) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Altitude | 0–2000 m |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 714 |
| NO₂ Range | 0–500 ppb |
| NO Range | 0–1000 ppb |
| O₃ Range | 0–500 ppb |
| Output Flow | 2.0–3.5 L/min (typ. 2.5–3.0 L/min) |
| Accuracy | ±2.0 ppb or ±2.0% of reading (whichever is greater) |
| Response Time to 95% of target concentration | <30 s |
| Power | 12 V DC / 120–240 V AC, 18 W (operational), 42 Wh (max during warm-up) |
| Dimensions (Rack-mount) | 43 cm × 37 cm × 14 cm (17″ × 14.5″ × 5.5″) |
| Weight | 7.0 kg (15.5 lb) |
| Programmable Sequences | Up to 99 stored methods, each with up to 15 steps (NO: up to 1000 ppb |
| NO₂/O₃ | up to 500 ppb) |
| Operating Temp | 0–40 °C |
| Storage Temp | −20–60 °C |
| RH | 0–80% non-condensing |
| Altitude | 0–2000 m |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA Eto |
| Pricing | Upon Request |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA OCS |
| Price | Upon Request |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL5001 |
| Detection Principle | Vacuum Ultraviolet Fluorescence (VUV) at 150 nm |
| Detection Limit | <2.0 ppb (1 s integration), <0.8 ppb (10 s integration) |
| Response Time (10–90%) | 2 s |
| Linear Range | 0–100 ppm (pulse counting mode) |
| Pump Type | Diaphragm vacuum pump |
| Interface | RS232 |
| Power Supply | 110/220 VAC or 24 VDC |
| Weight | 22 kg |
| Automation | Fully automated measurement and calibration |
| Brand | AII |
|---|---|
| Origin | USA |
| Model | GPR-1200 |
| Weight | 5.4 kg (12 lbs) |
| Measurement Range | 0–1 ppm to 0–100% O₂ |
| Accuracy | < 2% of reading or 0.2 ppm (whichever is greater) |
| Response Time (T90) | < 13 s |
| Detection Limit | 0.05 ppm |
| Sensor Lifetime | 24–32 months (at ≤1000 ppm O₂) |
| Battery Life | Up to 30 days (standby), 40 hours (with internal pump active) |
| Operating Temperature | 5–45°C (GPR sensor) |
| Enclosure | Painted aluminum, NEMA 4X rated |
| Gas Inlet | 1/8" compression fitting |
| Pressure Range | 0.34–2 barg (5–30 psig) with vent |
| Output | 0–1 V analog |
| Compliance | ATEX Ex II 2 G Ex ib IIC T4 Gb, Tamb 5°C to +45°C |
| Brand | AII |
|---|---|
| Origin | USA |
| Model | GPR-1200 |
| Weight | 5.4 kg (12 lbs) |
| Measurement Range | 0–1 ppm to 0–100% O₂ |
| Accuracy | <2% of reading or 0.2 ppm (whichever is greater) |
| Response Time (T90) | <13 s |
| Detection Limit | 0.05 ppm |
| Sensor Lifetime | 24–32 months @ 25°C / 1 atm |
| Battery Life | Up to 30 days (standby), 40 hours (with internal pump active) |
| Operating Temperature | 5–45°C (GPR sensor) |
| Enclosure | Painted aluminum, NEMA 4X rated |
| Gas Inlet | 1/8" compression fitting |
| Pressure Range | 0.34–2 barg (5–30 psig) with vent |
| Output | 0–1 V analog |
| Compliance | ATEX Ex II 2 G Ex ib IIC T4 Gb, Tamb 5°C to +45°C |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | AL-HB6200 |
| Pricing | Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-F |
| Weight | 2 kg |
| Sampling Method | Automatic Continuous Sampling |
| Operating Temperature | Ambient (15–30 °C) |
| Detection Range | ppb to ppm |
| Target Gases | Cl₂, HF, HCN, chlorobenzene, toluene, and other fumigants/volatile organic compounds (VOCs) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-X |
| Pricing | Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN 3.5 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | < 1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (integrated mass flow control) |
| Built-in Pumps | 2 (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD panel |
| Interface | USB and/or RS232 |
| Digital I/O | TTL and digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limits | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software Platform | WinMuster v5.x (supports PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| Data Integrity | Audit-trail enabled |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | <1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (internally regulated) |
| Sampling System | Dual built-in pumps (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD screen |
| Interface | USB and/or RS232 |
| Digital I/O | TTL & digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limit | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software | WinMuster v5.x (PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| OS Compatibility | Windows XP and later |
| Calibration Stability | Automated drift compensation over 12 months |
| Warranty | 1 year |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | meteo |
| Compliance | EN 13725 |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Sensor Array | 10 MOS (Metal Oxide Semiconductor) sensors |
| Data Acquisition | Continuous, 24/7 |
| Communication | Wi-Fi + optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer & wind vane |
| Software Algorithms | PCA, PLS regression, Mahalanobis & Euclidean distance analysis |
| Calibration Reference | EN 13725-compliant dynamic olfactometry |
| Brand | ALPHA (UK) |
|---|---|
| Origin | United Kingdom |
| Model | DS2000 |
| Sensor Technology | Aluminium Oxide Capacitive |
| Measurement Range | -110°C to +20°C dew point |
| Accuracy | ±2°C over full scale |
| Display | Dual-color 7-segment, 5-digit main + 1-digit auxiliary |
| Operating Temperature | -20°C to +50°C |
| Storage Temperature | -50°C to +70°C |
| Humidity Range | 10–90% RH (non-condensing) |
| Output Options | 4–20 mA / 0–10 V linear retransmission |
| Communication | RS-485 Modbus RTU |
| Compliance | Traceable calibration to NPL and ISO/IEC 17025 accredited standards |
| Gas Compatibility | Fully compatible with SF₆, compressed air, nitrogen, argon, hydrogen, and other inert/dry process gases |
| Units Supported | °C dp, °F dp, ppm(v), g/m³, lb/MMSCF |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas COS |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | 2 ppb |
| Precision (1σ) | 0.6 ppb + 0.5% of reading |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | <60 s |
| Measurement Range | 0–10 ppm |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Control | ±0.016 mbar |
| Sample Temperature Range | −10 to +45 °C |
| Sample Humidity Limit | <99% RH (non-condensing) |
| Sample Flow Rate | >400 mL/min |
| Data Outputs | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA / 0–10 V), USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas H₂ |
| Detection Principle | Optical-feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) |
| Operating Pressure | <100 mbar (absolute) |
| Detection Limits (3σ) | H₂O ≤ 0.01 ppm, CH₄ ≤ 0.001 ppm, O₂ ≤ 5 ppm, CO₂ ≤ 0.2 ppm, CO ≤ 0.001 ppm, H₂S ≤ 0.001 ppm, HCHO ≤ 0.001 ppm, HCOOH ≤ 0.005 ppm, NH₃ ≤ 0.001 ppm, HCl ≤ 0.001 ppm |
| Compliance | T/CECA-G0015-2017 (equivalent to ISO 14687-2:2019) |
| Calibration | Factory-pre-calibrated, integrated auto-zero and span verification |
| Carrier Gas | None required |
| Sample Volume Requirement | Minimal (<10 mL/min at sub-atmospheric pressure) |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas H₂S |
| Detection Principle | Optical-feedback Cavity-enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | 1 ppb |
| Accuracy (1σ) | 0.3 ppb |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | <5 s |
| Measurement Range | 0–5000 ppb |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Stability | ±0.016 mbar |
| Sample Temperature Range | −10 to +45 °C |
| Sample Humidity Limit | <99% RH, non-condensing |
| Sample Flow Rate | >400 mL/min |
| Output Interfaces | Ethernet, Modbus TCP/IP & RTU, 4–20 mA analog, USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Form Factor | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HCHO |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | <1 ppb |
| Accuracy (1σ) | 0.15 ppb + 0.1% of reading @ 300 s |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 Hz |
| Measurement Range | 0–10 ppm |
| Temperature Control Stability | ±0.002 K @ 1 s |
| Pressure Control Stability | ±0.016 mbar |
| Sample Flow Rate | >400 mL/min |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | <99% RH, non-condensing |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog Outputs, USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HCl |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| HCl Detection Limit (3σ, 300 s) | 1 ppb |
| HCl Accuracy (1σ, 300 s) | 0.3 ppb + 0.1% of reading |
| HCl Measurement Range | 0–1000 ppb |
| H₂O Measurement Range | 0–5% |
| H₂O Detection Limit (3σ, 300 s) | 180 ppm |
| Zero Drift (72 h) | ±0.20 ppb |
| Response Time (10–90%) | <300 s |
| Measurement Interval | 2 s |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Stability | ±0.016 mbar |
| Sample Temp. Range | −10 to +45 °C |
| Max. Sample Humidity | <99% RH (non-condensing) |
| Sample Flow Rate | >400 mL/min |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog Outputs, USB |
| Power | 110–230 VAC, 50–60 Hz, 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HF |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 300 s) | < 0.015 ppb |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | < 300 s |
| Measurement Range | 0–1000 ppb HF |
| Optional Co-measurements | O₂ (0–21%), H₂O (0–5%) |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Pressure Control | ±0.016 mbar |
| Sample Temp. | −10 to +45 °C |
| Sample Humidity | < 99% RH, non-condensing |
| Flow Rate | < 2000 mL/min |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA), USB |
| Power | 110–230 VAC, 50–60 Hz, 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas NH₃ |
| Detection Principle | Optical-feedback Cavity-enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 300 s) | < 0.05 ppb |
| Accuracy (1σ) | 0.015 ppb + 0.1% of reading @ 300 s |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 Hz |
| Measurement Range | 0–1000 ppb (guaranteed), 0–10 ppm (operational) |
| Cavity Volume | 25 mL |
| Temperature Control Stability | ±0.002 K @ 1 s |
| Pressure Control Stability | ±0.016 mbar |
| Sample Flow Rate | >400 mL/min |
| Operating Ambient Temperature | −10 to +45 °C |
| Relative Humidity | <99% RH (non-condensing) |
| Data Outputs | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA), USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC Series |
| Pricing | Available Upon Request |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Enclosure Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, and 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery Type | Rechargeable NiMH |
| Battery Life | Up to 60 hours |
| Calibration Traceability | NIST-traceable |
| Flow Measurement Principle | Venturi-based differential pressure |
| Environmental Rating | IP65-rated weather-resistant enclosure |
| Connectivity | Integrated Bluetooth 5.0 for iOS/Android mobile devices |
| Standard Conditions Configuration | User-definable STP (Standard Temperature and Pressure) settings |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery | Rechargeable NiMH |
| Runtime | Up to 60 hours |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate | 6 L/min (adjustable 3–10 L/min) |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable, 1 hr charge time, >30 hr runtime) |
| Data Logging Interval | 5 min |
| Dimensions | 10" × 12" × 7" |
| Data Export | USB flash drive |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-time particulate (RTP), PEET anemometer, optical scattering sensor |
| Compliance | Designed to meet U.S. EPA Reference Method (FRM) criteria for low-flow ambient particulate monitoring |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate Range | 3–10 L/min |
| Nominal Flow Rate | 6 L/min |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable) |
| Charge Time | 1 h |
| Runtime | >30 h |
| Data Logging Interval | 5 min |
| Dimensions (L×W×H) | 10" × 12" × 7" |
| Shipping Weight | 25 lb |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-Time Particle (RTP) Sensor, PEET Anemometer, Optical Scattering Dust Monitor |
| Data Export | USB Flash Drive |
| Compliance | Designed to meet EPA Reference Method (FRM) criteria for low-flow particulate sampling |