Other Gas Detection Instruments
Filter
Showing 31–60 of 102 results
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC Series |
| Pricing | Available Upon Request |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Enclosure Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, and 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery Type | Rechargeable NiMH |
| Battery Life | Up to 60 hours |
| Calibration Traceability | NIST-traceable |
| Flow Measurement Principle | Venturi-based differential pressure |
| Environmental Rating | IP65-rated weather-resistant enclosure |
| Connectivity | Integrated Bluetooth 5.0 for iOS/Android mobile devices |
| Standard Conditions Configuration | User-definable STP (Standard Temperature and Pressure) settings |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery | Rechargeable NiMH |
| Runtime | Up to 60 hours |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate | 6 L/min (adjustable 3–10 L/min) |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable, 1 hr charge time, >30 hr runtime) |
| Data Logging Interval | 5 min |
| Dimensions | 10" × 12" × 7" |
| Data Export | USB flash drive |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-time particulate (RTP), PEET anemometer, optical scattering sensor |
| Compliance | Designed to meet U.S. EPA Reference Method (FRM) criteria for low-flow ambient particulate monitoring |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate Range | 3–10 L/min |
| Nominal Flow Rate | 6 L/min |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable) |
| Charge Time | 1 h |
| Runtime | >30 h |
| Data Logging Interval | 5 min |
| Dimensions (L×W×H) | 10" × 12" × 7" |
| Shipping Weight | 25 lb |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-Time Particle (RTP) Sensor, PEET Anemometer, Optical Scattering Dust Monitor |
| Data Export | USB Flash Drive |
| Compliance | Designed to meet EPA Reference Method (FRM) criteria for low-flow particulate sampling |
| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive interface |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | LGD Series |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gases | NH₃, CH₄, H₂O, CO₂, HCl, HF, O₂ |
| Design | OEM-ready modular optical sensor |
| Operating Temperature Range (Heated Option) | Up to 190 °C |
| Measurement Type | Non-contact, in-situ, continuous |
| Cross-Interference | Negligible due to spectral selectivity |
| Calibration | Factory-calibrated |
| Compliance Context | Designed for integration into systems compliant with IEC 61508 (SIL2-capable architectures), EN 14181 (QAL3), and EPA Method 205/207 (for extractive TDLAS configurations) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Accuracy | ±1 ppm or ±2% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±2% FS/24 h |
| Response Time (T90) | ≤90 s |
| Sampling Method | Extractive |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d IIB T4 Gb |
| Power Supply | 220 V AC |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MGA-6000 |
| Sampling Method | Extractive |
| Power Supply | 220 V AC |
| Explosion Protection | Ex d IIB T4 |
| Ingress Protection | IP65 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Response Time (T90) | ≤60 s |
| Accuracy | ±1 ppm or ±1% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | Bios Defender 510 & 520 |
| Certification | ISO/IEC 17025 Accredited by NVLAP (NIST) |
| Operating Temperature Range | –20 °C to +50 °C |
| Display | Backlit LCD with Navigation Menu |
| Connectivity | RS-232 Serial Interface |
| Compliance | RoHS Directive 2011/65/EU |
| Flow Units | mL/min, L/min, cc/min, CFM |
| Data Logging | Up to 100+ readings with user-defined intervals (1–60 min) |
| Integrated Sensors | Built-in temperature sensor and pressure transducer (Defender 520 only) |
| Software | PC-based calibration data acquisition, curve plotting, report generation, and GLP-compliant audit trail export |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GC-2020 |
| Pricing | Upon Request |
| Detector Type | Photoionization Detector (PID), 10.6 eV |
| Measurement Range | 0–50 ppm (C₂H₄) |
| Column Configuration | Dual packed columns with backflush capability |
| Carrier Gas | Nitrogen (N₂), regulated flow control |
| Sample Introduction | Six-port multi-position valve with 1 mL sample loop |
| Cycle Time | 420 s typical |
| Data Storage | >2 GB internal flash memory |
| Display Interface | 7-inch capacitive touchscreen LCD (1024 × 600) |
| Rack Mount | 19-inch, 4 HU |
| Analog Output | 4–20 mA / 0–10 V (isolated) |
| Digital Interface | RS-232/RS-485 serial, parallel I/O for PLC integration |
| Auto-Diagnostics | Built-in system self-test with event logging |
| Standby Mode | Low-power operational state with wake-on-trigger capability |
| Compliance | Designed per IEC 61000-6-3 (EMC), EN 61010-1 (Safety), compatible with GLP/GMP data integrity requirements |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | AM4209 |
| Weight | <400 g |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| IP Rating | IP54 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Sensitivity | 1 g/year (static), 3 g/year (dynamic) |
| Response Time | <1 s (typical) |
| Recovery Time | <5 s (typical) |
| Battery | 3.7 V DC, 2550 mAh Li-ion |
| Charging Time | 6 h |
| Standby Time | 10 h (backlight off) |
| Auto-Shutdown | 10 min |
| Compliance | EN 14624 |
| Gas Compatibility | R32, R290, R410A, R134a, R454A, R454B, R1234yf, HFO-1234yf and other A2L refrigerants |
| Brand | Eranntex |
|---|---|
| Model | MS500-MEK |
| Detection Principle | Electrochemical (Standard), Optional IR/PID/Catalytic/Thermal Conductivity |
| Gas Measured | Methyl Ethyl Ketone (MEK, C₄H₈O) |
| Display | 2.5" HD Color TFT Screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight & Powerful Water Jet Resistant |
| Explosion Protection | Intrinsically Safe (Ex ib IIB T4 Gb) |
| Operating Temperature | −40 °C to +70 °C |
| Battery | Rechargeable 6000 mAh Polymer Li-ion |
| Runtime | Up to 20 h (typical, single-gas, pump off) |
| Data Storage | 100,000 entries (expandable) |
| Communication | USB, RS232, Bluetooth (optional) |
| Sampling Method | Built-in Pump with >10 m Sampling Distance |
| Filtration | Integrated Water Vapor & Particulate Filter |
| Calibration | Multi-point Target Gas Calibration |
| Compliance | CMC Certified (China Metrology Accreditation), GB/T 34004–2017, GB 12358–2006 |
| Alarm Modes | Visual (LED/Screen), Audible (≥85 dB), Vibration, Undervoltage & Fault Indication |
| Units | ppm, mg/m³, %LEL, %Vol (auto-converted via molecular weight input) |
| Humidity & Temp Measurement | Optional Integrated Sensor (±2% RH, ±0.5 °C) |
| Software Support | PC-based Data Analysis Suite with Audit Trail, Export (CSV/XLS), Print & Trend Graphing |
| Brand | Eranntex |
|---|---|
| Model | PTM600-HBr |
| Detection Principle | Electrochemical (standard), Optional IR/PID/TC/Catalytic Combustion |
| Detection Range | 0.001 ppm to 99.999 %Vol (auto-ranging, specified at order) |
| Resolution | 0.001 ppm (low-range), 0.001 %Vol (high-range) |
| Display | 3.5-inch HD color TFT screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight, powerful water jet resistant |
| Safety Certification | Intrinsically Safe (Ex ib IIB T4 Gb), CMC Certified |
| Sampling Method | Built-in explosion-proof diaphragm pump with integrated hydrophobic particulate filter |
| Sampling Distance | >10 m (with standard sampling hose) |
| Data Storage | Standard 100,000 records (expandable via SD card or USB mass storage) |
| Communication Interfaces | USB 2.0, RS232, Bluetooth 5.0 |
| Power Supply | 10,800 mAh Li-polymer battery (rechargeable via USB, supports hot-swap operation) |
| Operating Temperature | −40 °C to +70 °C (instrument) |
| Environmental Compensation | Integrated capacitive digital temperature/humidity sensor (optional) with real-time sensor compensation |
| Alarm Types | Dual-level (low/high), range, TWA, STEL |
| Calibration | Multi-point span calibration, zero auto-tracking, calibration log with timestamp and operator ID |
| Compliance | Meets GB/T 34004–2017, JJG 693–2011, ISO 16000-25, ASTM D6792, and supports 21 CFR Part 11 audit trail when used with compliant host software |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TiH203 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AQMS-200 |
| Pricing | Available Upon Request |
| Key | Detection Range: 0–250 ppm |
|---|---|
| LOD | 1 ppm |
| Accuracy | ±5 ppm (0–50 ppm), ±10% FS (50–250 ppm) |
| T90 Response Time | <15 s |
| Sensor Type | GSS Semiconductor Gas Sensor |
| Operating Temp | 0–50 °C |
| Operating Humidity | 30–80% RH (non-condensing) |
| Power | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Dimensions | 195 × 122 × 54 mm (with probe) |
| Weight | <460 g (with probe and battery) |
| Enclosure Rating | IP20 / NEMA 1 |
| Certifications | UL 2034, BS 7860, FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 200 |
| Price | Upon Request |
| Measurement Range (Low) | 0–1.0 ppm |
| Measurement Range (Medium) | 0–25.00 ppm |
| Measurement Range (Leak Detection) | 0–50.0 ppm |
| Accuracy | ±10% (0–0.10 ppm), <±0.5 ppm (0–10.0 ppm), <±2 ppm (10–50.0 ppm) |
| Resolution | 0.001 ppm / 0.01 ppm / 0.1 ppm (per range) |
| T90 Response Time | <60 s (all ranges) |
| Sensing Principle | Gas-Sensitive Semiconductor (GSS) |
| Operating Temperature | −20°C to +50°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 VDC, 800 mA |
| Rechargeable Battery Options | 9.4 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 & NEMA 1 |
| Dimensions (w/ probe) | 195 × 122 × 54 mm |
| Weight (w/ probe & battery) | <460 g |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Brand | CORTEST |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GASTEC Tube-Type Gas Detector |
| Pricing | Available Upon Request |
| Brand | Graywolf |
|---|---|
| Model | DSII-5 |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Pricing | Upon Request |
| Detection Parameters | TVOC, HCHO, NH₃, CO, CO₂, Temperature, Relative Humidity |
| Data Acquisition | Low-noise, high-resolution analog front-end |
| Operating System | Wolf OS |
| Connectivity | Modular probe interface (up to 20 simultaneous parameters) |
| Units | mg/m³, µg/m³, ppm, ppb, % vol |
| Annotation Capability | Text, voice, image logging on-device |
| Compliance Context | Designed for ASTM D6245, ISO 16000 series, ASHRAE 62.1, and OSHA PEL/TWA reference applications |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Measurement Range | 0–1000 ppm NH₃ |
| Accuracy | ±5 ppm (0–100 ppm), ±10% FS (100–1000 ppm) |
| T90 Response Time | <60 s |
| Sensing Principle | Metal Oxide Semiconductor (MOS) |
| Operating Temperature | −20°C to +60°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions (w/ probe) | 195 × 122 × 54 mm |
| Weight (w/ probe & battery) | <460 g |
| Compliance | FCC Part 15 |
| EN 50082-1 | 1997 |
| EN 50081-1 | 1992 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 200 |
| Price | Upon Request |
| Measurement Range | 0–10 ppm |
| LOD | 0.01 ppm |
| Accuracy | ±10% of reading |
| T90 Response Time | <60 s |
| Sensor Type | GSS Semiconductor Gas Sensor |
| Operating Temperature | −20 °C to +50 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Certifications | UL 2034, BS 7860, FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Power Supply | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions (w/ probe) | 195 × 122 × 54 mm |
| Weight (w/ probe & battery) | <460 g |
| Probe-to-Host Separation Distance | Up to 14 m |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GTI 660 |
| Pricing | Upon Request |
| Display | 3.2-inch high-resolution color LCD (Chinese UI) |
| Pressure Range | 0–500 Pa (±0.5% of reading ±1 Pa, 0.1 Pa resolution) |
| Airflow Range | 1–60 m³/h (±3% of reading ±0.5 m³/h, 0.01 m³/h resolution) |
| Atmospheric Pressure Range | 70–130 kPa (±2% of reading, 0.1 kPa resolution) |
| Temperature Range | 0–60 °C (±0.5 °C, 0.1 °C resolution) |
| Power Supply | AC 220 V for blower unit |
| Blower Unit Weight | ~10 kg |
| Control Host Weight | ~250 g (excl. batteries) |
| Dimensions (Blower) | 370 × 295 × 315 mm |
| Dimensions (Packaging) | 590 × 350 × 500 mm |
| Communication | RS485, Wi-Fi |
| Compliance | GB/T 7106–2019, JG/T 211–2007, GB/T 31433–2015 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-102S |
| Light Source | High-Brightness LED |
| Wavelength | 635 nm |
| Detection Limit | 0.005 mg/m³ |
| Measurement Range | 0.000–0.100 mg/m³ (40 L sampling volume) or 0.000–0.800 mg/m³ (5 L sampling volume) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C / 3000-C1 |
| Particle Size Range | 0.015–1.0 µm (3000-C1), 0.02–1.0 µm (3000-0C) |
| Concentration Range | 0–100,000 particles/cm³ |
| Sample Flow Rate | 100 cm³/min |
| Total Flow | 700 cm³/min |
| Fit Factor Calculation | Direct Cout/Cin ratio |
| Test Agent | ≥99.5% isopropanol or ethanol |
| Display | 7-inch full-color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG479, GB 2626–2019, GB 19083–2010, GB/T 32610–2016 |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Software | Windows 7/8/10 compatible |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Dimensions (W×H×D) | 208×117×262 mm (3000-0C), 208×152×263 mm (3000-C1) |
| Weight | 2.3 kg (3000-0C), 3.1 kg (3000-C1) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C / 3000-C1 |
| Particle Size Range | 0.02–1.0 µm (3000-0C), 0.015–1.0 µm (3000-C1) |
| Sample Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation | Direct Cout/Cin ratio |
| Test Agent | ≥99.5% isopropanol or ethanol |
| Display | 7-inch full-color TFT touch screen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE UK, GB 2626–2019, GB 19083–2010, GB/T 32610–2016 |
| Connectivity | USB, Ethernet, Wi-Fi |
| Software | Windows 7/8/10 compatible |
| Data Export | Microsoft Excel format |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Dimensions (W×H×D) | 208×117×262 mm (3000-0C), 208×152×263 mm (3000-C1) |
| Weight | 2.3 kg (3000-0C), 3.1 kg (3000-C1) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Language Options | English, French, Spanish, Portuguese, Chinese |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4–22 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Supported Languages | English, French, Spanish, Portuguese, Chinese |
| Max Simultaneous Units Controlled via PC | 4 |
| Data Export Format | Microsoft Excel |