| Brand | Alpha MOS |
|---|---|
| Origin | France |
| Model | ASTREE LS16/48 |
| Type | Taste Analysis System |
| Sensor Technology | ChemFET-based Potentiometric Array |
| Sample Throughput | 1 sample per 3 minutes (with auto-sampler) |
| Configuration Options | 16- or 48-channel sensor array |
| Compliance | Designed for GLP/GMP-aligned laboratories, supports audit-trail-capable data management per FDA 21 CFR Part 11 requirements |
| Brand | Atik |
|---|---|
| Sensor Resolution | 1620 × 1220 pixels |
| Sensor Type | Monochrome back-illuminated CCD |
| Pixel Size | 9.0 µm × 9.0 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | <10 e⁻ (at 0.1 MHz) |
| Dark Current | <0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TE) to −20 °C below ambient |
| Interface | USB 2.0 |
| Shutter | Electronic rolling shutter |
| Compliance | CE, RoHS, FCC Class B |
| Software Support | ASCOM, DirectShow, LabVIEW, MATLAB, Python (via SDK) |
| Brand | Atik Instruments |
|---|---|
| Sensor Resolution | 1460 × 1932 pixels |
| Sensor Type | Monochrome Back-Illuminated CCD |
| Pixel Size | 6.45 µm × 6.45 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | < 10 e⁻ (at slow readout) |
| Dark Current | < 0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TEC), regulated to ΔT ≤ −45 °C below ambient |
| Interface | USB 2.0 with proprietary low-noise controller |
| Shutter | Electronic Rolling Shutter (global reset capable) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Benteng |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BT-1181 |
| Pricing | Upon Request |
| pH Measurement Range | 0.00–14.00 |
| pH Accuracy | ±0.02 pH |
| Resolution | 0.01 pH |
| Repeatability | ≤1% |
| Stability | ±1% F.S. / 4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Compensation Range | 0.1–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Brand | BosinTech |
|---|---|
| Model | C-Nose |
| Origin | Shanghai, China |
| Manufacturer | Shanghai Bosin Industrial Development Co., Ltd. |
| Product Type | Sensory Intelligent Analysis System – Electronic Olfaction Analyzer |
| Detection Principle | Metal Oxide Semiconductor (MOS) Sensor Array-Based Volatile Organic Compound (VOC) Profiling |
| Sensor Count | 14 Independent MOS Sensors with Differential Selectivity |
| Detection Limit | Sub-ppb (parts-per-quadrillion equivalent sensitivity in optimized matrix) |
| Sample Analysis Time | 60–120 s |
| Sensor Response Time | <1 s |
| Architecture | Modular Air Chamber Isolation per Sensor |
| Configuration Options | Desktop, Portable, and Online Integration Versions |
| Data Analysis Framework | PCA, SIMCA, PLS-DA, DFA, PLS, and Hierarchical Clustering |
| Compliance Readiness | Supports GLP/GMP-aligned audit trails, 21 CFR Part 11-compliant software modules (optional), ISO 19957 (electronic nose performance validation), ASTM E2813 (odor discrimination testing protocols) |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Instrument Type | Discrete Analyzer (Flow-Based Spectrophotometric Analyzer) |
| Model | CleverChem F.U.V. |
| Wavelength Range | 200–850 nm |
| Sample Volume per Test | 10 mL |
| Reagent Positions | N/A (Reagent-free operation for core wine parameters) |
| Flow Cell Pathlength | 0.20 mm |
| Light Source | Deuterium + Tungsten-Halogen UV/Vis Lamp (2000 h lifetime) |
| FTIR Resolution | < 0.4 cm⁻¹ |
| UV-Vis Spectral Resolution | 0.25 nm |
| Detector | 2048-pixel CCD array (200 × 14 µm/pixel) |
| Temperature Control Range | 5–35 °C |
| Dimensions (Analyzer Unit) | 35 × 28 × 26 cm (W×D×H) |
| Weight | 10 kg |
| Compliance | Designed for GLP-compliant wine laboratories |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DF-H-05 |
| Price | USD 165 (FOB) |
| Target Analytes | Fe, Cd, Co, Cu, Mn, Zn, Pb, Ni, P, As, Cr, Mo, Sb, Se, V, W |
| Binding Layer | ZrO₂–Chelex composite gel, thickness 0.40 mm, dimensions 150 × 20 mm |
| Filter Membrane | PVDF, 0.10 mm thick, 150 × 20 mm |
| Diffusive Gel | Agarose-based, nominal thickness 0.80 mm |
| Sampling Area | 3000 mm² (150 × 20 mm) |
| Packaging | Individually sealed in sterile, light-blocking aluminum foil pouches under moist conditions |
| Shelf Life | 12 months at room temperature, protected from light and desiccation |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Model | 1000 Series Fire Detector Test Chamber |
| Compliance | EN 54-7, EN 54-5, EN 14604, BS 5446-2, GB 4715-2024, GB 4716-2024 |
| Configuration Options | 1100 (smoke-only), 1300 (heat-only), 1400 (combined smoke/heat), 1700 (heat-only with active cooling), 1800 (combined smoke/heat with active cooling) |
| Form Factor | Benchtop |
| Application Domain | Factory QC, R&D Lab, Certification Testing |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | BreathSpec® |
| Sample Introduction | 6-port valve direct injection |
| Sensitivity | sub-ppb (pptv–ppbv range) |
| Spectral Library | Volatile Organic Compounds (VOCs) |
| Ionization Source | ³H beta emitter (300 MBq, exempt per IEC 61017 & GB 18871-2002 Annex A) |
| Drift Voltage Polarity | Switchable positive/negative mode |
| Detection Principle | Coupled Gas Chromatography–Ion Mobility Spectrometry (GC-IMS) |
| Data Acquisition | High-speed ADIO board with X-scale real-time processing |
| Display | 6.4″ TFT VGA screen |
| Connectivity | RS232 / USB-A ×2 / Ethernet (RJ45) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Dimensions | 449 × 375 × 177 mm (W × D × H) |
| Weight | 15.5 kg |
| Enclosure | 19″ rack-mountable chassis, IP20 rated, EMC compliant |
| Cooling | Thermally regulated axial fan (max. 5.5 m³/h) |
| Gas Fittings | 3 mm stainless steel Swagelok® for drift gas, sample inlet/outlet, carrier gas, and IMS exhaust |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | FlavourSpec® 25 |
| Sample Introduction | Headspace Auto-sampling |
| Sensitivity | Sub-ppb (without preconcentration) |
| Spectral Output Formats | 2D ion mobility chromatograms, 3D retention time–drift time–intensity plots, and compound-specific fingerprint spectra |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Redox Colorimetric Titration |
| Wavelengths | 650 nm (test), 810 nm (reference) |
| Range | 0–1,000 ppm (customizable) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Analysis Cycle Time | 10 min |
| Sensitivity | 1% FS |
| Ambient Temperature | 20–60 °C (−4–140 °F) |
| Dimensions | 1016 mm H × 406 mm W × 241 mm D |
| Weight | 45.3 kg |
| Sample Interface | 1/4″ compression fitting |
| Sample Flow Rate | 200 mL/min |
| Max Sample Pressure | <5 psi |
| Max Suspended Solids | <1,000 µm |
| Power Supply | 24 VDC or 90–240 VAC |
| Analog Outputs | up to eight isolated 4–20 mA (self-powered) |
| Digital Inputs | 8 dry/wet contacts (24 VDC) |
| Ethernet | Embedded GUI via Modbus TCP/IP |
| Serial Protocols | Modbus RTU over RS-232/RS-485 |
| Alarm Outputs | User-configurable relay outputs |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Corrosion Resistance | H₂S- and Cl₂-resistant housing |
| Flow Path Architecture | Modular, scalable to 6 independent sample streams |
| Control Architecture | Physically segregated electronics and wet chemistry modules |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 |
| Product Type | Continuous Flow Analyzer (CFA) |
| Air Segmentation Technology | Yes |
| Online Pretreatment Modules | Heating, Digestion, Distillation, Dialysis, Extraction, Deaeration |
| Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm – 200 mm |
| Reaction Coil Material | Fused silica (2 mm ID) |
| Sample Introduction | Optional autosampler with automatic needle cleaning, programmable wash solution replacement, carbon fiber or borosilicate glass sampling probes |
| Compliance Standards | GB, HJ, EPA Methods (e.g., EPA 375.4, 450.1, 420.1), ISO 6878, ISO 11908, ISO 15681 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGCF-200 |
| Price Range | USD 70,000 – 100,000 (FOB China) |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Detection Principle | Segmented Flow Spectrophotometry with Air Segmentation |
| Optical Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil Material | Fused silica (2 mm inner diameter) |
| Integrated Sample Pretreatment | On-line digestion, distillation (steam distillation/blow-out), dialysis, extraction, heating, mixing, dilution, degassing, and auto-cleaning |
| Compliance Standards | ASTM D3869, ISO 14402, ISO 14403, ISO 23913, ISO 15681-2, HJ 665–667, HJ 670, CJJ/T 141, SL/T 788, NY/T 1121.7, NY/T 1228 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGFI-10 |
| Product Category | Flow Injection Analyzer |
| Brand | Harrick |
|---|---|
| Origin | USA |
| Model | HPL-C-13 |
| Construction Material | 316 Stainless Steel |
| Maximum Operating Pressure | 34.5 MPa (5000 psi) |
| Temperature Range | Up to 240 °C (with Kalrez O-rings) or 200 °C (with Viton O-rings) |
| Optical Path Length Range | 6 µm – 5 mm (via interchangeable PTFE spacers) |
| Window Aperture | 8 mm clear diameter |
| Port Configuration | Two 1/16″ Swagelok™ fittings |
| Thermal Management | Integrated cartridge heater, K-type thermocouple, and coolant channels |
| Mounting | FTIR-compatible slide-in sample stage |
| Compliance | Designed for ASTM E1421-compliant IR transmission measurements under process-relevant conditions |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ICP |
| Price | USD 195 (FOB Beijing) |
| Operating Temperature | Up to 10,000 K |
| Material | High-Purity Quartz (≥99.99% SiO₂) |
| Inner Diameter | 2.0 mm |
| Middle Tube ID | 12.0 mm |
| Outer Tube ID | 22.0 mm |
| Wall Thickness | 1.0–1.2 mm |
| Thermal Shock Resistance | ≥5 thermal cycles from 25 °C to 800 °C without cracking |
| Brand | Insent (Japan) |
|---|---|
| Origin | Japan |
| Type | Taste Sensing System (Electronic Tongue) |
| Sensor Principle | Artificial Lipid Membrane-Based Potentiometric Array |
| Compliance | Designed for GLP/GMP-aligned sensory evaluation workflows |
| Software | TS-5000Z Analysis Suite with FDA 21 CFR Part 11–ready audit trail option |
| Data Output | Multidimensional taste profiles (basic tastes + aftertaste richness), PCA/DA visualization, cluster heatmaps, temporal response curves |
| Sample Throughput | Up to 96 samples per automated sequence (with optional autosampler) |
| Interface | Touchscreen-guided operation with macro scripting support |
| Environmental Stability | EMI-shielded sensor chamber with temperature-controlled sample compartment (±0.1 °C) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A1 / 2DMax1100P1 |
| Flow Rate Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 0–4000 psi with overpressure protection |
| UV-Vis Detection Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P1 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A2 / 2DMax1100P2 |
| Flow Range | 0–200 mL/min (customizable up to higher rates) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-VIS Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P2 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A3 / 2DMax1100P3 |
| Price | Upon Request |
| Pump Flow Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-Vis Detector Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P3 only) | 160-tube rack, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A1 / 2DMax1500P1 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Sealing Force | Up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.3 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi (A1) / 0–4,000 psi (P1) |
| UV-VIS Detection | Four simultaneous wavelengths, 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200-line grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitation Loop | 20 µL (A1) / 2 mL (P1) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A2 / 2DMax1500P2 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Seal Force | up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.5 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi |
| UV-VIS Detection Wavelength Range | 190–900 nm (quad-wavelength simultaneous detection) |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200 lines/mm grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitative Loop | 20 µL (customizable) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition Range | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Gas Supply | Nitrogen or compressed air |
| Brand | LeiCi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PXBJ-286F |
| Price | USD 650 (FOB) |
| Sample Introduction Modes | Direct Sampling, Dynamic Headspace Sampling, Field Sampling |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model Series | PXSJ-227L, PXSJ-226T, PXSJ-216F, PXSJ-270F |
| Sample Introduction | Direct immersion |
| Category | Ion Meters (Potentiometric Ion-Selective Electrode Analyzers) |
| Brand | Masa |
|---|---|
| Origin | Slovakia |
| Model | MCCGC-AIMS |
| Sample Introduction | Automated |
| Sensitivity | ppb to ppt |
| Library | VOCs, Explosives |
| Operating Pressure | 600–1200 mbar |
| Drift Gas Flow | 500–1200 mL/min |
| Sample Gas Flow | 2–500 mL/min |
| Drift Field Strength | 200–560 V/cm |
| Polarity | Positive/Negative |
| Ionization Source | Corona Discharge (Non-radioactive) |
| Pre-separation GC | Multi-Capillary Column Gas Chromatograph |
| IMS Temperature Range | 30–140 °C |
| Resolution (FWHM) | 90–100 (N₂/air) |
| Power Supply | 250 V / 24 V |
| Communication | TCP/IP, USB 2.0 |
| Dimensions (mm) | 490 × 390 × 150 |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 916 Ti-Touch |
| Electrode Interfaces | 2 working electrode ports |
| Dosing Channels | 2 independent dosing units |
| Connectivity | Built-in Ethernet & LIMS interface (no PC required) |
| Report Output | Auto-generated PDF reports saved to USB drive |
| Sample Handling | Optional automated sample processor with interchangeable rotor trays (e.g., 12-, 24-, or 48-position) |
| Stirring Control | Adaptive speed adjustment based on sample viscosity |
| Dosing Technology | Dosino TMDosino™ multi-dose module — reagent cartridge replacement without disassembly or operator contact |
| Regulatory Compliance | Full GLP/GMP traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowIR™ |
| Product Type | Continuous Flow Analyzer |
| Spectral Range | 4000–650 cm⁻¹ |
| Detector | DTGS |
| Pressure Range | Ambient to 7 bar (standard), up to 30 bar (high-pressure option) |
| Temperature Range | Ambient to 120 °C |
| Internal Cell Volume | 10 µL or 50 µL |
| Integrated Temperature Sensor | Yes |
| Dimensions (W×D×H) | 137 × 241 × 116 mm |
| Weight | 2.6 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DS Micro Flow Cell |
| Pricing | Upon Request |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |