Other General Analytical Instruments
Filter
Showing 61–90 of 382 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ATDS-20A |
| Price | USD 21,800 (FOB Beijing) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AwTDS-20A |
| Temperature Control Range (Desorption 1) | Ambient to 450 °C (1 °C increments) |
| Valve & Transfer Line Temp Range | Ambient to 300 °C (1 °C increments) |
| Cryogenic Trap Temp Range | −35 °C to Ambient (1 °C increments, electronic cooling) |
| Temperature Accuracy | < ±0.5 °C |
| Desorption Recovery | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Sample Capacity | 20 positions |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Re-injection & Backflush Flow | 0–100 mL/min (adjustable) |
| Simulated Sampling Flow | 0–160 mL/min (adjustable) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Heating Rate (2nd Stage) | >3000 °C/min |
| Dimensions | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | Domestic (China) |
| Model | CA-E2000 |
| Price | Upon Request |
| Heating Method | Far-infrared Ceramic Heater |
| Distillation Positions | 6 independent channels |
| Cooling System | Integrated Compressor-based Closed-loop Recirculating Chiller (Condensate Temp. <15 °C) |
| Nitrogen Flow Control | 0–2 L/min per channel (adjustable) |
| Timing Range | 1–999 min per channel (individual programmable) |
| Anti-suckback Valve | Integrated electromagnetic anti-backflow valve |
| Stirring | Built-in magnetic stirrer per receiving flask (speed adjustable) |
| Titration Fixture | Dedicated titration clamp integrated on mainframe |
| Power Consumption | ≤5000 W total (per-channel power adjustable) |
| Distillate Rate | 2–12 mL/min (channel-specific) |
| Heating Ramp Time | 5–8 min to setpoint |
| Flask Capacity | Six 1000 mL round-bottom flasks (customizable) |
| Dimensions (Main Unit) | 1100 × 470 × 800 mm |
| Dimensions (Compressor Unit) | 710 × 480 × 880 mm |
| Voltage | AC 220 V / 50 Hz |
| Brand | Beifen Sanpu |
|---|---|
| Model | CA-M |
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instrument Co., Ltd. |
| Heating Block Material | High-Purity Graphite |
| Temperature Range | Ambient to 350 °C (CA-M24/40/60) |
| Temperature Uniformity | ±0.1 °C |
| Heating Capacity | 24–60 sample positions (standard) |
| Block Hole Diameter | 32 mm (standard), 42 mm (glass-tube variants) |
| Hole Depth | 45–90 mm |
| Control System | PID-controlled microprocessor with digital timer and real-time overtemperature monitoring |
| Power Supply | AC 220 V / 50 Hz |
| Safety Protections | Overtemperature, overcurrent, and overvoltage cutoffs |
| Construction | Stainless steel chassis with corrosion-resistant internal components |
| Compatible Vessels | PTFE digestion tubes, borosilicate glass tubes, borosilicate quartz tubes (optional) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | CA-ST25 |
| Pricing | Upon Request |
| Sample Capacity per Batch | 2–6 units |
| Extraction Flask Volume | 250 mL or 500 mL (selectable) |
| Sample Mass per Vessel | 0–5 g |
| Temperature Control Range | Ambient +5 °C to 100 °C |
| Power Supply | 220 V ±10 V, 50 Hz |
| Heating Power | 1000 W |
| Net Weight | 20 kg |
| Optional Cooling Power | 1000 W |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CA-X16 |
| Pricing | Upon Request |
| Power Supply | 220 V AC, 50 Hz, 10 A |
| Microwave Output Power | 0–2000 W |
| Cavity Volume | 45 L |
| Cavity Material | 316L Stainless Steel with 6-Layer PTFE Coating |
| Microwave Frequency | 2450 MHz, Non-Pulsed Continuous Automatic Frequency Modulation |
| Temperature Range | Ambient to 350 °C, Accuracy: ±0.1 °C |
| Pressure Range | 0–15 MPa, Control Precision: ±0.01 MPa |
| Max. Internal Vessel Temp. | ≥310 °C |
| Max. Internal Vessel Pressure | ≥10.34 MPa (1500 psi) |
| Max. Outer Sleeve Rating | ≥450 °C / ≥20.68 MPa (3000 psi) |
| Sample Capacity | Up to 16 vessels (100 mL each), Max. Sample Volume per Vessel: 55 mL |
| Rotation | 360° Continuous Bidirectional Rotation |
| Safety Features | Dual Pressure–Temperature Control, Auto-Microwave Cutoff at Overpressure/Overtemperature, Rupture Disc with Secondary Pressure Relief, Self-Locking Buffer Anti-Explosion Door, Microwave Leakage <5 mW/cm² (Compliant with GB 10436 & IEC 61000-3-2) |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CA-Z100 |
| Heating Method | Far-infrared Ceramic Heater (Domestic) |
| Number of Heating Units | 6 |
| Adjustable Power per Unit | 1–800 W |
| Total Rated Power | 4800 W (adjustable) |
| Distillation Rate | 8–12 mL/min |
| Endpoint Control | Time-based, 0–999 min adjustable, ±2 mL accuracy |
| Cooling | External Compressor Chiller or Tap Water, Condenser Temperature <30 °C |
| Display | 7-inch Resistive Touchscreen |
| Sample Capacity | 1–6 independent channels |
| Heating Uniformity | Uniform Far-infrared Radiation |
| Anti-Backsuction | Integrated Silicone Stopper & PE Tube Assembly |
| Distillation Vessel | 500 mL Round-Bottom Flask (6 pcs) |
| Condenser | Coiled Reflux Condenser (6 pcs) |
| Receiving Vessels | Compatible with Volumetric Flasks (250 mL), Erlenmeyer Flasks, Graduated Cylinders, Beakers |
| Power Supply | Dual-input 220 V / 50 Hz |
| Dimensions (L×W×H) | 1000 × 520 × 800 mm |
| Compliance | Verified Recovery Rate ≥95% in CAL/ISO/IEC 17025 Accredited Laboratories for Phenols, Ammonia Nitrogen, Cyanide, Kjeldahl Nitrogen, and Oil Moisture Determination] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CA-Z300 |
| Pricing | Upon Request |
| Heating Units | 6 independent channels |
| Heating Method | Far-infrared ceramic heating (bowl-shaped, flameless, waterproof) |
| Power per Channel | 0–800 W (adjustable) |
| Temperature Control | Precise PID-controlled constant-temperature heating |
| Distillation Endpoint Detection | High-accuracy pressure-based load cell sensor (1–500 mL weight threshold, ±1 g repeatability) |
| Cooling System | Closed-loop internal recirculation with dual-stage cooling (air-cooled condenser + built-in compressor |
| temp range | 5–30 °C) |
| Anti-Suckback Protection | Vacuum-sensing solenoid valve with real-time pressure feedback |
| Condenser Cleaning | One-touch automated rinse function for all six condensers |
| Water Reservoir | Auto-fill with overflow cutoff |
| Display | 7-inch capacitive color touchscreen |
| Distillation Rate | 2–12 mL/min |
| Ramp Time | 5–8 min to set temperature |
| Timer Range | 1–999 min |
| Max Total Power | 5500 W (dynamically adjustable) |
| Flask Compatibility | Six 500 mL or 250 mL round-bottom flasks (custom configurations available) |
| Receiver Flexibility | Universal holder accepts volumetric flasks, Erlenmeyer flasks, graduated cylinders, beakers, etc. |
| Dimensions (L×W×H) | 1000 × 520 × 800 mm |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CA-Z300S |
| Pricing | Upon Request |
| Heating Units | 6 independent stations |
| Heating Method | Far-infrared ceramic heating (bowl-shaped, flameless, waterproof) |
| Power per Unit | 0–800 W (individually adjustable) |
| Temperature Range | Ambient to 420 °C (PID-controlled, per station) |
| Distillation Endpoint Control | Pressure-based load cell with weight feedback (1–500 g/ml, ±1 g accuracy) |
| Cooling System | Closed-loop internal recirculation with air-cooled condenser + built-in compressor (refrigeration capacity ≤2000 W |
| Anti-Suckback Protection | Vacuum-sensing solenoid valve |
| Condenser Cleaning | One-touch reverse-air purge |
| Display | 7-inch capacitive color touchscreen |
| Distillation Speed | 2–12 mL/min |
| Runtime Setting | 1–999 min |
| Max. Power Consumption | 5800 W (adjustable) |
| Dimensions (L×W×H) | 1000 × 520 × 800 mm |
| Flask Compatibility | Six 500 mL or 250 mL round-bottom flasks (custom configurations supported) |
| Receiving Vessels | Unrestricted — volumetric flasks, Erlenmeyer flasks, graduated cylinders, beakers, etc. |
| Water Reservoir | Auto-fill with overflow cutoff] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | CAHS-20A Plus |
| Sample Capacity | 20 positions |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Compatibility | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Beifen Sanpu |
|---|---|
| Model | DAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Sample Positions | 20 |
| Simultaneously Heated Samples | 1 or 2 |
| RSD | < 1.0% (100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (continuously adjustable) |
| Interface | USB |
| Control Mode | PC-based or front-panel |
| Inert Flow Path | Deactivated fused-silica tubing and valve components |
| Valve Configuration | High-inertness 6-port rotary valve with integrated heated transfer line |
| Sampling Method | Positive-pressure headspace injection |
| EPC Option | Available (electronic pressure control) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | EAHS-20A Plus |
| Price | USD 7,800 (FOB Beijing) |
| Sample Capacity | 20 positions |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Size Compatibility | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB communication with PC control + local panel operation |
| Valve Type | High-inertness 6-port valve with heated connection point |
| Sample Transfer Line | Deactivated fused-silica tubing |
| Drive Mechanism | Stepper motor actuation (no external gas required) |
| GC Synchronization | TTL/relay trigger for GC start and data system launch |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FAHS-20A Plus |
| Sample Capacity | 20-position |
| Vial Size Compatibility | 10 mL & 20 mL (customizable up to 100 mL) |
| Sample Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Heating | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (0.5/2/5 mL optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| Interface | USB |
| Inert Flow Path | Deactivated fused-silica and PEEK tubing throughout |
| Valve Configuration | High-precision 6-port valve with minimized dead volume |
| Power Supply | AC 220 V ±10%, 50/60 Hz] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | FTDS-III |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (up to 300 °C optional) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB |
| Display | 7-inch TFT LCD with Chinese UI (English firmware available upon request) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | HPTDS-III |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | HTDS-III |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | JAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Pressure Control | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–1800 s |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–1800 s |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB 2.0 |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 ready (with optional audit trail software module) |
| Brand | Beifen Sanpu |
|---|---|
| Model | KAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C on request), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-electronic pressure control (optional) |
| Rinse Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication with PC |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | MAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow (Purge/Backflush) | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication with PC |
| Valve Configuration | High-inertness 6-port valve with heated connection points |
| Tubing Material | Deactivated fused-silica or SilcoNert®-treated stainless steel |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Beifen Sanpu |
|---|---|
| Model | NAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC-electronic pressure control (optional) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | Compatible with ASTM D6866, ISO 11843-2, USP <467>, and FDA 21 CFR Part 11–compliant data handling when integrated with validated GC software |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | RAHS-20A Plus |
| Pricing | Upon Request |
| Sample Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Oven Temperature Range | 40–220 °C (configurable up to 300 °C), accuracy ±1 °C, stability <±0.5 °C |
| Valve & Transfer Line Temp Range | 40–220 °C (configurable up to 300 °C), accuracy ±1 °C |
| Pressure Control | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC optional |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB |
| Inert Flow Path | Deactivated fused-silica tubing throughout |
| Valve Configuration | Six-port rotary valve with low-dead-volume design |
| Operation Mode | Positive-pressure sampling |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SAHS-20A Plus |
| Sample Capacity | 20-position carousel |
| Sample Vial Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Sample Heating Range | 40–220 °C (optional extension to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (optional to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| RSD | < 1.0% (measured with 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Control Options | Local panel + PC software |
| Valve Configuration | High-inertness 6-port switching valve with heated connections |
| Sample Introduction Mode | Positive-pressure headspace sampling |
| Actuation | Motor-driven (no external gas required) |
| EPC Support | Optional electronic pressure control module |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Model | ZAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Oven Temperature Range | 40–220 °C (optional up to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Temp Range | 40–220 °C (optional up to 300 °C), ±0.5 °C stability |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (0.5/2/5 mL optional) |
| Carryover | <0.05% (tested with 100 ppm ethanol in water) |
| RSD | <1.0% (n=6, 100 ppm ethanol in water) |
| Inert Flow Path | Deactivated fused-silica and PTFE-lined tubing |
| Valve Type | High-precision 6-port 2-position valve with heated interface |
| Control Interface | USB 2.0, local 7-inch TFT LCD with Chinese UI |
| Automation Mode | Full sequence execution (equilibration, pressurization, sampling, injection, purge, vial indexing) |
| GC Synchronization | TTL/relay trigger output + software-controlled start |
| EPC Option | Electronic Pressure Control module available (optional) |
| Brand | Benteng |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BT-1181 |
| Pricing | Upon Request |
| pH Measurement Range | 0.00–14.00 |
| pH Accuracy | ±0.02 pH |
| Resolution | 0.01 pH |
| Repeatability | ≤1% |
| Stability | ±1% F.S. / 4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Compensation Range | 0.1–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BF-9860 |
| Pricing | Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | CH-II |
| Capacity | 1000 mL |
| Production Rate | 50 mL/h |
| Temperature Control | PID digital display |
| Temperature Accuracy | ±1 °C |
| Construction Materials | FEP, PTFE, silicone rubber |
| Voltage | 220 V / 50 Hz |
| Power | 350 W |
| Compliance | Designed for ISO/IEC 17025-compliant trace metal laboratories |
| Sample Compatibility | HNO₃, HCl, HF, alkaline solutions, and select organic solvents |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | NJ-PFA-60ml |
| Pricing | Upon Request |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lyotherm3 |
| Pricing | Available Upon Request |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Micropress |
| Pricing | Available Upon Request |
