Other Industry Specialized Instruments
Filter
Showing 121–150 of 276 results
| Brand | LUSTER |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CartonHERO-650B |
| Pricing | Available Upon Request |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CEL-QPCE3000 |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm (optional 200–2500 nm) |
| Wavelength Step Resolution | ≥1 nm, continuously adjustable |
| QE/IPCE Repeatability (RSI) | <0.3% (photocurrent) |
| Chopping Frequency | 5–1000 Hz |
| Monochromator | 300 mm focal length, asymmetric Czerny-Turner design, aberration-corrected, nitrogen-purged port |
| Light Source | 500 W Xe lamp (Osram), intensity stability <0.01% |
| Detector | UV-enhanced Si photodiode (300–1100 nm) |
| Electrochemical Integration | Compatible with Ivium and other CE-compliant potentiostats |
| Sample Stage | Motorized dual-position stage (reference + sample), EMI-shielded enclosure |
| Optional Bias Light | Single- or dual-channel LED/laser bias sources |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LM-8 |
| Pricing | Available Upon Request |
| Sample Size | 100 × 100 mm |
| Test Stations | 2–8 simultaneous samples |
| Turntable Center-to-Sample Center Distance | 195 mm |
| Rated Turntable Speed | 300 ± 10% rpm |
| Eccentricity | e = 22.5 mm |
| Fixture Internal Diameter | Ø83 mm |
| Fixture Internal Height | 25.5 mm |
| Effective Abraded Area per Sample | ≈54 mm² |
| Motor Power | 1.5 kW |
| Power Supply | 380 V ± 10%, 50 Hz ± 10%, 3-phase 4-wire |
| Brand | Chauvin Arnoux |
|---|---|
| Origin | France |
| Model | CA5001 / CA5003 / CA5005 |
| Safety Rating | 600 V CAT III, IEC/EN 61010-1 Ed.2, Pollution Degree 2 |
| Display | Analog moving-coil meter with anti-parallax mirror |
| DC Voltage Accuracy | ±1.5% of full scale |
| AC Voltage & Current Accuracy | ±2.5% of full scale |
| Resistance Accuracy | ±10% of full scale |
| Input Impedance | 20 kΩ/V |
| DC Current Ranges | CA5001: 50 µA–5 A |
| CA5003 | 50 µA–15 A |
| CA5005 | 50 µA–10 A |
| AC Current Ranges | CA5001: 5 mA–5 A |
| CA5003 | 1.5 mA–15 A |
| CA5005 | 3 A–300 A (with MN 89 mini clamp) |
| Resistance Ranges | 10 kΩ, 1 MΩ |
| Continuity Test | Audible beep at R < 50 Ω |
| AC Voltage dB Scale | 0 to +22 dB |
| Operating Temperature | −10 °C to +55 °C |
| Relative Humidity | < 90% RH (non-condensing) |
| Enclosure Protection | CA5001: IP40 |
| CA5003/CA5005 | IP53 |
| Dimensions | 160 × 105 × 56 mm |
| Weight | ~500 g |
| Power Supply | 1.5 V AA battery + 9 V PP3 battery |
| Battery Life | ~10,000 measurements (15 s/measurement for CA5001 |
| Fuse Protection | HRC fuses with “Fus” status indicator |
| Voltage Presence Detection | “Voltest™” LED (CA5003/CA5005 only) |
| Ohmmeter Auto-Zero | CA5003/CA5005 only |
| Stand | Multistand™ folding support with probe storage |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CM825-MDD |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | VC20plus |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Visioface1000D |
| Pricing | Upon Request |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | H1 |
| Pricing | Available Upon Request |
| Brand | CNIEL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | CNIEL PEC-System |
| Price | USD 57,800 (FOB Beijing) |
| Measurement Mode | DC |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Compliance | EN 50291-1, EN 54 |
| Application Scope | Functional verification and periodic calibration of CO alarms in manufacturing and QA environments |
| Brand | Aerospace Zongheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CRTA-2 |
| Price Range | USD 1,400 – 2,800 |
| Airflow Configuration | Axial Fan with Conical Inlet Duct |
| Wind Speed Control | 3.0 ± 0.3 m/s |
| Operating Voltage | 200–240 V, 50 Hz |
| Environmental Test Conditions | 23 ± 2 °C, 50 ± 5 % RH |
| Compliant Standards | GB 9779–2015, JG/T 24–2000 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T90 < 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm | (0–10) % vol (optional) |
| Calorific Value | displayed in kcal/m³ and MJ/m³ |
| Resolution | 0.01 % vol |
| Linearity Error | ±1 % FS (NDIR gases), ±2 % FS (O₂, H₂) |
| Repeatability | ≤1 % |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Display | LCD |
| Communication | RS-232 |
| Data Storage | Internal logging with query/delete functions |
| Self-Diagnostic Capability | Real-time sensor status monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3200Plus |
| Measurement Principle | CH₄/CO₂ via NDIR |
| Range | CH₄ (0–100)% vol |
| Accuracy | CH₄/CO₂ ±2% FS |
| Power | Rechargeable 18650 Li-ion battery |
| Interface | USB, Bluetooth 4.0 |
| Display | Color LCD |
| Data Storage | Internal logging with query/delete function |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm (hydrocarbons) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1 % FS |
| H₂/O₂ | ±2 % FS |
| Explosion Protection | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Auto-calibration | Built-in zero-air pump with automatic air zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV Absorption Spectroscopy |
| Measuring Range | 0–25,000 ppm (customizable) |
| Resolution | 1 ppm |
| Accuracy | ±2% FS |
| Repeatability | <2% |
| Response Time (T90) | <30 s |
| Optimal Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Operating Temperature | 5–35 °C |
| Electrical Interface | RS-485 / RS-232 / 4–20 mA |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Display | LCD |
| Zero Calibration | Integrated air-driven auto-zero pump |
| Sample Requirements | Dust-free, moisture-free, oil-free gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| C₂H₂/C₂H₄/CnHm (optional) | (0–10)% |
| Resolution | 0.01% |
| Response Time (T90) | <15 s (NDIR) |
| Principle | NDIR + MEMS-based Thermal Conductivity Detection (TCD) + Long-life Electrochemical O₂ Sensor (or Paramagnetic Option) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measured Gases | CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CnHm*/Calorific Value |
| Resolution | 0.01% |
| Minimum Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| CnHm | (0–10)% (optional) |
| Response Time | T90 < 15 s (NDIR) |
| Detection Principles | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Linearity Error | ±1% FS (NDIR gases), ±2% FS (O₂/H₂) |
| Repeatability | ≤1% |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions (L×W×H) | 412×152×294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Display | LCD |
| Communication | RS-232 |
| Calorific Value Units | kcal/m³ & MJ/m³ (switchable) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T₉₀ < 15 s (NDIR) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| C₂H₂/C₂H₄/CnHm | (0–10)% (optional) |
| Resolution | 0.01% |
| Repeatability | ≤1% FS |
| Linearity Error | ±1% FS (NDIR gases) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery |
| Communication | RS-232 |
| Thermal Value Units | kcal/m³ and MJ/m³ (switchable) |
| Self-Diagnostic Function | Yes |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3110P |
| Product Category | Natural Gas Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Response Time | T90 < 10 s (NDIR) |
| Resolution | 0.01% |
| Measurement Range | CH₄, CO₂ (0–100% vol) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3200 |
| Measurement Range | CH₄: (0–100)%, CO₂: (0–50)%, H₂S: (0–9999) ppm, O₂: (0–25)% |
| Resolution | CH₄/CO₂/O₂: 0.01% |
| H₂S | 1 ppm |
| Response Time | T₉₀ < 10 s (NDIR) |
| Principle | Non-Dispersive Infrared (NDIR) + Long-Life Electrochemical Detection (ECD) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9021EX |
| Measurement Range | CO/CO₂/CH₄/H₂/O₂/CₙHₘ/Calorific Value |
| Resolution | CO/CO₂/CH₄/CₙHₘ: ±1% FS |
| H₂/O₂ | ±2% FS |
| Minimum Full Scale | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| CₙHₘ | (0–10)% (optional) |
| Principle | NDIR + Electrochemical + Thermal Conductivity |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm (hydrocarbons other than CH₄) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1 % FS |
| H₂/O₂ | ±2 % FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232, RS-485, (4–20) mA, Ethernet |
| Display | LCD |
| Auto-calibration | Integrated zero-air pump with automatic air-based zeroing |
| Diagnostic Capability | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| CnHm (non-methane hydrocarbons) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/CnHm: ±1% FS |
| H₂/O₂ | ±2% FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Auto-calibration | Integrated zero-air pump with automatic air zeroing |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECOFOG |
| Pricing | Upon Request |
| Brand | EKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MP-11 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Automation Level | Semi-Automatic |
| Effective Test Points per I-V Curve | 400 |
| Voltage Measurement Accuracy | ±1% FS |
| Current Measurement Accuracy | ±1% FS |
| Max Voltage Range | 10–1000 V |
| Max Current Range | 0.1–30 A |
| Power Range | 10 W–18 kW |
| Scan Time | 4–60 ms |
| Internal Storage Capacity | 300 I-V curves |
| Display | 128×64 LED monochrome LCD (no backlight) |
| Host Dimensions | 230 × 320 × 180 mm |
| Host Weight | 2.5 kg |
| Sensor Unit Dimensions | 210 × 85 × 55 mm |
| Sensor Unit Weight | 0.5 kg |
| Battery | 8× Ni-MH rechargeable cells (host), 1× 006P (sensor) |
| Compliance | IEC 61215, IEC 61646, IEC 62446-1, ASTM E1036, UL 1703 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 130 |
| Pricing | Upon Request |
| Brand | Alpha Moisture Systems |
|---|---|
| Origin | United Kingdom |
| Model | CMH-P2 / CMH-RPC |
| Sensor Type | Chilled-mirror dew point sensor (primary standard method) |
| Measurement Range | −70 °C to +75 °C (−94 °F to +167 °F) with high-efficiency cooling |
| Accuracy | ±0.2 °C dew point |
| Display | 8-line graphical LCD with backlight |
| Power Supply | 90–230 VAC ±10%, 50–400 Hz |
| Output Options | 0–5 V / 4–20 mA / 0–10 V / 0–20 mA (user-scalable), RS-232, Bluetooth (optional) |
| Relay Alarms | 2 programmable (10 A @ 240 V AC, 8 A @ 24 V DC) |
| Sample Flow Rate | 0.5–5 SCFH |
| Pressure Range | 0–150 psig (customizable for higher pressures) |
| Wetted Materials | 316 stainless steel, PTFE, Viton seals |
| mirror surface | chromium-plated (optional Pt or 316 SS) |
| Dimensions | 375 × 457 × 178 mm (14.75 × 18 × 7 in) |
| Weight | 10.9 kg (24 lb) |
| Compliance | Manufactured and calibrated per ISO 9001:2015 |
| Brand | ETI (USA) |
|---|---|
| Origin | USA |
| Model | PI-800 Gen2 |
| Continuous Output | 800 A @ 4.2 kVA |
| Peak Output | up to 8000 A (10× rated) |
| Input Voltage Options | 120–240 VAC (Option A) or 208–277 VAC (Option B) |
| Output Voltages | 4.2 VAC / 8.4 VAC / 2.1 VAC selectable via bus configuration |
| Current Range | 10.00–1000 A (continuous), up to 8000 A (pulsed) |
| Current Accuracy | ±0.5% RDG + 0.5% RANGE + 1 digit (continuous) |
| Timer Range | 0–9999 seconds or cycles |
| Timer Accuracy | ±0.5% + 1 count |
| Dimensions | 9 in H × 17 in W × 13 in D (228.6 × 431.8 × 330 mm) |
| Weight | 44 lb (20 kg) |
| Cooling | Forced-air via internal fan |
| Enclosure | Rugged aluminum frame with impact-resistant polymer housing, interlocked carry case design |
| Interface | RS-232 serial port (9600 baud, 8N1) |
| Compliance | Designed for IEC 61000-4-11, IEEE C37.58, ANSI/IEEE C37.09, and supports GLP/GMP audit-ready test documentation workflows |
| Brand | Exaddon |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CERES |
| Pricing | Upon Request |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | Flexshuttle |
| Configuration | Modular, Scalable Laboratory Automation System |
| Application Domain | Formulation Development, High-Throughput Screening, Process Optimization in Coatings & Paints R&D |