Other Industry Specialized Instruments
Filter
Showing 151–180 of 298 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3200 |
| Measurement Range | CH₄: (0–100)%, CO₂: (0–50)%, H₂S: (0–9999) ppm, O₂: (0–25)% |
| Resolution | CH₄/CO₂/O₂: 0.01% |
| H₂S | 1 ppm |
| Response Time | T₉₀ < 10 s (NDIR) |
| Principle | Non-Dispersive Infrared (NDIR) + Long-Life Electrochemical Detection (ECD) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3200L |
| Measurement Gases | CH₄, CO₂, H₂S, O₂ |
| Detection Principle | NDIR (CH₄, CO₂) + Long-life Electrochemical Sensors (H₂S, O₂) |
| Range | CH₄: 0–100% vol |
| CO₂ | 0–50% vol |
| H₂S | 0–9999 ppm |
| O₂ | 0–25% vol (selectable) |
| Resolution | CH₄/CO₂/O₂: 0.01% vol |
| H₂S | 1 ppm |
| Accuracy | CH₄/CO₂: ±2% FS |
| O₂/H₂S | ±3% FS |
| Repeatability | CH₄/CO₂: 0.5% FS |
| O₂/H₂S | 1% FS |
| Response Time (T₉₀) | ≤10 s (NDIR channels) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | Rechargeable Li-ion battery |
| Communication | RS-485 / RS-232 |
| Display | LCD with real-time status and diagnostics |
| Sample Requirements | Dust-free, dry, oil-free gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3200Plus |
| Measurement Principle | CH₄/CO₂ — NDIR |
| Measurement Ranges | CH₄: (0–100)% vol |
| CO₂ | (0–50)% vol |
| H₂S | (0–9999) ppm |
| O₂ | (0–25)% vol (all ranges configurable) |
| Accuracy | CH₄/CO₂: ±2% FS |
| O₂/H₂S | ±3% FS |
| Power Supply | Rechargeable 18650 Li-ion battery (replaceable) |
| Communication | USB 2.0, Bluetooth 4.0 |
| Display | Color LCD |
| Data Storage | Internal logging with query/delete functions |
| Optional Add-ons | H₂ and CO sensor modules |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Biogas Analyzer |
| Model | Gasboard-3500UV |
| Measurement Range | H₂S: 0–500 to 5000 ppm |
| CH₄ | 0–100% vol |
| CO₂ | 0–50% vol |
| O₂ | 0–25% vol |
| Resolution | H₂S: 1 ppm |
| CH₄ | 0.01% vol |
| CO₂ | 0.01% vol |
| O₂ | 0.01% vol |
| Response Time | T₉₀ < 60 s |
| Analytical Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS), Non-Dispersive Infrared (NDIR), Electrochemical Detection (ECD) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9021EX |
| Measurement Range | CO/CO₂/CH₄/H₂/O₂/CₙHₘ/Calorific Value |
| Resolution | CO/CO₂/CH₄/CₙHₘ: ±1% FS |
| H₂/O₂ | ±2% FS |
| Minimum Full Scale | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| CₙHₘ | (0–10)% (optional) |
| Principle | NDIR + Electrochemical + Thermal Conductivity |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm (hydrocarbons other than CH₄) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1 % FS |
| H₂/O₂ | ±2 % FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232, RS-485, (4–20) mA, Ethernet |
| Display | LCD |
| Auto-calibration | Integrated zero-air pump with automatic air-based zeroing |
| Diagnostic Capability | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| CnHm (non-methane hydrocarbons) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/CnHm: ±1% FS |
| H₂/O₂ | ±2% FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Auto-calibration | Integrated zero-air pump with automatic air zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| CnHm | (0–10)% (optional) |
| Resolution | CO/CO₂/CH₄/CnHm: ±1% FS |
| H₂/O₂ | ±2% FS |
| Response Time | 15 s (NDIR) |
| Operating Principle | NDIR + Electrochemical Cell (ECD) + Thermal Conductivity Detection (TCD) |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Self-Diagnostic Function | Yes |
| Zero Calibration | Built-in air pump for automatic zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9031EX |
| Product Category | Coke Oven Gas Analyzer |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| CₙHₘ (non-methane hydrocarbons) | (0–10)% (optional) |
| Accuracy | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1% FS |
| H₂/O₂ | ±2% FS |
| Resolution | Equivalent to accuracy specification |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Self-Diagnostic Function | Yes |
| Zero Calibration | Built-in air pump for automatic zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9060 |
| Measurement Range | CH₄: (0–100)% |
| CO₂ | (0–50)% |
| H₂S | (0–9999) ppm |
| O₂ | (0–25)% |
| Resolution | CH₄/CO₂/O₂: 0.01% |
| H₂S | 1 ppm |
| Response Time | T₉₀ ≤ 60 s (NDIR) |
| Principle | NDIR + Electrochemical Detection (ECD) |
| Accuracy | CH₄/CO₂: ±1% FS |
| H₂S/O₂ | ±2% FS |
| Repeatability | CH₄/CO₂: 0.5% FS |
| H₂S/O₂ | 1% FS |
| Optimal Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, dry, oil-free |
| Electrical Interface | RS-485 / RS-232 / 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Enclosure | Stainless steel cabinet with corrosion-resistant components and integrated thermal management |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-9061 |
| Product Type | Biogas Analyzer |
| Measurement Range | CH₄: (0–100)%, CO₂: (0–50)%, H₂S: (0–9999) ppm, O₂: (0–25)% (all ranges selectable) |
| Response Time | T₉₀ ≤ 60 s (NDIR channels) |
| Principle | Non-Dispersive Infrared (NDIR) for CH₄/CO₂/O₂ |
| Flow Measurement | Integrated Ultrasonic Flow Sensor for Sample & Dilution Gas |
| Best Operating Flow | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Sample Requirements | Dust-free, oil-free, and dew-point controlled (achieved via on-board dilution) |
| Electrical Interface | RS-485 / RS-232 serial |
| Power Supply | AC 220 V, 50 Hz |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECOFOG |
| Pricing | Upon Request |
| Brand | EKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MP-11 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Automation Level | Semi-Automatic |
| Effective Test Points per I-V Curve | 400 |
| Voltage Measurement Accuracy | ±1% FS |
| Current Measurement Accuracy | ±1% FS |
| Max Voltage Range | 10–1000 V |
| Max Current Range | 0.1–30 A |
| Power Range | 10 W–18 kW |
| Scan Time | 4–60 ms |
| Internal Storage Capacity | 300 I-V curves |
| Display | 128×64 LED monochrome LCD (no backlight) |
| Host Dimensions | 230 × 320 × 180 mm |
| Host Weight | 2.5 kg |
| Sensor Unit Dimensions | 210 × 85 × 55 mm |
| Sensor Unit Weight | 0.5 kg |
| Battery | 8× Ni-MH rechargeable cells (host), 1× 006P (sensor) |
| Compliance | IEC 61215, IEC 61646, IEC 62446-1, ASTM E1036, UL 1703 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 130 |
| Pricing | Upon Request |
| Brand | Alpha Moisture Systems |
|---|---|
| Origin | United Kingdom |
| Model | CMH-P2 / CMH-RPC |
| Sensor Type | Chilled-mirror dew point sensor (primary standard method) |
| Measurement Range | −70 °C to +75 °C (−94 °F to +167 °F) with high-efficiency cooling |
| Accuracy | ±0.2 °C dew point |
| Display | 8-line graphical LCD with backlight |
| Power Supply | 90–230 VAC ±10%, 50–400 Hz |
| Output Options | 0–5 V / 4–20 mA / 0–10 V / 0–20 mA (user-scalable), RS-232, Bluetooth (optional) |
| Relay Alarms | 2 programmable (10 A @ 240 V AC, 8 A @ 24 V DC) |
| Sample Flow Rate | 0.5–5 SCFH |
| Pressure Range | 0–150 psig (customizable for higher pressures) |
| Wetted Materials | 316 stainless steel, PTFE, Viton seals |
| mirror surface | chromium-plated (optional Pt or 316 SS) |
| Dimensions | 375 × 457 × 178 mm (14.75 × 18 × 7 in) |
| Weight | 10.9 kg (24 lb) |
| Compliance | Manufactured and calibrated per ISO 9001:2015 |
| Brand | ETI (USA) |
|---|---|
| Origin | USA |
| Model | PI-800 Gen2 |
| Continuous Output | 800 A @ 4.2 kVA |
| Peak Output | up to 8000 A (10× rated) |
| Input Voltage Options | 120–240 VAC (Option A) or 208–277 VAC (Option B) |
| Output Voltages | 4.2 VAC / 8.4 VAC / 2.1 VAC selectable via bus configuration |
| Current Range | 10.00–1000 A (continuous), up to 8000 A (pulsed) |
| Current Accuracy | ±0.5% RDG + 0.5% RANGE + 1 digit (continuous) |
| Timer Range | 0–9999 seconds or cycles |
| Timer Accuracy | ±0.5% + 1 count |
| Dimensions | 9 in H × 17 in W × 13 in D (228.6 × 431.8 × 330 mm) |
| Weight | 44 lb (20 kg) |
| Cooling | Forced-air via internal fan |
| Enclosure | Rugged aluminum frame with impact-resistant polymer housing, interlocked carry case design |
| Interface | RS-232 serial port (9600 baud, 8N1) |
| Compliance | Designed for IEC 61000-4-11, IEEE C37.58, ANSI/IEEE C37.09, and supports GLP/GMP audit-ready test documentation workflows |
| Brand | Exaddon |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CERES |
| Pricing | Upon Request |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | Flexshuttle |
| Configuration | Modular, Scalable Laboratory Automation System |
| Application Domain | Formulation Development, High-Throughput Screening, Process Optimization in Coatings & Paints R&D |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PAIOS |
| Price Range | USD 14,000 – 70,000 |
| Automation Level | Semi-Automatic |
| Effective Test Area | 20 mm² |
| Voltage Measurement Resolution | Sub-nanovolt (nV) |
| Current Measurement Resolution | Sub-picoampere (pA) |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (Optional Cryo/Hot Stage) | −120 °C to +150 °C |
| Brand | AMC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T-100 |
| Motor | 1/3 HP, gear-driven with pulley transmission |
| Power Supply | 220 V, single-phase, 50/60 Hz, max. 3.5 A |
| Dimensions | 28 cm (W) × 56 cm (L) × 43 cm (H) |
| Weight | 45 kg (100 lbs) |
| Construction | 316 stainless steel frame, shaft, and beater roll |
| Disintegration Vessel | CPVC plastic pot |
| Safety | Dual interlock system + transparent polyester splash guard |
| Control | Digital revolution counter with preset stop function |
| Compliance | TAPPI T-205, ISO 5263 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LGA-C300 |
| Product Type | Coal Gas Calorific Value Analyzer |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sample Compatibility | Coal gas, coke oven gas, blast furnace gas, and mixed industrial fuel gases |
| Safety Certification Option | ATEX/IECEx-certified explosion-proof probe available |
| Data Output | 4–20 mA, RS485, Modbus TCP, optional OPC UA |
| Compliance Framework | Designed to support GLP/GMP-aligned operational records and ASTM D1826 / ISO 6976–2016–based calorific value calculation protocols |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-300S |
| Pricing | Upon Request |
| Light Source | High-brightness LED |
| Wavelength | 538 nm |
| Detection Limit | 0.10% (L-hydroxyproline) |
| Measurement Range | 0.00–40.00% (w/w L-hydroxyproline) |
| Accuracy | ±5% |
| Sample Throughput | 20 samples/hour |
| Digestion Time | 15 min (catalytic digestion) |
| Light Source Lifetime | ≥100,000 hours |
| Integrated Optical Design | LED-based solid-state light source acting as both emitter and monochromator |
| Display | Large backlit LCD with Chinese interface |
| Data Output | Built-in thermal printer (sample ID, matrix type, concentration, date, operator ID) |
| Calibration | Zero-point calibration only |
| Brand | Geotech (UK) |
|---|---|
| Origin | USA |
| Model | EA 5K (GA 5000) |
| Measurement Range | 0–10,000 ppm |
| Response Time | ≤10 s |
| Principle | Electrochemical sensing, NDIR infrared analysis, H₂-compensated CO detection |
| Certifications | ATEX II 2G Ex ib IIA T1 Gb, IECEx, UKAS ISO/IEC 17025 (Ref. No. 4533), MCERTS (under application), CSA |
| Brand | GMI (UK) |
|---|---|
| Origin | United Kingdom |
| Model | PS1 |
| Gas Detection | O₂ (0–25% vol, 0.1% res), H₂S (0–100 ppm, 1 ppm res), CO (0–500 ppm, 1 ppm res), SO₂ (0–20 ppm, 0.1 ppm res) |
| Display | Backlit LCD |
| Protection Rating | IP67 |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Dimensions | 85 × 55 × 29 mm |
| Weight | 86 g |
| Power | 3.6 V lithium-thionyl chloride battery |
| Alarm Types | Visual (360° high-brightness LED), Audible (95 dB), Vibration |
| Certifications | IECEx Ex ia IIC T4 Ga, ATEX Ex II 1G Ex ia IIC T4 Ga, UL913 Class I Div 1 Groups A–D T4, CE, MED 96/98/EC, CSA Class I Div 1 Groups A–D T4 (pending) |
| Brand | GMI (UK) |
|---|---|
| Origin | United Kingdom |
| Model | T.ex-O2 |
| Detection Principle | Electrochemical Sensor |
| Gas Measured | O₂ |
| Range | 0–25% vol |
| Resolution | 0.1% vol |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Display | Backlit high-contrast LCD (analog bar + digital readout) |
| Audible Alarm | 95 dB at 10 cm, 85 dB at 30 cm |
| Visual Alarm | Dual LED flash indicators |
| Vibration Alert | Integrated haptic feedback |
| Enclosure Material | Impact-resistant polypropylene |
| Ingress Protection | IP67 |
| Certifications | ATEX II 1 G Ex ia IIC T4, UL 913 Class I, Div 1, Groups A/B/C/D, MED |
| Battery | Rechargeable Li-ion, 3-year typical service life |
| Dimensions | 85 × 55 × 29 mm |
| Weight | 81 g (O₂ configuration) |
| Data Logging | Standard internal memory with timestamped records |
| Connectivity | USB interface for data download and calibration verification |
| Alarm Modes | STEL (Short-Term Exposure Limit), TWA (Time-Weighted Average), Peak, Lockable Alarm |
| Pump | Integrated micro-diaphragm sampling pump |
| Self-Test | Power-on diagnostic sequence with sensor and circuit validation |
| Mounting | Clip-on design for collar or vest placement near breathing zone |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Quantaurus-QY |
| Measurement Mode | DC |
| Excitation Wavelength Range | 250–800 nm |
| Emission Wavelength Range | 300–950 nm |
| Excitation Bandwidth (FWHM) | <10 nm |
| Spectrometer Type | Czerny-Turner |
| Detector | Cooled Back-Illuminated CCD |
| Detector Channels | 1024 |
| Detector Cooling Temperature | −15 °C |
| A/D Resolution | 16 bit |
| Spectral Resolution | <2 nm |
| Integrating Sphere Material | Spectralon® |
| Sphere Diameter | 3.3 inch |
| Fiber Optic Bundle Length | 1.5 m |
| Input Aperture Diameter | 1 mm |
| Brand | TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XGS-6 |
| Pricing | Available Upon Request |
| Light Source | 40 mW Semiconductor Laser |
| Recording Medium | Photopolymer Holographic Dry Plate |
| Exposure Control | Digital Electronic Timer (Manual/Programmable Modes) |
| Development | Isopropyl Alcohol Rinse + Air-Drying |
| Reconstruction Light | White Light (for Reflection Rainbow Holograms) |
| Operating Environment | Ambient Illumination (No Darkroom Required) |
| Portability | Compact, Benchtop Design |
| Illuminance Meter | Integrated Pocket-Sized Photometer (Wide Range, High Accuracy) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Supplier Type | Authorized Distributor |
| Product Category | Domestic Reference Standards |
| Schedule Classification | UN/WHO Schedule I / China NMPA Category I Psychotropic Substances |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Controlled Substance Reference Standards |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Supplier Type | Authorized Distributor |
| Product Category | Domestic Reference Standards |
| Model | High-Purity Controlled Substance Reference Standards |
| Pricing | Available Upon Request |
