| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | YT-NLA3 |
| Price | USD 6,300 (FOB) |
| Brand | Zehntner |
|---|---|
| Model | ZRM6006 |
| Origin | Switzerland |
| Measurement Modes | RL (Retroreflection Coefficient) and QD (Qd-Value / Diffuse Reflection) |
| RL Range | 0–4,000 mcd·m⁻²·lx⁻¹ |
| QD Range | 0–400 mcd·m⁻²·lx⁻¹ |
| Simulated Observation Distance | 30 m |
| Aperture Size | 50 × 218 mm |
| Detector | Photopic V(λ)-matched silicon photodiode |
| Display | Backlit grayscale LCD |
| Power Supply | 14.8 V / 6.3 Ah rechargeable lithium-ion battery |
| Compliance | EN 1436, ASTM E1710 (RL), ASTM E2302 (QD), ASTM E2177 (wet RL) |
| Calibration Traceability | METAS (Switzerland) and StrAus-Zert (Germany) |
| Brand | Zehntner |
|---|---|
| Origin | Switzerland |
| Model | ZRS6060 |
| Measurement Range | R′ = 0–2000 cd·lx⁻¹·m⁻² |
| Light Source | Tungsten-Halogen Lamp |
| Memory Capacity | 1 GB (up to 1 million measurement records) |
| Display | 3.5-inch high-resolution capacitive touchscreen |
| Power Supply | Rechargeable lithium-ion battery module |
| Standard Accessories | Calibration certificate with reference standard plaque, USB data cable, PC software (Zehntner WinRetro), rugged carrying case, AC charger |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SMART-01F |
| Pricing | Upon Request |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYD-SC96(B) |
| Pricing | Available Upon Request |
| Brand | Zhongruixiang |
|---|---|
| Origin | Beijing, China |
| Model | ZRX-29854 |
| Measurement Range | 0.05–20.00 mg/L |
| Accuracy | ≤±5% FS |
| Repeatability | ≤3% |
| Optical Drift | <0.002 A in 20 min |
| Dimensions | 80 × 230 × 55 mm |
| Weight | 500 g |
| Power Supply | 4 × AA batteries |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| IP Rating | IP65 |
| Light Source | Cold LED with narrow-band interference optical system |
| Brand | ZOLIX |
|---|---|
| Model | CS10 |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Producer) |
| Origin Category | Domestic |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm (extendable to 1700 nm) |
| Sample Size Range | 1 mm × 1 mm to 100 mm × 100 mm |
| Measurable Parameters | Spectral Responsivity (A/W), External Quantum Efficiency (EQE), Photon-to-Electron Conversion Efficiency, Integrated Short-Circuit Current Density (J<sub>sc</sub>), Beam-Induced Current (BIC) |
| Compatible Sample Types | Inorganic thin-film PV cells, dye-sensitized solar cells (DSSCs), quantum dot solar cells, organic photovoltaics (OPVs), polymer solar cells, perovskite solar cells |
| Bias Light Sources | 75 W tungsten-halogen lamp or 150 W xenon lamp |
| Software | Dedicated EQE acquisition and analysis suite with bias light parameter control |
| Brand | ZOLIX |
|---|---|
| Model | DSR300 Series |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Automation Level | Semi-Automatic |
| Effective Test Area | > Ø40 µm |
| Current Measurement Resolution | 10 pA |
| Light Spot Size | 40 µm (diffraction-limited) |
| Compatible Light Sources | Supercontinuum White-Light Laser, Picosecond Pulsed Lasers, Semiconductor Lasers, Halogen Lamps, Xenon Arc Lamps |
| Key Measurement Functions | Spectral Responsivity (A/W), Monochromatic & Power-Variable I–V, Irradiance-Dependent I–t (200 ms resolution), Bias-Dependent I–t, LBIC Mapping, Linearity Analysis, Response Speed (Transient Photovoltage/Photocurrent) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSR500-LBIC |
| Laser Wavelength (Standard) | 532 nm |
| Laser Power Stability | ≤1% over 4 h |
| Maximum Scan Range (20× objective) | 260 × 200 µm |
| Positional Repeatability | <1 µm |
| Minimum Step Size | 0.2 µm |
| Laser Spot Size | ~2 µm |
| Microscope Objective | Olympus 20×, WD = 7.5 mm, VIS range (350–750 nm) |
| Current Measurement | Keithley 2450 SourceMeter®, Range: 1 nA – 1 A, Noise Floor: 50 pA, Resolution: 20 fA, Accuracy: 0.03% |
| Probe Stage | 65 mm vacuum chuck, XYZ probe motion (12 mm travel, 0.7 µm resolution), sample XY translation (25 mm travel, 5 µm resolution) |
| Software Functions | LBIC mapping, I-V curve point-by-point acquisition, region-of-interest selection, thresholding, contour/3D visualization, spectral responsivity (optional, 200–2500 nm), EQE calculation, data export (TXT/Excel) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | DSR600 |
| Pricing | Upon Request |
| Spectral Range | 200–2400 nm (configurable per variant) |
| Calibration Method | Substitution Method (NIM-traceable) |
| Optical Design | All-reflective, dual off-axis parabolic beam path |
| Spot Size | 1 mm (uniform across spectrum) |
| Measurement Capabilities | Spectral Responsivity (R(λ)), Bias-dependent R(λ), External Quantum Efficiency (EQE), Internal Quantum Efficiency (IQE), Reflectance/Transmittance, Short-Circuit Current Density (J<sub>sc</sub>), I–V Characterization |
| Light Sources | 150 W Xe lamp, 250 W Tungsten-Halogen lamp, EQ-99XFC broadband source |
| Detection | Lock-in amplifier (Stanford Research Systems SR240/SR830 compatible) |
| Imaging Aid | Integrated CCD-based monitoring optical path for real-time beam visualization and sample alignment |
| Brand | ZOLIX |
|---|---|
| Model | DSR600-PDE |
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Quotation | Upon Request |
| Spectral Range (Source + Monochromator) | 300–1100 nm (extendable to 2500 nm) |
| Standard Detector Options | Si (300–1100 nm), InGaAs (900–1700 nm or 2500 nm), NIST-traceable calibration certificates provided |
| Data Acquisition | 2/4-channel, time resolution selectable down to 400 ps, sampling rate up to 2.5 GS/s, record length 10 M points, input impedance 1 MΩ / 50 Ω |
| Precision Source Measure Unit (SMU) | current range 10 nA–1 A, resolution 100 fA, voltage source 0–200 V |
| Programmable Dual-Channel Power Supply | 0–32 V, 1 mV resolution |
| Brand | ZOLIX |
|---|---|
| Model | DSR900 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | EMVA 1288:2020 & GB/T 17444–2013 |
| Light Source Spectral Range | 200–2500 nm |
| Monochromator Resolution | 0.08 nm @ 1200 grooves/mm grating |
| Integrating Sphere Diameter (Monochrome) | 200 mm, Reflectivity >95% (F4 coating, 250–2500 nm) |
| White-light Integrating Sphere | Up to 1100 mm diameter, Output Port ≥100 mm, Uniformity ≤1% (Ø100 mm), Stability ≤1% (30 min) |
| Darkroom Suppression Ratio | >10⁴ (80 dB) across 300–1700 nm |
| Darkroom Dimensions | ≥2000 × 1500 × 1450 mm |
| Motion Control | Motorized XYZ stage (X >100 mm, Z = 100 mm) |
| Data Interface | RS422, LVDS, Camera Link, USB |
| Acquisition Rate | 30 Hz |
| Uncertainty (k=2) | U<sub>rel</sub> = (0.9–4.0)% (800–2500 nm), (1.1–0.9)% (400–800 nm), (2.1–1.1)% (250–400 nm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | IV-B2 |
| Pricing | Upon Request |
| Wavelength Range | 350–1100 nm |
| Grating | 300 grooves/mm, blaze wavelength 500 nm |
| Slit Dimensions | 50 µm × 1 mm |
| Wavelength Calibration Source | Hg-Ne lamp |
| Responsivity Calibration Source | 150 W tungsten-halogen lamp (NIM-traceable) |
| Optical Fiber | Quartz, 200–1100 nm, 1 mm core diameter |
| Integrating Sphere | 30 mm diameter, PTFE-coated interior, 11 mm input port, 320–2200 nm spectral range, >90% reflectance across band |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SCS10-DSSC |
| Pricing | Upon Request |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm |
| Measurable Parameters | Spectral Responsivity, Incident Photon-to-Current Efficiency (IPCE), Short-Circuit Current Density (J<sub>sc</sub>) |
| Maximum Sample Area | 100 mm × 100 mm |
| Test Spot Size | 2–10 mm |
| Wavelength Accuracy | ±0.2 nm (@1200 g/mm grating) |
| Minimum Wavelength Step | 0.1 nm (recommended: 5 nm) |
| Filtering | Motorized multi-stage spectral rejection system with dual filter wheels |
| Detector | Calibrated standard silicon photodiode with NIST-traceable responsivity certificate |
| Data Acquisition Sensitivity | 100 nA |
| Sample Holder | Custom “sandwich”-style DSSC fixture |
| Required Optical Table Footprint | ≥1200 mm × 800 mm |
| Software Platform | Windows 7 (licensed), dedicated DSSC IPCE acquisition and analysis suite |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | SCS10-PEC |
| Price Range | USD 70,000–100,000 (FOB) |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm |
| Light Source | Class ABA Solar Simulator |
| Irradiance | >400 µW/cm² |
| Electrode Configuration | Three-electrode system |
| Sample Size Capacity | 50 mm × 50 mm |
| Potentiostat Voltage Range | ±5 V |
| Voltage Resolution | 10 µV |
| Zero-Offset Error | <100 µV |
| Full-Scale Voltage Control Accuracy | <1 mV |
| Current Measurement Accuracy | <0.1% |
| Current Resolution | 100 pA (standard), 1 pA (with microcurrent extension) |
| Current Range | ±50 µA to ±5 mA (standard), up to ±1 A / 12 V (high-current option) |
| Compatible Electrochemical Techniques | CV, LSV, CA, CP, EIS (DC-biased) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | SCS100 Series |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm (extendable to 1700 nm) |
| Max Sample Size | 156 mm × 156 mm |
| Compliance | IEC 60904-8, IEC 60904-9, ASTM E1021 |
| Data Export Formats | ASCII, CSV, Excel (.xlsx), XML |
| Software Architecture | Windows-based GUI with configuration file portability and audit-ready data logging |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | SCS1000 |
| Compliance | IEC 60904-8 |
| Light Source Stability | >99% |
| Minimum Spot Diameter | <1 mm |
| Dimensions | 800 mm × 900 mm × 1400 mm |
| Spectral Range | 200–2500 nm (configurable via detector & grating selection) |
| Dynamic Range | Up to 10⁶ (AC mode) |
| Mapping Capability | QE, Reflectance, LBIC with spatial resolution down to 10 µm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics |
| Product Type | Domestic |
| Model | SCS600 Series |
| Price | Contact for Quote |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Sirius Series |
| Trigger Mode | Steady-State |
| Spectral Match Class | Class A (per IEC 60904-9) |
| Irradiance Uniformity | ≤2% (A-class), ≤5% (B-class) |
| Temporal Instability | ≤2% (A-class) |
| Adjustable Irradiance Range | 0.2–1.2 sun |
| Effective Irradiation Area | 40×40 mm to 60×60 mm |
| Max Irradiance | 1200 W/m² |
| Beam Collimation | ±4° |
| Output Direction | Upward / Downward / Horizontal |
| Light Source | Short-Arc Xenon Lamp |
| Spectral Correction | Precision AM1.5G Filter Set |
| Compliance | IEC 60904-9:2020 Edition 3 |
| Brand | ZOLIX |
|---|---|
| Model | Sirius-SS |
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Category | Solar Simulator |
| Operating Mode | Steady-State |
| Compliance | IEC 60904-9 (AAA/ABA Class Options) |
| Spectral Match Range | 400–1100 nm |
| Irradiance | 1200 W/m² (adjustable) |
| Uniformity | ≤ ±2% (AAA), ≤ ±5% (ABA) |
| Temporal Stability | ≤ ±2% (AAA), ≤ ±5% (ABA) |
| Spectral Match Tolerance | 0.75–1.25 (AAA), 0.6–1.4 (ABA) |
| Lamp Type | High-Stability Short-Arc Xenon Lamp |
| Power Options | 150 W, 500 W, 1000 W |
| Beam Diameter Options | 40–150 mm |
| Optical Configuration | Arrayed Lens Homogenizer |
| Spectral Correction | Proprietary Broadband Filter Set |
| Brand | ZOLIX |
|---|---|
| Model | Sirius-SS1600A |
| Spectral Class | Class A (IEC 60904-9) |
| Irradiance Uniformity | <2% |
| Temporal Instability | <2% |
| Spectral Match Range | 0.75–1.25 |
| Illuminated Area | 210 mm × 210 mm |
| Maximum Irradiance | 1200 mW/cm² |
| Output Direction | Downward |
| Trigger Mode | Pulsed |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (OEM Producer) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SolarCellScan 10-Film |
| Measurement Mode | DC-only |
| Light Source Configuration | Modular Xenon/Tungsten-Halogen Dual Source Compatible |
| Spectral Range | 300–1700 nm (configurable via detector & source selection) |
| Sample Area Capacity | Up to 300 mm × 300 mm |
| Compliance | IEC 60904-8:2017, ISO 18557:2021 (Photovoltaic Devices — Spectral Response Measurement) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SolarCellScan100 |
| Measurement Mode | AC-coupled lock-in detection |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | SolarCellScan100 |
| Pricing | Upon Request |
| Measurement Mode | DC |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | SolarIV 100 |
| Automation Level | Semi-Automatic |
| Compliance | IEC 60904-1, IEC 60904-9 (Class AAA/ABA Simulators), ISO/IEC 17025-aligned testing workflow |
| Brand | ZOLIX |
|---|---|
| Model | SolarIV Series |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (OEM/ODM Producer) |
| Type | Domestic |
| Automation Level | Semi-Automatic |
| Price Range | USD 14,000 – 72,000 (based on configuration) |
| Compliance | IEC 60904-9:2020 (Class A Solar Simulator), ASTM E927-22 |
| Core Instrumentation | Keithley 2400/2450 SourceMeter® (optional), QE-B1 Reference Cell (calibrated to NREL traceability), IV-Software v3.x |
| Brand | ZOLIX |
|---|---|
| Model | SolarS150 |
| Illumination Type | Steady-State |
| Spectral Classification | AAA (IEC 60904-9:2020) |
| Irradiance | 1200 W/m² (adjustable) |
| Uniformity | ≤2% (40 mm diameter field) |
| Spectral Match | Class A (300–1200 nm, ±25% tolerance vs. AM1.5G) |
| Temporal Stability | <2% over 10 min (Class A) |
| Light Source | Xenon arc lamp (150 W) |
| Beam Collimation | ≥±1.5° half-angle |
| Compliance | IEC 60904-9:2020, ASTM E927-22, JIS C 8912 |