Other Physical Property Test Instruments
Filter
Showing 151–180 of 202 results
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | MHVSX-50 |
| Loading Method | Electromechanical Closed-Loop Force Control |
| Indentation Measurement | Dual-axis Encoder-equipped Eyepiece (D1/D2) |
| Display | 7-inch High-Sensitivity Touchscreen GUI |
| Optical System | High-Resolution Metallurgical Objective Lens with 10-Step Adjustable LED Illumination |
| Data Output | USB Export to Excel (.xlsx) |
| Hardness Conversion | Vickers (HV), Brinell (HB), Rockwell (HRB/HRC) |
| Compliance | ASTM E92, ISO 6507-1, JIS Z 2244 |
| Automation | Fully Automated Turret Positioning, Motorized Indenter/Objective Switching, Auto-Focus Optional |
| Software Interface | PC Communication via Optional RS-232/USB Protocol with Audit Trail Support |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-150 |
| Type | Portable Shear-Pin Operated Brinell Hardness Tester |
| Force Application | Mechanical Screw-Driven & Hammer-Impact Dual Mode |
| Hardness Scale | HBW (Brinell Hardness Number, tungsten carbide ball indenter) |
| Indentation Measurement | Optical Readout via Integrated Eyepiece Microscope |
| Compliance | Designed per ISO 6506-1, ASTM E10, and JIS Z 2243 standards |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-750 |
| Applicable Standard | ASTM E110, GB/T 4285 |
| Test Force | 750 kgf (fixed) |
| Force Application Method | Manual lever-driven hydraulic system with pressure-relief control valve |
| Indentation Hold Equivalent | 10–15 s via 3–4 repeated pressure peaks to 750 kgf |
| Mounting Method | Permanent magnet base for ferromagnetic substrates |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | T-U2 |
| Measurement Principle | Ultrasonic Contact Impedance (UCI) |
| Portability | Handheld, Battery-Powered |
| Compliance | ASTM A1038, ISO 17643, DIN 50159-2 |
| Hardness Scales | HV, HB, HRC, HRB (converted) |
| Indentation Load | 10 N (standard), optional 3 N / 5 N / 20 N |
| Probe Frequency | 98 MHz |
| Resolution | 1 HV |
| Repeatability | ±1.5 HV (under controlled conditions) |
| Operating Temperature | 0–40 °C |
| Battery Life | ≥12 hours (Li-ion, rechargeable) |
| Data Storage | Internal memory for ≥2,000 readings |
| Interface | USB-C, Bluetooth 5.0 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | T-U3 |
| Measurement Principle | Ultrasonic Contact Impedance (UCI) |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 17673, ASTM A1038, DIN 50159-2 |
| Hardness Scales | HV, HB, HRC, HRB (converted) |
| Indentation Load | 10 N (standard), optional 3 N / 5 N / 20 N |
| Probe Frequency | 10 MHz |
| Resolution | 1 HV |
| Repeatability | ≤ ±1.5 HV (per ISO 17673) |
| Operating Temperature | 0–40 °C |
| Battery Life | ≥ 12 hours (Li-ion, rechargeable) |
| Data Storage | Internal memory for ≥ 2,000 readings with timestamp, location tag (optional GPS), and operator ID |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | TH520 |
| Testing Direction | Vertical |
| Maximum Test Height | 400 mm |
| Applicable Standards | ASTM E18, ISO 6508, JIS Z 2245 |
| Hardness Scales | HRA, HRB, HRC, HRD, HRF, HRG, HRH, HRR, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T |
| Load Application | Automatic motorized loading with dual-scale force system (major/minor loads) |
| Indenter Types | Diamond cone (120°, 0.2 mm tip radius) and hardened steel ball (1/16", 1/8", 1/4", 1/2") |
| Measurement Repeatability | ≤ ±0.5 HR under standardized conditions |
| Compliance | GLP-ready architecture with audit-trail-capable software interface |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | U918 |
| Compliance | DIN 50159-1:2008, ASTM A1038-2005, JB/T 9377-2010, JJG 654-2013, GB/T 34205-2017 |
| Calibration Modes | 10-point factory calibration, single-point elastic modulus compensation, multi-point direct hardness calibration (HRC, HRB, HRA, HB, HV5) |
| Display | 3.5″ color LCD with real-time statistics (min/max/avg/count/timestamp) |
| Indentation Size | <20 µm diameter (requires >200× optical magnification for visualization) |
| Measurement Time | ≤2 s per test |
| Battery | 3.6 V / 3000 mAh Li-ion, up to 15 h operation |
| Data Storage | 50 test sets + 10 calibration profiles |
| Connectivity | Bluetooth printer support (optional), USB-C PC data export |
| Test Orientation | Omnidirectional (±5° tolerance from perpendicular) |
| Hardness Scales | HV, HRC, HRA, HRB, HB (directly calibrated, no conversion tables required) |
| Brand | Ortelli |
|---|---|
| Origin | Italy |
| Model | MVS2pro |
| Instrument Type | Buoyancy-Based Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Type | Solids (films, rods, granules) |
| Density Range | 0–2 g/cm³ |
| Temperature Control Range | 10–40 °C (standard test temp: 23 °C) |
| Cycle Time | ~3–5 min per sample |
| Auto-sampler Capacity | 16-position robotic arm |
| Compliance | ISO 1183-1, ISO 9001 |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ST-TH2O |
| Instrument Type | Soil Temperature Sensor |
| Measurement Range | -40°C to +65°C |
| Accuracy | ±0.3°C |
| Resolution | 0.1°C |
| Cable Length | 7.5 m (burial-rated, direct-burial compatible) |
| Brand | Ray-Ran |
|---|---|
| Origin | Netherlands |
| Model | DGA |
| Net Weight (3-column) | 70 kg |
| Net Weight (6-column) | 80 kg |
| Dimensions (3-column) | 850 × 400 × 1110 mm (W×D×H) |
| Dimensions (6-column) | 1200 × 400 × 1110 mm (W×D×H) |
| Power Supply | 110–240 VAC, 50–60 Hz |
| Display | 160 × 128 pixel alphanumeric graphical LCD with backlight |
| Temperature Control Accuracy | ±0.1 °C |
| Optical Magnification | 7× |
| Cooling | Integrated mini-USB compatible cooling coil |
| Pumping System | Variable-speed peristaltic pump |
| Calibration | Automated density calibration with traceable certificate |
| Compliance | CE-marked, conforms to EN 61000-6-3 and EN 61000-6-2 |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | PCP |
| Weight | 72 kg |
| Dimensions (W×D×H) | 300 × 300 × 630 mm |
| Operating Air Pressure | 10 bar (145 psi) |
| Maximum Punch Force | 50 kN |
| Compatible Die Shank Diameter | 25 mm (standard), custom shanks available |
| Cutting Plate Material | Polypropylene |
| Safety Guard | Polycarbonate interlocked shield |
| Base Footprint | 500 × 300 mm |
| Brand | Red Sun Instrument |
|---|---|
| Model | HRQS-37A |
| Measurement Principle | Schering Bridge (High-Voltage AC Null Detection) |
| Frequency | 50 Hz / 60 Hz (Power Frequency), Optional 100 Hz–10 kHz Range |
| Test Voltage | Up to 2.5 kV AC (RMS), Adjustable |
| Capacitance Range | 1 pF – 25 µF |
| Dissipation Factor (tan δ) Range | 0 – 1 |
| tan δ Accuracy | ±1.5% of reading ±0.0001 |
| Relative Permittivity (εᵣ) Resolution | 0.01 |
| εᵣ Accuracy | Derived from Cₓ/Cₙ with calibrated standard capacitor (Cₙ = 100 pF) |
| Temperature Control | Dual-zone PID-controlled heating (inner/outer chambers), simultaneous internal/external temperature monitoring |
| Compliance | ASTM D150-11, GB/T 1409-2006, GB/T 1693-2007, GB/T 5594.4-2015 |
| Data Output | Analog voltage signals + RS232 interface |
| Operating Environment | 20 ± 5 °C, 30–80% RH |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | RS-WD |
| Instrument Type | Temperature Transmitter |
| Output Options | 4–20 mA / 0–5 V / 0–10 V |
| Supply Voltage | 10–30 V DC |
| Default Temperature Accuracy | ±0.5 °C @ 25 °C |
| Extended Range Accuracy | ±1.0 °C @ 25 °C |
| Transmitter Operating Temp. | −20 to +60 °C |
| Probe Operating Temp. | −40 to +80 °C (standard) |
| Probe Humidity Range | 0–100 %RH |
| Response Time (1 m/s airflow) | ≤10 s |
| Load Capacity | ≤600 Ω (current output), ≤250 Ω (voltage output) |
| Mounting Cutout | 60 mm² |
| Display | Integrated LCD |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RH-200 Relative Humidity Generator |
| Price | Upon Request |
| RH Range | 3–95% RH |
| RH Control Accuracy | ±1.0% RH |
| Temperature Control Range | Ambient to 50 °C |
| Dew Point Range | −25 °C to 50 °C |
| Standard Flow Rate | 500 mL/min (Optional High-Flow: up to 5 L/min) |
| Brand | RHEOTECH |
|---|---|
| Origin | Japan |
| Model | FUDOH RTC-3002D |
| Load Capacity | ±200 N |
| Stroke Range | 0.1–99.9 mm (0.1 mm resolution) |
| Test Speed Options | 2, 5, 6, 10, 20, 30 cm/min or 5, 6, 10, 20, 30, 60 cm/min |
| Display | Triple 3-digit LED (force, displacement, time) |
| Auto-zero Function | Yes |
| Power Supply | 220–250 V AC, 50/60 Hz |
| Dimensions | 260 W × 430 H × 280 D mm |
| Weight | 15 kg |
| Compliance | Designed for ISO 11357, ASTM F3165, USP <1043>, and GLP-compliant texture analysis workflows |
| Brand | Rotronic |
|---|---|
| Model | HC2AS3 |
| Sensor Type | Combined Temperature & Relative Humidity Probe |
| Origin | Switzerland |
| Temperature Sensor | PT100 Platinum Resistance Thermometer (Class A) |
| Temperature Range | −50 to +100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C at 23 °C |
| Long-term Temperature Stability | <0.1 °C/year |
| RH Sensor | ROTRONIC Hygromer® IN-1 Capacitive Polymer Sensor |
| RH Range | 0 to 100.00 %RH |
| RH Resolution | 0.01 %RH |
| RH Accuracy | ±0.8 %RH at 23 °C (10–90 %RH), ±1.5 %RH at extremes |
| RH Long-term Stability | <1 %RH/year |
| Response Time (τ₆₃) | ≤22 s (at 1 m/s airflow, 23 °C) |
| Operating Temperature | −40 to +100 °C |
| Output Signal | 0–1 V analog (linear, ratiometric) |
| Supply Voltage | 5 VDC or 12 VDC |
| Current Consumption | <4.3 mA @ 5 VDC, <2.0 mA @ 12 VDC |
| Dimensions | Ø15 mm × 183 mm |
| Mass | 10 g |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | HPT-1000 |
| Maximum Operating Temperature | 1200 °C |
| Maximum Closed-Loop Load | 2000 N |
| Environmental Control | Inert Gas Sealed Chamber (N₂/Ar) |
| Sample Stage | Motorized XY Positioning System |
| Compliance | ASTM E23, ISO 6507, ISO 14577, USP <1031>, FDA 21 CFR Part 11 (Software Module) |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | Autoflex R837 |
| Sample Capacity | Up to 96 vials (2–50 mL) |
| Interface | RS-232, Ethernet, USB |
| Compatibility | DDM2911 Density Meter, J-Series Refractometers, Autopol Polarimeters |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Operating Temperature Range | 15–35 °C |
| Dimensions | 420 × 520 × 380 mm (W×D×H) |
| Weight | 22 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Software Integration | Rudolph WinCT-Density v5.0+ |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM 2911 |
| Instrument Type | Oscillating U-Tube Densitometer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ |
| Temperature Range | 0–95 °C (100 °C optional) |
| Temperature Control Accuracy | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D1250, ASTM D5931-96, DIN 51757, ISO 12185 |
| Display | 10.4″ color TFT touchscreen |
| Cell Material | Borosilicate glass with PTFE fittings |
| Interfaces | 5× USB, RS-232, Ethernet (Cat-5) |
| Operating System | Windows 7 Embedded |
| Data Storage | 32 GB internal flash memory |
| Power Supply | 85–260 VAC |
| Video View™ Technology (U.S. Patent No. 7,437,909) | 10× digital zoom for real-time bubble visualization in oscillation tube |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2909 |
| Instrument Type | Oscillating U-tube Densitometer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ (operable from 32°F to 212°F) |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Accuracy | ±0.05 °C |
| Density Repeatability | ±0.00002 g/cm³ |
| Temperature Repeatability | ±0.02 °C |
| Temperature Control Range | 0–70 °C |
| Minimum Sample Volume | < 1 mL |
| Display | 10.4″ color LCD touchscreen |
| Connectivity | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Onboard Storage | 32 GB |
| Regulatory Compliance | 21 CFR Part 11 compliant software with audit trail, IQ/OQ documentation support |
| Key Feature | Video View™ technology (U.S. Patent No. 7,437,909) for real-time 10× magnified visualization of bubble formation and settling in the oscillating U-tube |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2910 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densitometer |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Repeatability | ±0.00001 g/cm³ |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.03 °C |
| Temperature Repeatability | ±0.02 °C |
| Display Resolution | 0.0001 g/cm³ / 0.01 °C |
| Minimum Sample Volume | 1 mL |
| Viewing System | Video View™ (10× magnification, real-time U-tube bubble monitoring) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, IQ/OQ documentation available |
| Interface | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Display | 10.4″ color TFT touchscreen |
| Onboard Storage | 32 GB SSD |
| Viscosity Correction | Automatic, integrated algorithm |
| Reference Cell | Built-in temperature-stabilized reference measurement cell |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2911 Autofill |
| Instrument Type | Oscillating U-Tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 0.000001 g/cm³ |
| Density Accuracy | ±0.000010 g/cm³ |
| Density Repeatability | ±0.000002 g/cm³ |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Repeatability | ±0.001 °C |
| Display Precision | 0.000001 g/cm³ / 0.001 °C |
| Minimum Sample Volume | 1 mL |
| Integrated Viscosity Correction | Yes |
| Regulatory Compliance | 21 CFR Part 11, GLP/GMP-ready |
| Data Storage | 32 GB internal memory |
| Interface Ports | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Touchscreen | 10.4″ color LCD |
| Video View™ Technology | 10× digital zoom for real-time U-tube bubble visualization |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2911 Plus |
| Instrument Type | Oscillating U-Tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.000010 g/cm³ |
| Density Repeatability | ±0.000002 g/cm³ |
| Display Resolution | 0.000001 g/cm³ |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Repeatability | ±0.001 °C |
| Minimum Sample Volume | 1 mL |
| Built-in Reference Cell | Yes |
| Viscosity Correction | Automatic |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Data Interfaces | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Display | 10.4″ Color TFT Touchscreen |
| Onboard Storage | 32 GB |
| Video View™ Magnification | 10× Real-time U-tube Imaging |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2911 + Autoflex R837 |
| Instrument Type | Oscillating U-tube Densitometer |
| Configuration | Benchtop Laboratory System |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ |
| Temperature Control Range | 0–95 °C (100 °C optional) |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D1250, ASTM D5931-96, ISO 12185, DIN 51757 |
| Interface | USB ×5, RS-232, Ethernet (Cat-5) |
| Display | 10.4″ color TFT touchscreen |
| Construction | Borosilicate glass U-tube, PTFE fluidic interfaces |
| Data Storage | 32 GB internal flash memory |
| Operating System | Windows 7 Embedded |
| VideoView™ Technology (U.S. Patent No. 7,437,909) | 10× digital zoom for real-time bubble visualization across full U-tube length |
| Viscosity Compensation | Automatic in-situ correction |
| Regulatory Support | 21 CFR Part 11 compliant audit trail, electronic signatures, IQ/OQ/PQ documentation package |
| Power Input | 85–260 VAC, 50/60 Hz |
| Brand | Shashin Kagaku |
|---|---|
| Origin | Japan |
| Model | PV Cell Grid Line 3D Profilometer |
| Measurement Principle | White-Light Interferometry |
| Light Source Options | White LED (430–700 nm, >50,000 h), Tungsten-Halogen (400–900 nm, 10,000 h), Deuterium-Halogen (220–900 nm, 1,000 h) |
| Objective Lenses | 1× (FOV 6.6 × 8.8 mm, Optical Resolution 11 µm, Working Distance 15 mm), 5× (FOV 1.32 × 1.76 mm, Optical Resolution 2.3 µm, Working Distance 4 mm), 50× (FOV 0.132 × 0.176 mm, Optical Resolution 0.51 µm, Working Distance 3 mm) |
| Measurement Capabilities | Simultaneous 3D topography, line width (LW), line height (LH), sidewall angle, step height, roughness (Sa, Sq), and edge definition for metallized grid lines on silicon solar cells |
| Brand | SHASHIN KAGAKU |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SQ-9000 |
| Pricing | Upon Request |
| Effective Measurement Range (X×Y×Z) | 700 × 900 × 60 mm |
| Maximum Workpiece Dimensions (X×Y×Z) | 1000 × 1250 × 60 mm |
| Maximum Workpiece Thickness | 60 mm |
| Minimum Readout Unit | 0.1 µm |
| XY Measurement Accuracy | U₁ = (3 + L/250) µm, U₂ = (4 + L/230) µm |
| Z-Axis Measurement Accuracy | (1.5 + 4L/1000) µm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Product Type | Imported Instrument |
| Model | DUH-211/211S |
| Instrument Category | Microhardness Tester |
| Force Range | 0.1–1961 mN |
| Maximum Test Load | 1961 mN |
| Force Resolution | 0.196 mN |
| Force Accuracy | ±1% of displayed value |
| Displacement Measurement Range | 0–10 µm |
| Displacement Resolution | 0.0001 µm |
| Indenter | 115° triangular pyramid (Berkovich-type) |
| Optical Magnification | ×500 (with ×50 objective lens) |
| Compliance Standard | ISO 14577-1 Annex A (Martens hardness & material parameter evaluation) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HMV-G Series |
| Instrument Type | Vickers Hardness Tester |
| Test Force Range | 9.807 mN – 19.61 N |
| Maximum Total Test Force | 19.61 N |
| Specimen Space | Horizontal/Vertical travel: Unlimited |
| Depth direction | Up to 200 mm for specimens wider than 120 mm |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | AT50 |
| Instrument Type | Oscillating Hardness Tester |
| Compliance | FDA 21 CFR Part 11 Ready |
| Sample Throughput | Up to 10 distinct products per run |
| Measurement Parameters | Weight, Thickness, Width/Diameter/Length, Hardness |
| Alignment Technology | AutoAlign™ and SmartAlign™ |
| Feeding System | Multi-compartment magazine feeder (10 slots) |
| Weighing Platform | Vibration-damped, auto-centering |
| Rejection Mechanism | Real-time fragment & doublet detection |
| Software Integration | q-doc® LIMS-ready data management |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | TD1 |
| Instrument Type | Bulk Density Tester |
| Application | Solid Pharmaceutical Powders & Granules |
| Compliance | USP <616>, USP <617>, EP 2.9.34, ASTM D1464 |
| Tap Frequency | 300 ±2 taps/min (USP Method I), 250 ±2 taps/min (USP Method II / EP / ASTM) |
| Tap Height | 14 ±2 mm (USP I), 3 ±0.3 mm (USP II / EP / ASTM) |
| Cylinder Positions | 1 |
| Cylinder Volumes | 100 mL and 250 mL (interchangeable) |
| Display | 24×2 character LCD |
| Data Storage | 30 test results with timestamp, method ID, and calculated parameters |
| Output | GMP/GLP-compliant printout (via integrated thermal printer) |
| Design | Benchtop, single-cylinder, electromechanical tapping system with synchronized rotation and tapping motion |